Tender For Providing And Fixing Of Aluminium Partition (First Floor) And Waterproofing Treatment For Terraces Of East Wing Of Care Building At Csir-Clri, Adyar, Chennai-600020.; 1 CIVIL Items 2 WOOD AND P. V. C. WORKProvidingandfixingaluminiumextrudedsectionbodytubulartype universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 3 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 125 mm 4 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper 5 FINISHINGProviding andapplyingplaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. 6 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 7 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Painting with aluminium paint of approved brand and manufacture to give an even shade.Two or more coats on new work 8 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approvedbrandandmanufacture,includingapplyingadditionalcoats wherever required to achieve even shade and colour.Two coats 9 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 10 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 11 REPAIRS TO BUILDINGRepairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand) 12 Providingandlaying APP(AtacticPolypropylenePolymer)modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane: 3 mm thick 13 ALUMINIUM WORKProviding and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 14 Forshuttersofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 15 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides 16 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket 3M glass sticker and CSIR-CLRI Logo etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) 17 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer- in-charge.With stainless steel cover plate minimum 1.25 mm thickness 18 Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 19 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/ structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 Upto 10 mm depth and 10 mm width 20 Removing existing APP Sheet/tarfelt/raking out roof tile joint/removing tree plant including roots on roof and rainwater pipe mouth etc/ and preparing surface with wire brush clean the dust partilce etc complete, disposal ofremoved sheetto be taken out from CLRI campus at the risk and cost of the contractor, other debris as directed by Engineer In Charge. 21 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment .Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement: 2 Coarse sand) to match the existing floor: Anti-Termite Treatment- Post ConstructionOperation Details(i) Drilling at every one foot interval at wall and floor junction.(ii) Drill depth 4-5 inches on both sides.(iii) chemical used- Imidachloprid 30.5 S.C.[Bayer India or equivalent](iv) Chemical injection done very half an hour up to saturation point(min 4-5 times).(v) Complete electrical conduits /junction boxes chemical treatment.[oil based](vi) Plugging of holes after chemical injuction.(vii) On completion of work a warranty for a period 5 years is given for the site.(viii) Dliute and injecting Chemical emulision for POST CONSTRUCTIONAL anti-termitetreatment(Including the cost of chemical emulsion) (ix) Treatment of existing mansory using chemical emulsion @ one litre per hole at 300mm interval them with cement motar 1:2 (1 cement: 2 coarse sand ) to the full depth of the hole with Imidachlopride chemical.(x).All round the wooden doors and windows@300mm C/C interval. 22 Repair of false ceiling including removing, replacement of tees, angles, 600x600mm new false ceiling tiles matching with existing tiles, leveling,silicon sealent and required support etc complete as per the direction of Engineering-In-Charge. [Repaired area will be measured for payment] 23 ELECTRICAL Items 24 MODULAR LIGHT/FAN PT: Wiring for light / fan / exhaust fan / call bell point with 1.5sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable size GI. box and earthing the point with 1.5sqmm. FRLS PVC insulated copper conductor single core cable etc., as required. 25 A.C. POINT: Supplying and fixingsuitable size G.I box with modular plate and cover in front on surface/recessed including providing and fixing 25Asocket outlet and25A modular SP MCB,C curve includingconnections, testing and commissioning etc.as required. 26 CIRCUIT WIRING : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 27 CIRCUIT WIRING : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire 28 MODULAR 15A SWITCH : Supplying and fixing following modular switch on the existing modular plate & switch box including connections but modular plate etc. as required.15/16 amp switch 29 MODULAR 15ASOCKET : Supplying and fixing following modular socket on the existing modular plate & switch box including connections but modular plate etc. as required.6 pin 5/16 amp socket outlet 30 MODULAR 5A SWITCH: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but modular plate etc. as required.5/6 amp switch 31 MODULAR 5A SOCKET : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but modular plate etc. as required.5/6 amp socket 32 GI/PVC Box alongwith modular base & cover plate : Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches & sockets and junction box in recess etc as required. 2 Module (75mm x 75mm ) 33 GI/PVC Box alongwith modular base & cover plate : Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches & sockets and junction box in recess etc as required. 12 Module (200mm x 150mm ) 34 WALL MOUNTING BLDC FAN:Supply, installation and testing of 400mm sweep wall mounting bldc fan 230V suitable wall colour with necessary oscillation control, fixing of suitable clamps, remote etc., as required400MM 35 Making hole50mm in Wall : Making hole through wall & providing PVC pipe (50mm) for installation of AC outdoor unit pipe & cable by demolishing brick work manually and the same as good finishing of wall by plastering etc as required. 36 LED PANEL LIGHT: Supply, Installation, testing and commissioning of Pre-wired LED fitting 36W/230V/6500K complete with all accessories etc., directly mounted on Gypsum/(2x2) false ceiling/ recess with suitable metal angle clamps including chain fixing, including earthing etc., as required.