General Specifications:- System Should Include Sample Pre Dilution, Dispensing Reagents, Multi Pipetting, Plate Incubation, Plate Washing, Plate Shaking, Plate Reading & Data Management With Q.C.Should Be Able To Perform Elisa Test For Hiv, 1&2, Hbsag, H
Tender Overview
Project Description
General Specifications:- System Should Include Sample Pre Dilution, Dispensing Reagents, Multi Pipetting, Plate Incubation, Plate Washing, Plate Shaking, Plate Reading & Data Management With Q.C.Should Be Able To Perform Elisa Test For Hiv, 1&2, Hbsag, Hcv, Vdrl, And M.P. Etc.Running Mode:-Batch Wise Continuous Loading.Should Have Robotic Arm (1-2), Rotatable Up To 270 ? For Plate Transportation.Parallel Sample Pipeting For High Speed Performance.Lot Recording & Control.?Full Data Processing & Evaluation With Integrated Q.C. Data Management.?Integrated Liquid Level Detection, Reagent Specific Liquid Handling.Liquid Control Monitoring System For Liquids, Waste & Reagents.System Should Be Open For Use With Any Elisa Kit.Should Be Ce & Usfda Approved.Vendor Must Supply One Computer & Printer, With Ups Along With Instrument.Vendor Must Supply All Required Containers Like Buffer Bottles, Reagent Containers Etc. Safety Features:- Liquid Detectionclot Detectioncolor Monitoring Check.Lot Management.Positive Barcode Identification Of All Lab Ware (Samples, Microplate, Reagents, Controls Etc.)Equipment Built In Software To Manage Multiple Elisa.Rs232 Connectivity & Data Sharing Ability With Softwareintegrated With Software Which Converts Data In Astm Or Ascii Format & Communicates With Other Software. Integrated Quality Control (Levey - Jennings Chart) Should Be Operated.Technical Specificationsplate Capacity- 4 Plates Upgradable To 6 Plates.Sample Capacity:-120 ? 180 Samples Tube Position & Should Have Continuous Loading Function. Pipetting System:- A) Pipetting Channels-2/4 Pipetting Channels (Washable Or Disposable Tips).B) Volume Range: 10-1000 ?L.C) Needle Size: 1000 ?L.D) ) Needle Wash Must Be Present In The System For Complete Wash Of Needles (Inside & Outside).E) Reagent Capacity: Adequate To Conduct 4 Or 5 Elisa Test Simultaneously.F) Precision: (At 10 ?L.) < 5% Precision: (At 100 ?L.) <2.5 %Incubator:- Ambient & Heated Module Capacity- 4 Each.Micro Plate Washer:- Should Have 8 Channels.8 Channels For Aspiration. 8 Channels For Dispensing. 1-8 Wash Cycles. Wash Solution- Container With Level Detector, Multi Reagent Washer Module. Should Have Dispensing Accuracy.Residual Volume < 5 ?L Per Well. Waste Bottle Should Have Level Sensor.Micro Plate Reader:- A) 8 Measurement Channel.B) Wave Length Range- 400-800 N.M. & Must Have 405,450,492 & 620 N.M.Filter.C) Accuracy: Better Than ? 10%.D) Resolution: 0.001-0.100.E) Built In Shaking With Programmable Speed & Time.F) Measurement Mode: Single & Dual Wavelength Reading (Preferably 450 & 620 N.M.)Warranty Period 2 Years And Amc 3 Yearsuptime Of Equipment Should Be 98% And Down Time Is Less Than 2%Service Time For Mumbai In 4 Hours And Out Of Mumbai 24 Hours.
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender