|
| 1 | DISMANTLING |
| 2 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per MoRTH Specification Clause 202. By Mechanical Means Reinforced Cement Concrete |
| 3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per MoRTH Specification Clause 202. Rubble Stone Masonry in Cement Mortar |
| 4 | SLAB CULVERT |
| 5 | Earth work in excavation for foundation of structurecompletewith all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layers, ramming, watering and disposal of surplus earth with all lifts and lead upto 1000 meters exclusive of compensation of earth as per MoRTH specification Clause 301 to 305. In ordinary soil Depth upto 3 metre |
| 6 | Earth work in excavation for foundation of structurecompletewith all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layers, ramming, watering and disposal of surplus earth with all lifts and lead upto 1000 meters exclusive of compensation of earth as per MoRTH specification Clause 301 to 305. In ordinary soil Depth upto 3 metre & upto 6 metre |
| 7 | Providing and laying Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification as per MoRTH Specification : Section 1500, 1700 & 2100 including form work at any level. P.C.C. grade M15 |
| 8 | Back filling behind abutment, wing wall and return wall in 150mm layers, with mechanical compaction, complete with all lead and lift as per drawing and technical specification as per MoRTH Specification : Clause : 304 Gravelly material |
| 9 | Providing and laying Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification as per MoRTH Specification : Section 1500, 1700 & 2100 including form work at any level. R.C.C. grade M20 |
| 10 | Providing and laying steel reinforcement at any level in foundation/ pile/ pile cap complete as per drawing and clause 1600 of MoRT&H Specification including all material, labour and machinery. \"The structural steel to be used should be Primary Steel manufactured and approved by Engineering in charged \"TMT Steel reinforcement |
| 11 | Structural Cement concrete for plain concrete/ reinforced concrete forsubstructure at any level, complete as per drawing and technical specification. Using Batching Plant, Transit Mixture, and Concrete Pump. Design mix concrete - [MoRTH Specification : Clause 1500&1700] R.C.Cincluding formwork R.C.C. grade M25 upto 5 metre height |
| 12 | Structural Cement concrete for plain concrete/ reinforced concrete forsubstructure at any level, complete as per drawing and technical specification. Using Batching Plant, Transit Mixture, and Concrete Pump. Design mix concrete - [MoRTH Specification : Clause 1500&1700] R.C.C.grade M30 above 5 metre & upto 10 metre height |
| 13 | Supplying, fitting and placing TMT bar reinforcement in sub structure/ superstructure at all level complete as per drawing and clause 1600 & 2200 of MoRT&H Specification including all material, labour, machinary etc. \"The structural steel to be used should be Primary Steel manufactured and approved by Engineering in charged \"TMT Steel reinforcement |
| 14 | Providing A.C pipe Weep holes 150mm dia in Masonry/Plain Concrete/.Reinforced Concrete abutment, wing wall/return wall complete as per drawing and technical specfication as per MoRTH Specification Clause 2205 |
| 15 | Structural Cement concretefor reinforced concrete in superstructure at any level complete including steel formwork, scaffolding etc. as per drawing and technical specification as perDesign mix MoRTH Specification 1500 & 1700. M-30 grade Solid slab superstructure |
| 16 | Providing and laying Steel reinforcement at any level in foundation complete as per drawing and technical Specification as per MoRTH Specification : Section: 1600 \"The structural steel to be used should be Primary Steel manufactured and approved by Engineering in charged TMT Steel reinforcement |
| 17 | Reinforced cement concrete wearing coat M30 grade at any level including formwork and reinforcement complete as per drawing and technical specification as per MoRTH Specification 2202, 1500 &1700 |
| 18 | Provision of reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-20 grade concrete with HYSD reinforcement conforming to IRC: 21 and dowel bars 25 mm dia , 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MoRTH Circular No. RW/ NH- 33022/ 1/ 94-DO III dated 24th June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer , all as specified as per MoRTH specification Cl. 811.2. |
| 19 | Providing and laying Expansion Joint complete as per drawing and technical specification With corrugated copper plate, compressible fibre board, pre-moulded joint filter and joint sealing compound as per MoRTH Specfication section 2600 Providing and fixing 20mm thick compressible fibre board in expansion joint complete. |
| 20 | Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and MoRTH Specification Clause 801 |
| 21 | Providing and laying Expansion Joint complete as per drawing and technical specification With corrugated copper plate, compressible fibre board, pre-moulded joint filter and joint sealing compound as per MoRTH Specfication section 2600 Providing and filling joint sealing compound -Coarse sand with bitumen (6% by weight) |
| 22 | Providing boulders/stone backing 600 mm thick behind abutment/wing/return wall. Retaining wall/breast wall of bridges with stone not less than 15 KG (expect smaller stones to be used for filling up the voids) with all leads lifts ascents descents handling. crossing of nallahas, streams and all other obstructions all labour and materials as a complete job, as per railway specifications and as directed by the Engineer in charge. note - payment to be made on stack measured quantity of boulders/stones redacted by 15% to allow for looseness in stacking. |
| 23 | Drainage spouts complete as per drawing and MoRTH specifications Clause 2705 |
| 24 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 2905. 1200mm |
| 25 | Providing concrete for plain/reinforced concrete in open foundations completeasperdrawingsandMoRTHspecificationsClause1702,1703, 2102 & 2104 P.C.C grade M 10 Nominal mix 1:3:6 |
| 26 | Cement Concrete PavementConstruction ofun-reinforced , plain cement concrete pavement M30 (Grade), thickness as per design, over a prepared sub base, with 43/53 grade cementas per Clause 602, coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 31.5 mm, mixed in a in fullyautomatic Batching Plant andtransported to site intransit mixer for having continuous agitated mixer, manufactured as per approved mix designincluding pumping of R.M.C. from transit mixer to site of laying , with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge laid with a Fixed Form Paver (laying and fixing of 125 micron thick polythene Film and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days using water finishing to lines and grade as per drawingand MoRTH Specification Clause 602 including vaccum dewatering process with all required equipments (Dowel Bars will be paid seprately).ewatering process with all required equipments. |
| 27 | ROAD FURNITURE |
| 28 | Supply of Hazard Marker made out of 2 mm thick M.S. sheet size 300x300x3 mm framed with angle iron 25x25x3 mm and fixed on channel posts 75x40x6 mm and hold fast at bottom whole body is painted in white stoving enamel and 6 Nos., 5 cm dia reflective sheet on white reflective background with additional border of 1.25 cm all arount it. |
| 29 | Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 801.3.1 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and MoRTH Specification Clause 801 600 mm x 450 mm rectangular |
| 30 | Supply& Fixing of flood gauge (water Gauge) as per I.R.C. 67 standard 200 cm long fixed on angle iron posts 50x50x6 mm, 2.6 M. long. |
| 31 | RETAINING WALL |
| 32 | Earthwork in excavation for structures as per drawing and MoRTH specifications Clause 304.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil Upto 3 m depth |
| 33 | Providing concrete for plain/reinforced concrete in open foundations completeasperdrawingsandMoRTHspecificationsClause1702,1703, 2102 & 2104 P.C.C grade M 10 Nominal mix 1:3:6 |
| 34 | Providing concrete for plain/reinforced concrete in open foundations completeasperdrawingsandMoRTHspecificationsClause1702,1703, 2102 & 2104 P.C.C grade M 15 Nominal mix (1:2:4) |
| 35 | Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and MoRTH Specification Clause 807 |
| 36 | Providing and laying steel reinforcement at any level in foundation/ pile/ pile cap complete as per drawing and clause 1600 of MoRT&H Specification including all material, labour and machinery. \"The structural steel to be used should be Primary Steel manufactured and approved by Engineering in charged \"TMT Steel reinforcement |
| 37 | Painting two coats with superior grade synthetic enamel paint of approved quality to give an even shade including writing lettering and figures with synthetic enamel paint as per IRC specifications. Guide Stone, Guard Stone, Tree Guards and Posts |
| 38 | Providing A.C pipe Weep holes 150mm dia in Masonry/Plain Concrete/.Reinforced Concrete abutment, wing wall/return wall complete as per drawing and technical specfication as per MoRTH Specification Clause 2205 |