Tender For supply of 1. Fully Automatic Veterinary Hematology Analyzer , 1. Fully Automatic Veterinary Hematology Analyzer With Following Test Parameters: Wbc, Lymabs, Mon Abs, Neuabs, Eosabs, Eos%, Lym%, Mon%, Neu%, Rbc, Mcv, Hct, Plt, Mpv, Hgb, Rdw%, Rdwabs, Mch, Mchc, Histogram Wbc, Histogram Rbc, Histogram Plt, Histogram Eos. The Instrument Has Separate Measuring Chambers For Wbc/Hb, Rbc/Plt And Eos Abs And Eos% Measurements. The Eos Abs And Eos% Measurements Will Be Chemically Treated With Eos Reagent. (Not In The Form Of Algorithamic Calculations Based ). 2. Instrument Have Programmable Analysis Profile For Multiple Species, And Pre-Installed Animal Profiles Of Cattle, Ferret, Rabbit, Sheep, Rat, Mouse, Pig, New World Camel And Goat, Dog, Horse, Cat. 3. Instrument Have Onboard Sample Mixer Rotor With Slots For Various Sample Tube Sizes To Maintain Uniform Mixing Of Sample Before Aspiration. 4. Instrument Have Measuring Range For Rbc: 0.00-24.99 × 1012/L ;Mcv: 15.0-250.0 Fl;Hgb: 0.0-35.0 G/Dl ; Plt: 0-5000 × 109/L ; Wbc: 0.00-150.0 × 109/L. 5. Instrument Have Parameter Coefficient Of Variation For Rbc, Hgb, Mcv Should Be <1.0 % And Plt&Wbc Should Be <5.0 %. 6. Instrument Facilitated With Direct Sampling Of Edta Micro Capillary Sample Tubes In Case Of Dehydrated Animal Or Small Animal Sample Analysis To Maintain Better Sample Management. 7. Instrument Through Put Will Be A Min Of 50 Samples/Hour In 3 Part Differential Mode. 8. Instrument Have Automatic Software Driven Clog/Clot Prevention System Onboard. 9. Sample Dilution Will Be Done By Maintenance Free Shear Valve Or Srv Valve 10. The Instrument Manufacturer Has Own Vet Qcs And Calibrators For The Instrument And Control /Calibrators Assay Values Can Be Scan Into System Through Barcode Entry. 11. The System Has Closed Sample Mixing Cup And Closed Rbc And Wbc Chambers (Dual Channel) To Prevent Dust To Contaminate And Prevent False Elevation In Count 12. The System Uses To Proven And Approved Volumetric Metering Of Cell Counting, For Wbc, Rbc And Plt For High Precision Of The Results And Stability Of The Calibration 13. The System Has Automatic Floating Discriminator Of Rbc /Plt To Prevent Microcytic Rbcs Getting Counted As Plt. 14. Instrument Have Option To Connect Key Board, Barcode Readers, Usb. Lan Port For Lis Connection Facility Should Be There. 15. Instrument Have Qc Management With Mean, Sd, Cv And Lj Chart. 16. Instrument Have Onboard Reagent Inventory. 17. Instrument Have A Result Memory Of Minimum 50000 Samples. 18. Instrument Work In Mains Voltage At 200-240 V Ac And 50 Hz. 19. Instrument Have Ce Certificate. , 1. Fully Automatic Veterinary Hematology Analyzer , 1. Fully Automatic Veterinary Hematology Analyzer With Following Test Parameters: Wbc, Lymabs, Mon Abs, Neuabs, Eosabs, Eos%, Lym%, Mon%, Neu%, Rbc, Mcv, Hct, Plt, Mpv, Hgb, Rdw%, Rdwabs, Mch, Mchc, Histogram Wbc, Histogram Rbc, Histogram Plt, Histogram Eos. The Instrument Has Separate Measuring Chambers For Wbc/Hb, Rbc/Plt And Eos Abs And Eos% Measurements. The Eos Abs And Eos% Measurements Will Be Chemically Treated With Eos Reagent. (Not In The Form Of Algorithamic Calculations Based ). 2. Instrument Have Programmable Analysis Profile For Multiple Species, And Pre-Installed Animal Profiles Of Cattle, Ferret, Rabbit, Sheep, Rat, Mouse, Pig, New World Camel And Goat, Dog, Horse, Cat. 3. Instrument Have Onboard Sample Mixer Rotor With Slots For Various Sample Tube Sizes To Maintain Uniform Mixing Of Sample Before Aspiration. 4. Instrument Have Measuring Range For Rbc: 0.00-24.99 × 1012/L ;Mcv: 15.0-250.0 Fl;Hgb: 0.0-35.0 G/Dl ; Plt: 0-5000 × 109/L ; Wbc: 0.00-150.0 × 109/L. 5. Instrument Have Parameter Coefficient Of Variation For Rbc, Hgb, Mcv Should Be <1.0 % And Plt&Wbc Should Be <5.0 %. 6. Instrument Facilitated With Direct Sampling Of Edta Micro Capillary Sample Tubes In Case Of Dehydrated Animal Or Small Animal Sample Analysis To Maintain Better Sample Management. 7. Instrument Through Put Will Be A Min Of 50 Samples/Hour In 3 Part Differential Mode. 8. Instrument Have Automatic Software Driven Clog/Clot Prevention System Onboard. 9. Sample Dilution Will Be Done By Maintenance Free Shear Valve Or Srv Valve 10. The Instrument Manufacturer Has Own Vet Qcs And Calibrators For The Instrument And Control /Calibrators Assay Values Can Be Scan Into System Through Barcode Entry. 11. The System Has Closed Sample Mixing Cup And Closed Rbc And Wbc Chambers (Dual Channel) To Prevent Dust To Contaminate And Prevent False Elevation In Count 12. The System Uses To Proven And Approved Volumetric Metering Of Cell Counting, For Wbc, Rbc And Plt For High Precision Of The Results And Stability Of The Calibration 13. The System Has Automatic Floating Discriminator Of Rbc /Plt To Prevent Microcytic Rbcs Getting Counted As Plt. 14. Instrument Have Option To Connect Key Board, Barcode Readers, Usb. Lan Port For Lis Connection Facility Should Be There. 15. Instrument Have Qc Management With Mean, Sd, Cv And Lj Chart. 16. Instrument Have Onboard Reagent Inventory. 17. Instrument Have A Result Memory Of Minimum 50000 Samples. 18. Instrument Work In Mains Voltage At 200-240 V Ac And 50 Hz. 19. Instrument Have Ce Certificate. Please Enable Macros To View Boq Information