Tender For Special Repair To Building P47 And P48 At 5 Maratha Li Under Age (I) Ayodhya Cantt; 1 Dismantling Brick tiles or terracing tiles, single layer on roofs including thatching any type, mud phuska etc including cleaning the surface by water/airpressure and removal of debrish beyond MOD land complete all as specified and directed (Note : Height of bldg upto 4th story). 2 M&L for brushing neat cement slurry with 3.Kg of cement per sqm complete all as specified and directed. (Note : Height of bldg upto 4th story). 3 M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in roof padding/kerb, mud slopes, rounded or chamfered edge complete all as specified and directed (Note : Height of bldg upto 4th story). 4 M&L for rendering 10mm thick cement mortar 1:4 on fair face of brick work or concrete surface complete all as specified and directed (Note : Height of bldg upto 4th story). 5 M&L for water proofing treatment to roof surface with APPwater proofing membrane 3mm thick & weighing not less than 3.0 kg/sqm of approved make black finish& reinforced with non woven polyester matt of min 150 gm/sqm laid over a coat ofbitumen primer conforming to IS-3384 @ 0.4 Ltr/sqm over prepared roof surfaces, forcing overlap with a propane or a butane gas torch with a overlap of 75mm at sides & 100mm at ends & sealing as per manufacturers instructions over and including two coat of aluminium paint complete all as spd and directed. (Note : Height of bldg upto 4th story).Note :- 1. Water proofing treatment shall be got carried out by the manufacturer or their authorised applicator only. 2. Bitumen primer, bitumen and membrane shall be of same make/manufacturer. 6 Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises 7 M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thickarea of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bedding in cement mortar (1:6) complete all as specified and as directed. 8 M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thickarea of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchtiles over and including 10 mm thick rendering in CM 1:4complete all as specified and as directed. 9 Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar 10 Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) incl chequered tiling and Paver blocks 11 M&L for 1st quality non skid Virified heavey duty tiles n exc 0.11 Sqm 10 mm thick set and jointed in neat cement slurry & pointed with coloured cement to match in floor over and including including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and directed.Make-Kajaria,Somany,orientbell or equivalent as approved by AGE(I) 12 M&L for 75 mm thick cement concrete type-C-2, 1:3:6 using 40mm graded stone aggregate finished cement concrete surface even and smooth without using extra cement in floor 13 M&L for 75 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and smooth without using extra cement. Note-Plint protection will be laid in outward slope of 1in 12 and in alternative bays/panel.L ength of panel shall not exceed 2.5 m and joint between two panel shall be filled with mastic filling comrimising mixture of one part of hot blown bitumen 85/25 penetration and two part of heated sand 14 Taking down cement plaster on brick or stone walls or ceiling etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified. 15 M&L for rendering 15 mm thick on fair faces of brick work in CM in 1:4 finished even and fair andmixing with water proofing liquid as per manufacturer instruction (but excluding the cost of water proofing liquid ) external surface all as specified 16 Supply only Liquid water proofing compound of approved make. 17 M&L for rendering 10mm thick in CM (1:6) on Brick/ Conc surface finished even and fair on internal surfaces of wall. 18 M&L for rendering 5 mm thick in CM 1:3 on concrete surface in ceiling 19 M&L for preparation of new plastered surface and applying two coat of oil bound distemper on walls over a coat of primer incl 1mm thick wall care putty complete all as specified and directed. 20 M&L for complete removal of existing treatment and applying two coat of oil bound distemper on walls over a coat of primer and 1 mm thick wall care putty complete all as specified and directed. 21 M&L for preparation of new plastered surfaces of ceiling and applying two coat of oil bound distempercomplete all as specified. 22 M&L for preparing new plastered or unplastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of not less than 01 mm thick wall care puttyand including a coat of exterior wall primer complete all as specified and directed. 23 M&L for preparation of old surfaces of ceiling and applying two coats of Oil bound distempercomplete all as specified 24 M&L for preparing new plastered or unplastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of not less than 01 mm thick wall care puttyand including a coat of exterior wall primer complete all as specified and directed. 25 M&L for complete removal of existing treatment of old plastered or unplastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of not less than 01 mm thick wall care putty and including a coat of exterior wall primercomplete all as specified and directed. 26 Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings heads, shoes, bends, swan-necks, etc., incl cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) 27 S&F 110 mm borePVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc complete all as specified. 28 S&F in repair stack clamps made out of 50mm x 5mm flat iron & 16mm round iron stays including bolts & nuts and securing ends of stays for 100mm bore pipe. 29 Taking down chowkhat or frame with shutter (without taking off shutter from the frame) Area not exc 1.5 Sqm each all as specified. 30 Taking down chowkhat or frame with shutter (without taking off shutter from the frame) Area exc 1.5 Sqm but n exc 4.00 Sqm each all as specified. 31 S&F factory made single extruded WPC (WOOD POLYMER COMPOSITE) solid door/window/ceosetory window and other frame/chowkhat of size 50x100mm comprising of virgin PVC polymer of K value 58 to 60 (suspension grade calcium carbonate and natural fibre (wood powder/rice husk/wheat husk and non toxic additives (maximum toxicity index of 12 for 100 grmscomplete all as specified. 32 Providing and fixing factory made single extruded WPC wod polymer composite and decorative type flush door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 suspension grade calcium carbonate and natural fibre(wood powder/rice husk/wheat husk and non toxic additives (maximum toxicity index of 12 for 100 grmscomplete all as specified. 33 S&F 150mm stainless steel handle for door shutter complete all as specified 34 S&F 200mm stainless steel, barrel tower bolts of extruded section and fixedcomplete all as specified. 35 S&F 250mm stainless steel, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. 36 M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primercomplete all as specified. 37 S&F 100 mm long butt hinges, medium weight, cold rolled stainless steel, complete all as specified and directed 38 M&L MS Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars and similar work conforming to Fe.290.Gde-E-165 39 S&F powder coated anodised aluminium window and ventilator shutter side hung type without sash bar aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips,rubber packing ,anodised aluminium snap beading ,screw anodised aluminium fitting such as peg stays 150 mm long (1 no) hinges type B-21 100 mm long (2 no) suitable handle 1 no complete all as specified 40 S&F anodised aluminium sections in any of door, windows and ventilator etc including fabricator of frame shutter and fixing withnecessaryglazing clips, joining cleats etc., complete all as specified and directed. 41 M&L for 4.8 mm thick sheet glass ordinary quality and glazing with beading n exc 0.5 sqm in each pane complete all as specified and as directed. 42 S&F 18 mm thick PVC sheet minimum 600 Kg Density grade 1 quality one side decorative lamination and other side plain white color to make kitchen cabinet/drawer/cupboard shutters fixed with screws solvent cement adhesive as per manufacturer instructions to make kitchen cabinet sides, top and bottom shelves inside complete all as specified and directed . 43 S&F 18 mm thick PVC sheet minimum 600 Kg Density grade 1 quality both side plainwhite color to make kitchen cabinet/drawer/cupboard shutters fixed with screws solvent cement adhesive as per manufacturer instructions to make kitchen cabinet sides, top and bottom shelves inside complete all as specified and directed . 44 Supply only 75 mm dia oval shape brass handle fancy type polished bright finish complete all as specified and directed 45 S&F 40 mm width continuous (piano) hinges, mild steel, bright finish or electro-galvanised complete all as specified and directed . 46 S&F in repairs Steel rolling shutters 1.25mm thick, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete:with gear operated type with bevel gear box and crank handle 47 S&F Safety lever locks mild steel with 4 levers for rolling shutters 48 S&F Ball bearing for rolling shutters 49 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors,and making good disturbed portion / surface of wall/ floor/ ceiling etc by using cement mortar (1:4)including white / colour wash / distempering etc as required to match with the existing surfaces / location complete all as specified and as directed. 50 Material and labour for point wiringwith 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLSH PVC insulated, sheathed, copper conductor cable in and including PVC concealed conduit of not less than 20mm dia complete with all accessories/fittings, brass screws, washer etc, including modular boxes, modular front cover plates & back plate suitable for fixing modular switches/sockets and including continuous earth wire ( green colour) of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, sheathed and connected to common earth and earth duly complete all as specified and directed for the followings :- 51 All as per Srl item No. 50.00 above but for one tube light/Bulb/ Bldg security light point controlled by one, one way switch 05 / 06 Amps. 52 All as per Srl item No. 50.00 above but for One fan point / Exhaust fan point controlled by one, one way switch 05 / 06 Amps. 53 All as per Srl item No. 50.00but forOne socket outlet point 6 A on sameboard 54 All as per Srl item No. 50.00but for one socket outlet point 6 Amps on independent board 55 Material and labour for point wiringwith 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLSH PVC insulated, sheathed, copper conductor cable in and including PVC concealed conduit of not less than 20mm dia complete with all accessories/fittings, brass screws, washer etc, including modular boxes, modular front cover plates & back plate suitable for fixing modular switches/sockets and including continuous earth wire ( green colour) of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, sheathed and connected to common earth and earth duly complete all as specified and directed for the followings :- 56 S&FModular Switch, 1 module, 6A, AC, 240V, one way ISI Marked complete all as specified and directed.. 57 S&F Modular Switch, 1 module, 16A, AC, 240V, one way ISI Marked complete all as specified and directed.. 58 S&FModular Socket, 2 module, 6A, 3 pin combined, AC, 240V, ISI Marked complete all as specified and directed.. 59 S&FModular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, ISI Marked complete all as specified and directed.. 60 Supply & fixing of ceiling rose in polycarbonate 3 terminal brass flush type 6 Amps, 250 Volts, AC supply (ISI marked), fixed on & including 3 mm thick 75mm dia sunmica hylum plastic laminated round sheetcomplete all as specified and directed. 61 Taking down Old unserviceable sub main wiring any size. 62 M&L for sub main wiring with two runs of 6.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 Volts grade multistranded copper conductor single coredrawn through and including PVC concealed conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 6.00 Sqmm green in colour as earth continuity conductor connected to common earth dolly from main DB to Sub DBincluding cutting chases and making good in cement mortar (1:4) with all necessary surface finishes such as white / colour wash / distempering etc to match the existing surfaces complete all as specified.Note:- (i) Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length.(ii) Cable required for connection to DBs and MCBs shall be deemed included in quoted rates. (iii) Earth wire shall run inside the conduit pipe. 63 Taking down unserviceable main switch, DB’s insulators, DB for MCB and board etc of any type and any capacity and further disposal including making good the disturbed surfaces in cement mortar (1:4) including applying white/colour wash / paint / distemper as required to match the existing surfaces complete all as specified and as directed. 64 Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in -charge. 65 Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 4 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in -charge. 66 S & F MCB SPN 32 Amps, 230 Volts c curve10 KA, including necessary connection complete all as specified and as directed. 67 Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of25 to 32 amps, 240 Volts in proper positionall as specified and as directed. 68 Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate all as specified and directed. 69 Supply and fixing LED lamp 2 pin 9/10 watt. 70 Taking down old unserviceable light fitting any type, complete all as specified. 71 Supply and fixing LED light fitting 1x22/25 watt,220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 72 Supply and fixingceiling fans complete with blades, with down rods, with step regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CMM with service value 6.00 BEE. Five star rated with brushless directcurrent motor(BLDC)complete all as specified and directed.NOTE:Old unservicable fan shall be deposited to MES store. 73 Supply and fixing 1x36/40W LED Building security lightenergy saving & environmental friendly long life luminaire with high power LEDs as light source and electronic driver including security light brackets of 32 mm dia GI pipe medium grade upto 1.2 mtr long bend to shape at 100-120 degree including flat iron clamps and Suitable nuts and bolts grouted in wall including all material required for fitting all as specified and directed.Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant includingthermal management in multiple optics complete with IP 65/66 protection complete. 74 Taking down existing earthing of any description and M&L for new earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earthing wire 4mm dia size by means of GI bolts, nuts, check nuts and washers, earthing wire protected by GI pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 ofSSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) type C1 in chamber of size not less than 300x300x300mm (internal diamentions) with cover made of RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15cm C/C both ways and angle iron 40X40X5mm frame etc duly painted with two coats of synthetic enamel paint over a coat of red oxided primer on exposed surfaces complete all as specified and directed by Engineer-in-Charge.Note: The unit rate includes earthing wire and protection pipe upto maximum 7.5 metre from earth plate, earth point / test point.