Educational and Research Institute Government Departments Closing in 0 days TDR #52116007

Tender For Renovation Of Ramakkalmedu Tourism Project At Idukki

Issued by Government Departments · Idukki, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Nov 2025
0 days left
EMD
80353
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Idukki → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Renovation Of Ramakkalmedu Tourism Project At Idukki-FENCING 2 Clearing grass and removal of the rubbish up to a distance of 50 m outside theperiphery of the area cleared. 3 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil 4 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) 5 Supplying and fixing PVC coated wire mesh welded and galvanized steel fabriccoated with.2mmmarine grade polyvinyl chloride(PVC) size 1.5 metre height, 3 inch dia MS tube aspole at a distance of 1.5 meter, with 2inch x2 inch PVC coated net. 6 PLAYING EQUIPMENTS 7 Roto Multi play Fun System-12 including Roto Palm Tree, Palm Tree is made up ofLLDPE Plastic inrotational moulding processes. Roto Sparrow, Roto House Canopy with Chimney,House Canopy with Chimney is made up of LLDPE roto moulded plastic.This is inshape of House Roof. House Canopy size will be minimum – 1500 mm X 1600 mm.It has fitted with chimney on top of canopy. FRP Rock Climber 5’Ht, Rock Climber is made up of Fibre Reinforce Plastic. Injection moulded rock hold are fitted on sameplatform .It has gradent of 65 degree with the ground. Minimum 6 rock hold will beof nylon in three colours. Support frame should be given from the back for strength.Roto Slide Entry - Slide entry is made up of LLDPE plastic in rotational moulding ,FRP Ladder 5’Ht 8 Monkey Climber:-Product Area : 10.7Ft x 3.1Ft, Safe Area : 16.7Ft x 6.1Ft, AgeGroup : 5 to 12 Years, Users at a Time : 4 to 6 Nos, Monkey climber side frame ismade up of 80 NB GI B-Class pipe.• Ladder frame is made up of 20 NB GI B-Class pipe & attached to main frame withnylon clamp.• Top frame is made up of 40 NB & 20 NB GI B-Class pipe. 9 Double Arc Swing with Character :- Product Area : 9.3Ft x 3.5Ft, Users at a Time: 2 Nos, Age Group : 4 to 14 Years.Safe Area : 13Ft x 13Ft, Top bar is made up of50 NB G.I B-Class pipe having 2 sets of bearing assembly & profile plate at end. •The length of top bar is 2.8m long.•Side frame is made up of 80 NB G.I B-Class pipe having 2 nos. Side frame is bendone piece in UShape. • Special design pipe clamps hold casting assembly of bearings.It gives noiseless and smoothmovement to the swing. Round cobalt coated short linkchain of 8mm diameter (electric butt welded) as per ISI: 2429, which can carry aweight of 400 kg. The chain is rubberised coated .S.S s-hook is used to hang chain inrubber belt. Seat is made up of rubber with non-skid surface with nylon lining insandwich pattern. Belt seat should be 13mm thick. S.S. triangular hook is moulded inbelt in such a way that it won’tproject from the top surface of the belt seatsRotomoulded LLDPE plastic sparrow character is fixed on top bar 10 SOLAR LIGHT 11 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil 12 Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size) 13 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) 14 Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete 15 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more 16 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). 17 Solar street light:Supply installation termination, testing and commissioning 30wSolar LED Street Light, All in one type with 60w Pannel, 12.8V 18AhLithium Phero Phospate LifePo4 Battery, Protection individually for eachcomponents Motion sensor and Hybrid Charge controller. The pole shall 5 mtr GIConical Pole Made by CNC Filament machine, and be painted with anti corrosivepaint with required thickness for protection. Each street light pole shall have properindepentent earth at each location (Excluding civil work) 18 LANDSCAPING 19 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking ofserviceable materials and then disposing of surplus soil, by spreading and neatlylevelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after floodingtrench with water (excluding cost of imported earth, sludge or manure). 20 Supplying and stacking of good earth at site including royalty and carriage upto 5k.m. lead complete (earth measured in stacks will be reduced by 20% for payment). 21 Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. leadcomplete (sludge measured in stacks will be reduced by 8% for payment). 22 Supplying and stacking at site dump manure from approved source, includingcarriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8%for payment) :Screened through sieve of I.S. designation 20 mm 23 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with waterincluding disposal of uprooted vegetation. 24 Fine dressing of the ground 25 Spreading of sludge, dump manure and/or good earth in required thickness as perdirection of officer-in-charge (cost of sludge, dump manure and/ or good earth to bepaid separately). 26 Mixing earth and sludge or manure in the required proportion specified or directed bythe Officer-in-charge 27 Grassing with selection No. 1 grass including watering and maintenance of the lawnfor 60 days or more till the grass forms a thick lawn, free from weeds and fit formowing including supplying good earth, if needed (the grass and good earth shall bepaid for separately).In rows 5 cm apart in both directions 28 Grassing with selection No. 1 grass including watering and maintenance of the lawnfor 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall bepaid for separately).With grass Turf 29 Supplying and Planting Eugeniya 2.5 feet height 30 Supplying and Planting Melastoma 2 feet height 31 Supplying and Planting maranta 32 Supplying and Planting polgadott 33 Supplying and Planting Ajuga 34 Supplying and Planting Areliya 35 ENTRANCE GATE & TICKET COUNTER 36 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil 37 Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 38 Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size) 39 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) 40 Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases up to floor five level excluding thecost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 41 Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete 42 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more 43 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 44 Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cmor nearest available size confirming to IS 2185 part I of 1979 for foundation andplinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete 45 Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. 46 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes 47 Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete 48 Finishing walls with water proofing cement paint of required shade:New work (Twoor more coats applied @ 3.84 kg/10 sqm) 49 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) 50 Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturers specifications including appropriate priming coat,preparation of surface, etc. complete.On steel work 51 Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) 52 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre-laminated particle board with decorative lamination on oneside and balancing lamination on other side 53 Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per theCost Index (Place) : Idukki, GST : 18%Printed On architectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness 54 providing clay roof tiling (Weinerbergeror equivalent material)in required size as perthe architectural drawings and the direction of engineer in charge including all fittingand fixtures, scaffolding etc, complete 55 Providing and fixing walls and false ceiling with 7.5 mm thick PVC plain panel boardceiling of approved quality in aluminium frame work with necessary screws etccomplete (aluminium frame work shall be paid separately) 56 Fixing of Aluminum composite panels, composed of laminate 2 color paintedaluminum sheets with plastic cores, in the plate form and with the thickness of 4mm 57 ENTRANCE GATE & TICKET COUNTER - ELECTRICAL WORKS 58 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C 59 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm 60 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm 61 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm 62 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch 63 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch 64 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet 65 Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required. 66 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.8 Module 67 Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings). 68 Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 69 Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door 70 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.25 amps 71 Supplying and fixing TP sheet steel enclosure on surface/ recess along with16/25/32amps 415 volts C curve TP MCB complete with connections,testing and commissioning etc. as required. 72 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2pole and earth,metal enclosed plug top along with 20 amps C curve, SP,MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover forthe socket out let and complete with connections, testing and commissioning etc. asrequired. 73 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required. 74 S/F 400mm Wall Fan with pulling cord : Supplying and fixing 400 mm sweep wallfan with 3 speedpositions with pulling cord and giving connections, etc. as per the direction ofengineer in charge as required. 75 HANDRAIL 76 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes 77 Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturers specifications including appropriate priming coat,preparation of surface, etc. complete.On steel work 78 BACK SIDE GATE 79 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil 80 Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size) 81 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) 82 Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases up to floor five level excluding thecost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 83 Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete 84 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more 85 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 86 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes 87 Finishing walls with water proofing cement paint of required shade:New work (Twoor more coats applied @ 3.84 kg/10 sqm) 88 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) 89 Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturers specifications including appropriate priming coat,preparation of surface, etc. complete.On steel work 90 RENOVATION OF TOILET BLOCK 91 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) 92 Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work 93 Providing and fixing white vitreous china pedestal type water closet (European type)with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P.flush bend with fittings & C.I. brackets, 40 mm flush bend, overflowarrangement with specials of standard make and mosquito proof coupling of approvedmunicipal design complete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required :W.C. pan with ISI marked whitesolid plastic seat and lid 94 Providing and fixing white vitreous china flat back half stall urinal of size580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) withwaste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P.brass, including painting of fittings and cutting and making good the walls and floorswherever required:Single half stall urinal with 5 litre PVC. automatic flushing cistern 95 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Flat backwash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 96 Providing and fixing mirror of superior glass ( of approved quality) and of requiredshape and size with plastic moulded frame of approved make and shade with 6 mmthick hard board backing :Rectangular shape 1500x450 mm 97 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. 98 Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore 99 Providing and fixing PTMT pillar cock of approved quality and colour.15 mmnominal bore, 107 mm long, weighing not less than 110 gms 100 Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia 101 Providing and fixing PTMT urinal cock of approved quality and colour.15 mmnominal bore, 80 mm long 42 mm high and 30 mm wide with BSP female threadsweighing not less than 48 gms . 102 Supplying and fixing CP Towel rod 45cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-in-charge 103 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 104 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm widewith minimum distances of 37 mm from wall face with concealed fittingsarrangement of approved quality and colour, weighing not less than 88 gms 105 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer -in-Charge. Internal work -Exposed on wall25 mm nominal outer dia pipes 106 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer -in-Charge. Internal work -Exposed on wall32 mm nominal outer dia pipes 107 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer -in-Charge. Internal work -Exposed on wall40 mm nominal outer dia pipes 108 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes& fittings, with one step CPVC solvent cement and the cost ofcutting chases and making good the same including testing of joints complete as perdirection of Engineer-in-Charge. Concealed work, including cutting chases andmaking good the wall etc.15 mm nominal outer dia pipes 109 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe10Kgf/cm2 110 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 50 mm pipe10 kgf/cm2 111 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall 112 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall 113 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame. 114 Providing and fixing to existing door frames.30 mm thick Glas Fibre ReinforcedPlastic (FRP) panelled door shutter of required colour and approved brand andmanufacture, made with fire - retardant grade unsaturated polyester resin, moulded to3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame andsuitable blocks of seasoned wood inside at required places for fixing of fittings, castmonolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,including fixing to frames. 115 Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. 116 Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. 117 RENOVATION OF TOILET BLOCK -ELECTRICAL WORKS 118 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C 119 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm 120 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm 121 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.40 mm 122 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch 123 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch 124 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet 125 Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required. 126 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module 127 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module 128 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.4 Module 129 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.6 Module 130 Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings). 131 Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep 132 Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 133 Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door 134 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.25 amps 135 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required. 136 S/F 400mm Wall Fan with pulling cord : Supplying and fixing 400 mm sweep wallfan with 3 speedpositions with pulling cord and giving connections, etc. as per the direction ofengineer in charge as required. 137 Supply of 305 mm sweep, 1400 rpm heavy duty exhaust fan with front guard,working on 230 V AC supply, etc. as per the direction of engineer in charge asrequired 138 REOVATION OF CANTEEN 139 Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:3:6 or richer mix (i/c equivalent design mix) 140 Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 141 Dismantling doors, windows and clerestory windows (steel or wood ) shutterincluding chowkhats, architrave, holdfasts etc. complete and stacking within 50metres lead:Of area 3 sq. metres and below 142 Dismantling steel work in built up sections in angles, tees, flats and channelsincluding all gusset plates,boltd, nuts, cutting rivets, welding etc. includingdismembering and stacking within 50 metres lead. 143 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etccomplete. 144 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 145 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame. 146 Providing and fixing to existing door frames.30 mm thick Glas Fibre ReinforcedPlastic (FRP) panelled door shutter of required colour and approved brand andmanufacture, made with fire - retardant grade unsaturated polyester resin, moulded to3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame andsuitable blocks of seasoned wood inside at required places for fixing of fittings, castmonolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,including fixing to frames. 147 Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) 148 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides 149 Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness 150 Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. 151 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) 152 Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work 153 Providing and fixing false ceiling with 7.5 mm thick PVC plain panel board ceiling ofapproved quality in aluminium frame work with necessary screws etc complete(aluminium frame work shall be paid separately) 154 Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting,fixing in position and applying a priming coatof approved steel primer, including welding and bolted with special shaped washersetc. complete 155 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainlesssteel dash fasteners, stainless steel bolts etc., of required size on the top of the floor orthe side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall beconsidered excluding fixing accessories such as nuts, bolts, fasteners etc.) 156 Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases up to floor five level excluding thecost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 157 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more 158 Supplying and fixing deck sheet of 3mm thk of including Composite Deck sheet is asteel profile with ribs, embossments which helps in binding with concrete slab andtogether forms a part of the floor structure. This interlocking between the concreteand the floor deck cretes a reinforced concrete slab that serves the dual purpose ofpermanent shuttering and reinforcement. 159 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983with C.I. brackets and stainless steel plug 40 mm, including painting of fittings andbrackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm 160 Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete.Semi rigid pipe40 mm dia 161 Providing and fixing PTMT pillar cock of approved quality and colour.15 mmnominal bore, 107 mm long, weighing not less than 110 gms 162 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall 163 RENOVATION OF CANTEEN - ELECTRICAL WORKS 164 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C 165 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm 166 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm 167 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.40 mm 168 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. As required.5/6 amps switch 169 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch 170 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet 171 Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required 172 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module 173 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module 174 Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings). 175 Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep 176 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes 177 Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 178 Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door 179 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.25 amps 180 Supplying and fixing TP sheet steel enclosure on surface/ recess along with16/25/32amps 415 volts C curve TP MCB complete with connections,testing and commissioning etc. as required. 181 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2pole and earth,metal enclosed plug top along with 20 amps C curve, SP,MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover forthe socket out let and complete with connections, testing and commissioning etc. asrequired. 182 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required 183 S/F 400mm Wall Fan with pulling cord : Supplying and fixing 400 mm sweep wallfan with 3 speedpositions with pulling cord and giving connections, etc. as per the direction ofengineer in charge as required. 184 Supply of 305 mm sweep, 1400 rpm heavy duty exhaust fan with front guard,working on 230 V AC supply, etc. as per the direction of engineer in charge asrequired 185 SITTING BENCHES 186 Supplying and fixing Stone garden sitting bench with 1.5 metre length ,450 mm clearHight from groundlevel 450 mm wide seating ,450 mm wide back rest as approved by engineer incharge 187 WASTE BIN 188 FISH BIN :- Product Area diameter 1.3 ft, Capacity 64 Ltr.Material of waste bin shallbe of FRP 189 FROG BIN :- Product Area diameter 2 ft, Capacity 84 Ltr.Material of waste bin shallbe of FRP. 190 RENOVATION OF RAIN SHELTER 191 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) 192 Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturers specifications including appropriate priming coat,preparation of surface, etc. complete.On concrete work 193 Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work 194 PROPOSED SIGNAGES 195 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 196 Manufacturing, supplying and fixing retro reflective overhead signage boards madeup of 2 mm thick aluminimum sheet, face to be fully covered with high intensity andencapsulated lens type heat activated retro reflective sheeting conforming to type - lllof ASTM-D-4956-01 as approved by Engineer-in-Charge, letters, borders etc. as perIRC: 67-2001 in silver white with blue colour back ground and with high intensitygrade, pasted on substrate by pressure sensitive adhesive backing which shall beactivated by applying pressure conforming to class ll of ASTM -D-4956-01 andfixing the same to the plate of structural frame work by means of suitable sizedaluminimum alloys, rivets or bolts & nuts @ 300 mm centre to centre all alongthe periphery as well as in two vertical rows along with theft resistant measures,including the cost of painting with two or more coats of epoxy paint in grey colour onthe back side of aluminimum sheet including appropriate priming coat. The rateincludes the cost of rounding off the corners, lowering down the structural framework from the gantry, fixing and erecting the same in position all complete as perdrawings, specification and direction of the Engineer-in-Charges. (Structural framework including M.S. plate to be provided separately. Rectangular area of the sheetonly shall be measured for payment ).Overhead informatory road signage 197 Providing and fixing Destination board fixing in main entrance of compound wall top 198 MALAMUZHAKI SCULPTURE 199 Ornamental painting work for columns with required shade and including design& drawing, and direction of engineer in charge, complete finish 200 KURAVANUM KURATHIYUM 201 Ornamental painting work for columns with required shade and including design& drawing, and direction of engineer in charge, complete finish Please Enable Macros to View BoQ information

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 08-Nov-2025 Date Extension Date 10-Nov-2025

BOQ

Name of Work:- Renovation Of Ramakkalmedu Tourism Project At Idukki
Sl. No. Item Description
1FENCING
2Clearing grass and removal of the rubbish up to a distance of 50 m outside theperiphery of the area cleared.
3Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil
4Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size)
5Supplying and fixing PVC coated wire mesh welded and galvanized steel fabriccoated with.2mmmarine grade polyvinyl chloride(PVC) size 1.5 metre height, 3 inch dia MS tube aspole at a distance of 1.5 meter, with 2inch x2 inch PVC coated net.
6PLAYING EQUIPMENTS
7Roto Multi play Fun System-12 including Roto Palm Tree, Palm Tree is made up ofLLDPE Plastic inrotational moulding processes. Roto Sparrow, Roto House Canopy with Chimney,House Canopy with Chimney is made up of LLDPE roto moulded plastic.This is inshape of House Roof. House Canopy size will be minimum – 1500 mm X 1600 mm.It has fitted with chimney on top of canopy. FRP Rock Climber 5’Ht, Rock Climber is made up of Fibre Reinforce Plastic. Injection moulded rock hold are fitted on sameplatform .It has gradent of 65 degree with the ground. Minimum 6 rock hold will beof nylon in three colours. Support frame should be given from the back for strength.Roto Slide Entry - Slide entry is made up of LLDPE plastic in rotational moulding ,FRP Ladder 5’Ht
8\"Monkey Climber:-Product Area : 10.7\"Ft x 3.1\"Ft, Safe Area : 16.7\"Ft x 6.1\"Ft, AgeGroup : 5 to 12 Years, Users at a Time : 4 to 6 Nos, Monkey climber side frame ismade up of 80 NB GI B-Class pipe.• Ladder frame is made up of 20 NB GI B-Class pipe & attached to main frame withnylon clamp.• Top frame is made up of 40 NB & 20 NB GI B-Class pipe.
9Double Arc Swing with Character :- Product Area : 9.3\"Ft x 3.5\"Ft, Users at a Time: 2 Nos, Age Group : 4 to 14 Years.Safe Area : 13\"Ft x 13\"Ft, Top bar is made up of50 NB G.I B-Class pipe having 2 sets of bearing assembly & profile plate at end. •The length of top bar is 2.8m long.•Side frame is made up of 80 NB G.I B-Class pipe having 2 nos. Side frame is bendone piece in UShape. • Special design pipe clamps hold casting assembly of bearings.It gives noiseless and smoothmovement to the swing. Round cobalt coated short linkchain of 8mm diameter (electric butt welded) as per ISI: 2429, which can carry aweight of 400 kg. The chain is rubberised coated .S.S s-hook is used to hang chain inrubber belt. Seat is made up of rubber with non-skid surface with nylon lining insandwich pattern. Belt seat should be 13mm thick. S.S. triangular hook is moulded inbelt in such a way that it won’tproject from the top surface of the belt seatsRotomoulded LLDPE plastic sparrow character is fixed on top bar
10SOLAR LIGHT
11Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil
12Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size)
13Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size)
14Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
15Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
1612 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
17Solar street light:Supply installation termination, testing and commissioning 30wSolar LED Street Light, All in one type with 60w Pannel, 12.8V 18AhLithium Phero Phospate LifePo4 Battery, Protection individually for eachcomponents Motion sensor and Hybrid Charge controller. The pole shall 5 mtr GIConical Pole Made by CNC Filament machine, and be painted with anti corrosivepaint with required thickness for protection. Each street light pole shall have properindepentent earth at each location (Excluding civil work)
18LANDSCAPING
19Trenching in ordinary soil up to a depth of 60 cm including removal and stacking ofserviceable materials and then disposing of surplus soil, by spreading and neatlylevelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after floodingtrench with water (excluding cost of imported earth, sludge or manure).
20Supplying and stacking of good earth at site including royalty and carriage upto 5k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).
21Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. leadcomplete (sludge measured in stacks will be reduced by 8% for payment).
22Supplying and stacking at site dump manure from approved source, includingcarriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8%for payment) :Screened through sieve of I.S. designation 20 mm
23Uprooting weeds from the trenched area after 10 to 15 days of its flooding with waterincluding disposal of uprooted vegetation.
24Fine dressing of the ground
25Spreading of sludge, dump manure and/or good earth in required thickness as perdirection of officer-in-charge (cost of sludge, dump manure and/ or good earth to bepaid separately).
26Mixing earth and sludge or manure in the required proportion specified or directed bythe Officer-in-charge
27Grassing with selection No. 1 grass including watering and maintenance of the lawnfor 60 days or more till the grass forms a thick lawn, free from weeds and fit formowing including supplying good earth, if needed (the grass and good earth shall bepaid for separately).In rows 5 cm apart in both directions
28Grassing with selection No. 1 grass including watering and maintenance of the lawnfor 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall bepaid for separately).With grass Turf
29Supplying and Planting Eugeniya 2.5 feet height
30Supplying and Planting Melastoma 2 feet height
31Supplying and Planting maranta
32Supplying and Planting polgadott
33Supplying and Planting Ajuga
34Supplying and Planting Areliya
35ENTRANCE GATE & TICKET COUNTER
36Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil
37Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
38Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size)
39Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size)
40Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases up to floor five level excluding thecost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
41Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
42Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
4312 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
44Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cmor nearest available size confirming to IS 2185 part I of 1979 for foundation andplinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
45Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm.
46Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes
47Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete
48Finishing walls with water proofing cement paint of required shade:New work (Twoor more coats applied @ 3.84 kg/10 sqm)
49Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm)
50Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. complete.On steel work
51Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron)
52Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre-laminated particle board with decorative lamination on oneside and balancing lamination on other side
53Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per theCost Index (Place) : Idukki, GST : 18%Printed On architectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness
54providing clay roof tiling (Weinerbergeror equivalent material)in required size as perthe architectural drawings and the direction of engineer in charge including all fittingand fixtures, scaffolding etc, complete
55Providing and fixing walls and false ceiling with 7.5 mm thick PVC plain panel boardceiling of approved quality in aluminium frame work with necessary screws etccomplete (aluminium frame work shall be paid separately)
56Fixing of Aluminum composite panels, composed of laminate 2 color paintedaluminum sheets with plastic cores, in the plate form and with the thickness of 4mm
57ENTRANCE GATE & TICKET COUNTER - ELECTRICAL WORKS
58Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
59Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm
60Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm
61Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
62Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch
63Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch
64Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet
65Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required.
66Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.8 Module
67Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings).
68Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
69Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
70Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.25 amps
71Supplying and fixing TP sheet steel enclosure on surface/ recess along with16/25/32amps 415 volts "C" curve TP MCB complete with connections,testing and commissioning etc. as required.
72Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP,MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover forthe socket out let and complete with connections, testing and commissioning etc. asrequired.
73Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required.
74S/F 400mm Wall Fan with pulling cord : Supplying and fixing 400 mm sweep wallfan with 3 speedpositions with pulling cord and giving connections, etc. as per the direction ofengineer in charge as required.
75HANDRAIL
76Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes
77Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. complete.On steel work
78BACK SIDE GATE
79Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil
80Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size)
81Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size)
82Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases up to floor five level excluding thecost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
83Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
84Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
8512 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
86Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes
87Finishing walls with water proofing cement paint of required shade:New work (Twoor more coats applied @ 3.84 kg/10 sqm)
88Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm)
89Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. complete.On steel work
90RENOVATION OF TOILET BLOCK
91Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm)
92Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work
93Providing and fixing white vitreous china pedestal type water closet (European type)with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P.flush bend with fittings & C.I. brackets, 40 mm flush bend, overflowarrangement with specials of standard make and mosquito proof coupling of approvedmunicipal design complete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required :W.C. pan with ISI marked whitesolid plastic seat and lid
94Providing and fixing white vitreous china flat back half stall urinal of size580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) withwaste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P.brass, including painting of fittings and cutting and making good the walls and floorswherever required:Single half stall urinal with 5 litre PVC. automatic flushing cistern
95Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Flat backwash basin size 450x300 mm with single 15 mm C.P. brass pillar tap
96Providing and fixing mirror of superior glass ( of approved quality) and of requiredshape and size with plastic moulded frame of approved make and shade with 6 mmthick hard board backing :Rectangular shape 1500x450 mm
97Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank.
98Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore
99Providing and fixing PTMT pillar cock of approved quality and colour.15 mmnominal bore, 107 mm long, weighing not less than 110 gms
100Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia
101Providing and fixing PTMT urinal cock of approved quality and colour.15 mmnominal bore, 80 mm long 42 mm high and 30 mm wide with BSP female threadsweighing not less than 48 gms .
102Supplying and fixing CP Towel rod 45cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-in-charge
103Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
104Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm widewith minimum distances of 37 mm from wall face with concealed fittingsarrangement of approved quality and colour, weighing not less than 88 gms
105Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer -in-Charge. Internal work -Exposed on wall25 mm nominal outer dia pipes
106Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer -in-Charge. Internal work -Exposed on wall32 mm nominal outer dia pipes
107Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer -in-Charge. Internal work -Exposed on wall40 mm nominal outer dia pipes
108Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes& fittings, with one step CPVC solvent cement and the cost ofcutting chases and making good the same including testing of joints complete as perdirection of Engineer-in-Charge. Concealed work, including cutting chases andmaking good the wall etc.15 mm nominal outer dia pipes
109Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe10Kgf/cm2
110Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 50 mm pipe10 kgf/cm2
111Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall
112Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall
113Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame.
114Providing and fixing to existing door frames.30 mm thick Glas Fibre ReinforcedPlastic (FRP) panelled door shutter of required colour and approved brand andmanufacture, made with fire - retardant grade unsaturated polyester resin, moulded to3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame andsuitable blocks of seasoned wood inside at required places for fixing of fittings, castmonolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,including fixing to frames.
115Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm.
116Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,including pointing in white cement mixed with pigment of matching shade complete.
117RENOVATION OF TOILET BLOCK -ELECTRICAL WORKS
118Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
119Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm
120Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm
121Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.40 mm
122Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch
123Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch
124Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet
125Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required.
126Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module
127Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module
128Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.4 Module
129Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.6 Module
130Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings).
131Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep
132Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
133Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
134Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.25 amps
135Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required.
136S/F 400mm Wall Fan with pulling cord : Supplying and fixing 400 mm sweep wallfan with 3 speedpositions with pulling cord and giving connections, etc. as per the direction ofengineer in charge as required.
137Supply of 305 mm sweep, 1400 rpm heavy duty exhaust fan with front guard,working on 230 V AC supply, etc. as per the direction of engineer in charge asrequired
138REOVATION OF CANTEEN
139Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:3:6 or richer mix (i/c equivalent design mix)
140Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
141Dismantling doors, windows and clerestory windows (steel or wood ) shutterincluding chowkhats, architrave, holdfasts etc. complete and stacking within 50metres lead:Of area 3 sq. metres and below
142Dismantling steel work in built up sections in angles, tees, flats and channelsincluding all gusset plates,boltd, nuts, cutting rivets, welding etc. includingdismembering and stacking within 50 metres lead.
143Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etccomplete.
14412 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
145Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame.
146Providing and fixing to existing door frames.30 mm thick Glas Fibre ReinforcedPlastic (FRP) panelled door shutter of required colour and approved brand andmanufacture, made with fire - retardant grade unsaturated polyester resin, moulded to3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame andsuitable blocks of seasoned wood inside at required places for fixing of fittings, castmonolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,including fixing to frames.
147Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron)
148Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides
149Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness
150Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm.
151Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm)
152Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work
153Providing and fixing false ceiling with 7.5 mm thick PVC plain panel board ceiling ofapproved quality in aluminium frame work with necessary screws etc complete(aluminium frame work shall be paid separately)
154Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting,fixing in position and applying a priming coatof approved steel primer, including welding and bolted with special shaped washersetc. complete
155Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainlesssteel dash fasteners, stainless steel bolts etc., of required size on the top of the floor orthe side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall beconsidered excluding fixing accessories such as nuts, bolts, fasteners etc.)
156Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases up to floor five level excluding thecost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
157Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
158Supplying and fixing deck sheet of 3mm thk of including Composite Deck sheet is asteel profile with ribs, embossments which helps in binding with concrete slab andtogether forms a part of the floor structure. This interlocking between the concreteand the floor deck cretes a reinforced concrete slab that serves the dual purpose ofpermanent shuttering and reinforcement.
159Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983with C.I. brackets and stainless steel plug 40 mm, including painting of fittings andbrackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm
160Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete.Semi rigid pipe40 mm dia
161Providing and fixing PTMT pillar cock of approved quality and colour.15 mmnominal bore, 107 mm long, weighing not less than 110 gms
162Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall
163RENOVATION OF CANTEEN - ELECTRICAL WORKS
164Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
165Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm
166Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm
167Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.40 mm
168Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. As required.5/6 amps switch
169Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch
170Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet
171Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required
172Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module
173Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module
174Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings).
175Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep
176Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
177Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
178Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
179Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.25 amps
180Supplying and fixing TP sheet steel enclosure on surface/ recess along with16/25/32amps 415 volts "C" curve TP MCB complete with connections,testing and commissioning etc. as required.
181Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP,MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover forthe socket out let and complete with connections, testing and commissioning etc. asrequired.
182Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required
183S/F 400mm Wall Fan with pulling cord : Supplying and fixing 400 mm sweep wallfan with 3 speedpositions with pulling cord and giving connections, etc. as per the direction ofengineer in charge as required.
184Supply of 305 mm sweep, 1400 rpm heavy duty exhaust fan with front guard,working on 230 V AC supply, etc. as per the direction of engineer in charge asrequired
185SITTING BENCHES
186Supplying and fixing Stone garden sitting bench with 1.5 metre length ,450 mm clearHight from groundlevel 450 mm wide seating ,450 mm wide back rest as approved by engineer incharge
187WASTE BIN
188FISH BIN :- Product Area diameter 1.3 ft, Capacity 64 Ltr.Material of waste bin shallbe of FRP
189FROG BIN :- Product Area diameter 2 ft, Capacity 84 Ltr.Material of waste bin shallbe of FRP.
190RENOVATION OF RAIN SHELTER
191Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm)
192Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. complete.On concrete work
193Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work
194PROPOSED SIGNAGES
195Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
196Manufacturing, supplying and fixing retro reflective overhead signage boards madeup of 2 mm thick aluminimum sheet, face to be fully covered with high intensity andencapsulated lens type heat activated retro reflective sheeting conforming to type - lllof ASTM-D-4956-01 as approved by Engineer-in-Charge, letters, borders etc. as perIRC: 67-2001 in silver white with blue colour back ground and with high intensitygrade, pasted on substrate by pressure sensitive adhesive backing which shall beactivated by applying pressure conforming to class ll of ASTM -D-4956-01 andfixing the same to the plate of structural frame work by means of suitable sizedaluminimum alloys, rivets or bolts & nuts @ 300 mm centre to centre all alongthe periphery as well as in two vertical rows along with theft resistant measures,including the cost of painting with two or more coats of epoxy paint in grey colour onthe back side of aluminimum sheet including appropriate priming coat. The rateincludes the cost of rounding off the corners, lowering down the structural framework from the gantry, fixing and erecting the same in position all complete as perdrawings, specification and direction of the Engineer-in-Charges. (Structural framework including M.S. plate to be provided separately. Rectangular area of the sheetonly shall be measured for payment ).Overhead informatory road signage
197Providing and fixing Destination board fixing in main entrance of compound wall top
198MALAMUZHAKI SCULPTURE
199Ornamental painting work for columns with required shade and including design& drawing, and direction of engineer in charge, complete finish
200KURAVANUM KURATHIYUM
201Ornamental painting work for columns with required shade and including design& drawing, and direction of engineer in charge, complete finish Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 52116007
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 10-11-2025
Authority
Authority Name District Nirmithikendra
Work Description Tender For Renovation Of Ramakkalmedu Tourism Project At Idukki-FENCING 2 Clearing grass and removal of the rubbish up to a distance of 50 m outside theperiphery of the area cleared. 3 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil 4 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) 5 Supplying and fixing PVC coated wire mesh welded and galvanized steel fabriccoated with.2mmmarine grade polyvinyl chloride(PVC) size 1.5 metre height, 3 inch dia MS tube aspole at a distance of 1.5 meter, with 2inch x2 inch PVC coated net. 6 PLAYING EQUIPMENTS 7 Roto Multi play Fun System-12 including Roto Palm Tree, Palm Tree is made up ofLLDPE Plastic inrotational moulding processes. Roto Sparrow, Roto House Canopy with Chimney,House Canopy with Chimney is made up of LLDPE roto moulded plastic.This is inshape of House Roof. House Canopy size will be minimum – 1500 mm X 1600 mm.It has fitted with chimney on top of canopy. FRP Rock Climber 5’Ht, Rock Climber is made up of Fibre Reinforce Plastic. Injection moulded rock hold are fitted on sameplatform .It has gradent of 65 degree with the ground. Minimum 6 rock hold will beof nylon in three colours. Support frame should be given from the back for strength.Roto Slide Entry - Slide entry is made up of LLDPE plastic in rotational moulding ,FRP Ladder 5’Ht 8 Monkey Climber:-Product Area : 10.7Ft x 3.1Ft, Safe Area : 16.7Ft x 6.1Ft, AgeGroup : 5 to 12 Years, Users at a Time : 4 to 6 Nos, Monkey climber side frame ismade up of 80 NB GI B-Class pipe.• Ladder frame is made up of 20 NB GI B-Class pipe & attached to main frame withnylon clamp.• Top frame is made up of 40 NB & 20 NB GI B-Class pipe. 9 Double Arc Swing with Character :- Product Area : 9.3Ft x 3.5Ft, Users at a Time: 2 Nos, Age Group : 4 to 14 Years.Safe Area : 13Ft x 13Ft, Top bar is made up of50 NB G.I B-Class pipe having 2 sets of bearing assembly & profile plate at end. •The length of top bar is 2.8m long.•Side frame is made up of 80 NB G.I B-Class pipe having 2 nos. Side frame is bendone piece in UShape. • Special design pipe clamps hold casting assembly of bearings.It gives noiseless and smoothmovement to the swing. Round cobalt coated short linkchain of 8mm diameter (electric butt welded) as per ISI: 2429, which can carry aweight of 400 kg. The chain is rubberised coated .S.S s-hook is used to hang chain inrubber belt. Seat is made up of rubber with non-skid surface with nylon lining insandwich pattern. Belt seat should be 13mm thick. S.S. triangular hook is moulded inbelt in such a way that it won’tproject from the top surface of the belt seatsRotomoulded LLDPE plastic sparrow character is fixed on top bar 10 SOLAR LIGHT 11 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil 12 Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size) 13 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) 14 Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete 15 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more 16 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). 17 Solar street light:Supply installation termination, testing and commissioning 30wSolar LED Street Light, All in one type with 60w Pannel, 12.8V 18AhLithium Phero Phospate LifePo4 Battery, Protection individually for eachcomponents Motion sensor and Hybrid Charge controller. The pole shall 5 mtr GIConical Pole Made by CNC Filament machine, and be painted with anti corrosivepaint with required thickness for protection. Each street light pole shall have properindepentent earth at each location (Excluding civil work) 18 LANDSCAPING 19 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking ofserviceable materials and then disposing of surplus soil, by spreading and neatlylevelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after floodingtrench with water (excluding cost of imported earth, sludge or manure). 20 Supplying and stacking of good earth at site including royalty and carriage upto 5k.m. lead complete (earth measured in stacks will be reduced by 20% for payment). 21 Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. leadcomplete (sludge measured in stacks will be reduced by 8% for payment). 22 Supplying and stacking at site dump manure from approved source, includingcarriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8%for payment) :Screened through sieve of I.S. designation 20 mm 23 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with waterincluding disposal of uprooted vegetation. 24 Fine dressing of the ground 25 Spreading of sludge, dump manure and/or good earth in required thickness as perdirection of officer-in-charge (cost of sludge, dump manure and/ or good earth to bepaid separately). 26 Mixing earth and sludge or manure in the required proportion specified or directed bythe Officer-in-charge 27 Grassing with selection No. 1 grass including watering and maintenance of the lawnfor 60 days or more till the grass forms a thick lawn, free from weeds and fit formowing including supplying good earth, if needed (the grass and good earth shall bepaid for separately).In rows 5 cm apart in both directions 28 Grassing with selection No. 1 grass including watering and maintenance of the lawnfor 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall bepaid for separately).With grass Turf 29 Supplying and Planting Eugeniya 2.5 feet height 30 Supplying and Planting Melastoma 2 feet height 31 Supplying and Planting maranta 32 Supplying and Planting polgadott 33 Supplying and Planting Ajuga 34 Supplying and Planting Areliya 35 ENTRANCE GATE & TICKET COUNTER 36 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil 37 Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 38 Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size) 39 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) 40 Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases up to floor five level excluding thecost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 41 Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete 42 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more 43 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 44 Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cmor nearest available size confirming to IS 2185 part I of 1979 for foundation andplinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete 45 Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. 46 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes 47 Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete 48 Finishing walls with water proofing cement paint of required shade:New work (Twoor more coats applied @ 3.84 kg/10 sqm) 49 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) 50 Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturers specifications including appropriate priming coat,preparation of surface, etc. complete.On steel work 51 Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) 52 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre-laminated particle board with decorative lamination on oneside and balancing lamination on other side 53 Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per theCost Index (Place) : Idukki, GST : 18%Printed On architectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness 54 providing clay roof tiling (Weinerbergeror equivalent material)in required size as perthe architectural drawings and the direction of engineer in charge including all fittingand fixtures, scaffolding etc, complete 55 Providing and fixing walls and false ceiling with 7.5 mm thick PVC plain panel boardceiling of approved quality in aluminium frame work with necessary screws etccomplete (aluminium frame work shall be paid separately) 56 Fixing of Aluminum composite panels, composed of laminate 2 color paintedaluminum sheets with plastic cores, in the plate form and with the thickness of 4mm 57 ENTRANCE GATE & TICKET COUNTER - ELECTRICAL WORKS 58 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C 59 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm 60 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm 61 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm 62 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch 63 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch 64 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet 65 Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required. 66 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.8 Module 67 Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings). 68 Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 69 Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door 70 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.25 amps 71 Supplying and fixing TP sheet steel enclosure on surface/ recess along with16/25/32amps 415 volts C curve TP MCB complete with connections,testing and commissioning etc. as required. 72 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2pole and earth,metal enclosed plug top along with 20 amps C curve, SP,MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover forthe socket out let and complete with connections, testing and commissioning etc. asrequired. 73 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required. 74 S/F 400mm Wall Fan with pulling cord : Supplying and fixing 400 mm sweep wallfan with 3 speedpositions with pulling cord and giving connections, etc. as per the direction ofengineer in charge as required. 75 HANDRAIL 76 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes 77 Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturers specifications including appropriate priming coat,preparation of surface, etc. complete.On steel work 78 BACK SIDE GATE 79 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil 80 Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size) 81 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) 82 Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases up to floor five level excluding thecost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 83 Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete 84 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more 85 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 86 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes 87 Finishing walls with water proofing cement paint of required shade:New work (Twoor more coats applied @ 3.84 kg/10 sqm) 88 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) 89 Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturers specifications including appropriate priming coat,preparation of surface, etc. complete.On steel work 90 RENOVATION OF TOILET BLOCK 91 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) 92 Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work 93 Providing and fixing white vitreous china pedestal type water closet (European type)with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P.flush bend with fittings & C.I. brackets, 40 mm flush bend, overflowarrangement with specials of standard make and mosquito proof coupling of approvedmunicipal design complete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required :W.C. pan with ISI marked whitesolid plastic seat and lid 94 Providing and fixing white vitreous china flat back half stall urinal of size580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) withwaste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P.brass, including painting of fittings and cutting and making good the walls and floorswherever required:Single half stall urinal with 5 litre PVC. automatic flushing cistern 95 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Flat backwash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 96 Providing and fixing mirror of superior glass ( of approved quality) and of requiredshape and size with plastic moulded frame of approved make and shade with 6 mmthick hard board backing :Rectangular shape 1500x450 mm 97 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. 98 Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore 99 Providing and fixing PTMT pillar cock of approved quality and colour.15 mmnominal bore, 107 mm long, weighing not less than 110 gms 100 Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia 101 Providing and fixing PTMT urinal cock of approved quality and colour.15 mmnominal bore, 80 mm long 42 mm high and 30 mm wide with BSP female threadsweighing not less than 48 gms . 102 Supplying and fixing CP Towel rod 45cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-in-charge 103 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 104 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm widewith minimum distances of 37 mm from wall face with concealed fittingsarrangement of approved quality and colour, weighing not less than 88 gms 105 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer -in-Charge. Internal work -Exposed on wall25 mm nominal outer dia pipes 106 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer -in-Charge. Internal work -Exposed on wall32 mm nominal outer dia pipes 107 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer -in-Charge. Internal work -Exposed on wall40 mm nominal outer dia pipes 108 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes& fittings, with one step CPVC solvent cement and the cost ofcutting chases and making good the same including testing of joints complete as perdirection of Engineer-in-Charge. Concealed work, including cutting chases andmaking good the wall etc.15 mm nominal outer dia pipes 109 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe10Kgf/cm2 110 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 50 mm pipe10 kgf/cm2 111 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall 112 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall 113 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame. 114 Providing and fixing to existing door frames.30 mm thick Glas Fibre ReinforcedPlastic (FRP) panelled door shutter of required colour and approved brand andmanufacture, made with fire - retardant grade unsaturated polyester resin, moulded to3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame andsuitable blocks of seasoned wood inside at required places for fixing of fittings, castmonolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,including fixing to frames. 115 Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. 116 Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. 117 RENOVATION OF TOILET BLOCK -ELECTRICAL WORKS 118 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C 119 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm 120 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm 121 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.40 mm 122 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch 123 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch 124 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet 125 Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required. 126 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module 127 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module 128 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.4 Module 129 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.6 Module 130 Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings). 131 Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep 132 Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 133 Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door 134 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.25 amps 135 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required. 136 S/F 400mm Wall Fan with pulling cord : Supplying and fixing 400 mm sweep wallfan with 3 speedpositions with pulling cord and giving connections, etc. as per the direction ofengineer in charge as required. 137 Supply of 305 mm sweep, 1400 rpm heavy duty exhaust fan with front guard,working on 230 V AC supply, etc. as per the direction of engineer in charge asrequired 138 REOVATION OF CANTEEN 139 Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:3:6 or richer mix (i/c equivalent design mix) 140 Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 141 Dismantling doors, windows and clerestory windows (steel or wood ) shutterincluding chowkhats, architrave, holdfasts etc. complete and stacking within 50metres lead:Of area 3 sq. metres and below 142 Dismantling steel work in built up sections in angles, tees, flats and channelsincluding all gusset plates,boltd, nuts, cutting rivets, welding etc. includingdismembering and stacking within 50 metres lead. 143 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etccomplete. 144 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 145 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame. 146 Providing and fixing to existing door frames.30 mm thick Glas Fibre ReinforcedPlastic (FRP) panelled door shutter of required colour and approved brand andmanufacture, made with fire - retardant grade unsaturated polyester resin, moulded to3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame andsuitable blocks of seasoned wood inside at required places for fixing of fittings, castmonolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,including fixing to frames. 147 Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) 148 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides 149 Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness 150 Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. 151 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) 152 Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work 153 Providing and fixing false ceiling with 7.5 mm thick PVC plain panel board ceiling ofapproved quality in aluminium frame work with necessary screws etc complete(aluminium frame work shall be paid separately) 154 Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting,fixing in position and applying a priming coatof approved steel primer, including welding and bolted with special shaped washersetc. complete 155 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainlesssteel dash fasteners, stainless steel bolts etc., of required size on the top of the floor orthe side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall beconsidered excluding fixing accessories such as nuts, bolts, fasteners etc.) 156 Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases up to floor five level excluding thecost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 157 Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more 158 Supplying and fixing deck sheet of 3mm thk of including Composite Deck sheet is asteel profile with ribs, embossments which helps in binding with concrete slab andtogether forms a part of the floor structure. This interlocking between the concreteand the floor deck cretes a reinforced concrete slab that serves the dual purpose ofpermanent shuttering and reinforcement. 159 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983with C.I. brackets and stainless steel plug 40 mm, including painting of fittings andbrackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm 160 Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete.Semi rigid pipe40 mm dia 161 Providing and fixing PTMT pillar cock of approved quality and colour.15 mmnominal bore, 107 mm long, weighing not less than 110 gms 162 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall 163 RENOVATION OF CANTEEN - ELECTRICAL WORKS 164 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C 165 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm 166 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm 167 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.40 mm 168 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. As required.5/6 amps switch 169 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch 170 Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet 171 Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required 172 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module 173 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module 174 Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings). 175 Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep 176 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes 177 Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 178 Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door 179 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.25 amps 180 Supplying and fixing TP sheet steel enclosure on surface/ recess along with16/25/32amps 415 volts C curve TP MCB complete with connections,testing and commissioning etc. as required. 181 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2pole and earth,metal enclosed plug top along with 20 amps C curve, SP,MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover forthe socket out let and complete with connections, testing and commissioning etc. asrequired. 182 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required 183 S/F 400mm Wall Fan with pulling cord : Supplying and fixing 400 mm sweep wallfan with 3 speedpositions with pulling cord and giving connections, etc. as per the direction ofengineer in charge as required. 184 Supply of 305 mm sweep, 1400 rpm heavy duty exhaust fan with front guard,working on 230 V AC supply, etc. as per the direction of engineer in charge asrequired 185 SITTING BENCHES 186 Supplying and fixing Stone garden sitting bench with 1.5 metre length ,450 mm clearHight from groundlevel 450 mm wide seating ,450 mm wide back rest as approved by engineer incharge 187 WASTE BIN 188 FISH BIN :- Product Area diameter 1.3 ft, Capacity 64 Ltr.Material of waste bin shallbe of FRP 189 FROG BIN :- Product Area diameter 2 ft, Capacity 84 Ltr.Material of waste bin shallbe of FRP. 190 RENOVATION OF RAIN SHELTER 191 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) 192 Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturers specifications including appropriate priming coat,preparation of surface, etc. complete.On concrete work 193 Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work 194 PROPOSED SIGNAGES 195 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 196 Manufacturing, supplying and fixing retro reflective overhead signage boards madeup of 2 mm thick aluminimum sheet, face to be fully covered with high intensity andencapsulated lens type heat activated retro reflective sheeting conforming to type - lllof ASTM-D-4956-01 as approved by Engineer-in-Charge, letters, borders etc. as perIRC: 67-2001 in silver white with blue colour back ground and with high intensitygrade, pasted on substrate by pressure sensitive adhesive backing which shall beactivated by applying pressure conforming to class ll of ASTM -D-4956-01 andfixing the same to the plate of structural frame work by means of suitable sizedaluminimum alloys, rivets or bolts & nuts @ 300 mm centre to centre all alongthe periphery as well as in two vertical rows along with theft resistant measures,including the cost of painting with two or more coats of epoxy paint in grey colour onthe back side of aluminimum sheet including appropriate priming coat. The rateincludes the cost of rounding off the corners, lowering down the structural framework from the gantry, fixing and erecting the same in position all complete as perdrawings, specification and direction of the Engineer-in-Charges. (Structural framework including M.S. plate to be provided separately. Rectangular area of the sheetonly shall be measured for payment ).Overhead informatory road signage 197 Providing and fixing Destination board fixing in main entrance of compound wall top 198 MALAMUZHAKI SCULPTURE 199 Ornamental painting work for columns with required shade and including design& drawing, and direction of engineer in charge, complete finish 200 KURAVANUM KURATHIYUM 201 Ornamental painting work for columns with required shade and including design& drawing, and direction of engineer in charge, complete finish Please Enable Macros to View BoQ information
Basic Detail
Tender No DNK/IDK/CW/1/2025
Bidding Type Tender
Location
City Idukki
State Kerala
Key Dates
Publish Date 08 Nov 2025
Submission Date 10 Nov 2025
Open Date 11 Nov 2025
Finance
Tender Value Ref. Documents
Tender Fee 3000
EMD 80353
Exemption Available
Document List
BOQ_1365983.xls
ETENDERNOTICEramakalmedu.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
8140fa3d-c430-4681-a25a-3fd5ab692660.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 08, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 10, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 10, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 11, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1365983.xls

pdf

ETENDERNOTICEramakalmedu.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

html

8140fa3d-c430-4681-a25a-3fd5ab692660.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders