Tender For Provision Of Toilet At Sre Building At Air Force Station Arjan Singh Under Ge (Af) Panagarh; 1 M& L for Surface dressing n exc 15 cm deep including site clearance of any type of soil complete all as specified and as directed. 2 Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, taking up/ laying of underground cableand getting out in any type of soil complete all as specified and as directed. 3 Returning, filling in trenches of any type of soil including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. 4 Removing of excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed. 5 M&L for PCC (1:4:8), type D-2 using 40mm graded stone aggregates as in foundation, filling and mass concretecomplete all as specified and directed. 6 M&L for Use & waste of formwork to sides and soffits of floor or roof beam,beam haunchings, girders, bressummers, lintels, catilevers, shelves including sup-ports, overhangs, at also splays between floor and beams etcin rough finished flat surface of concrete complete all as specified and directed. 7 M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to battercomplete all as specified and directed. 8 M&L for formwork to sides of columns, post, struts, piers and stenchions for fair finished surface complete all as specified and directed. 9 M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 10 M&L for mild steel TMT bars 6mm to 10mm diacut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 11 M&L for reinforced cement concrete Type M-25 (Design mix) (20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns etc basement slabs, under-reamed piles and mass concrete complete all as specified and directed 12 M&L for reinforced cement concreteType M-25 (Design mix) (20mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m spane complete all as specified and directed. 13 M&L for reinforced cement concreteType M-25 (Design mix) (20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed. 14 M&L for reinforced cement concrete (1:2:4) Type M-15 (nominal mix) (20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed. 15 Earth filling under floors, spreading, levelling in layers n exc 25cm thick each including watering & well ramming complete all as specified and directed. (Note: (i) Earth obtain from item No 2.00 above shall be filled in this item. (ii) Cost of earth not consider in this item but costof spreading, levelling, watering, well ramming are included in this item.) 16 M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar (1:6) complete all as specified and directed. 17 M&L for brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar (1:4) complete all as specified and directed. 18 M&L for 40mm thick in cement concrete (1:2:4), Type B-0 (using 12.5mm crushed stone aggregate) ofdamp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. 19 M&L for damp proof course applying bitumen blown any grade, applied hot,two coats, to concrete surfaces at the rate of 1.5kg. per sq. m per coat Complete all as specified and directed 20 M&L for Polythene film, black, 50micron laid in floors complete all as specified and directed. 21 M&L for rendering 15 mm thickon concrete/brick surface on wallin cement mortar (1:6) other than fair face of brick work, finished even and smooth without using extra cementcomplete all as specified and directed. 22 M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick or concrete surface , finished even andsmooth without using extra cement complete all as specifed and directed. 23 M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oilemulsion over a coat of alkali resistant primer over a coat of 2mm thick wall care putty complete all as specified and directed. 24 M&L for applying two coats of weather proof exterior emulsion (Anti fungal paint) over a coat of primer including preparartion ofnew plastered surfaces of walls complete all as specified and directed. 25 M&L for hard core of broken stone or boulders of gauge not exc 63mm deposited spread and leveled in layers not exceeding 15cm thick watered and rammed to a true surface complete all as specified and directed. 26 M&L for 75mm thickPCC (1:3:6), type C-2 (using 40mm graded stone aggregates) as in sub base of floorscomplete all as specified and directed. 27 S &F for structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed. 28 M & L for Hand rails, wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for ecuring wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar workonforming to Fe-290 Gde E-165 complete all as specified and directed 29 S&F for pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mmthick of approved colour having tensile strength 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed. 30 M&L for plates Fe-410-W (Gde-E-250) quality-B (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. 31 M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth andapplying two coats of synthetic enamel paint over a coat of red oxide zic chrome primer complete all as specified and directed. 32 M&L for 4mm thick non asbestos fibre cement building board fixed in and including aluminium anodised snap grid frame work as in false ceiling all as specified size of grid 605x605 mm with aluminium main T section of size 36.5 x25 mmx 1.4 mm weighing 0.24 kg per running metre and cross T of size 23.5 x 26.4 x1.4mm weighing 0.191 kg per RM with aluminium wall angle size 40 x 25 x 2 mm including GI supporting wire of 3mm diacomplete all as specified and directed. 33 M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed. 34 M&L for glazedceramic coloured tiles of size 450x350x7mm thick,(premium quality)on vertical surface of wall such as dado, skirting, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick screed bed in cement mortar (1:3) complete all as specified and as directed. 35 M&L for 20mm thick granite stone slab (of any type) work (table rubbed and polished) in skirting/dado, steps, pillars, window sills, cooking platform etc. laid over 20mm thick bedding in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite slab including rounding edges of granite complete all as specified and directed. 36 S&F for solid PVC door frame of size 50mmx47mm made out of 5mm wood grain printed colour PVC sheet and edges will be printed to match with printed sheet, reinforced with MS square tube as per specification and drawing complete all as directed. 37 S&F for 28 to 30mm thick (stiles) Factory Made Solid PVC Moulded Door Shutter with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet polyurethane painted on the front face & 2mm prelam on front face and 2mm prelam PVC sheet on back face and fixed in frame at site as per specification & drawing complete all as specified and directed. 38 S&F for 100 mm long Butt hinges (medium weight) stainless steel complete all as specified and directed. 39 S & F for 150 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. 40 S &F foraluminium alloy, anodised, sliding door bolt 250mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloycomplete all as specified and directed. 41 S & F for 150 mm long aluminium alloy handles, cast type, anodized complete all as specified and directed. 42 M&L for 15mm diabib tap long body with wall flange cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwedfor iron pipe completeall as specified and directed.(Make:-Jaquar, Cat No CON-107KN or equivalent of Hindware/ Kohler/Parryware) 43 S&F for 15mm bore pillar tap fancy type cast copper alloy with capstan heads chromium plated screwed down or high pressure with or without lettered hot or cold with 450mm long braided hoses screwed shank and fly nuts for iron pipe fixedcompleteall as specified and directed. (Make:-Jaquar, Cat No CON-011KN or equivalent of Hindware/ Kohler/Parryware) 44 S&F for 15 mm dia concealed stop cock with fitting sleeves, operating lever & adjustable wall flange with seal (comatible with ALD-083FT& ALD-089FT) valves cast copper chromium platedwith long shank and cup (concealed type) fancy type screwed down high pressure screwed both ends for pipe completeall as specified and directed. (Make:-Jaquar, Cat No CON-083FTK or equivalent of Hindware/ Kohler/Parryware) 45 M&L for 15mm dia angular stop cock with wall flange cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwedfor iron pipe completeall as specified and directed. (Make:-Jaquar, Cat No CON-059KN or equivalent of Hindware/ Kohler/Parryware) 46 S&F for Brass chromium plated towel ring with round flange complete all as specifed and directed. (Make:-Jaquar, Cat No ACN-1121N or equivalent of Hindware/ Kohler/Parryware) 47 S&F for EWC with wall hang cistern, drainage L bend pipe, gasket and installation kit with PP normal close seat cover, Hinges, fixing accessories and accessories set of size 350mm x 450mm x 395mm S trap including to existing water supply ling and water closet pan complete all as speicified and directed. (Make:-Jaquar, Cat No CNS-WHT-551SNPP184LZ or equivalent of Hindware/ Kohler/Parryware) 48 S&F for corner shelf with bracket complete all as specified and directed. (Make:-Jaquar, Cat No CAN-1173 or equivalent of Hindware/ Kohler/Parryware) 49 S&F for soap dish hold type including chromium plated brass screws and wooden plastic cleats completeall as specified and directed. (Make:-Jaquar, Cat No AKP-35731P or equivalent of Hindware/ Kohler/Parryware) 50 S&F for CP brass health faucet of 8mm dia, with 1.2 mtr long flexible tube and wall hook with back flow preventer including all fittings complete all as specified and directed.(Make:-Jaquar, Cat No ALD-573 or equivalent of Hindware/ Kohler/Parryware) 51 S&F for 600x450mm bevelled edge mirror of selected quality glass with PVC packing as approved by GE fixed to wall/ wall tiles to silicon paste including necessary fixing arrangement complete all as specified and directed. 52 S&F forvitreous China wash basin table top, white, flat back, size 425mmx 425mm x 145mm including bottle trap of size 32mm with 250mm & 190mm long wall connection pipes and wall flanges (but exclusive of fixing of supply waste pipe, tap) completeall as specified and directed. (Make:-Jaquar, Cat No ONS-WHT-01901 for table top basin, Cat NoALD-769L250X190 for bottle trap or equivalent of Hindware/ Kohler/Parryware) 53 S&F for vitreous china urinals (top inlet) of size 345mmX320mmX610mm, white with fixing accessories, bowl type, complete including providing and fixing plus, bedding urinal against wall in cement mortar (1:2) securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement, fixing with flush pipe, grating and Union for discharge pipe with grating and union for discharge pipe including connecting to waste pipe and flushing cistern with rectangular shaped urinal partition inlcluding froshed glass of 8mm/10mmfinish chrome size 450x 900mm complete all as specified and directed. (Make:-Jaquar, Cat No URS-WHT-13257 for urinal, Cat No JSE-CHR-110US450X for glass partition or equivalent of Hindware/ Kohler/Parryware) 54 S&F for PVC connection 15 mm dia withPTMT nuts of length 450mm at both ends screwed for iron pipe of 15 mm bore completeall as specified and directed. 55 S&F for 15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors completeall as specified and directed. 56 S&F for 20 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors completeall as specified and directed. 57 M&L for 75mm bore PVC (SWR) floor/Nahani trap, plain with grating including jointing with solventcement complete all as specified and directed. 58 S&F for 75mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints laid in floors or trenches complete all as specified and directed. 59 S &F for 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified. 60 S&F for 110mm dia PVC (SWR) pipes type B single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed. 61 S&F for 110mm bore PVC SWR vent cowl with access door complete all as specified and directed. 62 S&F for Rotational moulded polythylene water storage tank (ISI marked of multi layer) with float valve, plastic lid cover, cylindrical vertical with closed top, hoisted and fixed in position of capacity 500 ltrs including 15mm bore ball brass valvewith union (two nos each)screwed for iron pipe and fixedcomplete all as specifed and directed. 63 Supply and laying of salt glazed stone ware drain pipe grade A 150 mm bore laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed. 64 M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of salt galzed stone ware drain pipes for 150mm dia bore after they are laid and tested complete all as specified and directed. 65 M&L for cement concrete type B-0,(1:2:4) (12.5mm graded aggregate) as in coping, surface channel of drain and manhole including necessary formwork and weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. 66 M&L for precast RCC (1:2:4), type B-1, (Using 20mm Graded Stone Aggregate),set in Cement Mortar (1:4) as in landing, cover slab (for manholes, septic tank/soak well) including placing in position and similar work including necessary form work complete all as specified. & directed. (Note: Reinforcement shall be measured and paid separately.) 67 M&L for 75mm thick PCC type C-2 (1:3:6), (using 20 mm graded stone aggregates) as in plinth protection, pavement etc. and finshed the surface even and smooth without using extra cement complete all as specified and directed. 68 M&L for chequered cement concrete tiles of size 30 cm x 30cmx22 mm thick set, jointed in neat cement slurry in floor and pointed in white or grey cement and no pigment of machine pressed to match the shade of tiles laid over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. 69 M&L for PCC (1:3:6), type C-2 using 20mm graded stone aggregates as in surface channels and drain work including necessary formwork complete all as specified and directed. 70 S&F for 100 mm dia stainless steel gratings with/without waste hole, fixedcomplete all as specified and directed. 71 S&F forfactory made uPVC white colourfixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mildsteel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mmsize for fixing frame to finished wall, plastic packers,plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealantover backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. ( cost ofGlass shall be included in this item). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 72 M&L for point wiring for one light point/fan point/exhaust fan point controlled by one-one way 5/6 Amp switchwith 1.5 Sqmm. (nominal area) single core FRLSH,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid PVCcasing and capping of 25mm with (Medium grade double locking system)complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLSH, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making goodthe diturbed surfaces compete all as specified and directed.(Note:-(a) Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)(b) Quoted rates shall be deemed for casing and capping & accessories, cover plate and box of suitable module, cutting chases of wall etc. and making good disturbed wall.) 73 Description all as per srl item No. 72 above but for socket outlet 5/6 Amps on same board complete all as specified and directed. 74 Description all as per srl item No. 72 above but for one 5 pin, socket outlet, 5/6 Amps on independent board complete all as specified and directed. 75 S&F for switch modular typeone way 6 Amps 230 volts, with one module, complete all as specified and directed. 76 S&F for socket shuttered modular type6 Amps , 2/3 pin combined, 230 volts, with two module, complete all as specified and directed. 77 S&F for ceiling rose 3 phase, PVC/polycarbonate isolated body surface bakelite2 to 3 terminals fixed to wall/ceiling complete all as specified and directed. 78 M&L for MCB, SPN, 240 volts, 40-63 amps with rupturing capacity 10 KA, C curve, including providing thimble for out going cables complete all as specified and directed. 79 M&L for MCB, SP, 240 volts, 5-32 amps with rupturing capacity 10 KA, C curve, including providing thimble for out going cables complete all as specified and directed. 80 S&F for PVC exhaust fan of 250mm sweep, 220-240 Volt, 50 Hz with thermal overload protection (Approve by GE)and louvers shutter completeall as specified and directed. (Make : Crompton Brisk Air/ Bajaj Maxima/ Havells Thrill Air/ Atomberg Efficio)(Note:- (i) Purchase voucher having GST No submitted by the contractor before claiming any paymet duly verified and defeced by the Engr-in-Charge(ii) Two years warranty shall be given by the appoved company of exhaust fan and contractor also) 81 M&L for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in andincluding LED tube light (4ft) connection complete prewiredand connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete all as specified and directed. (Note: Material required for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost). (Make: Havells, Cat No. LUMILINENXTBS20WLED865SPCWH or Crompton, Cat No. TCS-104-20-65-SL-DP-NWH or equivalent in Philips) 82 M&L for LED Tube light fitting, complete with 1x10 watts, 220V, AC CCT 6500K, smart extruded with driver, holderandincluding LED tube light connection Aluminium LED pattern (2ft) with higher effect complete. Microwave sensor to save more energy. Reduce the light intensity by 70% during non occupancy with three code flexible copper conductor cable suitable size from ceiling rose and necessary fixing arrangement at any height complete all as specified and directed. (Note: Material required for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost). (Make: Havells, Cat No. LUMILINEPLUSBS10WLED865SPCSSIND or Crompton, Cat No. CCS-103-10-65-SL-DP-NWH or equivalent in Philips) 83 M&L for sheet metal enclosure MCB distribution board, Single door (metal) single pole and neutral with IP-43 and IK 09 protection single phase 240 volts 4 way, including suitable size copper bus bar of 200 amp and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification completeall as specified and directed. (Note:-MCBs will be measured separately.) 84 S & F for modular white cover palte with frame, 3 module complete all as specified 85 S & F for modular white cover palte with frame, 6 module with blank switches as required complete all as specified 86 M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed.(Note: Punned thickness of sand shall be measured and paid). 87 M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat,size 230mm x 115mmx 75mm, complete all as specified and as directed. 88 M&L for 32mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for cable protection completeall as specified and directed. 89 Supply,laying, jointing and testing,XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sqmm 2 core laid in trenches/ on wall, ducts, pipes, on poles and connection with necessary cables lugs, glands, suitable for mild steel saddle clips (were cable laid in ceilings/wall without cable duct) nut bolts complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).