}

Tender For Cssd Unit Project At Women Hospital Akola On Turn Key Basis, akola-Maharashtra

Tender Notice

52117546
Tender For Cssd Unit Project At Women Hospital Akola On Turn Key Basis
Tender
Indian
Maharashtra
Akola
17-11-2025

Tender Details

Tender For Cssd Unit Project At Women Hospital Akola On Turn Key Basis-A MODULAR SETUP COMPONENTS. (APPROX. 26.822X5.18X 2.6 F/C) Mtr 1 Modular Cleanroom Profile Panels for Ceiling & Walls 1.1 80mm Wall panel Both side plain GI 0.5mm Thick sheet 2 50mm Ceiling panel Both side plain GI 0.5mm Thick sheet 3 Antibacterial Paint on Civil wall,Partition panel and ceiling panel 3 Manual Hinged Door: MOC GI Powdercoated 4 Antistatic conductive vinyl flooring Compliant to standards: 7 Ceiling Peripheral Lights / OT Luminaires: LED Type B MEDICAL GRADE HVAC SYSTEM B.1 Ceiling flushed Supply and Return air diffuser B.2 External Air Handling Unit (AHU) B.3 Manual Duct VCD for balancing the air distribution B.4 Exhuast Fan cabinate for Washing area 1000Cfm C AIR DISTRIBUTION SYSTEM C.1 HVAC Ducting : 24 G As per SMACNA class ‘A’ D CONDENSING UNITS (Outdoor Units) & REFRIGERATION PIPING D.1 Condensing Units / Air Conditioning ODU 11.5TR D.2 Refrigerant piping in compliance with F ELECTRICAL & INSTRUMENTATION F.1 AHU Sub Panels 15HP VFD ONLY G.2 Power Cables G.6 Independent Distribution Box(3Phase Output) G.9 Switchboards & Sockets, Internal Wiring for lights & sockets etc(6/16Amp Min. 18nos) & 3Phase MCB - Min 10Nos) OTHER ANCILLARY WORKS Ancillary Civil Work including Demolition (if any) Fabrication Work 1 EX Fully Automatic Double Door Washer Disinfector 2 Washing Station with Two Sink 3 Spray Gun Rinser with 8 Attachments 4 Air Gun Rinser 5 Digital Ultra Sonic Cleaner 6 Mini Dry Worktable with Under Shelf 7 Drying Cabinet 8 Single Water Distillation 9 Storage Tank 10 Hot and Cold Water Sterilizer 11 Manual Eye Wash Station 12 Double sided Packing & Control Table with Two Drawer 13 Automatic Heat-Sealing Machine 14 Worktable with Gauge Cutting Machine portable 15 Linen Fold Table with light 16 Platinum Fully Automatic Horizontal Rectangular High Pressure High Vacuum Double Door Steam Sterilizer 17 Platinum Fully Automatic Horizontal Rectangular High Pressure High Vacuum Double Door Steam Sterilizer 18 Sterilization Carriage 19 Sterilization Transfer Trolley 20 Fully Automatic Horizontal Rectangular ETO Gas Sterilizer 21 Pass Box 22 Dry Worktable with Under Shelf 23 CSSD Rack with 5 Shelves 24 Transport Open Trolley with Two Shelves 25 Linen Trolley 26 Distribution Close Trolley with 4 Shelves 27 Perforated Closed Sterilization Tray 28 Perforated Closed Sterilization Tray 29 Wire Mesh Tray 30 Wire Mesh Tray 31 UPS with Sterilizer and washer 32 Air Compressor 33 Consumables for ETO cartridge 34 Packing Reels 12 reels of 100mm 35 Packing Reels 8 reels of 200 mm 36 Packing Reels 4 reels of 300 mm 37 Class 1 Sterilization Tape 38 ETO chemical indicator class 5 (total 1000 pcs) 39 steam Chemical Indicators Class 5 (total 10000) 40 Biological Indicators 60 pc total 41 Bowie Dick Test Kit 42 RO Plant 500 Litre per hour + 1000 Litre Tank A CSSD Unit Project at Women Hospital Akola On Turn Key Basis Work Description Approx Size - 26.822X5.18X 2.6 F/C Mtr 1 Modular Cleanroom Profile Panels for Ceiling & Walls • Free-standing structure with PUF insulated Panels. • The panel joints are sealed by silicone for a perfectly flush finish. • The panel core will consist of rigid polyurethane foam, which has been injected under high pressure. Panel specifications: ➢ Panel thickness • 50mm for standard panels for ceilings Sheet Thickness - Front & back GI sheet 0.6mm (90 GSM, 340Mpa) ➢ Infill: PUF Insulation. Density 40 Kg/m3 ± 2 Kg. ➢ Panel Joints: The panels are joint together using GI section for interlocking & leveling of panels. The panel joints shall have a seamless finish by applying silicon sealant. ➢ Panel Sizes: Std. Width Min.1180mm x Length as per site requirement x 50mm thick 1.1 80mm Wall panel Both side plain GI 0.5mm Thick sheet 2 50mm Ceiling panel Both side plain GI 0.5mm Thick sheet 3 Antibacterial Paint on Civil wall,Partition panel and ceiling panel All joints between Panel to Panel, Wall to ceiling, Wall to Floor shall be covered with Putty section with Minimum radius min.50 mm. Need to level the civil wall surface wherever required for smooth finishing • Joint between coving and surface shall be cover by wall putty chemical for smooth surface Manual Hinged Door: MOC GI Powdercoated Designed to fit flush into the wall panel system on both sides, fabricated from Gi Coated Sheets. • Thickness: Shutter has sheet thickness of 0.8mm and the frame of 1.2mm. Door Leaf thickness of 46mm • Width: Standard 80 mm panel has frame width of 80 mm and shutter width of 46mm. • Infill: PUF Insulation Handle on One side, Stainless Steel Push Plates on “Push” Side, Kick Plates, Automatic Bottom Drop Seal, Concealed Tower Bolt (only for Double door), • View Window: Double insulated glass flushed to the door faces, 6mm thick plain Toughened View Glass with Black border & Sealant • Door lock: Both side key operated locking arrangement • Door size: as per the site requirements. Door opening shall be as per requirements / space availability 1800X2100 900X2100 Antistatic conductive vinyl flooring Compliant to standards: EN 1081/IEC 613404, EN 1815 & EN 12466, TVOC as per AgBB / DIBt Certifications, ISO 16000-6., Properties: • polyurethane reinforced, scratch resistant, fire resistant, chemical resistant, slip resistant, • anti- fungi & bacterial growth • dimensional stability ≤ 0.40%, static electrical charger < 2Kv, • Flooring should be seamless with perfectly curved flush- coving, resistant to mechanical stress and dynamic loads and having protection characteristic • Conductive Washable vinyl in Roll form. • Thickness: : 2.00mm Ceiling Peripheral Lights / OT Luminaires: LED Type Clean Room Recessed Type Luminaires, IP-65 grade • Brightness: 1000 Lux illumination above 1 MTR floor level around the ICU Beds. • The light fixture will be hermetically sealed from top side (ceiling side) with bottom opening for repair & maintenance. 2 X 2 46Watt 1 X 1 26Watt MEDICAL GRADE HVAC SYSTEM Ceiling flushed Supply and Return air diffuser Aluminium powdercoated Diffuser with Manual VCD. External Air Handling Unit (AHU) Supply installation, testing and commissioning of Horizontal type CEILING mounted Double Decker/Single Decker, Double Skin Air Handling Unit with 43±2 mm thk puf panel having puf density 38+/- 2 kg/m3 with thermal break extruded aluminum profile, The inner skin 0.6 mm (24G) plain GI & outer skin 0.63 mm (24G) pre coated GI construction with internal coving, Imported backward curved DIDW type centrifugal fan witth motor suitable for VFD/DOL,Air tight access door for mixing chamber, fan, filters & coil sections. Reqd. Port with silicon tubing for measuring differential pressure across all filters with help of magnehelic gauges with SS 304 box & nozzles. inlet, outlet,Bleed, FA shall have extruded aluminium opposed blade dampers with locking arrangement, SS 304 drain tray with threes die slop, DX type cooling coil, heaters for heating, limit switch, lamp for fan section, protective guard, and reqd. accessories. All filters are suitable for 60 deg c. Internal cabling with junction box, Drain U- traps,Temp. measurement sleeves. Sheet metal sectionalised cabinet type air handling unit in double skin construction fabricated from Al extruded section frame structure. The inner skin 0.6mm (24G) plain GI & outer skin 0.63 mm (24G) pre coated GI construction with 43±2 mm thick and density of 38 ± 2 kg/m3 PUF insulation panel, with internal coving and in thermal break construction. Pencil coving should be given on the inner frame of AHU. The coving should be an integral part of the frame and not applied separately. 10500CFM/145mmwg / 33TR Triple ckt / 10+3+0.3 (Combi+HEPA)Mic Air filteration / 5HP VFD compatible Motor Manual Duct VCD for balancing the air distribution Exhuast Fan cabinate for Washing area 1000Cfm AIR DISTRIBUTION SYSTEM HVAC Ducting : 24 G As per SMACNA class ‘A’ Supply, Installation and Testing of CNC machine fabricated G.S.S. Ducting should be complete with - • supports, with GI rivets, nut-bolts, with Epoxy painted MS angle Flanges, with 5mm thick neoprene gaskets duly installed between flanges. • Food grade silicon sealant shall be applied in the longitudinal length of a ducts & for all angle flanges. CONDENSING UNITS (Outdoor Units) & REFRIGERATION PIPING Condensing Units / Air Conditioning ODU 11.5TR Supply, Installation, Testing & Commissioning of Aircooled condensing unit. • Outdoor unit should be completed with copper piping, filled with R410a refrigerant gase, • Including nitrile rubber Insulation, electrical cabling, thermostatic expansion valves, liquid line strainer, HP, LP switches, control panel along with all other required electrical • With supports, tray, MS stands etc. • Consider 15 meter length between AHU & Outdoor Unit. Refrigerant piping in compliance with Supply, Installation, Testing & Commissioning of copper piping with all necessary fittings for refrigerants • Copper tubing, Expansion Valve, Dryer Filter, Gas charging etc. refrigeration accessories ELECTRICAL & INSTRUMENTATION AHU Sub Panels 15HP VFD ONLY • Supply, Installation, Testing & Commissioning of floor mounted local AHU panel • With VFD & with bypass arrangement • MOC - 16 gauge CRCA powder coated construction suitable to house VFD (with harmonic filter) for fan motor. Power Cables Supply, Laying, Testing and Commissioning of Industrial Grade Flexible single core / multi-core cables as per site requirements Standards flexible braid power cables of various sizes as per the requirement. • Laying of Cables in horizontal/vertical formation on wire mesh cable trays, supported along RCC/steel structures if required, pipe racks and cable supports provided, Independent Distribution Box(3Phase Output) Separate distribution boxes shall be provided for the separation of cabling from the CCSD room to the existing DG of the hospital. Includer Main Incomer MCCB,MCB o/p for Sockets,Lights,3Phase Eqipments etc. Switchboards & Sockets, Internal Wiring for lights & sockets etc(6/16Amp Min. 18nos) & 3Phase MCB - Min 10Nos) Switchboards & Sockets with necessary number of modular box, polycarbonate front and rear plate, modular switches, switch sockets & blank plates. ▪ Switchboard points & Light points • Switchboard Wiring 3C x 2.5 Sq.mm Cu. PVC Flexible FR Cable including Termination at both ends. OTHER ANCILLARY WORKS Ancillary Civil Work including Demolition (if any) All jobs such as demolition / breaking / reconstruction of doors / windows / walls etc. required for Modular OT /ICU related work: installation / fitment of Doors / Windows / Scrub / Waterproofing / civil foundation etc. required for completion of the said modular setup. Fabrication Work Fabricated structure / shed for AHU & Outdoor units, Supports / Stands / Ladders for Ducting, AHU, ODU, Electrical wiring & Copper piping, Drain etc.

Key Value

Document Fees
INR 25000 /-
EMD
INR 1000000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail