| 1 | Providing and erecting Providing and erecting 3 Pole MCCB415 V100Arated short-circuit breaking capacity 25 kA (Ics=100% of Icu)adjustable thermal (overload) setting and fixed magnetic setting with provided leadsprovision for installation of shunt/UV/trip alarm contact.MCCB with phase barriers on both sidesinsulation withstand capacity 800Vno line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 2 | Supplying and erecting Supplying and erecting porcelain base iron clad cut out HC type 415V100Aerected on polished wooden block. |
| 3 | Supplying and erecting Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 100A |
| 4 | Supplying and erecting Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in MarathiHindi and English erected at position for HV/EHV (11000 Volts) installation with compliance to IS 2551-1982 |
| 5 | Supplying and erecting Supplying and erecting iron worksheet metal work consisting of CRCAsheetsvarioussectionsofiron plateschequeredplates rods bars MSpipes etc. forpanel board or any other purpose with bendingcuttingdrilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. |
| 6 | Supplying and erecting Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 AISI mark accuracy class 1.0 with backlit LCD display(Measuring and display TrivectorVIkWPFHzLast month history of kWh andMD in kW) with special features like TODTamper loggingOptical Communication Port & Display in absence of Power &with transparent hinge type box completeerectedonpolished teak woodboardduly wiredwithrequiredsizeof weather proofPVC wires duly testedby electric supply company. |
| 7 | Supplying and erecting Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 3x240V 50 Hz with optical & RS 232 portbacklit LCDmeasure & display trivector energyload surveyTODtamper detection & loggingpower ON /OFF eventsinstantaneous parameters of rating 1/5 A with display in absence of power completewithzeroadjustment&testcertificatefrom manufacturer erected on providedM.S. box and connected to CTs. |
| 8 | Supplying and erecting Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. |
| 9 | Supplying, erecting & terminating Supplying, erecting & terminating FR XLPE insulatedgalvanised steel formed wire armoured (strip) cable 1100 V3½ core35sq. mm. aluminium conductor completeerected with glands & lugson wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 10 | Supplying and erecting Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 11 | Supplying and erecting Supplying and erecting V cross arm with ISM channel of75x40x6mmfor 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height ofV cross arm as 460mmand fixed on pole with MS clamp of 80x10 mmnut boltswashers complete as per specification no. OH-PL/VCA |
| 12 | Supplying and erecting Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flangechannel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA |
| 13 | Supplying and erecting Supplying and erecting bracket for guarding of HT OH Linemadefrom channel iron 1600mm in lengthand 75x40x6mm. erected on pole complete as per specification no. OH-PL/VCA |
| 14 | Supplying and erecting Supplying and erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clampsnut bolts etc. complete as per drawing. |
| 15 | Supplying and erecting Supplying and erecting ACSR conductor of size 6/1-2.59 mm complete. (Weasel) (127.7 kg/km)as per specification No. OH-CON/ACSR |
| 16 | Supplying and erecting Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV linecomplete as per specification no. OH-INS/DI |
| 17 | Supplying and erecting Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV linecomplete asper specification no. OH-INS/PN |
| 18 | Supplying and erecting Supplying and erecting distribution class11 kV thyrite type lightening arrester with nut boltson provided MS channel as per specification no. OH-INS/LA |
| 19 | Supplying and erecting Supplying and erecting G.I. stay set for polesincluding loop insulators at inaccessible height with anchor plate 300x300x6 mm.straining screws G.l. stay wire 7/8 SWGG.l. stay rod 20mmx1.8m length and poleclamps duly erected in provided cement concrete foundation complete. |
| 20 | Providing Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materialstesting & recording the results asper specification no. EA-EP |
| 21 | Providing Providing pipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP |
| 22 | Supplying and erecting Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 23 | Supplying, installing, testing and commissioning ofSupplying, installing, testing and commissioning of3 phase11/0.433 kV50 Hz.25 kVAMineral oil immersed and naturally cooled outdoor typealuminium woundNon-sealed transformerdelta/star connected with additional neutral brought out on load sidetemperature rise should not exceed 40 ? by thermometer in oil and 45 ? by the resistance method in winding at full load ratingusing type A winding insulation (kraft paper)with standard accessories complete with test certificate with losses below 190 Watts at 50% load635Watts at 100% load as per IS 1180 (part 1) 2014 with necessary permissions of Electrical Inspectoras per specification no SS-TR-NSL. |
| 24 | Supplying and erecting Supplying and erecting 11 kV outdoor type gangoperated air break triple pole switch200 A capacitywith3postpin type insulator per phasemounted in horizontalor vertical position with necessary channelson providedcrossarmwithadequate length ofCclass G.l. pipe for operating handle erectedonextendedsquareshaft. Theoperatinghandle provided with lock and key at suitable heightfrom ground level with necessary clamp. |
| 25 | Supplying Supplying heavydutyoperating rodouterdia 25 mm & inner dia 20 mm suitable for 11 kV with brass couplings etc.for removingdropout fuses at 6 meterslength4 pieceseach with rain shade with hand grip including earthling chain 1.5m complete. |
| 26 | Supplying and erecting Supplying and erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.). |
| 27 | Making cement concrete foundation including excavation(60x 60 x 150) cm deep in 1 3 6 cement concrete 20 x 25 mm stone metal(45x 45x 45) cm /45 cm dia. x 45 cm height plinth duly plastered with necessary curing and finishing complete. (above 6 m to 9 m poles) [16-3-3] |
| 28 | Makingcement concrete foundation including excavation(60 x 60) cm x deep 1/6 of pole length in 1 3 6 cement concrete 20 x 25 mm stone metal 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plasteredwith necessary curing and finishing complete. (for above 9 m poles) [16-3-4] |
| 29 | Making cement concrete foundation including excavation(60x 60x 150) cm deep in 1 3 6 cement concrete(20 to 25) mm stone metalwith necessary curing and finishing complete.(for stay). [16-3-6] |
| 30 | MSEBS SERVICES CONNECTION CHARGES |