Tender For Special Repair To Main Gate At Military Station Mount Abu Under Age (I) Udaipur;  1 Dismantling wrought iron or mild steel work of any description not otherwise provided for  2 Material and labour for framed work as in door or gates of angle or other section with gusset plates, rails, braces, etc. complete drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings.  3 M&L two coat of syntetic enamel paint overnewsteel surface of any description over 10cm in width or grithnot otherwise describedover one coat red oxide primerincl preparation of surfaces complete.  4 Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast con-crete articles  5 M/L for brick work with kiln burnt bricks built in cm (1:6)using sub class B bricks of compressive strength not less than 35 Kg/Sqcm straight or curved on plan exceeding 6 mtr mean radius with old size bricks all shown on drawing and as specified.  6 Taking down cement plaster on brick/stone walls etc including raking out joint, hacking for key scrubbing down with water etc.  7 Material andlabour for 15mm thick rendering in cement mortar (1:4) onbrick/stone masonry or concrete surfaces (internal walls) of any description, finished the surface even and smooth without using extra cement complete using lequid water proofing compoundall as specified.  8 Supply only integral water proofing compound  9 Material and labour for preparation of newly/old plastered surface of wall and applying two coats of plastic emulsion complete all as specified.  10 Material & Labour for Vitrified double charged of any colour/pattern, elevated tiles as approved by Engr-in-charge, 8-9 mm thick of size 600 x 300 mm on vertical faces of walls set and jointed with cement mortar and pointed in white or coloured cement to match over and including 10mm thick rough finished plaster in cement mortar (1:4) all as spd and directed.  11 M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified.  12 Demolition of cement concrete(reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition)  13 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.  14 Returning filling in of excavated any type soil including spreading leveling watering and well ramming in layers n exc 25 cm thick all as specifiedand directed by Engineer-in-Charge.  15 Removal of surplus spoil/excavated material exc. 250 m but n exc. 500 m and depositing where directed.  16 Material and labour for Cement concrete, type D2, 1:4:8 (40 mm graded stone aggregate), as in foundations, filling and mass concrete complete all as specified and directed.  17 S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips  18 -Ditto-, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.  19 Material and labour for re-inforced cement concrete (nominal mix), type B1, 1:2:4 (20 mm graded stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.  20 Material and labour for re-inforced cement concrete (nominal mix), type B1, 1:2:4 (20 mm graded stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed.  21 Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; on rough finished surfaces of concrete, flat and similar work; vertical or to batter  22 Formwork to sides of pillars, posts, struts, piers, columns and stanchions, on rough finished surfaces of concrete, square, rectangular or polygonal complete all as specified and directed.  23 Taking down carefully aluminum/copper point wiring (light/fan/socket/power) complete including fittings such as switch, socket, ceiling roses light fittings etc andand making good disturbed surface of wall all as specified and directed by Engineer-in-Charge. (Serviceablelight fitting to be kept separately for re-use).  24 M&L for point wiring 1.5 Sqmm nominal area PVC insulated and unsheathed multistranded copper conductor FRLS inPVC concealed concuit with suitable metal box and hylem sheets with multistranded insulated solid copper earth continuity conductor of size 1.5 sq mm complete all as specified and directed by Engr-in-Charge :-  25 (a)One light point controlled by one switch one way  26 (b)One fan/exhaust fan point controlled by one switch one way  27 (d)One socket out let 5 Amps 5 Pin on same board with other switch  28 All as per item No 25 here in before but with cable size 2.5 Sqmm for one 5 pin 15 Amps socket out let on independent board and multistanded insulated solid copper earth continuity conductor of size 2.5 Sq mm all as specified and directed by Engr-in-Charge.  29 S&F switch piano flush type 5 Amps single pole one way complete all as specified and directedby Engr-in-Charge.  30 S&F socket out let 3 pin 5 Amps flush type universal complete all as specified and directedby Engr-in-Charge.  31 S&F switch socket combination 2 in 1, multipin 5 Amps/15 Ampsflush type universal complete all as specified and directedby Engr-in-Charge.  32 S&F Ceilling rose on PVC board size 65 X 50 mmthree terminal complete all as specified and directedby Engr-in-Charge.  33 S&F Angle holder backelite complete all as specified and directedby Engr-in-Charge.  34 S&F fan regulator electronic step type, 230 volt , 50 Hz complete all as specified and directedby Engr-in-Charge.  35 M&L for Submain wiring with two run ofsingle core 4 Sqmm multi stranded copper conductor cable drawn through concealed with 25 mm dia PVC non metallic rigid conduits and the conduits accessories incl one run of earth continuity conductor with 4.0 sqmm multi stranded copper conductor cable all as specified and directed .Note :- Two run of single core cable and one run of earth continuity conductor and one metre of conduit shall be measured as one unit complete all as specified and directedby Engr-in-Charge.  36 S & F MCB DB SPN 4 way (double door) with 200 Amps rated bas bar, neutral link, earth bar and Din rail double door complete all as specified and directedby Engr-in-Charge.  37 S&F MCB single pole, Curve C 240 volts 5 to 32 Amps complete all as specified and directedby Engr-in-Charge.  38 S&F MCB single pole and neutral, Curve C240 volts 32 Amps complete all as specified and directedby Engr-in-Charge.  39 Supply and FixingLED tube light fitting 18 watt, 4 feet long all as per directed by Engr-in-Charge.  40 Supply and FixingLED Bulb12 Watt complete all as per directed by Engr-in-Charge.  41 Supply and Fixing in replacement of LED Bldg security light fitting 35 Watt 230 Volt outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, GI bracket with impact and corrosion resistant including thermal management in multiple optice complete with IP 65/66 protection complete all as per directed by Engr-in-Charge .  42 Supply and fixing in replacement of LED gate light 12 Watt LED fitting energy saving long lifeaesthetically designed metal body gate lightwith required nut, bolt, washer all as specified and directed of Jaquar Cat Part No OBL-BLK-34033 or its equivalent.  43 Taking down old steel tublar pole andM & L for Steel tubular swaged pole complete with 300mmx300mm & 6mm thick mild steel base plate continuously welded to pole finial taper plug , bolts nuts & screws as specified type 410 SP-22 (8.5 meter long)including factory paintedwith two coats of black bituminons paint internally throught out and externaly on embedded portion and applying two coat of Aluminium paint over a coat of red oxide primer on remaining exposed surface after erection in position, complete all as specified and directed by Engineer-in-Charge.Note: Excavation and earth work and foundation concrete shall be measured and paid separately.  44 Supply and fixing in replacement of LED Flood lights die cast aluminium corrosion resistant covered with toughned glassIP rating 65/66 ,power factor :>0.98 , THD <10% of wattage 150 watts , 100lm-120lm chip efficacy ; as per spcificationoperating voltage 90-300V/50HZ,CCt : 5700K-6500K with 1.5 mtr 1.5 sqmm 3 core with surge protection with complete accesoriesall as specified and directed by Engr-in-charge.  45 Taking down old XLPE U/G Cable and Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 Core  46 PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling for bed concrete ( for 15 cm depth in bottom of pit) & mass concrete including necessary from work complete all as specified and directed by Engineer-in-Charge  47 PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling upto 1.5 m depth & mass concrete including necessary from work complete all as specified and directed by Engineer-in-Charge  48 Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hardsoil for laying underground cables/ errection of steel tubular poles / stay pit etcall as directed by Engr-in-charge.  49 M&L for spreading, levelling in layers n exc. 25 cm thick and ramming of sand cushioning to PVC/ XLPE cables with tibba sand and punning to provide required cover to UG cables.Note :- For the purpose of payment only punned thickness will be measured.  50 Supply and lay burnt bricks sub class `B’ of size 230x115x70mm laid dry over sand cushioning in trenches as protection on the cable all as directed by Engineer-in-Charge.  51 Returning, filling in incl spreading,levelling watering and well ramming in layer n exc .25 cm in soil each layer complete specified and directed by Engr-in-Charge.  52 Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at alevel n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed by Engr-in-Charge.  53 Material and Labour for Testing of water from approved Govt lab samples collected from pump house No-01 at main Gate as per norms of WHO and submission of test reports to the entire satisfaction of Engineer-in-Charge, the test report includes following parameters:- PH value, TDS(mg/l), Hardness (as CaCO3) (mg/l), Fluoride (mg/l), Chloride (mg/l),Turbidity (NTU), E.Coli (cfu), Free residual Chlorine