}

Tender For Provision Of Klp For Sig Coy At Lalgarh Jattan Mil Station., Ganganagar-Rajasthan

Tender Notice

52104749
Tender For Provision Of Klp For Sig Coy At Lalgarh Jattan Mil Station.
Tender
Indian
Rajasthan
Ganganagar
22-11-2025

Tender Details

Tender For Provision Of Klp For Sig Coy At Lalgarh Jattan Mil Station.; 2 Lump sum price worked out by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I(Ref pre-priced schedule attached separately) 3 Lump sum price worked out by the tenderer for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately) 4 Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately) 5 Lump sum price worked out by the tenderer for ROAD, PATH, HARD STANDING AND CULVERT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately) 6 Lump sum price worked out by the tenderer for AREA DRAINAGE AND FOUNTAIN WORKS as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately) 7 Lump sum price worked out by the tenderer for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately) 8 Lump sum price worked out by the tenderer for SECURITY WALL, FENCING AND GATE WORKS as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately) 9 Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately) 10 Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION AND LIGHTENING PROTECTION as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately) 11 Lump sum price worked out by the tenderer for SUMMER COOLING APPLIANCES, AIR CONDITIONING AND HOT WATER SUPPLY as listed in Schedule ‘A’ Part-X(Ref pre-priced schedule attached separately) 12 Lump sum price worked out by the tenderer for SITE CLEARANCE, EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately) 13 Lump sum price worked out by the tenderer for DEMOLITION AND DISMANTLING as listed in Schedule ‘A’ Part-XII(Ref pre-priced schedule attached separately) 14 Schedule A Part-XIII(FURNITURE) 15 Almirah small steel as per drawing No. FD-1032 sheet No. 1/1 16 Almirah large steel as per drawing No. FD-1031 sheet No. 1/1 17 Locker (built-in) (steel) as per drawing No. FD-1029 sheet Nos 1/2 & 2/2 18 Work bench workshop (1800 mm X 900 mm X 760 mm) (steel) as per drawing No. FD-1024 sheet No. 1/1 19 Book case (steel) as per drawing No. FD-1028 sheet No. 1/1 20 Bath Mat (PVC) as per drawing No. FD/E6/MAP/07 sheet No. 1/1 21 Barber Chair with adjustable Headrest as per Model No. IK-2687 of Ikonic Furniture/ Professional or equivalent of Marc Salon Furniture 22 Chair easy per drawing No. FD-229 sheet No. 1/1 23 Chair easy as per drawing No. FD-358 sheet No. 1/1 24 Chair writing as per drawing No. FD-280 sheet No. 1/1 25 Chair wooden bottom without arms as per drawing No. FD-285 sheet No. 1/1 26 Chair dining as per drawing No. FD-279 sheet No. 1/1 27 Revolving Chair of Make:- Geeken, Model No:- GB-401 or equivalent of Methodex, Godrej as approved by the GE 28 Charpoy with hard top as per drawing No. FD/MAP-II/01 sheet No. 1/1 29 Desk with Dias Wooden as per drawing No. FD-399 sheet Nos 1/2 and 2/2 30 Board Notice/Display Board of size (900 mm X 1200 mm) of Make:- Alkosign, Model No:- ASGPB 90120 or other equilent make as approved by the GE 31 Drugget of variety No. Wollen, 60 tex X 12 warp, size 3000 mm X 2000 mm as per IS 697: 2005 32 Form with back (1800 mm long) as per drawing No. FD-78(M) sheet No. 1/1 33 Form without back(1525 mm long) (steel) as per FD-1027 sheet No. 1/1 34 Hat stand with mirror (large) as per drawing No. FD-362 sheet No. 1/1 35 Hot case small as per drawing No. FD-363 sheet No. 1/1 36 Ladder aluminium as per drawing No. FD-1025 sheet No. 1/1 37 Mirror (1200 mm X 1200 mm) 38 Pointer short 900 mm as per drawing No. FD-1041 sheet No. 1/1 39 Pointer medium 1220 mm as per drawing No. FD-1041 sheet No. 1/1 40 Pointer long 1525 mm as per drawing No. FD-1041 sheet No. 1/1 41 Receptacle as per drawing No. FD/E6/MAP/13 sheet No. 1/1 42 Side rack with tray three spaces (steel) as per FD-1023 Sheet No. 1/1 43 Sofa set single seater as per drawing No. FD/MAP-II/02 sheet Nos 1/2 & 2/2 44 Sofa set 5 seaters (3 + 1 + 1) as per drawing No. FD/MAP-II/02 sheet Nos 1/2 & 2/2 45 Stool steel (510 mm high) as per drawing No. FD-409 sheet No. 1/1 46 Stool 305 mm X 305 mm X 760 mm (steel) as per drawing No. FD-81(M) sheet No. 1/1 47 Meat safe as per drawing No. FD-47(M) sheet No. 1/1 48 Table clerks (steel) as per drawing No. FD-1004 sheet No. 1/1 49 Table officers (steel) as per drawing No. FD-1003 sheet Nos 1/2 & 2/2 50 Table marble top (1530 mm X 900 mm X 760 mm) as per drawing No. FD-298 sheet No. 1/1 51 Table dining 6 persons as per drawing No. FD/MAP-II/03 sheet No. 1/1 52 Table with drawer (900 mm X 600 mm X 760 mm) (steel) as per drawing No. FD-1008 sheet Nos 1/2 & 2/2 53 Table for Havs & Ors (steel) as drawing No. FD-1007 sheet No. 1/1 54 Table (600 mm X 600 mm X 760 mm) as per drawing No. FD-293 sheet No. 1/1 55 Table centre two tier (900 mm X 450 mm X 400 mm) as per drawing No. FD-274 sheet No. 1/1 56 Table centre as per drawing No. FD-375 sheet No. 1/1 57 Teapoy as per drawing No. FD-278 sheet No. 1/1 58 Schedule A Part-XIV(ARBORICULTURE) 59 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Ashoka Regional of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 60 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Azadirachta indica ( Neem ) plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 61 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Jamun of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 62 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Peepal plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 63 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Shesham plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 64 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Mahogany plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 65 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Gulmoharplant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 66 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Keenu of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 67 M & L for preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete all as specified and as directed. Note: Cost of sludge, manure or extra earth to be paid for separately. 68 M& L for plantation of shrubs, hedge etc. at the site including watering and removal of unserviceable material including shrub/ hedge plants of any type and of height 60-75 cm in earthen pots of size 20 cm complete all as specified and as directed. 69 M & L for trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure) complete all as specified and as directed. 70 Supplying and stacking at site dump manure screened through sieve of IS. designation 20 mm from approved source, including carriage from outside MD land complete all as specified and as directed. Note: Manure measured in stacks will be reduced by 8% for payment. 71 M & L for rough dressing the trenched ground including breaking clods complete all as specified and as directed. 72 M & L for uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation complete all as specified and as directed. 73 M & L for fine dressing of the ground complete all as specified and as directed. 74 M & L for spreading of sludge, dump manure and/or good earth in required thickness complete all as specified and as directed. Note: Cost of sludge, dump manure and/ or good earth to be paid separately. 75 M & L for grassing with selection No. 1 grass in rows 5 cm apart in both directions including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth complete all as specified and as directed. Note: The earth shall be paid for separately. 76 Schedule A Part-XV(MISCELLANEOUS PARTS) 77 S & F in integrated type Heat Pump water heater with following components including installation testing and commissioning Outdoor Air cooled Integrated or split type Heat Pump with recirculation mode having minimum compressor capacity 3 HP, hermetically sealed with environment friendly refrigerant. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 300 litre per hour in hybrid mode. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 300 litre per hour in hybrid mode. The ratio of Rated output heating capacity to Rated Input Power should be such that COP of the machine is not less than 3.0 and must have Back-up heater power of not less than 12 kW and rated power input of not more than 2.5 kW. The heat pump shall have water storage tank of capacity (having internal glass lining) not less than 450 litre. NOTE: (a) Heat pump should have all the safety protections like high/low voltage, high temperature, refrigerant leak, compressor overheat protection with operational noise level not more than 60 dbA. (b) Heat pump should have a user friendly control panel to set the desired temperature with display of the actual temp also with flexibility of installing the same 15-30 m away from the heat pump. 78 Supply, installing, commissioning and testing hi wall split units indoor / outdoor Air conditioner cooling type both complete with cordless remote control unit and within built air purifier, dehumidifier, air filter and dust filter for better indoor air quality with minimum BEE approved, 5 star rating, inverter type, ISEER 5, Electric driven single phase 220 volts, AC, 50HZ, R-410A/R-32 refrigerant of capacity 1.5 Ton, inverter type, noise level should be less than 45 DB including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. class O Nitrile insulation of minimum 12mm thick for condensing unit, copper cable of suitable size for making electric connections, including necessary fixing arrangement (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) complete as specified and as directed. Note:- (a) Suitable piping shall be provided of adequate length of size 5/8 for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Contractor shall submit original purchase voucher and Warranty card. Minimum warranty should be 1 year for complete product, 10 year for compressor, 5 year for condenser and PCB card after Installation and commissioning of complete unit. 79 Supply, installing, commissioning and testing hi wall split units indoor / outdoor Air conditioner cooling type both complete with cordless remote control unit and within built air purifier, dehumidifier, air filter and dust filter for better indoor air quality with minimum BEE approved, 5 star rating, inverter type, ISEER 5, Electric driven single phase 220 volts, AC, 50HZ, R-410A/R-32 refrigerant of capacity 2 Ton, inverter type, noise level should be less than 45 DB including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. class O Nitrile insulation of minimum 12mm thick for condensing unit, copper cable of suitable size for making electric connections, including necessary fixing arrangement (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) complete as specified and as directed. Note:- (a) Suitable piping shall be provided of adequate length of size 5/8 for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Contractor shall submit original purchase voucher and Warranty card. Minimum warranty should be 1 year for complete product, 10 years for compressor, 5 years for condenser and PCB card after Installation and commissioning of complete unit. 80 Supplying, installing, testing and commissioning refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice built-up, automatic adjustment of speed in response to cooling demand, capacity upto 195 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and as directed. 81 Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 5 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed. 82 Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 4 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed. 83 Supplying, fixing, testing and commissioning Industrial cooler (evaporative cooling unit), minimum dia 900 mm, minimum airflow 20000 cum per hour, Axial fan type, Noise maximum 70 decibel, coverage area 100 to 200 sqm, water consumption 65 to 90 liter, UV protected cooler body including 36-liter water tank, standard duct with auto swing grills with all fixing arrangements complete all as specified and as directed. Note: - Industrial sockets and three phase control copper wires shall be measured and paid separately. 84 Supplying, fixing, testing and commissioning Industrial cooler (evaporative cooling unit), minimum dia 900 mm, minimum airflow 15000 cum per hour, Axial fan type, Noise maximum 70 decibel, coverage area 100 to 200 sqm, water consumption 65 to 90 liter, UV protected cooler body including 36-liter water tank, standard duct with auto swing grills with all fixing arrangements complete all as specified and as directed. Note: - Industrial sockets and three phase control copper wires shall be measured and paid separately. 85 Supply, assembly and erection of stainless steel (SS-304 grade) of 0.8mm thick rectangular duct (for industrial cooler) jointed by TIG/MIG welding or riveted with SS flanges with neoprene gasket at joint, supports of MS angle iron or SS rods complete all as specified and as directed. Note: The design of the duct for industrial cooler shall be submitted by the contractor for the approval of the GE. 86 Disconnecting all existing connection including earth wire with transformer of capacity 200 kVA upto and including 315 kVA installed on plinth or 2 poles or 4 poles structures and taking down and shifting transformer from any substation under the GE to new location with help of Hydra (Recovery)/JCB/ Crane etc. and including installation installed on plinth or 2 poles or 4 poles structures at new location including connecting all connections, earthing, conductors, cables, nuts, bolts, washers etc. complete all as specified and as directed. 87 Construction of platform for transformer having dimension (2000 mm X 2000 mm), height 2000 mm and foundation depth of 1200 mm including necessary earthworks in any type of soil, 150 mm moorum filling in foundation, 150 mm PCC foundation with M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate, brick work with sub class B bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick externally in two coats of (15 mm and 5 mm) in cement mortar 1:4, enclosed spaces filled with moorum, 75 mm PCC subbase of flooring with M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate, 150 mm PCC flooring with M10(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash complete all as specified and as directed. 88 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 630 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 630 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 400 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 320 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCCB rated current (In): 160 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (c) MCB, TPN, 10 kA, C-type, rated current 32 A: -1 No (d) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -4 Nos 89 Srl Item No 15.012 Continued......(E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 4 Nos (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) 3 Phase, 5 kW automatic street light control switch using infrared sensor based twilight/ nature switch for automatic switching of streetlights, consisting of weatherproof powder coated metal box of suitable size, 1 No of twilight/ nature switch dusk to dawn, 25 Amps 3 pole contactor- 1 No, 20 Amps MCB- 6 Nos (3 Nos input and 3 Nos output) including wiring with 10 sqmm copper wiring, IP54 protection grade- 1 No (G) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 90 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 400 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 400 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 320 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 160 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCCB rated current (In): 100 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (c) MCB, TPN, 10 kA, C-type, rated current 32 A: -2 Nos (d) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -6 Nos 91 Srl Item No 15.013 Continued......(E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 92 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 250 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 250 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 160 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 100 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (b) MCB, TPN, 10 kA, C-type, rated current 32 A: -1 No (c) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -9 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-100 Amps with CT and selector switch – 1 No 93 Srl Item No 15.014 Continued......(c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 94 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 250 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 250 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 160 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 100 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCB, TPN, 10 kA, C-type, rated current 32 A: -4 Nos (c) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -1 No (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No 95 Srl Item No 15.015 Continued......(c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 96 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 150 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 150 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 100 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCB, TPN, 10 kA, C-type, rated current 32 A: -2 Nos (b) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -7 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT 97 Srl Item No 15.016 Continued......(F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 98 M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI/CI/PP-R/PVC pipe of any dia/ bore/size complete all as specified and as directed. 99 M & L for earthing complete with galvanised steel pipe electrode 40 mm nominal bore, medium grade, 10 metre length buried directly in ground with top edge of the pipe not less than 1.25 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. 100 Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 63 mm, minimum inside dia 47 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. 101 Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 110 mm, minimum inside dia 82 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. 102 Supply and erect factory made 7 meter long hot dip galvanized (as per relevant IS with average coating thickness 65 micron) octagonal poles conform to IS-2062/ BSEN 10025 with 155 mm dia at bottom and 70 mm dia at top A/F made up of 3 mm thick HT sheet along with foundation type base plate of size 250 mm X 250 mm X 16 mm, foundation bolt 4 Nos of M20 X 600 mm high J type EN8 grade, including 1 meter long hot dip galvanized single arm (swan neck) bracket made up of 40 NB dia GI pipe and including excavation, earth work, PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufacturer’s instructions including marking pole number in letters & figures of size not less than 10 cm height with red colour enamel paint complete all as specified and as directed. Note: - (i) Srl number will be issued by Engineer-in-Charge. 103 Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 2.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 2.5 sqmm cable, one run of 2.5 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 104 Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 100 and nominal outside dia 110 mm as per IS 4984: 2016 including all fittings and fixtures in trenches complete all as specified and as directed. 105 Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 100 and nominal outside dia 90 mm as per IS 4984: 2016 including all fittings and fixtures in trenches complete all as specified and as directed. 106 S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 150, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed. 107 S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 200, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed. 108 S & F factory made rubber coated cement concrete paver block 60 mm thick (M35 grade with minimum compressive strength of 35 N/mm2), manufactured using cement, graded coarse aggregate, , fine aggregates and synthetic rubber layer of 5mm thickness, of approved shape and size (typically 200 mm X 100 mm or equivalent) in approved colour with smooth antiskid finish having, water absorption not more than 6%, abrasion not more than 2% and high slip resistance and in accordance with the provision of IS 15658:2006, IS 10262: 2019, IS 456: 2000, IS 2308 (Pt-l to VIII) and IS 1199: 1959 and laid over 30 mm thick average sand bed , filling joints with fine sand, complete all as specified and directed. 109 Material and labour for construction and laying of kerb of size as directed directly on the road construction site with automatic kerb casting machine (kerb/divider making/laying machine), using M25 (Design Mix) grade cement concrete laid in position to the required line, level and curvature kerb stone cast continuous and making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) at a distance as directed, including making drainage opening wherever required, including necessary excavation/earth work and making good disturbed surface complete all as specified and as directed. 110 Material & Labour for providing and fixing stainless steel (grade X 02Cr19Ni1O, 304 S2, surface finish No. 4 as per IS 6911: 2017) gate made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. 111 Supply and fix punched tape concertina coil made out of cold drawn unalloyed steel wires of dia 2.6 mm having minimum tensile strength of 1670 N per sqmm as per IS 4454 (Part- 1): 2001 with hot dip galvanized as per practice recommended in IS: 2629 and the coatings shall conform to heavily coated hard variety as per table I of IS: 4826 (weight of Zinc coating 230 gram per sqm minimum) and steel strip of size 19 mm X 0.5 mm with hardness of 137 to 187 VPN and zinc coating of 18 to 20 microns, minimum 610 mm dia of coil when closed, (9 kg ± 5 %) weight of coil with 50 turns & 129 Nos clips (without handles and spikes) and minimum 580 mm dia when opened upto 6 metres, stretched to 6 metres for 50 turns during installations complete all as specified and as directed. 112 M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 113 M & L for point wiring for one 3 pin/ 5 pin/ 6 pin 5/15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 114 M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 115 M & L for concealed point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 116 M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 117 S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 6 way with 100 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 118 S & F TPN distribution board 4 way vertical type double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper busbar of suitable rating, with neutral bar and earth bar and cable tie for cable management, IP54 Protection and provision and including MCCB 4 pole upto 160 Amp,16KA as incomer and provision for MCBs as outgoing, dust and vermin proof complete as per IEC61439-3 complete all as specified and as directed. Note: MCBs for outgoing shall be measured and paid separately. 119 S & F blanking plate in DBs of MCB complete all as specified and as directed. 120 Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 121 Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 6 sqmm cable, two runs of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 122 Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 10 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 10 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 10 sqmm cable, two runs of 10 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 123 S & F LED bulb, System Wattage: 9 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): < 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed. 124 S & F LED bulb, System Wattage: 0.5 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): < 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed. 125 Supply, fixing and testing LED batten with battery/Invertor, LED Rating (in Watts)/System Wattage/Rated Power: 20 Watt, Rated Voltage & Frequency: 230V, 50Hz, Luminaire System Efficacy (Lumen/watt): 100, Operating Voltage Range: 140-280V, Power Factor: ≥0.95, Total Harmonic Distortion: ≤30%, Colour Rendering Index(CRI): ≥80, Colour Temperature: 5000⁰-6500⁰ Kelvin, Driver Efficiency: ≥85%, Emergency Time: 3 hour, Ingress Protection: IP-20, Type of Control Gears: Electronic, Working life for LED (as per LM-80 and LM 21 reports): ≥50000 hours, Housing Material: Aluminium Extruded, Front Cover Material: Polycarbonate, Surge Protection of 3.0 kV Internal: Yes, Open & Short Circuit Protection: Yes, Reverse Polarity Protection: Yes, Battery Type: Li-Ion, Battery Backup (in Hours): 3, Emergency Light Output (Lumen %): 50, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 126 Supplying, installing, testing and commission of commercial kitchen stainless steel exhaust, chimney/ hood system having the following components: - (a) Commercial kitchen stainless steel hood (6 feet long/ 2.8 feet wide) of stainless steel 304 grade, double filter absorber type, rust free grade steel, inbuilt with automatic sensor as per OEM specifications. (b) Automatic mode changer (drift air), turbo force 5 HP motor with bird screen for protection against bird and foreign materials, rust free body and plates, automatic shutter function complete metal body (c) Double coated high grade ducting material 40 feet long, high quality material as per OEM specifications Note: The contractor shall design the ducting portion as per the drawings and room capacity of kitchen portion of the drawings and calculate the requirement of ducting and submit the design to the GE for approval. The quoted rate shall be inclusive of all these aspects. 127 S & F 15 mm nominal size, nonrising spindle type fancy angle stop valves, two ways in double control with wall flange, made of cast brass including knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. 128 S & F single lever concealed divertor including bath spout and shower complete all as specified and as directed. 129 S & F 15 mm wash basin mixture, centre hole, mixing hot & cold water, fancy type, cast copper alloy, chromium plated with capstan head, chromium plated, screwed down high pressure, screwed for iron pipe etc and fixed in repairs complete all as specified and directed by engineer in charge. Make : Jaquar Cat No: 5001B or equivalent as approved by the GE. 130 S & F health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed. 131 Supply, installation, testing & Commissioning of Mechanical type incinerator electrically operated, made of galvanised iron of capacity 50 Kg/hour suitable for burning including shredder complete all as specified and as directed. 132 S & F factory made rubber coated cement concrete paver block 80 mm thick (M40 grade with minimum compressive strength of 35 N/mm2), manufactured using cement, graded coarse aggregate, , fine aggregates and synthetic rubber layer of 5mm thickness, of approved shape and size (typically 200 mm X 100 mm or equivalent) in approved colour with smooth antiskid finish having, water absorption not more than 6%, abrasion not more than 2% and high slip resistance and in accordance with the provision of IS 15658:2006, IS 10262: 2019, IS 456: 2000, IS 2308 (Pt-l to VIII) and IS 1199: 1959 and laid over 30 mm thick average sand bed , filling joints with fine sand, complete all as specified and directed. 133 S & F glass mosaic tiles , thickness 4 to 5 mm on floor and on vertical surfaces with Type 3 adhesive as per IS 15477: 2019, in a bed of an adhesive average thickness not less than 6 mm and not exceeding average 12 mm in final bed thickness complete all as specified and as directed. 134 Supplying, installing, testing and commissioning outdoor type compact substation (CSS), factory assembled (non walk type) having 11 kV, 630 Amps, internal arc fault for 20KA for 1 sec as per IEC 61330/62271-200 and comprising as under: - (A) MV COMPARTMENT: 11 KV, 630A, 25KA/3 Sec indoor type non-extensible, SF6 gas insulated Ring Main unit with sealed pressure system criterion in accordance with the IEC: 60298,62271 - 202.IAC category IAC-AFL. The Switchgear includes the following HV cubicles The indoor non -extensible SF6 insulated RMU fully motorised consist of 1No. Vaccum Circuit Breaker with Riser (ICOG type) with self-powered relay for protection of transformer (a) Rated voltage should be - 12 kV (b) Rated power frequenecy voltage - 28 kV (c) Rated lightening withstand voltage - 75 kV (d) Rated current for Ring main feeder - 630 amps (e) Rated current for LBS feeder - 630 amps (f) Rated short time current - 25 kA / 3 sec (g) Rated short time making current -50 kA (h) Ambient temperature (0 deg C to + 50 deg C) (i) Rated internal arc rating - 20 KA for 1 sec for tank and cable box category IAC-AFLR (j) RMU shall be provided with protection CTs rated for 30 / 1amps, class - 10P10 accuracy , 2.5 VA burdan for circuit breaker (k) The feeder shall be self-powered/powered by external source and shall be provided with OC+EF protection for transformer and shall have serial port for communication on modbus protocol. (l) Dead short Circuit life of VI - 40 No 135 Srl Item No 15.053 Continued......(B) TRANSFORMER COMPARTMENT: Supplying, installing, connecting, testing & commissioning mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 250 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available. (C) LV COMPARTMENT: The LV compartment with Degree of protection-IP54 designed for a 50-degree C ambient temperature. The panel is modular, dead front, freestanding, floor mounted and comprises the following equipment : - (a) 1000 Amps, 50kA withstand fault level capacity rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection (b) Air Circuit Breaker (ACB) of rated current 630 A, Rated operational voltage 415 V, Rated insulation voltage 1000 V, 4 Pole, 50 Hz AC supply, Rated ultimate short circuit breaking capacity 50 kA, Rated service short circuit breaking capacity 50 kA, Rated short time withstand capacity 50 kA for 1 second, Rated making capacity 105 kA, Rated impulse withstand voltage of main circuit 8 kV, typical opening time 40 ms, typical closing time 60 ms, thermal magnetic release, manual draw out, overload protection, short circuit protection, earth fault protection (Incomer) (c) Outgoing – (i) 320A, 4P, Thermal Magnetic MCCB-Double Make & Double break type, Ics=25kA - 1 No, (ii) 160A,4P, Thermal Magnetic MCCB-Double Make & Double break type, Ics-=25kA - 1 No, (iii) MCB TPN, 32 Amp, 10 kA- 01 (iv) MCB SPN, 10 kA, 6 to 32 Amos – 4 Nos 136 Srl Item No 15.053 Continued......(d) APFC Panel: Designing, manufacturing, supplying, fixing, erecting, testing and commissioning LT APFC panel with capacitor bank, conforming to IS 16636: 2017, 100 kVAR, outdoor installations, rated system voltage of the panel 440 V ± 10%, rated frequency 50 Hz, 3 phase, 4 wire, delta connected, rated impulse withstand voltage 8 kV, free standing, pedestal mounted, made of cold rolled close annealed sheet of minimum 2 mm thick for the load bearing structure and minimum 1.6 mm thick for door and partition, 50⁰C ambient temperature, IP 54 Ingress Protection, 500 Amp rated copper busbar, metallized polypropylene (MPP) dielectric type, resin filled box type, self-healing type, shunt capacitor as per IS 13340: 2012, switching configuration: 50 kVAR X 1 No + 25 kVAR X 1 No + 10 kVAR X 2 Nos + 5 kVAR X 1 No (total five steps), suitable protection in line with IEC and IS for overheating, over current, earth fault, over voltage, short circuit, thermal overload and over pressure, suitable size power and control cable as per Indian Standards, powder coated in grey colour, including microprocessor based automatic power factor correction controller with human machine interface, cooling fans, capacitor duty contactors, 7% detuned reactors, two earth terminals in the panel and as per the details mentioned below complete all as specified and as directed. and shall be including the followings: - (I) INCOMING: (i) MCCB rated current(In): 250A, ultimate short circuit breaking capacity (Icu): 50 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, suitable for 415 V, 50 Hz AC supply – 1 No (ii) Microprocessor based automatic power factor correction controller (minimum 5 steps)- 1 No (iii) Cooling Fans to be provided for forced cooling (II) OUTGOING: (a) (i) 5 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No 137 Srl Item No 15.053 Continued......(ii) MCCB rated current(In): 15A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 5 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 5 kVAR 7% detuned reactor copper wound – 1 No (b) (i) 10 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 2 Nos (ii) MCCB rated current(In): 20 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 2 Nos (iii) 10 kVAR capacitor duty contactors – 2 Nos (iv) ON indication lamp – 2 Nos (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 4 Nos (vi) 10 kVAR 7% detuned reactor copper wound – 2 Nos (c) (i) 25 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No (ii) MCCB rated current(In): 50 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 25 kVAR capacitor duty contactors – 1 No 138 Srl Item No 15.053 Continued......(iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 25 kVAR 7% detuned reactor copper wound – 1 No (d) (i) 50 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No (ii) MCCB rated current(In): 100 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 50 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 No (vi) 50 kVAR 7% detuned reactor copper wound – 1 No Note: (a) The kVAR rating of capacitor mentioned is for rated voltage of 440 V. However, the capacitor shall be provided for rated voltage of 480 V by enhancing the kVAR rating suitably. 139 Srl Item No 15.053 Continued......Outdoor Enclosure:- The enclosure shall be made of 2.0 mm thickness Galvanized Sheet Steel tropicalized to meet Indian weather conditions including all the partition sheets & doors. The base of the enclosure shall be of 4.0 mm thickness Hot Dip Galvanized Sheet Steel to ensure rigidity for easy transport & installation. The entire Package Substation shall be Factory Assemble & Factory Fitted. The enclosure shall have IP54 degree of protection for HT & LT switchgear compartment IP34 degree of protection for Transformer compartment. The Enclosure to be tested for Internal Arc fault test to the tune of at least 20 kA for 1 second adhering to as per latest IEC 62271-202.The temperature rise test on enclosure for K10 class. The enclosure exterior shall be powder courted. Only OEM make of CSS is acceptable. The compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. The enclosure, RMU and LV Breaker should be of same make for better co-ordination and Note:- Platform to be made as OEM recommendation is including in this quoted rate. (D) ACCESSORIES: (a) Multifunctional meter digital type of adequate capacity showing voltage, current, frequency, power factor, Kilo watt, Kilo watt hour with inbuilt selector switch with current transformer coils for three phase: - 1 No (b) LED indicating lamps (c) Danger Notice Plates for HT & LT 140 S & F telephone socket outlet including metal box complete all as specified and as directed. 141 S & F 1 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed. 142 S & F television antenna socket outlet including metal box complete all as specified and as directed. 143 S & F co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed. 144 M & L for construction of new valve pit/chamber of size 900 mm (Length) X 900 mm (Breadth) X 900 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class B bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed. 145 M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium protection stove enamelling rigid steel conduit as per IS 9537 (Part-II): 1981 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 146 Supplying, laying, installing, testing and commissioning cable laying protection U shape tray of size 100 mm height and 300 mm width, made out of hot dip galvanised iron sheet of 2 mm thick including fixing accessories like cross over, bolt in partition, snap in position, supporting corner, horizontal bend, low elbow, rising elbow, T-piece, tray cover, edge protection, full threaded rod, slotted U channel, round head square neck bolt, flange nut, hinged joiner, screws, fastener, hook, nut, bolt, washer etc. complete all as specified and as directed. 147 Supply, installing, commissioning and testing of washing machine with washer extractor of capacity 60 kg (dry weight per washing cycle) front loading electrically driven including water connection from PVC tank to washing machine as per requirement and drain out pipe from machine to drain complete all as specified and as directed and comprising of following specifications/ accessories/capacity/size and material shall be as per OEM/Manufacturer recommendations: - (i) Industrial washer extractor. (ii)Outer drum/ Inner basket/ outer basket made out of high grade stainless steel sheet of SS304 grade with perforation. (iii) Front loading and unloading open pocket. (iv) Forward and reverse basket rotation. (v) 01 No Heavy duty high spin single phase motor, variable frequency drive type of suitable capacity and 01 Nos driver motor three phase 415 volts variable frequency drive type of suitable capacity. (vi) Suspension with shock absorber and springs. (vii) Fully programmable microprocessor and auto balance while extraction. (viii) Manual dosage of powder detergent. (ix) Door limits electric inter locking and emergency stop for safety and trouble free and operation both manual and auto lock. (x) Aluminium casted pulley and belt. (xi)Main body of full stainless steel 304 grade. (xii)Heater of suitable KW. (xiii) PCC foundation as required shall be as per manufacturers recommendation NOTE: - (a) Contractor shall submit necessary company test certificate and purchase voucher and warranty cards as per recommendation by vender. (b) Testing and commissioning shall be carried out by authorized rep of the firm/company for which no extra payment shall be made. 148 Supply, installing, commissioning and testing of drying tumbler electrically heated suitable for washing machine as per above item having loading capacity of 60 kg per charge Fin type Electric Heater of 48 Kw made out of SS pipe, front loading type, Auto Timed, Auto reveres, Microprocessor controlled with electric motor and electric panel complete. Fully die pressed door, inner basket stainless steel basket of min 503 litre volume, outer body mild steel sheet insulated with glass wool complete all as specified and directed. Note: - (a) The Contractor shall submit necessary company test certificate and purchase voucher and warranty cards as per recommended by vender. (b) Testing and commissioning shall be carried out by authorized rep of the firm/ company for which no extra payment shall be made. 149 S & F stainless steel (SS-304 grade) air grills for air swing and wider coverage complete all as specified and as directed.

Key Value

Document Fees
INR 3000 /-
EMD
INR 897000.0 /-
Tender Value
INR 11.44 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail