Tender For Balance Electrical Works At Business Facilitaion Center (Bfc) Building, Raigad-Maharashtra

Tender Notice

52067308
Tender For Balance Electrical Works At Business Facilitaion Center (Bfc) Building
Tender
Indian
Maharashtra
Raigad
05-11-2025

Tender Details

Tender For Balance Electrical Works At Business Facilitaion Center (Bfc) Building; 1 Supplying and erecting checker plate of iron sheet metal work consisting of MS sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the site engineer. to HT Room, LT oom, Battery Room and Transformer Room. 5mm thick grating plate, sturdy grill shall be done ( Grill design to be discuss & finalized mutually ) Total area 900 sq.ft. = 1) MS Checker Plate 4 MM. Wt 3.10/sq.ft 2)Angle 75 x 75 x 5 MM 1.1 TR Room 1.2 LT Room 1.3 Battery Room 1.4 HT Room 1.5 Other Miscelleneous Area 2 LED Flood light. Supplying and erecting integrated LED flood light fitting Min. 100W IP65 & IK08 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FG- ODF/FL. for Outdoor including Supporting Arm, Wiring and Civil Works - Substation Outside Area Nos 8 3 Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways/24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB. 3.1 LT Room 3.2 HT Room 4 Point wiring for light/fan/ Exhaust Fan Point wiring for light/fan/ Exhaust Fan/Bell concealed type with 2x 1.5 sq. mm copper PVC insulated FRLS grade (Fire Retardant Low smoke) wire and 1.5 sq. mm PVC insulated green colour wire for earthing, 1.1 kV grade ISI marked with appropriate colour coding and with limitation to no. of wires with respect to pipe size duly drawing in rigid PVC conduit (HMS) minimum 20 mm dia. ISI marked with necessary accessories viz. Deep junction boxes, inspection boxes, bends etc. making complete piping rigid by adhesive/resin and fixed with binding wire, U nails, all duly concealed in ceiling, RCC slab, beam while casting and in walls by making chases; finished with cement morter to match background complete and terminating the wires with pin type lugs in ceiling rose/lamp holder/connector/batten holder/angle holder erected on hylam plate on box and modular type 10-A switch erected on original sheet metal box/ non-metallic un breakable box flush on wall with double (mounting & cover) plate, Anchor/Roma make modularSwitches and Required Accessaries. Sr. No. 5+6+7+8 = 105. Point Wiring. Point 105 5 Supplying and erecting integrated LED Highbay Fitting 100W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min. 15000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L50B50 , including driver complete with 2 Year warranty as per specification No. FG-ODF/LED. 5.1 DG Area 5.2 Transformer Area 5.3 LT Room 5.4 Transformer Room 5.5 HT Room Sq Ft Nos 100 W Highbay Nos. 25 Sub : Balance Electrical Works at Business Facilitaion Center (BFC) Building ELECTICAL WORKS AT BUSINESS FACILITATION CENTER (BFC), ITEMS AT SR NO. 1 TO 46 Preperation & Placement of Checker Plate 900 TPN DB 2 6 Supply , Installation & Commissioning of Exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 900 RPM Fans including protection grill, mounting bracket , related civil works, i.e. cut out in the wall etc., as per specification no. FG-FN/EXF as detailed below, 6.1 Transformer Room 6.2 LT Room 6.3 Battery Room 6.4 HT Room (600x600) 6.5 First Floor 6.6 Second Floor 6.7 Third Floor 6.8 Fourth Floor 6.9 Fourth Floor (Toilet Room) 7 Supplying ,erecting and commissioning of Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, Max. Energy Consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control, Temperature Rise of 7.1 LT Room 7.2 HT Room 7.3 Battery Room 7.4 Green Rooms (Fourth Floor) 8 Supply and Installation of 40 W LED Tubelights including Wiring from existing network and Hanger frames for ceiling mounted fittings as detailed below, 8.1 Transformer Room 8.2 LT Room 8.3 Battery Room 8.4 HT Room 8.5 Green Rooms (Fourth Floor) 9 Supply, Installation & Commissioning of 2x2, 35W LED Panel Light having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete as per specification No. FGIDF/LED. for Fourth Floor (Toilet Room) 9.1 4th Floor Toilet 9.2 Auditorium 10 Cable - Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL, Cable through provided cable trench 10.1 LT Room to 2nd Floor 10.2 Floor to Floor 10.3 BFC to PUB 11 Cable 1100 V, 4 core 4 sq. mm. copper Cable - DG Sensing Cable - Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU - DG to 2nd Floor and Floor to Floor Mtrs. 300 12 Cable, 1100 V 3½ core 35 sq. mm. aluminium Cable - Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed GI strip armoured (strip) cable, 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL from existing cable trench GFDB to Street Light DB Mtrs. 50 Nos. Nos. Nos. Nos Mtrs. 2x2, 35W LED Panel Light 6 Cable, 1100 V 3½ core 185 sq. mm. aluminium 1000 BLDC Ceiling fan 13 40 W LED Tubelights 50 Exhaust fan heavy duty 17 13 Cable Gland for 3½core 185 sq mm Supplying & erecting single compression type brass cable glands for 3½core 185 sq mm cable as per specification No. CBGL Set 20 14 Lugs for cable 185 sq mm Supplying & erecting crimping type aluminium lugs for cable 185 sq mm complete as per specification No. CB-CL/AL Nos. 54 15 Lugs for cable 95 sq mm Supplying & erecting crimping type aluminium lugs for cable 95 sq mm complete as per specification No. CB-CL/AL Nos. 18 16 Cable Tray Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG GI sheet of 300 mm width & 100 mm height with required standard accessories Mtrs. 200 17 LED square / circular Min. 18 W down lighter Supplying and erecting LED square / circular Min. 18 W down lighter /Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B0 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FGIDF/LED. for Fourth Floor Passage Area including fixing on false ceilings. Nos. 7 18 Gravel/Blasted Rubble stone Supply and Spreading of Gravel/Blasted Rubble stone of size Aggregate 12-25 mm in the area upto the depth of say 400 mm below ground level around the DG foundations Cu. Mtrs. 60 19 Brackets for cable trays Proviing supporting brackets for cable trays. fabricated from ISMC 75 channels for installation of cable trays for laying of LT cables in the sub-station basement, a complete job including bending, cutting, drilling and welding with one coat of red oxide and two coat of enamel paint as per site requirement and instructions of the EIC. Kg. 500 20 50 mm DWC pipe Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. Mtrs. 100 21 90 mm DWC pipe Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. Mtrs. 900 22 Making Trench hard murmur Making trench in Hard murum/Tar road having 0.75m depth and minimum 0.3m width for laying provided cables up to voltage level 1.1kV cable complete as per specification no. CWEXN-CTR Mtrs. 100 23 Excavating Hard rock Excavating Hard rock or bituminous road by chiselling for preparing pit for pole/ stay/ earth plate/ for laying cable/ pipe & clearing the site by removing debris & making the site as required complete Cu. Mtrs. 100 Distribution Panels as detailed below, 24 ACDB Panel Supply, Installation and Commissioning of ACDB Panel mounted with Provision of Outgoing Feeders as per SLD. Which comprises Auto Transfer Controller with Two Incomer Feeder on priority base. At Second Floor (I/C 400A 4P MCCB - 02 Nos and O/G 200A 4P MCCB - 05 Nos.) Nos. 1 25 Ground Floor Meter Panel Supply, Installation and Commissioning of Distribution Panel for provision of DF Consumers metering (14 Nos. 3 phase dual source meters at Ground Floor…... Meters are not in the scope of the contractors…...(Meters will be provided by JNPA/Consumers at the time of connection release) I/C 200A 4P MCCB, TPN 32A - 14 Nos. Nos. 1 26 First Floor Meter Panel Supply, Installation and Commissioning of Distribution Panel for provision of DF Consumers metering (18 Nos. 3 phase dual source meters at First Floor…... Meters are not in the scope of the contractors…...(Meters will be provided by JNPA/Consumers at the time of connection release) I/C 200A 4P MCCB, TPN 32A - 18 Nos. Nos. 1 27 Second Floor Meter Panel Supply, Installation and Commissioning of Distribution Panel for provision of DF Consumers metering (16 Nos. 3 phase dual source meters at Second Floor…... Meters are not in the scope of the contractors…...(Meters will be provided by JNPA/Consumers at the time of connection release) I/C 200A 4P MCCB, TPN 32A - 16 Nos. Nos. 1 28 Third Floor Meter Panel Supply, Installation and Commissioning of Distribution Panel for provision of DF Consumers metering (14 Nos. 3 phase dual source meters at Third Floor…... Meters are not in the scope of the contractors…...(Meters will be provided by JNPA/Consumers at the time of connection release) I/C 200A 4P MCCB, TPN 32A - 14 Nos.. Nos. 1 29 Fourth Floor Meter Panel Supply, Installation and Commissioning of Distribution Panel for provision of DF Consumers metering (10 Nos. 3 phase dual source meters at Fourth Floor…... Meters are not in the scope of the contractors…...(Meters will be provided by JNPA/Consumers at the time of connection release) I/C 200A 4P MCCB, TPN 32A - 10 Nos.. Nos. 1 30 Supply and Installation of DB mounted on wall with IP Protection for provision of Three Phase (TPN 16A 1 Nos) Power supply for other utilities at Tranformer Room, HT Room 30.1 Transformer Room 30.2 LT Room 30.3 HT Room 30.4 Battery Room 31 Shifting of AMF Panel & Erection Shifting of AMF Panel from Admin Substation to BFC Substation (3 Km) including wiring required for Auto operation DG operation, Connection and Disconnection of Power cable from existing Panel to shifted new panels, Shifting of existing panel to location as directed by Engineer-In-Charge. The same Installation, Testing and Commissioining of AMF Panel. Job 1 32 Shifting of pole & Erection on Pole Foundation Shifting of pole (7 Meters) from (BFC Back side 200 Meters), The pole foundation is present at site. The Erection and Installation of street light pole including wiring and necessary accessories. Nos. 1 33 Earth Pit Construction of Earth Pit (400mm x 400mm) around the Earthing Electrode including arrangement of opening cover made of SS or Fibre, Painting (Yellow Colour) and Marking of Nomenclature, Measured Value, Testing Date and Due date Nos. 10 34 100A MCCB Supply, Installation & comissioning of 100A MCCB Main Breaker at Second Floor distribution panel Nos. 1 35 Lighting arrestor Supply, Installation and Commissioning of ESE Lighting arrestor on top of building including earthing pits, GI Strips and Chambers. Compliance With NFC 17-102, IS 62305 Triggering Time : > 60 Microseconds Protection Radius : 100 Meters Material : SS304 Operating Temp.: -20⁰C to +85⁰C Mounting Height : Min. 5 Meter Down Conductor : 25x5MM GI Strip or 2 x 70Sqmm Cu Flexible Cable (Green) Earthing System : Chemical Earthing with low resistance Nos. 1 36 Earthing for Lighting arrestor Air terminal (lightning rod) made of Copper minimum 25 mm diameter × 1000 mm length, mounted on suitable FRP / GI mast with base plate & clamps. Copper down conductor (25 × 5 mm strip) run from air terminal to earth. Earth termination system with earth electrode (copperbonded rod 17 mm dia × 3 m length / GI pipe earthing 50 mm dia × 3 m length) including earth pit chamber with CI cover, watering pipe, and backfill as per IS 3043. All accessories such as clamps, saddles, conductor holders, and test links. Installation as per IS/IEC 62305 and IS 2309, complete with continuity testing and earth resistance measurement.” Nos 5 3 Phase DB Nos. 4 37 SITC of 40 KVA UPS Supplying, erecting, testing & commisioning of 40 kVA capacity on line pure sine wave, PWM, IGBT based UPS with 0.9 to unity output pf ,3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS, and Battery Bank (including SITC of VRLA (Dry) required for 1 hours back up for UPS system above mention UPS Batterires. Nos 1 38 Cable 4c x 16 sq.mm Cu. Cable - Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU Mtrs. 100 39 SITC of SVG Plus Unit Supply, installation, Testing and commissioning of 125 KVAR required capacity SVG Plus Unit with all accessories for Improvement of Power Factor/ Harmonics) Nos 1 40 Supplying, erecting, testing and commissioning of water level controller 230/415 V, A.C. supply , four way under ground & over head tank operation only. SS Probe sensor switch for water level controller working on 250 V & rated current 8A, with 2 m wire & high quality of wire & plastic body at BFC building, near PUB Building, Outside Port Area. 40.1 WATER LEVEL CONTROLLER-Submersible, Monoblock and Openwell Pump controlling both suction and delivery tank with help of sensors. 40.2 7/38 4 CORE SHD CABLE-Multistrand Tin copper conductors, 40.3 PVC Insulated 4cores, Laying together to from A bunch, SENSOR-Stainless Steel Prob with PVC Covering. 40.4 JOINT KIT- Conduct, saddle, Screw, Raul Plug, Insulation Tape, 40.5 Waterproof Tape, Cable Tie, Reti, Cement, Concrete Nail etc. INSTALLATION CHARGES- One Time with all necessary accessories & Labour work. 41 Supplying, erecting, testing and commissioning of water level controller 230/415 V, A.C. supply , four way under ground & over head tank operation only. SS Probe sensor switch for water level controller working on 250 V & rated current 8A, with 2 m wire & high quality of wire & plastic body at PFC building 41.1 WATER LEVEL CONTROLLER-Submersible, Monoblock and Openwell Pump controlling both suction and delivery tank with help of sensors. 41.2 7/38 4 CORE SHD CABLE-Multistrand Tin copper conductors, 41.3 PVC Insulated 4cores, Laying together to from A bunch, SENSOR-Stainless Steel Prob with PVC Covering. 41.4 JOINT KIT- Conduct, saddle, Screw, Raul Plug, Insulation Tape, 41.5 Waterproof Tape, Cable Tie, Reti, Cement, Concrete Nail etc. INSTALLATION CHARGES- One Time with all necessary accessories & Labour work 42 Change Over Supplying & erecting ON LOAD change over switch 4 Pole, 415V, 400A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3 as per specification no. SWSWR/COS. along with enclosure, With cable entry from top and bottom Nos. 1 43 Dressing of @200 mtrs. Cables in cable duct At around 200 mts of the existing underground / duct cable without damaging it with glands, cable end box including refilling the trench up to ground level and making coils complete. Mtrs. 200 44 Removing the existing meter panel Removing the existing meter panel (single phase meter panel already fixed) in 1st floor and shifting in Administration building. Nos. 1 45 Cable, 1100 V, 4 core 6 sq. mm. copper conductor Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU Mtrs. 650 46 4 pole RCCB 16/25A Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB Nos. 12

Key Value

Document Fees
Refer document
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail