Tender For Repair/ Replacement Of Dg Set, Battery Bank, High Mast Lights And Allied Works At Dhana Mil Stn.; 1 Material & labour for Maintenance and servicing of DG setof capacity 140 KVAdraining out of diesel from tank, cleaning the tank thoroughly and refilling drained diesel, drain out engine oil from the oil sump cleaning the sump and refilling the sump with new engine oil of Make K Oil 20W/40, to its maximum level, applying petroleum jelly on the Battery terminals and cleaning the entire DG set, checking and rectification of any defects of output voltage, RPM, exhaust leakages etc. Tightening the foundation & exhaust manifold bolts & nuts and testing as directed by the Engineer in Charge including replacement of following items complete all as directed and specified by Engr -In-Charge.(a)Fuel filter element (b) Oil filter elements (c)V-Belt (d)Air cleaner filter(e) Magnet Pickup (f) Hose pipe for radiator(g) Flexible Hose for vent(h) Fuel pipe return 2 Material & labour for Maintenance and servicing of DG setof capacity 160 KVAdraining out of diesel from tank, cleaning the tank thoroughly and refilling drained diesel, drain out engine oil from the oil sump cleaning the sump and refilling the sump with new engine oil of Make K Oil 20W/40, to its maximum level, applying petroleum jelly on the Battery terminals and cleaning the entire DG set, checking and rectification of any defects of output voltage, RPM, exhaust leakages etc. Tightening the foundation & exhaust manifold bolts & nuts and testing as directed by the Engineer in Charge including replacement of following items complete all as directed and specified by Engr -In-Charge.(a)Fuel filter element (b) Oil filter elements (c)V-Belt (d)Air cleaner filter(e) Magnet Pickup (f) Hose pipe for radiator(g) Flexible Hose for vent(h) Fuel pipe return 3 Material & labour for Maintenance and servicing of DG setof capacity 30 KVAdraining out of diesel from tank, cleaning the tank thoroughly and refilling drained diesel, drain out engine oil from the oil sump cleaning the sump and refilling the sump with new engine oil of Make K Oil 20W/40, to its maximum level, applying petroleum jelly on the Battery terminals and cleaning the entire DG set, checking and rectification of any defects of output voltage, RPM, exhaust leakages etc. Tightening the foundation & exhaust manifold bolts & nuts and testing as directed by the Engineer in Charge including replacement of following items complete all as directed and specified by Engr -In-Charge.(a)Fuel filter element (b) Oil filter elements (c)V-Belt (d)Air cleaner filter(e) Magnet Pickup (f) Hose pipe for radiator(g) Flexible Hose for vent(h) Fuel pipe return 4 Material & labour for preparation of old steel surface by cleaning , stopping and rubbing down and applying two coat of synthetic enamel spray painting on old painted steel surface of existing colour including cabin (inside & outside ) of any type of DG set all as diected and specified by Engr -In-charge. 5 Material & labour for repairing of battery charger , 6-72 volts capacity by replacing Amp meter, volt meter, selector swtich, complete wiring , transformer etc including painting all as directed and directed. 6 Material & labour Engine oil 15W 40 of approved make as approved by EIC Complete all as directed. 7 Material & labour for dismantling existing unserviceable radiator and carrying out repair by draining out water/coolant,carring out pressure test and rectifying leakage by brazing/soldering test and reinstalling including topup/filling fresh coolant as on required basis all as directed and specified for DG set upto 160 KVA capacity. 8 Dismantling ofunserviceable self starter 12 volts of DG Set of capacity 160/140/30 KVA including replacment of worn out parts like bendex, piston, bush housing etc including refixing and testing complete all as specified and directed by Engr -In-charge. 9 Dismantling ofunserviceable dynamo/alternator of DG Set of capacity 140 KVA including replacment of worn out parts like carbon bushes,solenoid switch bearing, armature etc including refixing and testing complete all as specified and directed by Engr -In-charge. 10 Supply only distilled water in sealed bottle of one liter capacity complete all as specified and directed. 11 Dismantling existing inside roof sheet with insulation of DG set capacity up to 140 KVA including repair of sheet with suitable insulation complete all as specified as directed. 12 Material & labour for Earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to galvanized steel strip of size 25X4mm including 40 mm dia light grade protection,pipe 20mm dia watering pipe with funnel,CI hinged cover,PCC chamberand excavation and earth work complete all as described and shown in EP plate No 3 of SSR part I 2009 print and testing on completion all as specified and directed. 13 Supply and fix in repairs battery terminal made out of brass/bronze heavy duty suitable for 92 AH/180 AH 12 Volt Battery complete all as specified and directed. 14 Supply only Grease Multipurpose to increase equipment/ bearing life, Excellent resistance to throw off & water wash, Maximum protection offered against rust & corrosion complete all as specified and directed. 15 Comprehensive maintenance and Repair/servicing of APFC Panel of follwoingcapacity for maintaining Power factor including by replacing theconnected items etc installed for water supply installationNote : Capacitor, Contactor, MCB will be measured and paid separately.(a)90 KVAR APFC Panel at Bannad Pump House 16 (b)60 KVAR APFC Panel at Filter Pump House 17 Comprehensive maintenance and Repair/servicing of APFC Panel of follwoingcapacity for maintaining Power factor including by replacing theconnected items etc installed for Inf Bn Phase II transformersNote : Capacitor, Contactor, MCB will be measured and paid separately.(a)60 KVAR APFC Panel at 12 Maratha LI officer Mess 18 (b)60 KVAR APFC Panel at Inf Bn PH-II Area 19 Taking down unserviceable capacitor andSupply and fix in replacement cylindrical capacitor metalized poly propylene heavy duty ( MPP - H ) for three phase 440 V and 50 Hz system for permissible non - linear load 15 % of 1 KVAR capacity complete all as specified and directed. 20 All as per item No 19 above but2 KVAR capacity. Make- Neptune, L&T, Epcos 21 All as per item No 19 above but3 KVAR capacity. Make- Neptune, L&T, Epcos 22 All as per item No 19 above but6.5 KVAR capacity. Make- Neptune, L&T, Epcos 23 All as per item No 19 above but 10 KVAR capacity. Make- Neptune, L&T, Epcos 24 All as per item No 19 above but 12.5 KVAR capacity. Make- Neptune, L&T, Epcos 25 All as per item No19 above but25 KVAR capacity. Make- Neptune, L&T, Epcos 26 Supply and fixing in repair 3 pole contactor for capacitor switching 30 KVAR capacity, 220-240 Volts, 60 Hz complete all as specified and directed. Make- Cat no. UA30-30-10RA of ABB or equivalent in L&T, Schneider 27 Supply and fixing in repair 3 pole contactor for capacitor switching 12.5 KVAR capacity, 220-240 Volts, 60 Hz complete all as specified and directed. Make- Cat no. UA16-30-10RA of ABB or equivalent in L&T, Schneider 28 Supply and fixing in repair 3 pole contactor for capacitor switching 7.5 KVAR capacity, 220-240 Volts, 60 Hz complete all as specified and directed. Make- Cat no. UA9-30-10RA of ABB or equivalent in L&T, Schneider 29 Painting to existing APFC /LT panel board only one coat of synthetic enamel paint over a coat of red oxide primer after scraping, cleaning of old surface of electricpanel complete all as specified and directed. 30 Taking down unserviceable volt meter and supply and fix digital volt meter range up to 500 Volt complete all as specified and directed. 31 Taking down unserviceable Amp meter and supply and fix digital Amp meter range up to 300 Amp complete all as specified and directed. 32 Taking down unserviceable lamp indicator RYBand supply and fix led lamp indicator RYB complete all as specified and directed. 33 Comprehensive maintenance and Repair/servicing of two zone fire alarm panel by checking all connections and minor repairs complete all as specified and directed. 34 Comprehensive maintenance and Repair/servicing of six zone fire alarm panel by checking all connections and minor repairs complete all as specified and directed. 35 Material & labour for repair/servicing of two zone fire alarm control panel, 230V, AC, 50Hz including replacement of following connected unserviceable items:- (a) Battery with Charger (b) Faulty LED indicator (c) Reset/silence switch (d) Relay and complete all as specified and directed by Engr-in-charge. 36 Supply and fix smoke detector complete all as specified and directed. 37 Supply and fixing in replacement MCCB 4 pole 36 KA 400 A suitable for Adjustable type setting complete as specifed and directed. 38 All as per item No 37 above but capacity 250 A. 39 All as per item No 37 above but capacity 350 A. 40 Supply and fix bus bar chamber weather proof boxes made out of 3mm thick CRCS sheet front opening double chamber type for providing four numbers aluminium bus bar strips of 400 Amps and 300 mm long each, insulators, nuts bolts and MCCB 250 amps 4 pole 35 KA incoming including terminating the existing incoming and outgoing cables etc alongwith painting with 2 coats of synthetic enamal paint over a coat of red oxide primer complete with proper fixing arrangements of ground with angle iron supports duly grouted on floor/ground all as specified and as directed. 41 Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 42 Disconnecting and dismantling existing unserviceable Air termination rod and supplying & fixing new single pointed copper rod 12mm dia, 300mm long with all connections with bolts and nuts complete all as specified and as directed. 43 NOTE :- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs 10100.00 /- ]

Key Value

Document Fees
INR 500 /-
Tender Value
INR 8 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail