Tender For Work Services For Installation Of Static Aircraft Arresting Gears (Aags) At Af Stn Bareilly; 1 Surface Excavation(manual excavation), n exc 30cm deep and averaging 15 cmdeep and getting out in soft & loose soil complete all as specified and directed. 2 All as per Item No. 1 above but Add or deductfor every 3 cm (or part thereof) above 15 cm average depth, complete all as specified and directed. 3 Excavating over areas (manual excavation), n exc 1.5 m deep and getting out earth in soft & loose soil complete all as specified and directed. 4 Excavating in trenches (manual excavation), n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft and loose soil for depth for laying cables or foundation of electric pole / Stay assembly and getting out in soft / loose soil including trimming sides and forming bottom surface to the required level / slope etc complete all as specified and directed. 5 Spreading and levelling of earth and well ramming in layers n.exc 25 cm including watering and compaction of surplus soil obtained from item No. 1 to 4 above complete all as specified and directed. 6 Returning, filling in, including spreading, levelling, watering and well ramming, in layers not exc 25 cm in soil complete all as specified and directed 7 M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete etc. complete all as specified and directed. 8 M&L for Formwork (rough/fair finished) to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. 9 M&L for RCC M-35 Design mix (20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 10 M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. 11 All as per item No 10 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and complete all as specified and directed. 12 M&L for cement concrete cast-in-situ type B1 1:2:4 (using 20 mm graded crushed stone aggregate) as in bedding to pipes,lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. 13 M&L for loose filling with bajri/ gravel 5 to 10mm size in layers n exc 15cm thick each layer spread, levelled and rammed including watering complete all as specified and directed. (Compacted thickness will only be measured and paid). 14 S&F for Mild steel bolts of dia of neck exc 12mm but n exc 20mm,purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long and including provision of temporary templates made out of mild steel plates minimum 3 mm thick complete all as specified and directed. 15 S&F for mild steel tubes as in sleeves for foundation bolts, cut to required length including bends etc. ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St- 240 complete all as specified and directed. 16 M&L for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (wind tie beam, Beam, tee, angle, channel, plates or flat sections, bolts) including distance pieces, cleats etc conforming to Fe-410 W (Gde-E- 250) quality- A, complete all as specified and directed. 17 M&L for Preparation of new steel surfaces of any description, exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 18 S&F 1.60 mm thick corrugated mild steel,black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. 19 Removing the debris/ spoil to a distance not exceeding 50 m and deposited at a level n.exc 1.5 m above the starting point of surplus soil obtained fromitem 1 to 4 , complete all as specified and directed. 20 M&L for preparation of new Concrete surfaces and applying twocoats of water based paint over a coat of primer in specified pattern and colour complete all as specified and as directed. Note : Colour scheme and design shall be as per users requirement and direction of Engr-In-Charge/GE. 21 S&F for mild steel works in bands, straps, supports or stays including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; handmade sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers including temporary templates for installation of anchor bolts in foundation and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. 22 S&F for wire netting of galvanised steel wire 1.40 mm dia, size of mesh 20 mm fixed with tinned tacks of wire staples complete all as specified and directed. 23 M&L for providing heavy duty cranewith operator and helperof capacity ( 6 to 10 Ton) for installation of BAK-12 and Roller edge sieve assembly at site by using spacer bars and all related accessories of Crane and required manpower for manning etc (21 days at site) complete all as specified and directed. 24 M&L for 450 mm Nominal bore PVC pipe having an actual pipe OD of 458 mm, pressure rating 130 Psi, all as per IS-4985 (2000) jointed with PVC solvent cement and fixed on RCC pillars as per drg (RCC shall be paid separately) complete all as specified and directed. 25 M&L 150 mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate)in sub base of floor complete all as specified and directed. 26 M&L for M-25 design mix (using 20 mm graded crushed stone aggregate) in foundations,including rafts, footings, foundation beams; plinth beams, bases for columns,etc;basement slabs,under-reamed piles and mass concrete as in Tape sweep area finished even and smooth complete all as specified and directed. 27 M&L reinforced concrete 300mmborepipes, class NP2, laid and jointed complete with collars including cement concrete 1:3:6 type C-2bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed. 28 Demolition of unreinforced cement concrete (Hard standing) in ground floors and pavings of any description and in any position complete all as specified and directed. 29 Removing the debris/ spoil to a distance exceeding 15.00 Km outside the defence land complete all as specified and directed. 30 M&Lfor applying grouting cement (SIKA 212-214 or equal)complete all as specified and directed. 31 M&Lfor preparing of old/new surface of road and applying one coat of retro reflective thermoplasticpaint complete all as specified and directed. 32 Excavating over areas (manual excavation),exc 1.5 m deep and getting out in soft & loose soil complete all as specified and directed. 33 M&L 01 Nitrogen Cylinder of weighing 47kg Required during installation of equipment, all as specified and directed by Engr-in charge. 34 M&L 04 Nos of ground clamp to hold ground rod and THT steel required for each system as per requirement by OEM, all as directed 35 M&L 75 mm width and 65 m length cello tape required to be fixed below PVC sleeve for concrete leakage and also to save the threads of the bolts, all as specified and directed by Engr-In-Charge. 36 M&L for Forming embankment with cement stablized soil including spreading and levelling watering ramming, pulverising blending of cement with soil stablization by mixing with 5% cement by weight through mechanical operation and rolling and consolidating the surface (500mm thick compacted stablized layer) and rolled with 8 to 10 Tonne power rollerto achieve 98% modified proctor density and minimum soaked value 4Kg/Sqm with 75 cm dia plate complete all as specified and directed. Approved earth obtained from here in before of this BOQ shall be used.Note:- (i) The cement will be paid separately.(ii) Percentage of cement 5% given tentative and shall be decided based on approved design mix. However no extra payment for labour for maintaining in cement quantity beyond 5% plus or minus shall be made. 37 Supplying portland pozzolona cement complete all as specified and directed. 38 M&Lfor applying two coats of waterproof paint over a coat of primer for surface painting of foundation in contact with soil complete all as specified and directed. 39 Rolling and consolidating formation surfaces in cutting & on hard core surfaces with 8 to 10 ton power roller complete all as specified and directed. 40 M&L for Hardcore of broken stone or boulders of guage exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 150 mm thick each layer, watered and rolled with 8 to 12 ton power roller to a true surface to required gradient and camber as required complete all as specified and directed. 41 M&L 250 mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregatein sub base of floor complete all as specified and directed. 42 M&L for 200 mm thick (compacted thickness) PCC , M-25 design mix (using 20mm graded crushed stone aggregate) casted in panels as in pavement of road including all necessary formwork complete all as specified & directed. 43 M&L for Finishing the surface concrete by brooming while the concrete is still green complete all as specified and directed. 44 M&L for Forming Construction joint 10mm wide and 30mm deep by cutting with diamond cutter and filling with sealing compound Grade A complete all as specified and directed. 45 M&L for forming Contraction(Dummy) joint 65mm deep x10mm wide by cutting with diamond cutter and filled by sealing compound grade A complete all as specified and directed. 46 M&L 100 mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregatein sub base of floor complete all as specified and directed. 47 M&L for 100 mm thick (compacted thickness) PCC 1:2:4type B-1 (using 20 mm graded crushed stone aggregate) as in paving complete all as specified and directed. 48 M&L for forming 20 mm wide expansion joint , filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound grade A for 250 mm thick concrete slab and complete all as specified and directed. 49 Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 4 core complete all as specified and directed. 50 M&L for Dry sand cushioning for protection of underground cables (8cm before laying the cable and 15cm after laying the cable in trenches) complete all as specified and directed. 51 M&L for Well burnt Sub class B, modular bricks laid dry, flat, over the cable abutting each other, length of brick equal to width of brick, complete all as specified and directed. 52 S&F flush mounting factory madeSPN DBs Double door or equivalent, IP-43 Protection, IK-09 with metal door, with neutral bar, Earth bar andcables ties for cable management fully insulated bus bar 8 way with 100 Amps rated bus bar complete all as specified and directed. Make:- Ekinoxe of Legrand or in Scheider and siemens. 53 S &F MCB Triple pole and neutral 415 volts 32 Amps breaking capacity10KA C series etc completed all specified and directed 54 S&F MCB SPN (single pole and neutral), 240 volts,40 Amps breaking capacity 10 KA, ‘C’ Series. etc, complete all as specified and directed. 55 S & F MCB single pole 240 volts, B curve of rating from 6 to 32 amps, with rupturing capacity 10 KA,including providing thimble for outgoing cables complete all as specified and directed. 56 M&L for sub main wiring concealed complete with two runs of 1100 Volts grade 4.0 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade drawn through and including 25mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. with one run of 1100 Volts grade 4.0 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as earth continuity conductor, including taking down all as specified and directed. 57 M&L for Point Wiring for one light point controlled by one way switch completewith 1.5 Sqmm FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts grade drawnin and including concealed non-metallic rigid PVC conduit medium grade with all fittings (ISI Marked) not less than 20 mm external dia but shall be increased as per actual site requirement in accordance with clause no 19.125 of SSR part Ifixed concealed / recessedin wall / ceiling etc including1.5 Sqmm FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts grade as earth continuity wire including MS sunken pressed steel terminal boxes of suitablesize, made of sheet 1.6mm thick with 3.0 mm thick bakelite sheet top cover for complete all as specified and directed. 58 Supply & Fixing of LED flood light 100W 230volt AC outdoor type with thermal management in multiple optics equipped with IP66 protection with pact and corrosion resist complete with driver and lamp complete all as specified and directed. 59 M&L for point wiring with 2.5 sqmm single core 1100V grade FRLSH PVC insulated unsheathed multistranded copper conductor with in and including PVC concealed conduit medium grade with all fittings including pressed MS sheet (1.0mm thick) sunken box with 3mm laminated bakellite sheet cover ISI marked suitable for an independant 6 pin 15/16 amps socket outlet ,including 2.5 sqmm single core 1100v grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyincluding cutting chases in walls / floors for concealed conduiting and making good disturbed surface areato match with the adjoining surface all as specified and directed. 60 S&F socket outlet 2 in 1, 6 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed. 61 S&F switch piano flush type one way 16 amps SP 240 volts complete all as specified and directed. 62 M & L forchemical earthing with copper grounding earth rod of length not less than 3.00 meter,dia 17.23 mm molecularly grounded with250 micron copper ,burried directly in ground,earth not less than 3.20 meters below normal ground level and size of pit hole shall be of 125 mm dia,with top edge of earth rod not less than 0.75 meters below normal ground level earth rod surrounded by at least 30 kg of ground enhancing material i.e 25 kg of Earthcon and 5 kg of Tarrac compound to reduce soil resistivity ,up to 2.80 meters height and including connected to copper strip 32 x 6 mm (upto 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 40mm bore light grade pipe from electrode and upto and including the earth test point of galvanised iron / steel of size 75 x 75 x 25 mm test point, 15 mm bore watering pipe light grade GI funnel, wire mesh,excavation, removal surplussoil to a distance not exc. 50 m, PCC pit inPCC(1:3:6) type C-1, using 20 mm graded stone aggregate, RCC cover 40 mm thick in RCC (1:2:4) type B-1, using 20 mm graded stone aggregate reinforced with 8 mm dia mild steel deformed bars @ 75 mm centre to centre both ways complete all as specified and directed. NOTE:- Additional Chemical compound if required on account to achieve earth resistance less than 1.00 ohm shall deemed to be included in the unit rate of this item. On testing after completion of job, if desired earth resistance (i.e. less than one ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt. 63 S & F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 10 sqmm single corecopper wire including Nuts, volts,washer and lugs complete all as specified and directed.