| 1 | Supplying, installing, testing and commissioning of 5 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (550 Wp X 11 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.c. ACDB/ DCDB, MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG |
| 2 | Additional MSEDCL Charges for Net Metering System atproposed for PWS Scheme including Solar Net Meter, Panel Cables, Earthing etc complete |
| 3 | Supply and commissioning of IOT based self powered water tank level controller and monitoring with five year CMC |
| 4 | Design supply and commissioning of hybrid controller for 3 to 100 Hp solar pumping system compatible to cloud based (RMS) dashboard reporting/ monitoring and management system with five year CMC |
| 5 | Design supply and commissioning of IOT/Commander as per specification compatible to item no. 6 |
| 6 | Providing,installing testing and commissioning of in line batteryoperated ultrasonic bulk type water meters ISO 4064 with built in data logger and GSM/GPRS modem for transfer of data communication to remote central computer as per working on following conditions and specifications.The meter shall be suitable for 50oC and provided with IP 68 protection class with complete immersion of water.The meter shall have battery life of min.10 years should be able to detect the reverse flow volume and tampering. The accuracy of the meter shall be +/- 1 % of measured value including 36 months guarantee etc complete.( With Simcard and its charges,valid for 36 months) |
| 7 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking andspreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259)Lift 0 to 1.5M |
| 8 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the areaand lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) Lift 0 to 1.5M |
| 9 | Providing and laying in situ Cement Concrete M-15 of trap/granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) M-150 |
| 10 | Providing and laying in situ Cement Concrete of trap/granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing andcuring, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 11 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. |
| 12 | Providing and casting in situ Cement Concrete of trap/granite/quartcile gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer in charge including normal dewatering centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided ded and curing, etc. complete. (By weigh balching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birta Gold. Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 13 | Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire), (Bd-F- 17/306) |
| 14 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates, etc. as per detailed design and drawing or as directed by Engineer- in charge including cutting, fabricating, hoisting, erecting and fixing in position, making riveted/bolted/welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete.(Bd-C-8/278) |
| 15 | For structureProviding and applying material & labour for hot dip galv anizing of above structure including transport for galvanizing as per R.C |
| 16 | Supplying and installation of Solar PV Module cleaning unit consisting ofnozzles spray, necessary pipes, valves, post, electronic panel board concealed with weather proof cabinet, spreading water periodically for removal of dust, related motor pump, controller, timer and nozzles set suitable for covering 5 KW Solar PV Module. (Approx. 35 Sq. Mtr. PV Module area). For 5 Kwp 22541+3200+ 5%= 27028.05 |
| 17 | Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge |
| 18 | Miscellaneous Charges ( site cleaning charges, piping for panel cleaning , water sprinklers, and required motor , wire, switch,additional required accesories, etc complete.) |