}

Tender For Repair/ Replacement Of Light Fitting With Connected Items Of Tarmac, Sun Shelters And Bps Under Ge (Af) Jamnagar No 1, jamnagar-Gujarat

Tender Notice

52090691
Tender For Repair/ Replacement Of Light Fitting With Connected Items Of Tarmac, Sun Shelters And Bps Under Ge (Af) Jamnagar No 1
Tender
Indian
Gujarat
Jamnagar
21-11-2025

Tender Details

Tender For Repair/ Replacement Of Light Fitting With Connected Items Of Tarmac, Sun Shelters And Bps Under Ge (Af) Jamnagar No 1; 1 Taking down carefully aluminum/copper flame proof point wiring complete of any type (surface ERW conduit for light point, fan point, or power point complete with all fitting such as rotary switches, sockets, fan regulators etc complete and making good disturbed surfaces complete all as specified as directed by Engineer in Charge. 2 Taking down carefully flame proof/flood light/high bay light fittings of any description from existing position from Hanger/tarmac/BPs complete all as specified as directed by Engineer in Charge. 3 Taking down old sub main wiring including rigid steel conduit with all accessories and removing to and making good disturbed surfaces complete all as specified as directed by Engineer in Charge. 4 Material & Labour for point wiring for one light point controlled by one flameproof switch, complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen) cable 1100 volts grade ISI marked drawn and including mild steel ERW conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc.including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH cable as a earth wire connected to common earth dolly, etc complete all as specified as directed by Engineer in Charge. 5 All as per item No 04 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke & Halogen, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch complete all as specified as directed by Engineer in Charge. 6 Material & Labour in repair for sub main wiring with 2 run single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete.Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment complete all as specified as directed by Engineer in Charge. 7 Material & Labour in repairfor sub main wiring with 2 run single core multistranded copper conductor cable of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class B (ISI Makes) not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified as directed by Engineer in Charge. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. 8 Material & Labour in repairfor sub main wiring with 2 run single core multistranded copper conductor cable of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class B (ISI Makes) not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified as directed by Engineer in Charge. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. 9 Material & Labour in repairfor sub main wiring with 4 run single core multistranded copper conductor cable of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class B (ISI Makes) not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified as directed by Engineer in Charge. Note: 4 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. 10 Supply and fix in repairs flame proofand weather proof industrial type DBs with and including various combination of incoming and outgoing flame proof MCBs suitable for and including (a) 01 No MCB TPN 63 Amps, C type (incoming) (b)06 Nos MCB SP 10 Amps C type (c) 2 Nos MCB SP 20 Amps C type, including necessary connection, complete all as specified as directed by Engineer in Charge. 11 S&F in replacement ofLED flood Light fitting 200 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete all as specified as directed by Engineer in Charge.Make:-cat no. JETAVALOURFL200WLED757MODNBLTG of Havells OR equivalent of crompton/philips/wipro/syska/C&S electric/HPL electric & power Ltd/HELONIX TECHNOLIES. 12 S&F in replacement ofLED flood Light fitting 240 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete all as specified as directed by Engineer in Charge.Make:-cat no.JETAVALOURFL240WLED757MODWBLTG of Havells OR equivalent of crompton/philips/wipro/syska/C&S electric/HPL electric & power Ltd/HELONIX TECHNOLIES.. 13 S&F in replacement ofLED flood Light fitting 120 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete all as specified as directed by Engineer in Charge.Make:- cat no. JETAIRISFLS120WLED757SYMLTG of Havells OR equivalent of crompton/philips/wipro/syska/C&S electric/HPL electric & power Ltd/HELONIX TECHNOLIES. 14 S&F in replacement Flame proof weather proof LED Flood light of capacity 100 wattepoxy finish withLM 6 aluminiumhousing , heat resistant borosilicate tubular glass held in two alluminium cups with inbuilt DRIVER accessoriescomplete all as specified as directed by Engineer in Charge.Make: Sudhiror equivalent in CROMPTON/Bajaj 15 Supply and fix in repair weather proof and flame proof PVC knob suitable for flame proof DBs/switch of any size and capacity as per site requirement complete all as specified as directed by Engineer in Charge. 16 Supply and fixing in repair PVC copper condutor 2.5 sqmm 4 core complete all as specified as directed by Engineer in Charge. 17 M&L for taking outMotor & pump of 7.5 KW/ 10 HP cap , Dismantling the motor with disconnecting the same from the compressor and remove rubber coupling and its connected accessories and transporting to reputed work shop for rewinding . opening themotor, cutting & removing old and burnt windingwire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate,reassembling, refixing in same position & connecting including testing and commissioning complete all as specified as directed by Engineer in Charge. 18 Supply and fixing pully to motor chain (MS) suitable for 10 HP Motor complete all as specified as directed by Engineer in Charge. 19 Supply and fixing limit switch suitable for motorised shutter having 10 HP motor complete all as specified and as directed by Engr-in-charge. Note Cost of welding, proper allingment of limit switch are deemed to be inlcuded in the qutoed rate complete all as specified as directed by Engineer in Charge. 20 Supply and fixing SWR 6mm dia complete all as specified as directed by Engineer in Charge. 21 Supply and fixing cable carrier with clamp complete all as specified as directed by Engineer in Charge. 22 Supply and fixing PVC Sheathed copper cable 0.5 sqmm 7 core complete all as specified as directed by Engineer in Charge. 23 Supply and fxing control panel suitable for Motorised shutter having 10 HP Motor complete with following accessoriescomplete all as specified as directed by Engineer in Charge.(a) 3/4 pole power contactor 45 A, 415 V, coil voltage 230 V with including 1 NO & 1 NC contact connecting complete 02 Nos (b) Selector switch of suitable capacity, Push Button to operator shutter(c) MCB TPN 02 Nos 63 Amp (d)MCCB 63 Amp as Incomer , relay, RYB indicator, Push Buttons or any other parts required for operation of Motoriszed shuttercomplete 24 S&F in replacement of Sheet moulding compound (SMC) junction box of size 350 mm x 200 mm x 150mm, comprising three phase aluminium bus bar and one No MCB SP, 06 Amps C type, fixed on pole with mild steel clamps, nuts and bolts complete all as specified as directed by Engineer in Charge.Make:-Sintex/Legrand/Siemens/EPP composite Pvt Ltd. 25 Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 10 sqmm 2 /4 coreincluding cable cover complete all as specified as directed by Engineer in Charge. 26 Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 16 sqmm 4coreincluding cable cover complete all as specified as directed by Engineer in Charge. 27 Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 25 sqmm 3.5coreincluding cable cover complete all as specified as directed by Engineer in Charge. 28 Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steelstrip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified as directed by Engineer in Charge. 29 Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steelstrip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified as directed by Engineer in Charge. 30 Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steelstrip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified as directed by Engineer in Charge. 31 Note for ser No 28 to 30. XLPE cable to be fixed on wall/trusses/roof with the help of steel clamp/Tie of suitable size. Cost of the same are deemed to be inlcuided in the quoted rate complete all as specified as directed by Engineer in Charge. 32 S&F in repair PVC insulated, 2 core 2.5 Sqmm round sheathedcopper conductor(flexible) industrial cablefire retardant complete all as specified as directed by Engineer in Charge. 33 S&F in repair PVC insulated, 2 core 10 Sqmm round sheathedcopper conductor(flexible) industrial cablefire retardant complete all as specified as directed by Engineer in Charge. 34 S&F in replacement Tubes 40 mm bore, light grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified as directed by Engineer in Charge. 35 S&F in replacement Tubes 50 mm bore, light grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified as directed by Engineer in Charge. 36 Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC Casing capping of suitable size, including all accessories like bend, tees, junction boxes etc.including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including PVC terminal box of suitable sizecomplete all as specified as directed by Engineer in Charge. 37 All as per item No 36 above but point wiring for one 5 Amps socket outlet on independent board controlled by one-way switch complete all as specified as directed by Engineer in Charge. 38 All as per item No 36 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch complete all as specified as directed by Engineer in Charge. 39 All as per item No 4 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch complete all as specified as directed by Engineer in Charge. 40 S&F inSwitch piano, flush type single pole, one way 5 Amp including connection complete all as specified as directed by Engineer in Charge. 41 Supply & Fixing Socket outlet 3 pin, 6A, flush type including connection complete all as specified as directed by Engineer in Charge. 42 S&Fswitch flush type 16 Amps,including connection complete all as specified as directed by Engineer in Charge. 43 S&F socketflush type 6/16 Amps, 2 in 1 multipurpose including connection complete all as specified as directed by Engineer in Charge. 44 M & L in repair for Ceiling rose 3 pin flush type 6 Amps, 240 volts AC ISI marked complete all as specified as directed by Engineer in Charge. 45 Supply and fixingMCCB triple pole and neutral , DPX3 thermal magnetic capacity of 100 Amps,415 V and 16KA Short Circuit Breaking Capacity complete all as specified as directed by Engineer in Charge. 46 Supply and fix MCB’ssingle pole, 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connectingall as specified as directed by Engineer in Charge. 47 Supply and fix MCB’ssingle pole & neutral, 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connectingall as specified as directed by Engineer in Charge. 48 Supply and fix MCB’ssingle pole & neutral, 40 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connectingall as specified as directed by Engineer in Charge. 49 Supply and fix MCB’striple pole and neutral, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connectingall as specified as directed by Engineer in Charge. 50 Supply and fix MCB’striple pole, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connectingall as specified as directed by Engineer in Charge. 51 Supply and fix in repair of Single pole and neutral enclosure with a two pin and earthplug and socket complete with one double pole MCB 20ampc curve complete all as specified as directed by Engineer in Charge. 52 Supply and fix in repair of Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 amp C Curve complete all as specified as directed by Engineer in Charge.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 30 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail