Tender For Construction Work Of An Auditorium With A Capacity Of 800 Persons On 10,000 Sq. Meter Vacant Land In The Government Inter College Campus Near Mahavir Chowk In Muzaffarnagar District Under The Jurisdiction Of Development Authority Muzaffarnagar. - Construction Of Auditoriume building At Muzaffarnagar (Up). - EXCAVATION WORK 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge. All kinds of soil 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil 4 1.50 -3.0m 5 Diluting and injecting chemical emulsion for post-constructionai anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With chlorpyriphos/lindane E.c. 20% with 1% concentration 6 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 7 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 8 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 9 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 10 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). 11 Providing & applying a coat of residual petroleum bitumen of grade of Vg-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 12 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,portland pozzolana / ordinary portland /portland Slagcement,admixtures in recommended proportions as per iS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. concrete of M25 grade withminimum cement content of 330 kg /cum 13 All works upto plinth level Concrete of M25 grade withminimum cement content of 330 kg /cum 14 All works upto plinth level Concrete of M30 grade withminimum cementcontent of 350 kg /cum 15 All works above plinth level upto floor V level. Concrete of M25 grade withminimum cementcontent of 330 kg /cum 16 All works above plinth level upto floor V level. Concrete of M30 grade withminimum cementcontent of 350 kg /cum 17 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 18 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine 19 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A. 20 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 21 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts 22 Centering and shuttering including strutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 23 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 24 Centering and shuttering including strutting, propping etc. and removal of form for Shelves (cast in situ) 25 Centering and shuttering including strutting, propping etc. and removal of form for Weather shed, chajjas, corbels etc., including edges 26 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick 27 Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls Under 20 cm wide 28 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (plan area to be measured). Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) 29 Centering and shuttering including strutting, propping etc. and removal of form for Cornices and mouldings 30 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 31 Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: In one coat 32 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-iii) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 33 Providing & Fixing Materials GRC Materials Jali upto 35-40mm thick as per Drawings Approved by Site in-charge 34 Providing & Fixing GRC Tree Size upto Length 4.00xHeigh4.00mtr.as per Drawings Approved by Site in-charge 35 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo-mechanically treated bars of grade FE-500D or more. 36 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. asrequired. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 37 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 38 Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet conforming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). 39 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 40 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 41 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar I:4 (l cement : 4 coarse sand) 42 Providing and laying Autoclaved Aerated concrete(AAC) blocksmasonry with 150mm to 300 mm thickwith Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3)in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 43 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 44 FINISHING WORK 45 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 46 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 47 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 48 Surface Preparation - Exterior surface cleaning / Sanding using recommended tools. 49 Home Sheild Waterproof Putty – Applying 2 coat of the HS Waterproof Putty is a premium quality white cement-based putty that is damp proof and has some unique properties ,Cured surface after waterproofing with wall putty provides excellent hydrophobicity, exhibiting “Lotus Bead” effect 50 Damp Stop Duo Primer - Applying 1 coat of HomeShield Dampstop Duo primer using a Graco sprayer is a fast and efficient way to get a smooth, even base coat.it is a specially formulated premium quality acrylic primer with superior alkali, damp and efflorescence resistance properties both from positive and negative sides of the wall. Long lasting waterproofing warranty of 7 years on Exterior wall application & 2 years on Interior wall application (T&C applied) 51 Exterior with Longlife 10- Applying 2 coats of Long Life 10 Luxury Exterior paint using a Graco sprayerluxury high-performance exterior emulsion specifically formulated for long-lasting protection and aesthetic enhancement of external surfaces. This product features advanced PU Silicon Technology, offering superior performance under extreme weather conditions and upto 40% dilution on suitably primed/basecoat applied or painted internal walls and ceilings by roller, brush or spray as per manufacturers recommendations. 52 Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminatedglass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, allcomplete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. 53 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 54 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 55 Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour,T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications. 56 Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall bemoulded ASA (Acrylic styrene Acryloretrite ) or HIP (High impact polystyrene) or ABS havingelectronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge. 57 FLOORING WORK 58 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 59 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 60 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm includingngrouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile600 x 600 mm 61 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundybottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 62 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architecturaldrawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 63 Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with and admixture of pigment to match the stone shade. 8mm thick (mirror polished and machine cut edge) Granite stone of any colour and shade 64 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab upto 0.50 sqm 65 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (Granite work) 66 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 67 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 68 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 69 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Makrana white second quality 70 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Light shade pigment using white cement 71 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread offlame of Class A categorywith property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance indimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 100 mm 72 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class Acategory with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick 73 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorativetype, core of block board construction with frame of 1st class hard wood and well matchedteak 3 ply veneering with vertical grains or cross bands and face veneers on both faces ofshutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 74 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 75 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. 76 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm 77 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper 78 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm 79 Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced withgalvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware,SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleevefor fixing frame to finished wall as perIS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paidseparately. Note:- Structural design proof checked from a Government Engineering Institute,to be provided by the manufacturer for : (i) Siteswith basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii)Sites with structure height more than 20m for all wind speeds 80 Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (55mm & above) x (40mm & above) & sash (30mm & above) x(55mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height upto 1.8m). 81 Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m) 82 Casement door double panel with French (False) Mullion with zinc alloy (zamak) 3D hinges,multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.Using R3 series with frame (55 mm & above) x (50mm & above) & sash (55 mm & above) x (85mm & above) & French (False) mullion (55 mm & above) x (60mm & above). (Height upto 2.5 metre). 83 Fixed window / ventilator without mullion / transom. Using R1 series with frame (33mm & above ) x (35mm& above). (Height upto 0.90 metre) 84 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):(Cost of aluminium snap beading shall be paid in basic item): 85 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) 86 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) 87 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture withmatching wood beading 88 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopperetc.to be paid separately). 89 Providing and fixing in wall lining medium density fibre board IS: 14587:1998 marked, Prelaminated one side decorative lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. complete. 25 mm thick. 90 Providing and laying integral cement base water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm ofcement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC slab adjoining wall upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining heights upto 300mm height including rounding of junctions of walls and slabs. (c) After two days of propoer curing applying a second of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed water proofing compound conforming to IS 2645 and approved by Engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300 x 300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test . All above operations to be done in order and as directed and specified by the Engineer-in-charge with average thickness of 120 mm and minimum thickness at khurra as 86mm 91 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). 92 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 93 For vertical surface two coats @ 0.70 kg per sqm per coat 94 For horizontal surface one coat @1.10 kg per sqm. 95 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase 96 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges, making and finishing the outlet complete. 97 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 98 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 99 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 100 Providing & fixing false ceiling at all heights withGRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laidin true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising ofmain-Trunners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm andsecondary intermediate cross-Tof size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm)i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 101 With semi perforated12 mm thick micro tegular edged GRG false ceiling tiles. 102 Provinding and flixing toilet cubicle systems with 12 mm thic solid Cubicle Board BSL. Action Tesa Boilo (HDF High Density Fiber Board), Allpilastersaretobesupportedbyadjustablefootandnoncorrosiveinserts.Toprail andwallfixingwithandexterior polyamidecoatingguaranteesresistanceto breakage,heat,humidityandchemicals.Thebaseoftheadjustablefootwill be anchoredtothefloorwithaclearanceheightof150mm.AluminumU-Channelwill beusedforthefixingofintermediatepanelstothewall.Thetoiletcubiclesetupshallbe:SmartSeries1.Cubicles (1.00-1.20 W, 1.50m L & 2.0m Height)-W- as persiteXD-as per siteXH-2000mm; DoorsizewillbeW-600mmXH-1800mm2.UMPs-W-450mmXH-900 mmalll SS Fittings complete as per site-in-charge. 103 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Make: Jaquar (FLS-WHT-5353PPZ Rimless Bowl with Cistern For ExtendedWall Hung WC with PP Soft Close Seat cover, Hinges, Dual Flush Cistern Fitting, Accessories Set, Size: 380x650x730 mm) 104 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 105 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 106 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 107 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P.brass pillar tap 108 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia 109 Providing and fixing 100 mm sand cast Iron grating for gully trap. 110 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 111 100 mm nominal dia Pipes 112 150 mm nominal dia Pipes 113 Providing and fixing PVC pipe conforming to IS make working pressure 6kg/sqcm including testing labour T&P and all complete fittings 114 150mm dia 115 100mm dia 116 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 117 20 mm dia (iner fitting) 118 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 119 32mm dia (outer fitting) 120 Providing and fixing gun metal gate valve with C.I. wheel of approved quality {screwed end):. 32mm dia 121 32mm dia 122 Providing and fixing SS Materials bib cock of approved quality conforming to IS standards 15 mm nominal bore QQP-7037PMBib Cock with Wall Flang Jeaquar Make:- Jaquar 123 Providing and fixing SS Materialsbib cock of approved quality : 15 mm nominal bore FLP-5037PM Bib Cock with Wall Flange Make:- Jaquar 124 Providing and fixing SS Materials stop cock of approved quality : 15 mm nominal bore FLP-5083KPMExposed Part Kit of Concealed Stop Cock & Flush Cock with Fitting Sleeve, Operating Lever &Adjustable Wall Flange with Seal (compatible withALD-083, ALD-089 & ALD-081) Make Jaquare 125 Providing and fixing SS Materials FLP-5281PM Wall Mixer 3-in-1 System with Provision for both Hand Shower and Overhead Shower Complete with 115mm Long Bend Pipe, Connecting Legs & Wall Flange (without Hand & Overhead Shower) Make : Jaquare 126 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter 127 Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 128 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 129 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 130 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 131 Providing and fixing 600x450 mm beveled edge mirror of superior glass (ofapproved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 132 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 15 mm nominal bore 133 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x460 mm bowl depth 200 mm 134 Providing and fixing C.P. brass angle valve for Basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 135 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 136 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern 137 Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern 138 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 139 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 140 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 12.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 141 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) 142 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 143 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 144 Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge 145 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 146 Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge. 147 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. 148 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, j ointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making j oints with or without grooves (thickness of j oints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 149 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 150 Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment) 151 Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment). 152 Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge 153 Complete maintenance of trees (Out side garden features), jobs like making of basin at regular interval i/c watering, weeding, pruning & application of fertilizer etc, (excluding the cost of material which shall be supplied by the department and other T & P material/articles shall be provided by the contractor) and as per direction of officer in charge. Trees for 250 no/(up to 4 & up to 3 year Slow & Fast growing group) 154 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) 155 Trees Plant 156 Shrubs Plant 157 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : HOLES 45CM DEEP, 45 CM DIA 158 Providing and stacking of Ficus blackii (F.vivion) (bushy) of height 150-165 cm. with 8-10 branches and healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge. 159 Providing and stacking of Gardenia jasminoides of height 45-60 cm. with 34 branches in earthen pots of size 20 cm as per direction of the officer-in-charge. 160 Providing and stacking of Cestrum nocturnum (Raat ki Rani) of height 60-75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge. 161 Providing and stacking of Hamelia patens of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge. 162 Providing and stacking of Hibiscus rosasinensis of height 45-60 cm. with 3-4 branches in earthen pots of size 20 cm as per direction of the officer-in-charge. 163 Providing and stacking of Murraya exotica of height 45-60 cm. in poly bags of size 15 cm as per direction of the officer-in-charge. 164 Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge. 165 Providing and stacking of Tecoma stans of height 45-60 cm. branched in earthen pots of size 20 cm as per direction of the officer-in-charge. 166 Providing and stacking of Ipomoea purpurea (Morning glory) of height30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 167 Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. 168 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 60 cm dia, and 60 cm deep 169 Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge. 170 Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 171 Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 172 Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v 173 Providing and stacking of Ficus infectoria (Pilkhan) of height 150-165 cm. in big polybag of size 25 cm as per direction of the officer-in-charge. 174 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) 175 Supplying and laying of following size Water Line (DWC SN-4 Cass pipewith Integral socket confirming to IS 16098, Size As Per DWG.) marked along with all accessories like socket, bend, couplers etc.complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 176 150mm dia Pipe 177 200mm dia Pipe 178 Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layersnot exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 179 Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329: 180 100 mm dia Ductile Iron Class K-9 pipes 181 150 mm dia Ductile Iron Class K-9 pipes 182 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : 183 100 mm diameter pipe@ 5.0mc/c 184 150 mm diameter pipe@ 5.0mc/c 185 Providing and laying S&S C.I. standard specials such as tees, bends, collars, tapers, caps etc. (Heavy class) Up to 300 mm dia 186 Providing and laying S&S C.I. Standard specials suitable for mechanical jointing as per IS : 13382 Up to 300 mm dia 187 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 188 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testingof joints complete as per direction of Engineer in Charge. External work 189 25mm nominal outer dia pipes 190 50mm nominal inner dia pipes 191 40mm nominal inner dia pipes 192 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 193 20mm nominal bore 194 25mm nominal bore 195 Providing and fixing gun metal gate valve with C.I. wheel of approved quality {screwed end): 196 25mm nomiinal bore 197 32mm nomiinal bore 198 50mm nomiinal bore 199 40mm nomiinal bore 200 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 201 50 mm dia 202 80 mm dia 203 Provideing and fixing C.I. Sluice Valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separtely): 204 100mm diameter 205 Class II 206 150mm diameter 207 Class II 208 Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 209 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming to IS : 4885 210 Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With Sewer bricks conforming IS : 4885 211 Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming IS : 4885 212 Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : With Sewer bricks conforming IS : 4885 213 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 214 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 450 mm dia RCC pipes. 215 SUB HEAD : RAIN WATER HARVESTING WORK 216 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 217 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 218 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia 219 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 220 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 221 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 222 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 223 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 224 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia 225 Supplying, Installation, testing & Commissioning of STP/ETP of appropriate technology including civil work (except plant room), tertiary teratment etc. for the building /campus 226 Plant Size upto 50KLD 227 Add extra for every KLD for plant size above 50 KLD and upto 100KLD 228 Supply and buring of Safe earthing electrode T- 19 (Hot Dip Galvanzid), Lengthup to 3000 mm, outer dia 50 mm inner Dia 25mm. , terminal Dia 12 mm, outer GI pipe of 16 swg. And inner GI pipe of 12 swg with Hot Dip Galvanzization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducingthe soil resistivity with good mixture of retaining capacity and one earthing lead of 25 mm x 3 mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. Strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housingSI. no. 725(B) SOR 2018 229 Supply and Fixing of 16 Sqmm 4 core AL conductor PVC insulated and and serve sheathed round cable 1000 Volt grade at depth of 750 mm below ground level over and cushion of 75mm thick sand all round and protected…………….etc complete. SI. 501 (I) Sor 2014 230 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 16 sq. mm 231 S&Fof 320 A. 415 VHeavy Duty Double Break HRC fusetype metal clad TPN complete with HRC fuse etc. on angle ironframe complete in all respect. 232 Transportation ofdrilling equioment and other accessories to site of work all complete. 233 Drilling tube well by R.C. /method/ Rotory rig 400-500 mm. dia hole all complete as directed by E/I 234 Supply owering & Fixing of M.S. blind or slotted pipe along depth as per requirement of site including cuitting the pipe welding of pipe socket etc.including supply of all material abour T&P etc. all complete. 235 200 mm. dia housing pipe (blind) plain. (5.3 mm thickness). 236 200mm. Dia slotted pipe plain (5.3 mm thickness). 237 Supply & pouring of pea gravel 1.6 mm size surrounding bore well after washing & sceaning as per direction by E/I. 238 S/F of 200 mm dia approved quality bail plugh etc. 239 S/F of 200 mm dia approved quality well cap etc. 240 S/F of 200 mm. dia pipe socket of approved quality. 241 Development by air Comprassior of tube well including labour, T&P etc. all complete. 242 Development by Generator deiven O.P. unit of tube well including labour T&P etc. all complete 243 Transportation of devlopment equipment and O.P. Unit D.G. set all complete. 244 Collection & Sampling of stratar cutting …….etc all complete. 245 Water arrangement charge for drilling the tube well all complete. 246 Supply and Fixing of 80mmx80mmx80mm dia G.I. Tee including labour T&Petc. All complete. 247 Supply and lawring of 12.5 HP 7 stage,61 mtr head (discharge 710 LPM), 3 phase 440 volt A.C.operated motar pump set ISI Marked complete with all taxes etc. as per direction of E/I. make varuna KSB& Crompton with all taxes etc. as per direction of E/I. 248 S/F of M.S. clamp 80mm. Dia with 80x10mm. Plate iron to hold pump set into tube well with Nut bolt etc. all complete. 249 S/Laying of 2 No. (3 core 6 mm 2)size flat submersible cable with connection complete in all respect. (Finolex make) 250 Supply and lawring of 80mm dia ( 3) UPVC column pipe ISI marked (each pipe having 3 mtr. Length) heavy duty red screen self pulling load capacity 6000 Kg, Self allowheel hydrostatispressure 25 KGF/per Sqcm. Including inbilled standerd socket and rubber oaring including all taxes as per direction of E/I. 251 S/F of control pannel board suitable for 12.5 - 15 HP 3 Phase submersible pump motor set including 1 No. 0-500V volt meter 1 No. 0-30 Amp. Ammeter AE make, 3 no. 63 AMP. Fuse unit 3 no. indicator lamp & one number oil field star delta motor, starer make Bentex. etc complete 252 Supply fixing and testing of C.I. double flange bend suitable for 80 mm dia M.S. pipe. All Complete with nut bolt, rubber packing piece etc all. 253 Supply fixing and testing of C.I. Sluice valve of 80mm.dia approved quality with nut rubber packing piece etc. all. 254 S/F of reflex valve 80/100 mm dia size 255 Water logging testing of bore well for Water quality in starta all complete. 256 Supply of 2 tonne capicity 4.5mtrlift M type spour geared cjainpully block 257 Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect 258 Providing and Fixing of Stretch HUSH wall fabric system, By using Hush Fabric of size 1400mm width, shall be stretched by using wooden base 10mm thick and rigid vinyl Stretch Tracks full wrap 15mm (FS15) and Midseam 15mm (FS15), strand board, synth PF infill with requisite accessories & tools strand square edge magnesite bonded finewood fibre panels of size 600 x 1200 x 15 mm having density 400 Kg per cum and weight 4 Kg or more is fixed to existing frame work in between vinyl tracks with suitable fasteners Synth PF 10 x 10 mm thick shall be pasted on strands panels using suitable adhesive. Installation- Wooden base 10mm is installed along the marking lines with metal fasteners inserted at 300mm centers. FS15 fullwrap tracks to be installed on wooden base, at free edges,after applying adhesive on both surfaces for a true and continuous secure grip, and heavy-duty fasteners at 150mm centers on one/both sides of Stretch Tracks.Track outer corner should be installed on woodenbase at corners of column projection.Fabric of width 700mm is then aligned to the Stretch tracks by following the fabric thread line or pattern. The fabric is stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note -minimum 50mm additional fabric is required for tucking hence maximum module wall fabric width would be 1600mm. The fixing need to be approved from Engineer in charge as per approved design of panels & requirement at site. Nothing extra shall be paid and only finished panelling area shall be measured for payment. 259 Providing and Fixing of ‘Wooden Slats’ 2430x131 mm with thickness of 16 mm MDF backed with acoustical Fleece providing sound absorption of NRC 0.70 tested as per IS:8225- 1987.To be installed with 15mm Aluminium profile conforms to Aluminium Alloy 6063-T 6.Temper As per BS:1474-1987 and G.I Lock in clips on the back of tongue and Groove system. The density per panel is 750-800 kg/m3.The panels come with tongue & groove for seamless patterns, 2-14mm Groove and visible panel.Wooden slats are made from acoustical fibreboard with linear perforations for excellent uniformity. The perpendicular holes should be available on the back of panel which are covered by black acoustical fleece.INSTALLATION: ‘Wooden Slats’ can be installed on G.I studs 600x600mm centre to centre 2400mm X 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life with a backing of 50mm thick,1000 GSM Acoustic Wool tested as per Fire Retardant ASTMD 635-1991/Insulation and IS 15061-2002 for excellent results. 260 Providing and Fixing of acoustical false ceiling with perforated Gypsum board(India Gysum) of minimum 10mm tickness with given design and cove for making parterns, cement fiber elgant with accoustic value NRC 0.7. 261 Providing & fixing at all height Stage false ceiling of 20 mm thick Mat Black wood wool sheet(Echomute) panels of size1200 x 600 mm laid over MS Suspension Grid consisting of 2 nos 40 X 40X 5mm MS Angles(Capital or eq.) (GRID will be taken extra in another item) welded back to back @1200mm c/c & M.S. Tees @ 600mm c/c . 262 Providing and Fixing of gypsum cealing and thickness of 20 mm are made with inorganic binder wood fibre, which in all contribute to its wondering features & provide NRC 0.85 tested as per IS:8225-1987 (Equivalent to ISO: 354- 1985 & ASTM 423-90). Panels are an ecological green material. It is non flammable as per IS:3614 (Part-II). It facilitate fast, rapid construction of walls & roofs.Panels can be installed with Coloured Aluminium H Profile on G.I studs 2400mm X 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life with a backing of 50mm thick Acoustic Wool tested as per Fire Reatrdant ASTMD 635-1991 and IS 15061-2002 for excellent results. 263 Providing and fixing 100% Polypropelene Stainsafe carpet having following characteristics : Pattern Loop Graphic, Primary Backing : Woven PP Secondary backing : Dimenstionally stable woven Action back Pile eight/thickness : 6mm(+/-5%), Pile weight : 850gm/sqm (tolerance -5%) or more Light fastness : >5 Water esistance 4-5 Fire Class : Efl (EN13501-1) Characteristic : Bleech resistant Width : not less than 3.5m The carpet shall be of make Milliken / Interface / Unitex / Divine / Checkmate or quivalent. Carpet to be installed over with 8mm thick PU foam over CC / kota flooring, fixed with approved synthetic adhesive SR-505 (Qty minimum one litre per 3 sqm for both foam& carpet) or as recommended by anufacturer of carpet, the colour and pattern of carpet as approved by engineer-in-charge all complete (Note : The cost of 6 mm thicknes PU foam, adhesive & other incidal items included this item) 264 Providing and fixing of Auditorium Chair in position, Heavy Duty ergonomically designed auditorium chairs which have gravity type, spring free TIP-up (without any stop or time lag) and rocking back with central Pedestal. The chairs shall be fully upholstered having Wooden Laminated Back on back side. The Chair shall be fixed as per approved layout, which is to be submitted by the contractor based on actual dimensions of Auditorium steps measured at site and approved by the Engineer in Charge. The Chairs shall be of sufficient width having placement 570-590 mm centre to centre and height of back should be 1020 (+/- 20) mm. 265 DOOR FRAME: Wooden Door Frame of section 145mm x 75mm or 95mm with heat activated intumescent fire seal strip of size 10mm x 4mm Twino Type Astroflame U. K.) and acoustic seal Raven RP24. DOOR SHUTTER: 77mm thick having 38 dB acoustic cum fire door of 60 / 120 min. fire rating having infill of 47mm thick 3resin bonded glasswool of 24 Kg /M density coated with FR acrylic, including Panic Bar, door closure, stopper and all other accessories required by department. 266 PROSCENIUM: P/F of M S structure ( Capital or eq.) fixing of 12mm ply(Green or Eq.) & final finish with laminate 267 Supply Installation testing and commissioning Stage Flooring 65x15. 2nd class Teak wood planks flooring with Tongue and Groove joints of 22mm thick (concealed screwing) over 50x50mm section Sal wood framing @ 600mm c/c in both directions with 12mm thick commercial ply(Green or eq.).The framing to be filled with 50mm th. fibre glass resin bonded insulation of density 24kg/cum. 268 SITC of Main Curtain made out of Crape curtain cloth with horizontalslidingarrangementcompletewithfixingrails,brackets, slidingarrangement&motorisedoperationcompletewithrunners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton) 2nos.air breaker contactors (L&T/SIEMENS) ,2nos. micro switches forautostop,3nospushbuttonsforforward,reverseandstop positions.The curtain should be draped to half area when in closed position. Minimumoverlapatcentreshouldbe900mmandshould be stitched in double gathering can be operated manually or through remote . 269 SITC of Rear Curtain made out of glazedcotton curtain cloth with horizontalslidingarrangementcompletewithfixingrails,brackets, slidingarrangements&motorisedoperationcompletewithrunners, master runners, pullies, 3mm steel wire rope, 1HP motor (Crompton) 2nos. air breaker contactors (L&T/SIEMENS), 2 nos. micro switches forautostop,3nos.pushbuttonsforforward,reverseandstop positions.The curtain should be draped to half area when in closed position. Minimumoverlapatcentreshouldbe900mmandshould be stitched in double gathering, can be operated manually or through remote . 270 SITC of valance/Frill made out of Crape cloth to be installed above the stage on 25mm dia GI pipe with the 300% gathering of Size. The work shall be executed as per drawings, specifications&instructionsofengineerinchargeinall respect to approved makes. 271 SITC of of WINGSatStagewith Crapebluefabric(weightnotlessthan290gms/sqm fixedcomplete on 50x 25(1.6 mm thick) MS tube framework@ 1200 (V) x600 (H) c/c backed with 6mm ply & 12mm U foam below the fabric. The wing to be mounted with central pivot mechanism for180 degree rotational movementat top & bottom.Size 1.2 mtr (w) x 7.5 mtr (h) approx. The work shall be executed as per drawings, specifications&instructionsofengineerinchargeinall respect to approved makes. 272 Providing and Fixing of Stage Lighting Bar, 50mm dia B class GI Pipe of suitable size fitted with 15 amp. sockets suitable for stage light installation. 273 SITC of Grid frame work with MS pipes of 50x50mm of 14gage with black finish paint for supporting wings and light structure. The work shall be executed as per drawings, specifications&instructionsofengineerinchargeinall respect to approved makes SAIL, TATA, Jindal, APL, Apollo. 274 SITC of Front of House Winch Suspension Systems: Motorized bars winch operated suspension sets min 500 kg capacity, 4 lines block winch unit with handle and ratchet, clew plate and steel wire rope for lifting, etc for lighting bars, scenery sets and front masking frills. The work shall be executed complete as per specifications, directions of the Engineer-in-charge. Make : TDH, Model : Custom Item 275 Providing and Fixing of Side Ladder, 50mm dia B class GI Pipe of suitable size fitted with 15 amp. sockets suitable for stage light installation. 276 SITC OF Two-Way Full Range Loudspeaker with 2 x 10 Differential Drive,Frequency Range (-10dB) 86 Hz - 18 kHz,Frequency Response (±3 dB) 109 Hz – 15.3 kHz, Full Range 800 W Continuous Pink Noise (3200 W peak), 2 hrs 400 W Continuous Pink Noise (1600W peak), 100 hrs, Bi-amp LF 800 W Continuous Pink Noise (3200 W peak), 2 hrs 400 W Continuous Pink Noise (1600W peak), 100 hrs Bi-amp HF 150 W Continuous Pink Noise (600 W peak), 2 hrs 50 W Continuous Pink Noise (200 W peak), 100 hrs Full-Range 80 V Rms (2 hrs), 160 V peak Maximum SPL (1m) 131 dB Cont. Ave (2 hrs), 137 dB Peak Coverage Pattern (-6 dB) Horizontal: 100°. 277 SITC of Dual 15 Subwoofer with Differential Drive, Frequency Range (-10dB) 52 Hz – 210 Hz, Frequency Response (±3 dB) 62 Hz – 123 Hz, System Power Rating 1600 W Continuous Pink Noise (6400 W peak), 2 hrs800 W Continuous Pink Noise (3200W peak), 100 hrs, Maximum Input Voltage 80 V Rms (2 hrs), 160 V peak, Maximum SPL (1m) 127 dB Cont. Ave (2 hrs), 133 dB Peak, Sensitivity 98 dB (52 Hz – 210 Hz, 2.83V), Impedance 4Ω, 3.0Ω min @ 195 Hz. 278 SITC of OEM frame for given speakers and subwoofer for taking relevant load with motorised lift up and down array from flloor. 279 SITC of 15 Loudspeaker for Balcony and underbalcony line arrayable Transducers Low Frequency : 15 Cone transducer & High Frequency 1.75 , Frequency Range (-10 dB) : 44 Hz - 20 kHz, nominal Coverage(-6dB) :90° H x 80° V, Amplifier Power Output : 500W Maximum SPL (@ 1 m) 131dB SPL ,Configuration : 2-way Line array element. 280 Rigging Hardware/ Bracket: Aluminum array frame for same Series enclosures; 281 SITC of Active Stage Monitors Transducers :Low Frequency : 12 Cone transducer & High Frequency 1.4 , Frequency Range (-10 dB) : 45 Hz - 20 kHz, Nominal Coverage Angle :75° Axisymetric, Amplifier Power Output : Class D 1500W, Maximum SPL (@ 1 m) 130dB SPL, Configuration : Multi-purpose, 2-way powered loudspeaker 282 SITC of Front fills Transducers :Low Frequency : 8 Cone transducer & High Frequency 1.4 , Frequency Range (-10 dB) : 45 Hz - 20 kHz, Nominal Coverage Angle :75° Axisymetric, Maximum SPL (@ 1 m) 110dB SPL, Configuration : Multi-purpose, 2-way powered loudspeaker 283 SITC of Control Room & Green Room : Transducers Low Frequency : 6.5 Cone transducer & High Frequency 1 , Frequency range (-10 dB) : 70 Hz - 20 kHz, Nominal Coverage Angle :120° Axisymetric Power handling : 40W or more Transfomer tap settings at 100V: 40, 20, 10 W and 150W RMS at 8Ω bypass Maximum SPL (@ 1 m) 110dB SPL, with respective volume control at each room 284 SITC of Two-channel, 2400W @ 4Ω Power Amplifier, 2400W at 4ohm at each channel, Frequency Response (8Ω, 20Hz - 20kHz) ±0.25dB, Total Harmonic Distortion (at full rated power, 20Hz - 20kHz) 0.35% Damping Factor (20Hz to 100Hz) >5000, Load Impedance (Stereo/Dual Mode) 2Ω - 16Ω; 70Vrms and 100Vrms, Load Impedance Bridge Mono 4Ω - 16Ω; 140Vrms and 200Vrms, Cooling Continuously variable speed forced air, front to back airflow Required AC Mains (±10%) 100V-240V ~ 50/60Hz. 285 SITC of dual channel class D amplifier with 1350W RMS output power at 8Ohm. Frequency Response (4Ω and 8Ω) :20 Hz - 20 KHz +/- 0.1 dB, Signal to Noise (20 Hz - 20 KHz) >100 dB 286 SITC if Multizone Class D amplifier : Number of channels: 1 or more Power output per channel(@8ohm,4ohm) : 500W per channel or more Frequency Response (4Ω and 8Ω) :20 Hz - 20 KHz +/- 0.1 dB, Signal to Noise (20 Hz - 20 KHz) >100 dB, minium 4 zone out to control individual speaker with built in mic and line input. 287 SITC of Analog Mixing Console, 232 Line Inputs (24 mono and 4 stereo), 4 GROUP Buses + ST Bus with 6 AUX Sends + 2 FX Sends, 1 Matrix out, FX1:REV-X(8 PROGRAM, PARAMETER control)/ FX2:SPX(16 PROGRAM, PARAMETER control), MIC: 24 (INPUTS HPF: 100Hz 12dB/oct), 48V phantom power per channel, LINE: 24 mono + 4 stereo, CH INSERT: 24 RETURN: 1 stereo, USB Device, iPod / iPhone, TDH 0.02% (20Hz-20kHz@ +14dBu),Frequency Response +0.5/-1.0dB 20Hz - 20kHz, refer to the nominal output level @1kHz. 288 SITC of Complete Loudspeaker Management System: Input Processing - Compression, AFS™ (Advanced Feedback Suppression), 31-Band Graphic EQ, 12-Band Parametric EQ (with narrow notch capabilities), Subharmonic Synthesis, Backline Delay, Noise Gate, Output Processing : Crossover (supports full range up to mono 6-way systems), 12-Band AutoEQs (8 AutoEQ bands, 4 User bands), Automatic Gain Control, Subharmonic Synthesis, Noise Gate, Tower Delays (up to 1000ms per output), 8-Band Parametric EQs (used for speaker tunings). 289 SITC ofDynamic Super Cardioid Wired Handheld Microphone for speech and vocal,Extended high frequency range,Handles high sound pressure levels,Frequency response (Microphone) 40 - 16000 Hz, Nominal impedance 350 Ω,Sensitivity in free field, no load (1kHz)1,8 mV/Pa. 290 SITC of Dynamic Wired Handheld Microphone with ON/OFF Switch, Rugged metal body,Excellent feedback and spillage rejection, Good suppression of handling noise, Nominal impedance 350 Ohm,Sensitivity in free field, no load (1kHz) 1,5 mV/Pa,Min. terminating impedance 1000 Ohm. 291 SITC of Dual Hand Wireless Microphone with Lithium batteries and recharging cable, True diversity receiver with metal housing ,External antennas. Automatic frequency management and synchronization via ,remote channel for easy setup Fully tunable over a wide range of UHF frequencies ,Up to 12 compatible channels,Power supply 12 V DC nom. / 300 mA ,AF frequency response 50 to 16,000 Hz (–3 dB) 292 SITC of Dual Lapel Wireless Microphone with Lithium batteries and recharging cable, True diversity receiver with metal housing ,External antennas. Automatic frequency management and synchronization via ,remote channel for easy setup Fully tunable over a wide range of UHF frequencies ,Up to 12 compatible channels,Power supply 12 V DC nom. / 300 mA ,AF frequency response 50 to 16,000 Hz (–3 dB) 293 SITC of wired Gooseneck Microphone:AF frequency response 20 to 20,000Hz, Dynamic range > 120dB(A),Signal-to-noise ratio > 90dB(A). 294 Supply and laying of 8 core shielded microphone snake cable for mic points and powered speakers 295 Supply and laying of 2 core 2.5sqmm speaker cable for speakers connectivity. 296 Supply and laying of 2 core shielded microphone cable for mic leads and other signal connectivity 297 SITC of stage box with multi mic inputs and power points. 298 Supply of Microphone Stand 4 small and 4 big Floor/Table Tripod type 299 SITC of Cable Tray Arrangement (40 X 150 X 40 MM) with pouder coating. 300 SITC of 25mm PVC conduting with all joint and bends for cabling laying 301 SITC of all XLR male, female, Speakon, Chassi mount and other necessory connector for final commissioing 302 Supply and Fixing of Equipment rack 36 U with power strip, fan, doors, wheels, drawer for accessoories with lockable facility. 303 STAGE LIGHTING (B) SITC of 54x3W LED par light complete with 8- channel DMX 512, high brightness mixing color evenly, stable performance with sound active auto, DMX, and power and DMX loop in and out option, undergone through 7 Tank chemical treatment to keep them rust free and, duly powder coated in black matt texture finish and technical specifications as below. Lamp - 304 SITC of 200W LED Profile light 19 degree with below specifications :- Lamp Power : LED, 200W Power Supply : AC 110-230V, 50Hz Focus : Manual Focus , Beam Angle : 19° , Dimmer : 0-100% linearly adjustable manually focusable, high quality optical system, glass reflector. DMX Control protocol: DMX 512. , CRI : >90 , Dimming : 305 SITC of Planoconvex Lights :-400W LED PC Light . 400W LED PC Light 30 Degree complete with 3200K/5600K CCT 4x100W Chip On Board LED lamp source, DMX 512 dimming with 4/8 Channel modes, Black finish housing, IP20 protection having Strobe option and smooth dimming, illuminate Stage with uniform light intensity levels 306 SITC of 200W LED PARCAN with below specification : Lamp power - 200W , LED Type : COB LED, Color Temperature 3200K Power Rating - IP 20 , Control Manual , DMX, Channels - 2 channel DMX 512 , Power Supply - 100-240 V AC, 50/60nHz 307 SITC of 200W LED Fresnel Cyclorama Light with 200mm dia German Lens with below specification : Lamp power - 200W , LED Type : COB LED, Color Temperature 3200K ,CRI > 95, spot - Flood Focus adjustment : Mototrised, Beam angle - 10° 50°Power Rating - IP 20 , Control Manual , DMX0-100% through manual and DMX , Channels - 2 channel DMX 512 , Power Supply - 100-240 V AC, 50/60Hz 308 Supply of Moving Head/ SHARPY LIGHT 15R, Voltage: 110V~240V/50-60Hz, Ballast: Electronic ballast, Lamp: YODN 280W R10, Color temperature: 8500K, Life Span: 2000H, Colour Wheel: 14 Color + Blank Color Whee 309 SITC of 200W Warm White with below specification : Lamp power - 200W , LED Type : COB LED, Color Temperature 3200K Power Rating - IP 20 , Control Manual , DMX, Channels - 2 channel DMX 512 , Power Supply - 100-240 V AC, 50/60nHz complete etc. as reqd. 310 SITC of Light fixture mouting clamp Customized for suspending on fixed bars on stage Made up of Aluminium or MS material Complete with black powder coating matt black finish. 311 SITC of V3 Controller - Total 2048 DMX Channel offer4 Individual optical isolated DMX interfaces and 1 Art-Net interface . One high resolution 15 inches capacitive LCD Touch screen. 15 playback faders and 15 playback keys run with 80 pages. 4 backit optical encoders for data settings . The key backit offers three color options and adjustable brightness, playback faders with backit which can be set to different colors for 3 different states.Individual keys for the flash and pause function for playback , provide midi in , out and thru interface to connect and work with other devices. Accept midi time code signal. WiFi antenna provides WiFi signal for connecting App on mobile or tablet. USB 2.0 interface allows you to backup shows on the external disk. Offer one 3.5mm stereo audio interface one audio optical interface and a headphone interface. I Working lamp interface with luminance interface .1 working lamp interface with lumination regulator. Power supply -AC100-240V, 50 -60HZ. 312 SITC of Opto isolated RDM enabled DmX splitter unit provided with 8 Isolated outputs Slow blow safety fuse 5 Pin XLR for output interface Dual mode to select 2 universe operation DmX Input through 5 Pin XLR Connector Powder coated compartment finish Mounting brackets for grid mount 313 SITC Lights point :- Light Point Wiring from Patch Panel to be Light Point Wiring from Patch Panel to bewith 1.5 Sq.mm 3 Core PVC Insulated and PVCSheathed Cable including of suitable size forlaying these wires including 16 amps metallic industrial cladsockets with box at top and FRLS cable 314 SITC DMX POINT:- interconection of signal cable with XLR conector 315 SITC DMX Cable :- 2 core shielded DMX Cable for light 316 SITC of Cove Light with Havells LED strip inside on DC Power 5mV, Along with transculant covered 317 Special Application of LED Step Light for Multiplex Cinema Theatres, Auditorium etc. with a Lamp a life of more Than 2 year amd consume less than 5W. Black anodized profile with anti-slip polymer rubber and riser illumination LED (12/24V DC) available color in blue, white, green, red or yellow. Minimum Length 1.45mtr for Step. With labeling on every alternate row.Quotation Rate 318 SITC of LED DISPLAY : 2.5 mm Pixel Pitch based Indoor Direct View True Color LED Wall Screen Size 36 x 20 feet, Configuration : SMD 3-in-1 LED Type Alluminium Die Cast, Pixel Density : 1,60,000 pixels/m2 or better, Brightness Calibrated : 500 cd/m2 or better, Dimming Capability : 0-255 Levels or higher, Contrast Ratio : 3000:1 or better, Refresh Rate : 1920 Hz or better, Color Processing : 14-bit or better, Colors : 4.4 Trillion or better, Half Gain Viewing Angle : H: ± 80° or better, V: ± 80° or better, Lifetime : 100,000 hrs or better, Indoor P 2.5 , LED Video wall Solution, Modules,Receiving Card, Power Supply, Cable and Connectors etc. Brightness : 500 Nits, Life - 100000 Hours, Module Based Installation, Screen Diagonal In Inch 217LED Wall Resolution 1920 x 1088 With Control System : 4 Inputs Control Systems Module IP 65 with 4 K controller , Resolution support up to 20.8 Million pixels, HDR , HDCP ,3D , EDID support, Seamless switching & scaling, fade in/ fade out, PIP function support size & location, Low latency, Support colour ,Brightness, Contrast, saturation, Grey scale adjustment, Option of Live video on HDMI , Scheduled playback and preset, Support 4:4:4,4:2:2, 4:2:0( RGB/YCbCr), Hot swappable Input/outputs .Signal Input : DVI/ HDMI , Signal Output : RJ45, Input Voltage : 100~240 VAC, Processor : Intel/ARM /Other High End, OS : Android/windows, Internal drive : 8 GB , Video : At least should support MPEG-4,MOV, Audio : MP3,WAV,AAC, with PDU, Wall Mount MS Structure for Video wall. 319 Supply & Fixing of 8x8 Input presentation switcher/scaler with HDbaseT & HDMI simultaenous ouputs with 4 HDMI and 2 computergraphicsVGAinputwithmicrophoneinputand audio embedding and De-embedding with audio equalization.Mixingwithautoinputswitching,supporting resolution up to UXGA/1080P having control over ethernet &builtinwebpages,RS-232andcontactcolsuresfor further controlling in respect of approved makes. 320 Supply, Installation, Testing & Commissioning of HDMI & Control twisted pair/Hdbase T receiver, 4Kresolution support,Input:1xRJ45,Output:1xHDMI,1xControls (RS232/IR) distance support of 70mtrs or more for reception of audio, video, control & power with feature of De- embedded audio. Should be compatible to the multi-format transmitter orScaling Matrix Switcher in respect of approved makes. 321 SITC of Digital Podium :with inbuilt 19 interactive panel with motorized tilting of panel, top connection panel with connectivities such as power for external laptop, VGA input, vga swicther for toggling between visualizer, cpu and external laptop, usb ports for connecting external pen drive directly to the cpu, with builtin I3 -CPU. 322 SITC of WirelessPresentation System: Wireless connection to central screen, Up to 2 users on-screen, Share from laptop, tablet or smartphone, Enhanced security features, Touch back support, Central management, Delivered with 2 Buttons,Operating system Windows 7/8/8.1/10 32 & 64 bit,Video outputs 1x HDMI 1.2, Output resolution 1920x1080 @60Hz, Audio Via HDMI, analog via Audio Jack 3.5mm, S/PDIF, AirPlay Support iOS 11, 12 & 13 / macOS 10.14, 10.15, Google Cast Support Android 9, 10, Frame rate Up to 30fps*, Number of simultaneous connections 16, iPad, iPhone and Android compatibility Sharing of documents, browser, camera for both Android and iOS devices via ClickShare app or using AirPlay / Google Cast. 323 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. Make : D-Link, Model : Cat-6 324 SITC of Accessories: HDMI cable, Ceiling Mount Kit, Power and patch cord. cable and other necessory cables Custom 325 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 326 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /ecessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 327 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 328 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 329 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 330 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 331 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 332 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 333 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 334 2 Pair 335 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 336 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 337 25 mm 338 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 339 Telephone socket outlet 340 TV socket outlet 341 RJ45 socket cat 6 with shutter 342 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 343 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 344 1 or 2 Module (75mmX75mm) 345 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 346 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 347 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 348 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 349 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 350 1 run of cable 351 Wiring for group controlled (looped) light point/fanpoint/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 352 Group C 353 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 354 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 355 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 356 4 way (4 + 12), Double door 357 6 way (4 + 18), Double door 358 8 way (4 + 24), Double door 359 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 360 Single pole 361 Double pole 362 Three Phase & Neutral 363 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 364 25Amp. 365 63Amp. 366 Supplying and fixing 40/63A rating, 415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of Four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent. 367 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 368 100 mm width X 50 mm depth X 1.6 mm thickness 369 300 mm width X 50 mm depth X 1.6 mm thickness 370 600 mm width X 50 mm depth X 1.6 mm thickness 371 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 372 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 373 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 374 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 375 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 376 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 377 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 378 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 379 LED Down lighter (SMD Type) (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required 380 with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 381 Powder coated die cast / Extruded aluminum Body including trim. 382 8 - 10 watt 383 12 - 15 watt 384 SITC of 12W Extruded aluminium batten available in 2ft run length with multiple lumen packages and suitable for surface, wall & conduitounting (with accessories). similar to Philips Type HSN Code MRP (INR) BN 021 LED12S 6500 PSU GR or equivalent. 385 Supply and fixing ofwater tight oblong 10 Watt LED bulkhead luminaire having pressure diecast housing with driver set confirming to IP 65 and above Protection, IK08, High purity / transmisivity UV stablized Non yellowish diffuser/ Reflector for uniform light distribution, ditachable driver set, suitable for 24hrs continuous operation complete in all respect. 1200 system lumen, >120lm/W, PF>0.95, CRI>70,>300V, over voltage protection, 4KV internal surge protection with 5 year warrenty. CAT-AAA 386 LED Batten light (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Testeport from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineerin-Charge as per requirement. (Thermal management: heat sink ofaluminum housing such that LED junction temperature shall not rise above 90°C). 387 Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1.20mm) 388 18- 22 watt 389 LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 390 36W 391 RecessedPIR Motion Sensor Similar to Wipro Make : GLPS01R010HA or equivalent 392 Supply of backlit, 33W SMD LED 2x2 luminaire suitable for Armstrong / CRG /TRAC / USG/Celotex modular ceiling system having luminous efficacy of(3300lm) with dimension of 595mm x 595mm and height of 48mm. The luminaire should be able to be mounted on POP/Gypsum ceiling with the help of additional frame. Luminaire shall be made up of white powder coated extruded Aluminium housing with C shaped opal diffuser. The lumianire should supplied with inbuilt heat sink to provide better thermal management to enhance LED life. Luminaire should comply to LG7 guidelines. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. The luminaire should be IP20 ratedandDali Dimmable The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Integrated type, Isolated, Constant Current operated driver with range 150-270V AC.DaliDimmable Driver Efficiency > 85% & 3 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012.Similar to Wipro Make: LM29-451-XXX-57-XX or equivalent 393 Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 394 Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thickISI Marked G.P.sheet spot welded Four to Eightholes for pipe entryof the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concretingalongwith supply of all material, labour, T&P etc. required for proper completion of the work. 395 Lightning Arrestor: Supply, installation, testing and commissioning of External Lightning wide area protection system based on Eaarly Streamer Emission (ESE) technology. Device shall emit electromagnetic impulse in the form of a streamer into the air microseconds earlier than naturally formed streamers. Device confirmg to NFC 17-102 and UNE 21186 Standards. Appropriate non penetrating mounting arrangement. The device shall be mounted at suitable clear to the highest point on the roof top. (Model selected shall give coverage of 79 M radius @ min 5M height from terrace) 396 Down conductor:Supply, installation, testing and commissioning of 70 Sqmm twisted 19-Strand, bare Cu cable on surface/wall / as per site requirement and complete in all respect. 397 Lightning Counter :Supply and installation of counting the number of lightning strikes without any power supply. 398 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 399 Test Link :Supply and installation of test link in weather proof IP 65 BOX. 400 Supply, installation, testing and commisioning of 2 x 25W LED Aviation abstruction light medium bay type 62, complete with lamp, lamp holder, Condenser necessary connecting wire, 1 X 25 AV with all necessary hardware, accessories as required for complete installation. Rate shall include the cost of necessary steel structures , fixing arrangements in this item. Refer drawing. 401 Online UPS- Input supply: Three Phase, Output supply: Three Phase Supplying, installation, Testing & Commissioning of of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 deg C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swappable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of moduels requird for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt 402 phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant International standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC ( 403 inductor (L) and a capacitor (C)) filters shall be included in UPS cost),extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. Communication RS232/RS485/SNMP port open protocol for BMS 404 integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accoseries are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED ) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. 405 d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage.f)Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load /UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc 406 60KVA (Each Power module shall be < 10 KVA) 407 MAIN L.T PANEL 408 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 50kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 409 The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have Buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers,microprocessor release for overload, short circuit, instantaneous & earthfaultprotection with Current & Voltage metering & LCD display. 410 Air Circuit Breaker with microprocessor release ge metering & LCD display , with ready to clsoe indicator, should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB(Icu=Ics=Icw=65 KA (1 sec).MCCB, with microprocessor release with LSIG protection functionand should not derate upto 50 decree Centrigrate as per testing guideline as per IEC 60947-2 and all the ACB upto 2500Amp ACB should have same frame size LCD display for fault trip history, haivng current limiting feature, double break mechanism & capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics) 411 INCOMING 412 1 Nos. 1250 Amp TPN EDO ACB 25KALSIG having S/C, E/F O/C protection, LCD Display having specs as per attached annexture From 800KVA Transformer havingR,Y,B Phase indication Lamp with control MCB On, Off, Trip Status Indication with control MCBInbuilt Zone Slelective Interlocking function Multifunction Meter 413 1 Nos. 500 Amp TPN Moterized MCCB 25KALSIG having S/C, E/F O/C protection, LCD Display having specs as per attached annexture From 200KVA Solar Power Backup havingR,Y,B Phase indication Lamp with control MCB On, Off, Trip Status Indication with control MCB Inbuilt Zone Slelective Interlocking function Multifunction MeterReverse Power Relay Power Conditioning Device 414 1 Nos. 800 Amp TPN Moterized ACB 25KALSIG having S/C, E/F O/C protection, LCD Display having specs as per attached annexture From 200KVA Solar Power Backup havingR,Y,B Phase indication Lamp with control MCB On, Off, Trip Status Indication with control MCB Inbuilt Zone Slelective Interlocking function Multifunction MeterReverse Power Relay Power Conditioning Device 415 BUSCOUPLER 416 1 Nos. 800Amp TPN Motorized ACB 25KAhaving specs as per attached annexturehavingR,Y,B Phase indication Lamp with control MCB On, Off, Trip Status Indication with control MCB 417 BUSBARS 418 1 Nos. 1600 Amp FP busbars of aluminium alloy as per SLD. 419 1 Nos. 1000 Amp FP busbars of aluminium alloy as per SLD. 420 AUTO OPERATION OF INCOMER / BUSCOUPLERACBs. 421 Load Management through PLC 422 Contactor for Load Management System 423 Auto changeover. 424 Buscoupler switching. 425 Electrial & Mechnical Interlocking. 426 Synchonization through PLC 427 Contactor for Synchronizing System 428 Auto changeover and auto load balancing, load management, auto On and Off of DG set as per load requirement. 429 Buscoupler switching. 430 Electrial & Mechnical Interlocking. 431 OUTGOING 432 1 Nos. 630 Amp TP MDO ACB 25 KA, having specs as per attached annexture havingR,Y,B Phase indication Lamp with control MCBOn, Off, Trip Status Indication with control MCB 433 3 Nos. 630 Amp FP EDO ACB 25 KA, having specs as per attached annexture havingR,Y,B Phase indication Lamp with control MCBOn, Off, Trip Status Indication with control MCB HVAC + Projector Room + Spare 434 2 Nos. 400 Amp FP MCCB 25 KA, having specs as per attached annexture havingR,Y,B Phase indication Lamp with control MCBOn, Off, Trip Status Indication with control MCB FF + Spare 435 2 Nos. 250 Amp FP MCCB 25 KA, having specs as per attached annexture havingR,Y,B Phase indication Lamp with control MCBOn, Off, Trip Status Indication with control MCB L+P + Spare 436 3 Nos. 100 Amp FP MCCB 25 KAOn, Off, Trip Status Indication with control MCB Multifunction Meter STP + PL + Spare 437 2 Nos. 125 Amp FP MCCB 25 KAOn, Off, Trip Status Indication with control MCB Multifunction Meter UPS+Spare 438 6 Nos. 63 Amp FP MCCB 25 KAOn, Off, Trip Status Indication with control MCB Multifunction Meter EX LIGHT + LIFT +Spare 439 Short Circuit Breaking capacity should not less than 50KA. 440 RELAYS AS PER SLD 441 300KVAR HPFC PANEL 442 HYBRID Power Factor Correction SystemSupply, Installation, testing and commissioning of HYBRID APFC Panel, 3 phase 4 wire, 415 V, 50 Hz AC System for Ambient temperature -5°C to +40°C of following capacity with passive solution of 60% capacity and active solution of 40% capacity,3Phase 4 wire Hybrid Power Factor Correction Solution (with arrangment for neutral current balance) to achieve >0.99 lag and TDDI/THDV values within IEEE recommended limits.APFC should be designed as per IS 16636 Or IEC 61921. The active section and passive section shall work in sync to give optimized output. The degree of protection 443 of passive section should be IP 42, and of active section should be minimum IP 21.The switching device for APFC passive section should be through capacitor duty contactor and for the active compensation system shall be IGBT based with 3 level topology having 12 IGBT in inverter circuit. The active compensation system should filter harmonics from 2nd to 50th individual harmonic order and shall be selectable for the entire range. The active compensation system should have feature to improve PF correction and harmonic filtration having response time <25Micro second. The hybrid panel shall be indoor type floor mounted free standing totally enclosed, extensible, fabricated in compartmentalised designed made of CRCA sheet steel of 2.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete with 9 tank process for powder coated of 444 approved shade ( RAL 7032-Siemens gray or as approved by Engineer-in- Charge), having front section (switch gear and control accessories) and rear section (capacitor and reactor), front and rear access, having suitable current carrying capacity, extensible TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus bar supports,bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor andheavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 & 2) APFC Panel shall be in compliance with IS :16636 & CPWD Specifications etc. as per below details. 445 (A) IncomersSuitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp set along with required Instruments and accessories with extended rotary handle and door interlocking arrangement. Current rating of the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating. 446 (B) Instruments & Indicationsi) 3-Phase current sensing APFC microprocessor relay/controller , advance 8/12 stages (8 stages for capacity below 100 KVAR and 12 stages 100 KVAR & above) with Communicationthernet/RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge and havingdisplay of Phase wise V, A, PF, Cos-Phi, Kw, KVA, KVAR, THD-V , THD-I, harmonics up to 31 level. 3 nos of dual core CTs accuracy class 1, 15VA at incomer of PCC Panel for APFC relay. 447 ii) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode. iii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V & I, Frequency.iv) Suitable rating control transformer shall be provided for control andindication circuit. v) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCBs. vi) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS 1100 V grade, PVC insulated multi stranded copper control wire. (C) Bus Bars 1.3 Amp per Sq.mm, TPN, Electrolytic grade Aluminum bus bar of capacity 1.25 times of incomer rating as per CPWD specification. 448 b) For Active Section : Dedicated HMI (Human Machine Interface) (Minimum 7 inch display) for controlling and communication and having display of Phase wise V, A, PF, Cos-Phi, KW, KVA, KVAR, THD-V , THD-I, harmonics up to 50th level.Communication Ethernet/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. 449 300 KVAR 450 Office Building L+P Panel 451 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 50kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 452 The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have Buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers,microprocessor release for overload, short circuit, instantaneous & earthfaultprotection with Current & Voltage metering & LCD display. 453 Air Circuit Breaker with microprocessor release ge metering & LCD display , with ready to clsoe indicator, should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB(Icu=Ics=Icw=65 KA (1 sec).MCCB, with microprocessor release with LSIG protection functionand should not derate upto 50 decree Centrigrate as per testing guideline as per IEC 60947-2 and all the ACB upto 2500Amp ACB should have same frame size LCD display for fault trip history, haivng current limiting feature, double break mechanism & capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics) 454 INCOMING 455 1 Nos. 250 Amp MCCB 16KALSIG having S/C, E/F O/C protection, LCD Display having specs as per attached annexture R,Y,B Phase indication Lamp with control MCBOn, Off, Trip Status Indication with control MCBInbuilt Zone Slelective Interlocking functionMultifunction Meter 456 BUSBARS 457 1 Nos. 250 Amp FP busbars of aluminium alloy as per SLD. 458 OUTGOING 459 13 Nos. 63 Amp FP MCB 10 KA On, Off, Trip Status Indication with control MCBPDB+ACDB +Spare 460 9 Nos. 32 Amp FP MCB 10 KA On, Off, Trip Status Indication with control MCBLDB +Spare 461 Short Circuit Breaking capacity should not less than 16KA. 462 RELAYS AS PER SLD 463 Office Building HVAC Panel 464 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 50kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 465 The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have Buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers,microprocessor release for overload, short circuit, instantaneous & earthfaultprotection with Current & Voltage metering & LCD display. 466 Air Circuit Breaker with microprocessor release ge metering & LCD display , with ready to clsoe indicator, should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB(Icu=Ics=Icw=65 KA (1 sec).MCCB, with microprocessor release with LSIG protection functionand should not derate upto 50 decree Centrigrate as per testing guideline as per IEC 60947-2 and all the ACB upto 2500Amp ACB should have same frame size LCD display for fault trip history, haivng current limiting feature, double break mechanism & capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics) 467 INCOMING 468 1 Nos. 630 Amp ACB 16KALSIG having S/C, E/F O/C protection, LCD Display having specs as per attached annexture R,Y,B Phase indication Lamp with control MCBOn, Off, Trip Status Indication with control MCBInbuilt Zone Slelective Interlocking functionMultifunction Meter 469 BUSBARS 470 1 Nos. 800 Amp FP busbars of aluminium alloy as per SLD. 471 OUTGOING 472 20 Nos. 63 Amp FP MCB + 63 Amp 300mAmp FP RCCB On, Off, Trip Status Indication with control MCBODU +Spare 473 11 Nos. 63 Amp FP MCB 10 KA with 3-5KW S tar Delta Starter With Potential Free Contact to be operated as per Fire Alarm Panel Command On, Off, Trip Status Indication with control MCBVentilation & Pressurization Fan +Spare 474 Short Circuit Breaking capacity should not less than 16KA. 475 RELAYS AS PER SLD 476 UPS Output Panel 477 SITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 50kA as per Single Line Diagram. The Panel shall also be capable to communicate statuslike ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters. 478 The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have Buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers,microprocessor release for overload, short circuit, instantaneous & earthfaultprotection with Current & Voltage metering & LCD display. 479 Air Circuit Breaker with microprocessor release ge metering & LCD display , with ready to clsoe indicator, should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB(Icu=Ics=Icw=65 KA (1 sec).MCCB, with microprocessor release with LSIG protection functionand should not derate upto 50 decree Centrigrate as per testing guideline as per IEC 60947-2 and all the ACB upto 2500Amp ACB should have same frame size LCD display for fault trip history, haivng current limiting feature, double break mechanism & capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics) 480 INCOMING 481 2 Nos. 125 Amp MCCB 16KAR,Y,B Phase indication Lamp with control MCBOn, Off, Trip Status Indication with control MCBInbuilt Zone Slelective Interlocking functionMultifunction Meter 482 BUSCOUPLER 483 1 Nos. 125 Amp FP MCCB 484 BUSBARS 485 2 Nos. 160 Amp FP busbars of aluminium alloy as per SLD. 486 OUTGOING 487 8 Nos. 32 Amp FP MCB On, Off, Trip Status Indication with control MCBUPS DB +Spare 488 Short Circuit Breaking capacity should not less than 16KA. 489 RELAYS AS PER SLD 490 Supply Installation Testing and Commissioning of 400mm sweep 1500RPM energy efficient BLDC fan with double ball bearing for longer life similar to CGE RENESA or equivalent. 491 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) 492 8 way Double door 493 Fire Alarm System : 494 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System)and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. 495 Two Loop 496 Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. 497 Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 498 Supplying, installation, testing & commissioningof intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required. 499 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 500 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 501 Supplying, installation, testing & commissioning of intelligent addressable thermal detectorwith rate of rise cum fixed tempreature thermistor complete with base as required. 502 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 503 Supplying, installation, testing & commissioning of addressable phone control module complete as required. 504 Supplying, installation, testing & commissioning ofaddressable beam detector with short circuit isolator (inbuiltor seperate) complete with emitter and receiver includingconnections with remote test features etc complete asrequired. 505 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 506 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 507 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. 508 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. 509 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 510 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 511 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. 512 Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. 513 Supplying, installation, testing & commissioning of digital audio amplifier 500 Watt, 25V rms operating at 240 Volt AC Supply complete as required. 514 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 515 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. 516 17.5.3.1 speaker cable Single pair, 2-core, 1.5 sqmm 517 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 518 1 Run of Cable 519 Supplying, installing, testing and commissioning of 24 port CAT6 jack panel loaded as per the connections required in jack panel. 520 Supplying, installing, testing and commissioning of I/O(Information outlet ) for CAT6 Cable termination 521 Supplying, installing, testing and commissioning of 6 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts. 522 Supplying, installing, testing and commissioning of 42 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts. 523 S/I/T/C of 24 port 10/100/1000 Base T Standalone Gigabit Switch Make Dlink/Amp with active and passive components, punching, complete in all respect 524 Supply, Installation, Testing & Commissioning of i7 CPU with latest generation windows 10 and above, 1TB SSD and 500GB RAM. 525 Supply, Installation, Testing & Commissioning of CCTV Client Operator Station with 1 No.of 55” LED Display -Complete as per specifications & preferred make. Make: SONY/Samsung/LG 526 Supplying, installing, testing and commissioning of HDMI to HDMI Cable. 527 Supply installation testing and commissioning of 3m Cat-6 patch cord. 528 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm Dia 529 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 530 SITC of 2 MP IR Fixed Bullet Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 531 SITC of64 channel Network Video StoragE NVR suitabe to access data from any remote location including backup drive for 30days. 532 SITC of IP-PBX WITH REDUNDANT CPU & REDUNDANT POWER SUPPLY 16 CO TRUNK, 20 ANALOG EXTENSION, 2 SIP TRUNK, 533 SITC OF BASIC PHONE WITH CLI 534 S/f ofI/O Boxes Krone connectors ,with connection etc. 535 20 Pair 536 Wiringof Jelly Filled telephone Cable in existing pipe for system with connection. 537 20 Pair 538 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 100mm Dia 539 S/F of Surface mount box with I/O Cat 6 and UTP jack D-Link complete in all respect Make Dlink/Amp 540 SITC of 2m long Cat-6 patch cord as required 541 S/I/T/C of 24 port category 6e SL Series fully loaded patch Panel Make Dlink/Amp with active and passive components,punching, complete in all respect 542 Supply, Installation, Testing & Commissioning of Access Enterprise PoE Network Switch: 24 Port10/100/1000 Base-T PoE+ with 4 x 10G SFP+ ports Managed Switch. PoE budget minimum 370W further expandable up to 740W and during the reboot of switch connected end point should get PoE Power. FlexStack-Plus Capability and minimum 8 switches to be stack in single stack; 4GB or Higher DRAM and 4GB or higher Flash, 600MHz Dual Core or Higher CPU; 128Gbps or Higher switching bandwidth; 4K VLAN ID; 190 Mpps or higher forwarding rate; The switch should support Digital Network Architecture and SD Access. The switch should support redundant power supply unit.. The switch should support standard proocols: IEEE 802.1D STP, IEEE 802.1p CoS Prioritization; IEEE 802.1ab (LLDP); IEEE 802.3ab 1000Base-T; IEEE 802.3z 1000 Base-X; IEEE 802.3x Full Duplex on 10/100/1000 Base-T Ports; SNMP v1, V2c and V3; Safety Standards like UL; EN; IEC;EMC; RoHS. 543 Supply, Installation, Testing & Commissioning of Core Enterprise Network Switch: 16 x 10G SFP+ ports and 8 x Gigabit Ethernet Ports Managed Switch. Virtual Stack Capability; 16GB or Higher DRAM and 16GB or higher Flash, 2.4GHz Quad Core or Higher CPU; 480Gbps or Higher switching bandwidth; 4K VLAN ID; 360 Mpps or higher forwarding rate; The switch should support Digital Network Architecture and SD Access. The switch should support routing protocols like static routing, RIPv1, RIPv2, RIPng, OSPF, BFPv4, EIGRP, IS-ISv4, IPv6 Routing etc from day one. The switch should support standard proocols: IEEE 802.1D STP, IEEE 802.1p CoS Prioritization; IEEE 802.1ab (LLDP); IEEE 802.3ab 1000Base-T; IEEE 802.3z 1000 Base-X; IEEE 802.3x Full Duplex on 10/100/1000 Base-T Ports; SNMP v1, V2c and V3; Safety Standards like UL; EN; IEC;EMC; RoHS. 544 Supplying, installing, testing and commissioning of 6 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts. 545 OUTDOOR UNITS: 546 Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 6.4, Capacity > 40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for ECSBC+ Building) 547 14 HP TO 22 HP 548 INDOOR UNIT-4-WAY CASSETTE: 549 Supply, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan /dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc.suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity ofndoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) 550 2.6 TR 551 3.6 TR 552 FLOOR MOUNTED / CEILING SUSPENDED AHU TYPE UNITS 553 Supply oftype VRF typeairhandling units ceiling suspendedwith 24Ga pre coated G.I. outer skin & 24 Ga G.I. inner skin with 40 mm thick PUF insulation of density 42+/-2kg/ m3 horizontal type AHU complete with backward curve. direct driven plug fan with IP 20 VFD, control kit(BHF kit) for AHUEFF-1 motor drive, 4 row deep DX cooling coil. PRE FILTER ,Fine filters , Expansion device. communication kit, with fire rated canvass connection between fan and AHU and between AHU and supply air duct. mixing chamber with fresh and return air dampers. thermal break profile. vibration isolator pad, remote control & with control & expansion kitcomplete as per specifications and drawings with AHU KIT & controller Box 554 6000cfm, 15.0 TRCSU AHU 65 MM St. 555 16000cfm, 40.0 TRCSU AHU 65 MM St. 556 Supply,Installation,testing and commissioning of corded /Cordlessremote controls as per drawing and specifications 557 Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs 558 INDOOR UNITS 559 OUTDOOR MULTI JOINT 560 Supply,Installation,testing and commissioning ofTop of refrigerant gas 561 REFRIGERANT PIPE: 562 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closedcellelastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessoriesasper specifications etc. as required : 563 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 564 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 565 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 566 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 567 19.1 mm dia (OD) (Hard drawn) with tube thickness 1.2 568 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 569 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 570 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 571 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62mm 572 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 573 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 574 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 575 Supply & fixingofcontrol cumtransmissionwiringof 2CX 1.5Sq.mmCopperconductorcable alongwith conduite for looping between indoor & outdoor VRF system. 576 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be erected as directed of following size. 3C x 2.5 sq.mm 577 Supply,installation,testing and commissioning of of CPVC pipes having thermal stability for condesate water including wrapping of 9mm thick class 0 nitrile rubber insulation with suitable adhesive withall CPVC plain and brass threaded fittings including the pipes with clamps 1metre spacing.This including jointing of pipes with one step CPVC solvent cement and testing of joints complete as per drg and specifications 578 50 mm dia. 579 40 mm dia. 580 32mm dia. 581 25 mm dia. 582 Supply,installation testing and commissioning of AIR CURTAIN of following size as per approved make . 583 1200 mm long (High flow type) 584 1500 mm long (High flow type) 585 Supply installation, testingand commissioningof single piece long casing (Motor should completely be accommodated inside the fan casing) Vane Axial Fan (multi piece casing are not acceptable) in GSS/MS with powder coated, Al impeller with adjustable blade angles (Manually Adjustable at Site), bird screen ,gravity louvers, fire retardent flexible connection, necessary nut bolts and directly coupled TEFC Sq.cage induction motor (IE2) H Class insulation for Smoke Exhaust) suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. All offered fans pitch angle shall be AMCA Certified & Listed on AMCA website (Interpolation of pitch angle shall not be acceptable)and Fan Efficiency Grade ( Min FEG 71, lesser is not acceptable).Thickness of the casing shall not be less than: For Dia (300 to 650) mm – 2mm, Dia (700 to 1140) mm – 3 mm, Dia (1200 to 1400) mm – 4mm & Dia 1600 – 5 mm. All fans after assembly shall be dynamically trim-balanced to ISO1940and AMCA 204/3 - G2.5 quality grade. Fan Casing should be provided with Special Designed Integral Straightening Vanes (Vanes should be integral part of casing, it should not be provided separately as an accessory) to reduced turbulence provide high performance & low noise level. 586 Fans for emergency application Tube axial are to be used. Sound level for emergency operation it should not exceed 88 Db(A)@ 3 meter (Room condition).Incase of not achieving sound , attenutor has to be added.Outlet velocity of the fans should not exceed18 m/s for emergency application. 587 Smoke and heat exhaust fans should be tested and certifiedfor 250 Deg C for 2 hour in accordance to standard BSEN12101-3:2015 from TUV SUD PSB Singapore or equivalent internationally recognized fire laboratory 588 16000 cfm ,45 mm E.S.P, 589 Supply,installation,testing and commissioning of Propeller type free discharge exhaustfans complete with motor , fan ,exhaust Louvers as per drawings and specifications. 590 200 mm dia 591 Supply, Installation, testing and Commissioning of ceiling / floor mounted Rectangular box type/circulartype Inline fan, for toilet exhaust , ot exhaust , lab exhaust constructed of GSS duly powder coatedas per detailed specifications, completewith forward curved SISW fan, motor and drive suitable for 220 ± 10% volts, 1 phase, 50 Hz A.C supply, with necessary canvas connection etc complete in all respects. 592 600 cfm at 15 mm static 593 300 cfm at 15 mm static 594 Supply, installation,balancing and commissioning of fabricated at siteGSSsheetmetalrectangular/round ductingcomplete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 595 Thickness 0.63mm sheet 596 Thickness 0.80mm sheet 597 Thickness 1.00 mm sheet 598 Thickness 1.25 mm sheet 599 Supplyingand fixing of followingthickness duly laminated aluminumfoil of mat finish closed cell Nitrile rubber (Class O) insulationonexistingductafterapplyingsuitable adhesivefor Nitrilerubber.The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 600 19mm 601 Supplyandfixingofacousticliningofsupplyairductandplenum with25mmthickresinbondedglasswoolhavingdensityof32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mmcentretocentrecoveredwithReinforcedPlastictissuepaper and 0.5 mm thick perforated aluminum sheet fixed to inside surfaceofductswithcadmiumplatednuts,bolts,stickpins,CPRX compound etc. complete as required and as per specifications. 602 Supplying&fixing of powdercoatedextruded aluminium ReturnAir Grills with louversbut withoutvolumecontrol dampers complete as required. 603 Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers complete as per specifications and size & shape as per site requirement and approved design. 604 Supply,installation,testing and commissioning of flexible duct connections constructed of fire resistance flexible double canvas sleeve as per the drawings and specifications. 605 Supply,installation,testingandcommissioningofVolumecontrol ductdampercompletewithneoprenerubbergaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. 606 Supply, installation, testing and commissioningof Fire damper.in supply air duct / main branch and return air path as and where required of reqired sizes i/c control wiring the damper shall be motorised and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored . the spring return action shall be closed in the event of fire signal complete as required and as per specifications. 607 Fire damper 608 Actuator 609 Supply, installation, testing and commissioning of anodised aluminiumFresh air/Exhaust airlouvers with bird screenas per specifications and drawings. 610 Supply, installation, testing and commissioning of main panel boardoutdoor IP 55 type cubicalFully automatic DOL starter suitable for operating 5.5/7.5 kw motors/fan capacity, complete with contactors,Timer, overload protection relay, current sensing type single phase preventer, ON indications, push buttons, auto / manual / off selector switch,other accessories. complete as required. 611 VRV Unit Panel-FOR OUTDOORUNITS ,FANS & AHUS 612 Supply,installation,testing and commissioning 613 alised floor/wall mounted type made of 2 mm thick 614 steel sheet duly painted complete as per the 615 specifications and drawing and as detailed below : 616 1 no.630 Amps TPN MCCB incomer with KWH 617 meter, phase indicating lamps with control fuse & 618 toggle switch, voltmeter and selector switch, ammeter 619 with CTs and selector switch 620 2 nos. of 40 Amps TPN MCB outgoingwith ELCB 621 8nos. 63Amp FP MCB + 63Amp. 300MAmp. FP RCCB 622 6 nos. of 100 Amps TPN MCB outgoingwith ELCB 623 Supply,installation,testing and commissioning of Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof following size of cable. 624 (a) 3 core 2.5Sq. mm 625 (a-1) 3 core 4 Sq. mm 626 (b) 3 core 6 Sq. mm 627 (c) 3 core 10 Sq. mm 628 (d) 3 core 16 Sq. mm 629 (E) 3 core 25 Sq. mm 630 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables 631 3 1/2 core 240 Sq. mm 632 Providing and fixing approved make Perforated C type cable tray.Made fromsheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall becoated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforationwith coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support( included)as per Specification and as per instruction of engineer in charge.. 633 100 X 50 X 1.6 mm Thick 634 150 X 50 X 1.6 mm Thick 635 300 X 50 X 2.0 mm Thick 636 Supply,installation,testing and commissioning of following double earthing continuity conductor of Cu from Panels to respective equipment on surface or recess as per drawings and specifications. 637 25 mm X 5 mm strip 638 8 SWG wire 639 11 KV DOUBLE POLE STRUCTURE 640 Supply, erection, testing and commissioning of 2 pole structure for providing 1 No. 11KV,200A GOS in accordance with IE rules, & local authority specification and drawings and comprising of the following. 641 a. 2 Nos. 11 mtr. long MS STEEL poles complete with, pole excavation, MS STEEL foundation, and back filling complete MS steel channel/angle iron etc. 642 b. 1 Set of cross arms, branching, clamps and painting complete with GI nut, bolts & washers as required (for GO & DO), LA connection. 643 c .1 set 11KV Insulator complete with spindles & hardware complete as required. 644 d .1 No. 11KV 400A TP Gang operated Air break switches complete with 25mm dia GI pipe operating machanism, handle & locking arrangement. 645 e. 1 set of 3 nos.11KV single pole drop out fuse complete with barrel fuses, and mounting arrangement. 646 f. 1 set (3 nos.) 11KV lightning arrestor and connecting to all phases. 647 g. 4 No. 150 mm dia 6 meter long GI pipe class B (for XLPE cable protection) as required. 648 h. 2 Set 50mm dia 3m long GI pipe earting with 25 x 6 mm GI earth strip complete as required (for GO & DO & LA) 649 i 1 nos. 11KV HT danger boards and 2 set of anticlimbing devices. 650 11 KV Double Pole Structure described below 651 Supply of3 core standered aluminium conductor XLPE(Cross linked polyethylene)insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade as per requirement. 652 240 sq. mm 3 core 653 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 654 Above 120 sq. mm and upto 400 sq. mm 655 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. 656 Above 120 sq. mm and upto 400 sq. mm 657 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 658 Above 120 sq. mm and upto 400 sq. mm 659 supplying and making indoor cable end termination with heatshrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 660 300 sq. mm 661 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 662 300 sq. mm 663 Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality. 664 Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work. 665 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 666 Supply and laying of PVC Insulated, FRLS Round Sheathed Multi Core Industrial Flexible Cable conforming to IS 694:2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade 1100 Volts as per direction of engineer incharge. 667 10CX2.5Sq.mm 668 HT Panel 669 Supply, erection, testing and commissioning of 1 panel, 630A ,11 kV, 3 Phase, 50 Hz., metal clad, dead front, 350 MVA rupturing capacity Vacuum Circuit Breaker Incoming & Outgoings as per the detailed specifications and drawings Outgoings as per the detailed specifications and drawings including connections etc. complete with following in-comers including connections etc. complete with following in-comers and out-goings including door interlocking panel should be expendable type complete as per technical specifications and as required. 670 A. INCOMER / OUTGOING : 671 i) 1 No. VCB having following 672 1 No. 630A, 11kV, 3 Phase, 50Hz., metal clad, dead front, 350 MVA rupturing capacity, Fully Drawout type, Vacuum Circuit Breaker (VCB) 673 1 set of 11kV/110V Potential Transformers with MCB 674 1 Set of Phase indicating lamps with MCB 675 1 No. 0-11 kV Digital voltmeter with selector switch 676 1 set of indicating lamps to indicate OPEN, CLOSE, TRIP,SPRING CHARGED, TRIP CIRCUIT HEALTHY 677 Push button for ON, OFF,TRIP&TRIP circuit healthy 678 1 set of 100/5-5A Current Transformer for metering and protection 679 1 No. 0-100 digital Amps ammeter with selector switch 680 1 Set of CDG 31 (2 No. O/C, 1 No. E/F) relay 681 Digital frequency meter,Digital Tri vector meter. 682 I Set of undervoltage relay and Overvoltage relay 683 Trip circuit supervision relay,Auxiliary relays with shunt trip coil 684 I No. Master Trip relay 685 1 No. Digital Power factor meter 686 Annunciation Window 687 Transformer Protection Relay with WTI/OTI etc. 688 11 KV ICOG 1 Nos. 689 TRANSFORMER 690 11/0.433 KV, 3 Phase, 50 Hz outdoor/ indoor mounting(Mineral oil filled) Supply, installation, testing and commissioning of following capacity (continuous loading) BEE 3 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase,50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to-15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant 691 IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI Marked and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency 692 does not exceed 1.9 Tesla. The permissible temperature-rise shall notexceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40 dg.C for oil and 45 dg. C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shallbe used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not 693 exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminum/ stainless steel material securely fixed on the outer body, easily accessible,as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked. 694 Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); 695 o) Buchholz relay for transformers above 800 kVA. p) Arcing horns orsuitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. 696 630KVA 697 D.G. SET 698 Supply, installation, Testing & Commissioning of Silent Type DieselGenerating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: 699 (A) Diesel Engine:Turbocharged Diesel engine 4 stroke water cooled, multi cylinder,dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital display for following: 700 (i) Start-stop switch with key (ii) Water temperature indication(iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication(vi) RPM indication (vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level 701 (C) Alternator:Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. 702 (D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. 703 (E) FUEL TANK:Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class C pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. 704 (G) Starting System:12V/24V DC starting system comprising of starter motors: voltageregulator and arrangement for initial excitation complete with suitablenumbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. andas per CPWD specifications. 705 (I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 706 1. Suitable numbers and appropriate capacity 4 pole motorisedelectrically operated draw out with cradle type 3 position ACB/ MCCBwith electronic release for O/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Overvoltage relay, 2 Nos. reverse power relay and 2 Nos. under voltagerelay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( L-N & L-L), kW, kVA (Phase & Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set.7. Fuse/ MCB for instruments. 8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. 9. Main supply failure monitor. 10. Supply failure timer. 11. Restoration timer 707 12. Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14. ON/OFF/Control circuit switch with indicator 15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date. 18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring. 708 250 KVA 709 400 KVA 710 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade on cable tray as directed by engineer incharge complete in all respect including The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 711 6 sq. mm 2 core 712 16 sq. mm 4 core 713 25 sq. mm 3-1/2 core 714 70 sq. mm 3-1/2 core 715 95 sq. mm 3-1/2 core 716 150 sq. mm 3-1/2 core 717 240 sq. mm 3-1/2 core 718 300 sq. mm 3-1/2 core 719 SupplyofPower/Control Copper Cables,Solid Copper conductor,XLPE Insulated,cores laid up, PVC tape innersheathed,Unarmoured/Armour (Glavanised wire for cables up to 14x1.5 sqmm, 9x2.5 sqmm,2x16 sqmm, 3x10 sqmm,4x10sqmm balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988 720 10 sq. mm 4 core 721 35 sq. mm 3-1/2 core 722 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring ofthe cable shall be properly connected with the earth as per direction of Engineer-Incharge. 723 6 sq. mm 2 core 724 10 sq. mm 4 core 725 16 sq. mm 4 core 726 25 sq. mm 3.5 core 727 35 sq. mm 3.5 core 728 70 sq. mm 3-1/2 core 729 95 sq. mm 3-1/2 core 730 150 sq. mm 3-1/2 core 731 240 sq. mm 3-1/2 core 732 300 sq. mm 3-1/2 core 733 Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following sizeon cable tray as required. 734 Upto 35 sq. mm (clamped with 1mm thick saddle) 735 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 736 Providing, laying and fixing following dia RCC pipe NP2 class(light duty) in ground complete with RCC collars, jointing withcement mortar 1:2 (1 cement : 2 fine sand) including trenching(75 cm deep) and refilling etc as required. 300mm Dia 737 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required 738 120mm Dia 739 200mm Dia 740 EXTERNAL LIGHT FEEDER PILLAR 741 Supply installing testing & commissioning of out door type IP66 with additional canopy street light feeder pillar (Distribution Panel) compartmentalised design, dust tight & vermin proof made out of 14 gauge M.S. sheet, stove powder coated complete as required with following incomming & outgoing as per detail below. 742 Incoming 743 63 Amp. 10 KA FP MCCB1 No. 744 Suitable digital contractor and timer for down & dusk 745 100 Amp. TPN Alu. Bus bar 746 Outgoing 747 32 Amp. 10KA DP MCB 9 No. 748 40 Amp. 10KA FP MCB 2 No. 749 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade in existing RCC / Hume / metal pipe as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 750 6 sq. mm 2 core 751 16 sq. mm 4 core 752 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring ofthe cable shall be properly connected with the earth as per direction of Engineer-Incharge. 753 6 sq. mm 2 core 754 10 sq. mm 4 core 755 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required 756 120mm Dia 757 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 758 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead oftwo no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect. 759 Supply and laying of 25 mm X 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. 760 Supply and fixing of 1 no. 8SWG GI wire in 15mm dia GI pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. 761 Supply, Installation, Test & Commissioning of 45W LED Decorative Post Top type luminaire with System efficacy of 100 lm/W (4500 lumens), suitable for external poles of dia. 65mm to 75mm. Luminaire shall be made up of pure polyster power coated RAL7021 pressure die cast Aluminium housing with Polycarbonate Fresnel lens of symmetrical or street optics of same make. All external hardwaremust be of SS304 grade. LM 80-08 compliant LEDs of EMC/ceramic package from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 and IK07 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing).The LEDs used should be with CCT of 5700 K, CRI of Minimum 70 and SDCM <5.LEDs must be driven at max 70% of the rated current. MCPCB with Aluminium core and copper thickeness of 35 micron to be used for LED mounting.LED Driver shall be silicone potted, Integrated type, Isolated, Constant Current with range 150-300V AC. Driver Efficiency > 85% & 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 should be there.Similar to wipro make : LP09-501-XXX-57-XX OR equivalent to regent & trilux 762 Supply of 120W SMD LED Floodlight fixture with System efficacy of 110 lm/W (14400 lumens). Luminaire shall be made up of LM6/ADC12 Alloy, non-corrosive, pure polyster power coated die cast Aluminium housing with PC lens. The housing should be completely screwless. Lumianire should be of dimension 282mm x 292mm x 48mm height ± 5mm height and the approximate weight should be within the 2.2Kg ± 0.25Kg. Luminaire should have 60° beam angle for uniform light distribution. All external hardware must be of SS304 grade. LM 80-08 compliant LEDs of EMC/ceramic package of wattage of 1W-2W from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Maximum LENS dome top temperature shall be less than 95°C at 45°C ambient temperature. Luminaire shall be with IP66 and IK07 protection. It should be cabable to operating under ambient temperature range of 0°C to +45°C. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K, CRI of Minimum 70 and SDCM < 5. LEDs must be driven at max 70% of the rated current. MCPCB with Aluminium core and copper thickeness of 35 micron to be used for LED mounting. LED Driver shall be silicone potted, Integrated type, Isolated, Constant Current with range 140-300V AC. Driver Efficiency > 85% & 5 KV internal surge protection with additional 10KV SPD mounted inside the luminaire and firmly fixed to the housing, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. LED Driver must have short circuit, open circuit, Auto cut-off protection for low and high input voltage. Driver must have 440V input voltage protection for 8 hours. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012.Similar to wipro make : LF40-132-060-57-HE or equivalent to regent & trilux 763 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead oftwo no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect. 764 Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost ofG.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in all respect. 765 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 766 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 767 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required. 768 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 769 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 770 100 mm width X 50 mm depth X 1.6 mm thickness 771 300 mm width X 50 mm depth X 1.6 mm thickness 772 450 mm width X 62.5 mm depth X 2 mm thickness 773 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conformington MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, netmetering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286/IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10years and 80% at the end of 25 years 774 .b)Power Conditioning Unit (PCU) of 350-800VDC Input voltage range and 400VAC, three phase, 4wire, 50Hz+/-2.5Hz, out put voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0to50degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for in coming and outgoing cable alongwith glands, lugs and other accessories etc. as required. 775 e) Lightning and surge voltage protection.f)Connections&Interconnectionsbysupplying&fixingrequiredsizeXLPEinsulatedcopperconductor1.1kVgradearmouredpowerandcontrolcablesbetweensolarmodules,mainpowercabletogridsupplyPCUunitalongwithsupplying&fixingofnecessarychannel/conduitlugsandotheraccessoriesetc.asrequired.1kWp 776 PUMP ROOM 777 Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainlesssteel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class- F insulation, conforming to IS-325. supply , Installation, testing and commissioning of fire Hydrant valve , bearing to IS:5290 marks, S.S.,IS: 304 Grade, 63mm oblique instantaneous single out let, 75mm N.B. flanged inlet, brass spindles complete with PVC blank cap . G.I. chain etc. guard,foundation bolts etc.as required. supply , Installation, testing and commissioning of Branch pipe . S.S. short type with 63mm male instantaneous inlet, male threaded outlet fitted with 15mm, Bore nozzle,having IS: 903 with anti vibration pads. 100hp 778 2280 LPM 70 MTR HEAD 779 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 780 2280 LPM 70 MTR HEAD 781 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. M.S.fabricated Common M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plasteredand with anti vibration pads. 782 180 lpm at 70 m Head 783 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump setcomplete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with. 784 INCOMING 785 Incomings 786 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A 787 Outgoings 788 ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) 789 Main Fire Pump 790 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 2 Set 791 Jockey Pump 792 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 2 Set 793 Diesel Engine Control 794 Control for diesel engine comprising - 795 Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manualmode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications. 796 Supply, erection and testing of ISI marked M.S. pipes (class C) and specials etc. (as per IS:1239) for above ground laying for hydrants system includeing transportation of materials upto the worksite, cuttings the pipes to required length, edge preparation, welding, fixing / erection of pipes including specials i.e. bends, tees, reducers, flanges expansion joints wherever required, washers, nuts, bolts etc. in proper position including all supports as per layout. 797 200 mm dia (wall Thickness 6.3 mm) 798 150 mm dia 799 100 mm dia. 800 150 mm dia 801 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required washers etc.as required : 802 200 mm dia 803 100 mm dia 804 150 mm dia 805 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 806 200mm dia. 807 Installing ,testing and commissioning of butterfly valve , PN- 1.0,slim seal,standard lever operated type with required flanges, nuts ,bolts etc. complete. 808 200 mm dia. 809 150 mm dia. 810 100 mm dia. 811 Providing and fixining pressure gauge. 812 Providing and fixining 25 mm dia Ball Valve. 813 Providing and fixining air release valve. 814 Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 815 Supply, installation, testing & commissioning of flow switches with two no and two NC contacts with necessary nipply & other fittings, Flow switch shall be suitable for 150 dia. 816 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 817 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 818 150 mm dia 819 Supplying, Installing, hydraulic testing and commissioning of heavy grade MS Pipe confirming to IS:1239 part-1 with malleable specials confirming to IS:1239 part-II, such as Tee, elbows, check nuts, unions, flanges, nipple etc. Including cutting, fixing in/on wall/ on Floors, ceiling by using usitable supports such as MS channels, angles, flats, rods as required at site with anchor fastners, clamps, threaded rods, nuts, bolts, washers etc.. complete. Painting the exposed with one coadt of metal zinc chromate primer with two coats of synthetic enamal paint of approved colour/shade etc. complete. 820 80 mm dia 821 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 822 80 mm dia 823 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 824 Hose cabinet stand mounted type fabricated out of M.S. sheet of 16 swg. With glass fronted (4mm thick glass with rubber beading) door and size of the cabinet shall be 600x750x250mm Quoted rate shall be inlcludes suitable stand for mounting for ground level with sup[orts all fastners etc, and cabinet shall be painted/powder coated of approved colour both inside and out side. 825 supply , Installation, testing and commissioning of Branch pipe . S.S. short type with 63mm male instantaneous inlet, male threaded outlet fitted with 15mm, Bore nozzle,having IS: 903. 826 supply , Installation, testing and commissioning of Fire Hose,RRL hose jacketed with circular woven synthetic fibre,conforming to IS 636:88 63MM DIA.x 15mt. Long withSS 63mm 2 pair of male and female instantaneous coupling having IS :903 mark and duly S.S. wire wounded. The hose shall be rolled and hug to suitable M.S. support in the fire station. 827 Supplying and fixing of fire brigade connection ofcast iron body with gun metal male instantaneous inletcouplings completewith capand chainas reqd. forsuitable dia MS pipe connection conforming to IS904as required4 Way Fire Brigade Inlet Connection 150mm Dia. 828 Supplying, fixing, testingand commissioning of butterfly valve of PN1.6ratingwithbronze/gun metal seatduly ISImarked complete with nuts, bolts, washers, gasketsconforming to IS 13095 of following sizes as required : 829 80 mm dia 830 150 mm dia 831 Providing, installation, testing and commissioning ofnon-returnvalveof followingsizesconfirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 832 150 mm dia 833 Supply , Installation, testing and commissioning of Fire Hydrant valve , bearing to IS:5290 marks, S.S.,IS: 304 Grade, 63mm oblique instantaneous single out let, 75mm N.B. flanged inlet, brass spindles complete with PVC blank cap . G.I. chain etc. 834 supply , Installation, testing and commissioning of Branch pipe . S.S. short type with 63mm male instantaneous inlet, male threaded outlet fitted with 15mm, Bore nozzle,having IS: 903 835 supply , Installation, testing and commissioning of Fire Hose,RRL hose jacketed with circular woven synthetic fibre,conforming to IS 636:88 63MM DIA.x 15mt. Long withSS 63mm 2 pair of male and female instantaneous coupling having IS :903 mark and duly S.S. wire wounded. The hose shall be rolled and hug to suitable M.S. support in the fire station. 836 supply , Installation, testing and commissioning of manual swing type Fire hose reel IS:884 comp. with heavy duty reel, 19mm dia. X30 mtr. Long 2- ply polyster yarn braided / rubber braided pressure hose with heavy duty nylon on/off jet/ spray nozzle, 25mm isolating valve and all other necessory. 837 Supply and fixing of Fire Shaft door fabricated out of G.I. Sheet and frame, door shall be 900mm x 1500mm min with double leaf. & fixed with 4 mm thick Glass, suitable Rubber beeding and Locking arrangment. Quoted rate shall be included alll fasterners etc, and complete shutter shall be powder coated of approved colour both inside and out side. 838 Providing/Fixing Fire man axe. Make. 839 CO2 type Fire exitinguisher ISI marked confirming to IS:15683 lates. Capacity 4.5 kg complete with delivery hose horn, squeeze grip release valve, locking arrangement, operating temperature -30°c to +55°c, supplied with body bearing IS 7285 mark and approved valve as per IS 3224. Co2 Gas as per IS:15222. externally painted with PO Red Shade No. 538 of IS 5, operation manual and floor stand or wall mount Bracket including accessories as required as per site condition. 840 4.5 kg. 841 Powder Fire exitinguisher (stored Pressure Type) (Powder pressurized with dry nitrogen gas at 15 bar) capacity 4kg duly ISI marked conforming to IS:15683:2006/latest, with IS 14609 ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangment, pressure gauge, operation maual, Body Hydrotested at 35 bar, operating temperature--30°c to +55°c, external epoxy powder coating with PO Red shade No. 538 of IS 5, and floor stand or wall mount Bracket including accessories as required as per site condition. 842 4.5 kg 843 Supplying, Installing, hydraulic testing and commissioning of heavy grade MS Pipe confirming to IS:1239 part-1 with malleable specials confirming to IS:1239 part-II, such as Tee, elbows, check nuts, unions, flanges, nipple etc. Including cutting, fixing in/on wall/ on Floors, ceiling by using usitable supports such as MS channels, angles, flats, rods as required at site with anchor fastners, clamps, threaded rods, nuts, bolts, washers etc.. complete. Painting the exposed with one coadt of metal zinc chromate primer with two coats of synthetic enamal paint of approved colour/shade etc. complete. 844 25 mm dia 845 32 mm dia 846 40 mm dia 847 50 mm dia 848 Supply testing and commissioning of 15mm gunmetal/chrome quartzoid bulb, standard reponse sprinkler heads suitable for 65 deg. C K-80. 849 Pendent-68 deg C. 850 Horizontal side wall sprinkler 851 Dial Type pressure guage for (0-16 kg/cm2) with necessary nipple & other fittings, mounting arrangements and with 15 mm ball valve. 852 Supply, Installtion, Testing & commissioning of 25mm ball valve with sight glass for sprinkler test line. 853 Supply, Installation, testing & commissioning of 50mm ball valve for sprinler drain line. 854 Supply, installation, testing & commissioning of flow switches with two no and two NC contacts with necessary nipply & other fittings, Flow switch shall be suitable for 100 dia. 855 Supply, Installtion, testing and commissioning of 25 mm diameter Forged Brass air release valve PN-1.6 Body. 856 Supply, Installation and commissioning of Annunciator Panel with 7 windows with point, zone & system status used with RS 485. 857 Supply, Installation wire for annunciator panel. 858 3 core 1.5 sq mm.