}

Tender For Special Repair To Building No T-01 (Or Living) Under Age B/R-Ii And P-11 (Single Jco Living) Of Otm Accommodation Under Age B/R-I At Tibri Mil Station Gurdaspur., gurdaspur-Punjab

Tender Notice

52063618
Tender For Special Repair To Building No T-01 (Or Living) Under Age B/R-Ii And P-11 (Single Jco Living) Of Otm Accommodation Under Age B/R-I At Tibri Mil Station Gurdaspur.
Tender
Indian
Punjab
Gurdaspur
21-11-2025

Tender Details

Tender For Special Repair To Building No T-01 (Or Living) Under Age B/R-Ii And P-11 (Single Jco Living) Of Otm Accommodation Under Age B/R-I At Tibri Mil Station Gurdaspur.; 1 Removing existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime cova 80 to 100mm thick mud phuska/cement concrete/lime cova etc, cleaning of all foreign material such as fungus mass dust etc, roughing surface of corner to roof by wire brush incl demolition of cement concrete tiles complete all as specified and directed. 2 M&L for PCC 1:2:4 type B-1 (using 20mm graded stonecrushed aggregate) as in padding levelling etc and roof kerbs complete all as directed. 3 M&L for water proofing treatment to roof slab with APP based modified polymeric membrane centre core 100mm microne HMHDPE outer flim 20 micron each having thickness 3 mm weight not less than 3kg/Sqm with 100mm overlap laid as per manuacturers instructions complete all as specified and as directed by Engineer-in-Charge with following course of description below:-(a) 1st coat applying bitumen primer confirming to IS-3384-1965 @ 0.40 Kg/Sqm to be applied on prepared roof surface till the surface is properly impregnated. (b) 2nd coat of bonding material using blown type bitumen conforming to IS-702 of grade 85/25 @ 1.20 Kg/Sqm. (c) 3rd course ie. laying of APP Based modified membrane described herein before with 100mm overlap in longitudinal direction and 150mm in transverse direction, all joints and changes in all direction should be covered covered with cement mortar (1:3) mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane.(d)Forth course of bonding material using blown grade bitumen 85/25 conforming to IS-702 @ 1.20 Kg Per Sqm and over spread course sand for making roughening the surface to receive the next layer treatment. 4 M&L applying evenly a tack coat of industrial bitumen 85/25 at the conforming to IS-702 @ 1.2 kg per sqm including cleaning surfaces complete all as specified and directed. 5 M&L for applying one coat of bituminious aluminium paint @ 0.20 Kg Per Sqm over APP membrane, complete all as specified and directed. 6 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises. 7 M&L for non-skid ceramic tiles of size7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11sqm but not exceedig 0.18 sqmin floors set and jointed in neat cement slurry and pointing in coloured cement over 15mm thick screed/bedding layer in CM (1:6) complete all as specified and directed. 8 M&L forlight coloured vitrified tiles 10mm thick (square/ rectangular) polished, area not exc 0.36 sqm, in floor etc set and jointed in neat cement slury and pointed with coloured cement to match the shade of tiles over 15mm thick screed/bedding layer in CM (1:6),complete all as specified 9 M&L forlight coloured vitrified tiles 10mm thick (square/ rectangular) polished ,area not exc 0.36 sqm, in floor etc set and jointed in neat cement slury over and pointed with coloured cement to match the shade of tilesandbacking screed 10mm thick in CM 1:4 on fair surfacess for laying tiles as in skirting and dado etc. 10 M&L for coloured glazed ceramic tiles in vertical surfaces300 x 450 x 7 mmthick set and jointed in neat cement slurry and pointed in white or coloured cement to match colour over 10mm thick backing screed in CM (1:4) complete all as specified and directed. 11 M&L for machine cut kota stone slab flooring 20-25 mm thick over 15mm thick screed bed or bedding layer in CM 1:4,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing,polishing complete all as specified & directed. (The kota stone shall be fixed in single piece). 12 M&L for machine cut kota stone slab 18-20mm thick on riser of steps ,skirting ,dado and pillar laid over cement screed bed 10mm thick in CM 1:4, jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing,polishing complete all as specified & directed. (The kota stone shall be fixed in single piece). 13 Demolition of cement concrete in ground floor & paving n exc 15 cm thick below or above ground leveling including removal , complete all as specified and directed by Engr - in-Charge. 14 M&L for 25mm thick cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in flooring, finished the surface even and fair complete all as specified and directed. 15 Taking down chowkhats with shutters (without taking off shutters from the frame) area not exceeding 1.5 Sqm each complete all as specified and directed. 16 All as per item No 15 above but area exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed. 17 Taking down shutters exc 1.00 but not exc 2.00 Sqm each complete all as specified and as directed. 18 S&F pressed steel frame for doors with one or more rebate including necessary fixing lugs, hings, lock strike, plate etc complete of size 125x60mm all as spd including one shop coat of priming and two coats of synthetic enamel paint and filling PCC 1:2:4, type-B0 (using 12.5mm graded crushed stone aggregate) in the frames complete all as specified and directed. 19 S&F pressed steel frame for doors with one or more rebate including necessary fixing lugs, hinges, lock strike, plate etc complete of size 105x60mm all as spd including one shop coat of priming and two coats of synthetic enamel paint and filling PCC 1:2:4, type-B0 (using 12.5mm graded crushed stone aggregate) in the frames complete all as specified and directed. 20 S&F 35mm thick 2nd class hard wood glazed and skelton shutters as in doors open rebated and prepare to receive glass, gauze etc (without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part-I section 8 clause 8.24 (a) complete all as directed. 21 S&F of 35mm thick modular designer flush doors, solid core construction, with block board core and pre-lamination on both sides, complete all as specified and directed. 22 M &L for box type steel window with 80 x 40 x1.25 mm MS tubular frame with side hung shutters ( double shutter for glass and gauze) without sash bars jointed together with and including , grill using12 mm square bar @ 10 cm C/C including , box type hinges with steel handle and steel pag stay complete glazing barsdoweled and welded complete all as specified as directed.(Note:-(a)The Glass / gauze shall be measured and paid separately. (b) Side hung Z-Section shutter shall be of size 20mm x 20mm x 25mm and 3.0mm thick). 23 M&L for box type steel ventilator with 80 x 40 x 1.25mm MS tubular frame partly gauged with top hung shutter with and including , grill using 12mm square bars @ 10 cm C /C includingbox type, hinges with steel handle and steel peg stay complete glazing bars dovetailed and welded complete all as specified as directed.(Note :(a)The Glass / gauze shall be measured and paid separately. (b) Top hung Z-Section shutter shall be of size 20mm x 20mm x 25mm and 3.0mm thick). 24 S&F mild steel frame work as in door or gate of angle or other section with gusset plates, rails, braces etc complete drill for fixing of steel sheeting or other covering door etc conforming to Fe-410 W Gde-E-250 quality B complete all as specified and as directed. 25 S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, supplying & fixing in opening as per specification & drawing 26 S&F factory made solid panel pace door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. 27 S&F 100mm butt hinges, medium weight, cold rolled mild steel and fixed all as specified. 28 S&F 100mm butt hinges, aluminium cast type, and fixed all as specified. 29 S&F 150 mm long aluminium handles cast type all as specified. 30 S&F 200 mm long aluminium tower bolts of extructed section section all as specified. 31 S&F 250 mm aluminium, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. 32 S&F in repairs floor door stopper140 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor all as specified. 33 Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. 34 M&L for rendering 15mm thick plastering in CM1:6 for internal surface of wall and finished even and smooth withouting using extra cement complete all as directed. 35 M&L for rendering 15mm thick plastering in CM 1:4 for external surface of wall and finished even and smooth withouting using extra cement complete all as directed. 36 Rendering 10 mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:3 and finished even and smooth without using extra cement. 37 M&L for preparation of newly plastered surface and applying two coats of oil bound distemper, over and incl a 2mm layer of wall care putty to get even and smooth level finish on new plastered surface of internal wall, complete all as specified and as directed. 38 M&L for preperation of newly plastered surface and applying three coats of white wash on newly plastered surfaces of ceiling complete all as directed. 39 M&L for prepration of newly plastered/un plastered surfaces of wall and applying two coats of cement base paint of shade as approved complete all as specified and directed. 40 M&L for prepration of old plastered surfaces of wall and applying two coats of cement base paint of shade as approved complete all as specified and directed. 41 M&L for preperation of old plastered surface and washing rubbing down of distempered and painted surface and complete removal of existing treatment andapplying two coats of oil bound distemper over a coat ofputty on old plastered surface of internal wall complete all as specified and as directed. 42 M&L for preperation of old plastered surfacesceiling and applying two coats of white wash complete all as directed. 43 Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. 44 M&L for 75mm thick cement concrete (1:3:6) type C-2 using 40mm graded stone agg finished even & smooth without using extra cement as in plinth protection including forming joint to full depth at every 3.0m informal and at every charge of direction and filled mixture of bitumen and sand (1:3) by weight complete all as specified and directed. 45 M&L for 75mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base of floor, path etc complete all as specified and directed. 46 M& for chequered cement concrete tiles 300x300x 25mm thickwith grey pigment cement and pigment, with and including cement mortar 1:3 in edges of tiles, complete as directed. 47 M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in copping for brick work, side benchingcomplete all as specified and directed. 48 S&F in replacement of bib tap, 15 mm dia with wall flange made of cast copper alloy, chromium plated, complete all as directed. 49 S&F in replacement of pillar taps, fancy type 15 mm dia, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts complete all specified and directed. 50 S&F in replacement of stop cock with long shank and cup (concealed type), 15mm dia with wall flange, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe / unions complete all as directed. 51 S&F in replacement of angular stop cock 15 mm dia with wall flange made of cast copper alloy, chromium plated fancy type, complete all as directed. 52 Taking down steel tubing with and incl connections of 15 mm dia bore, complete all specified and directed. 53 Taking down steel tubing with and incl connections of 20 mm dia bore, complete all specified and directed. 54 M&L for medium grade galvanised steel water tubing with and incl all fittings and fixtures, fixed to wall or laid in floors for 15 mm bore, concealed or exposed, complete all as specified and directed. 55 M&L for medium grade galvanised steel water tubing with and incl all fittings and fixtures, fixed to wall or laid in floors for 20 mm bore, concealed or exposed, complete all as specified and directed. 56 Dismantling unserviceable PVC water storage tank of 1000 Ltr capacityall as directed. 57 S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 1000 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, complete all as directed. 58 S&F in repairs 20 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 59 S&Fin repair 20mm ball valve high pressure of PTMT with eposy coatedaluminium rod & high density plastic ball screwed for iron pipe and fixed (min wt20mm 210 gms) as specified 60 S&F in repair for vitreous china wash down water closet pan ( pedestal pattern) white ( excluding flushing cistern and flush pipe) including plastic water closet seat white with jet, closed pattern with flat botton and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed. 61 S&F in repairs plastic water closet seat cover, black, closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device complete all as specified and directed. 62 S&F hand shower (health faucetABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube andABS wall hook including making connections and fixed in position complete in all respect as specified. 63 S&F in repair vitreous China wash hand basin, white, flat back, size 580x450mm excluding taps, waste chain and plug and porcelain stopper but including brackets, CP waste copling,including PTMT PVC connection 600mm complete all as specified and directed 64 S&F brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing tosteel pipe or union complete all as specified and directed 65 S&F in repairs 10 litres, PVC, valve less, syphonic action type, flushing cistern, high level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long complete all as specified and directed 66 S&F in repair towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/ plastic cleats complete all as specified and directed 67 S&F in repairs vitreous china squatting pan, Orissa pattern, size 580 x 440mm white with integral foot rests complete all as specified and directed 68 Supply 600mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. 69 M&L for green marble 16 to 18mm thick in steps, pillars, wndow cills, pillars, window cills, cooking platforms and like laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. 70 Taking downeaves gutter and rain water pipes including all fittings any size and pattern. 71 S&F of PVC (SWR) pipe of 110 mm nominal dia size, wall thickness of 3.5 mm, type A in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end socketed, duly fixed with cement solvent etc duly laid in trenches or in floors complete all as directed. 72 S&F of PVC (SWR) pipe of 75 mm nominal dia size, wall thickness of 3.5 mm, type A in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end socketed, duly fixed with cement solvent etc, complete pipe duly laid in trenches or in floors complete all as directed. 73 S&F of ringfit PVC (SWR) pipe of 110 mm nominal dia size, wall thickness of 3.5 mm, type A in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end as self socketed with an integral groove to hold the rubber gasket, with and incl rubber tighten gaskets, ringfit sockets etc, complete pipe duly fixed to wall complete all as specified and directed. 74 S&F of ringfit PVC (SWR) pipe of 75 mm nominal dia size, wall thickness of 3.5 mm, type A in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end as self socketed with an integral groove to hold the rubber gasket, with and incl rubber tighten gaskets, ringfit sockets etc, complete pipe duly fixed to wall complete all as specified and directed. 75 S&F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed. 76 S&F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed. 77 S&F 110 mm bore PVC (SWR) junction single (Single `T) equal or unequal. 78 S&F 75 mm bore PVC (SWR) junction single (Single `T) equal or unequal. 79 S&F PVC Floor trap of 75 mm outlet with grating including jointing to waste pipe in run lead. 80 Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified and directed 81 All as per Srl itemNo 80 above but applying one coat of synthetic enamel paint on old wooden surface. 82 M&L for reparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxideprimer, complete all as specified and directed. 83 All as per ser item No 82 above but one coat on old treated surfaces 84 S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed. 85 S&F figured glass pin headed type, 3mm thick ordinary quality, in squares, not exceeding 0.50 Sqm in each pane fixed oil putty complete all as specified and directed. 86 S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed 87 M&L for stainless steel curtain rod 25mm dia steel pipe cutting into length as required at site with and incl stainless steel end caps/lobs and stainless steel wall mounting brackets, complete all as specified and directed. 88 Demolition of brick work built in cement mortar or lime mortar including all quoins arches, pillars etc complete all as specified and directed. 89 M&L for brick work with fly ash bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and directed. 90 M&L for half brick thick wall with fly ash bricks, straight or curved on plan to any radius built in cement mortar 1:4, complete all as specified and directed. 91 M&L for RCCtype B1 1:1.5:3 (using 12.5mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, chajja, canopies, deck slabs and in shelvescomplete all as specified and directed 92 M&L for mild steel deformed TMT bars 5 mm To 10mm dia (as in reinforcement) cut to length, bent to shape require including cranking, bending spirally for hooking for column, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed 93 Form work to soffits of suspended slabs such as roof slabs, floor slabs and lintels, chajjalanding and similar work n. exc 200mm thick complete all as specified and directed 94 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc orfor shafts, wells, cesspits, manholes, pier holes cutting roads etc n.exc 10 sqm on plan and n. exc1.5 m in depth and getting out,all as specified & directed. 95 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. all as specified & directed. 96 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified & directed. 97 Demolition and breaking up old unserviceable drain pipes (Salt glazed ware, AC or Reinforced concrete)150 mm bore at any depth set in cement mortar includind PCC bed complete all as specified & directed. 98 M&L for PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) asconcrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested;complete all as specified & directed. 99 Supplying, laying in trenches ,jointing and testing reinforced concrete pipes 150mm, class NP3, laid and jointed with collars at any depth over PCC bed completeas specified. 100 S&F in replacement of PVC connection 5mm450mm long dia PTMT (PVC) complete all as directed. 101 S&F in repair vitreous China urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed 102 S&F in repairs 32mm dia waste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms) complete all as specified and directed 103 M&L for 12 mm thick rendering withready mix mortar on brick work/stone/concrete wall etc. internal surfaces finished even and smooth without using extra cement of any shape, any size complete all as specified and as directed. 104 M&L for 15 mm thick rendering of ready mix mortar on brick work/stone/concrete wall, facia, projection etc. external surfaces finished even and smooth without using extra cement complete all as specified and as directed. 105 M&L for 12 mm thick rendering with ready mix mortar on brick work/stone/concrete wall etc. internal surfaces finished even and smooth without using extra cementincl taking down existing plaster of any size incl raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. 106 M&L for 5 mm thick rendering with ready mix mortar on brick work/stone/concrete wall etc. internal surfaces finished even and smooth without using extra cementincl taking down existing plaster of any size incl raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. 107 M&L for 15 mm thick rendering with ready mix mortaron brick work/stone/concrete wall, facia, projection, chajja etc. external surfaces finished even and smooth without using extra cement incl taking down existing plaster of any size incl raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. 108 M&L for complete removal of existing treatment, preparation of old surface and applying two coats of cement base painton wallcomplete all as specified and directed. 109 M&L for chipping off existing loose, damaged concrete from RCC members of all affected RCC columns, beams, slabs and chajjas on external and internal facades, etc for providingPMM (Polymer modified cementitious mortar):- (i) Dry sub strate surface and free of debris & dust. (ii)Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes. (iii)Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of n exc 50 mm thickness.Note :Application of PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as rcommended by manufacturer complete all as specified and directed. Note: - Cost of formwork, bldght upto 12 mtr, shall be deemed to be included in unit rate quoted by the Contractor. 110 Demolition stone slabs and tiles of any description or thickness in floors, aprons, counter platforms etc complete all as specified and directed. 111 S&F steel windowbox type made of ERW tube hollow P section of size 60mmX25mm double rebated outer frame comprising double shutters i.e. guaged skelton & glazed, shutter frame of ERW tube P section size50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and FI 2mm thick welded/ screwed to frame for fixing of wire gauge including MS guard bars, fittings and fixtures welded to frame/ shutters as given below and all as shown on drg No. CEJZ/TD-1020/08 Sh 1/3 to 3/3 incl one shop coat of priming and two coat of synthetic enamel paint and taking down old existing window complete: :-(i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window(ii)Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii)MS Tower bolt 150mm long-02 Nos per leaf(iv)Z section 20mmX25mm,100mm long stopper -01 Nos per leaf(v)Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi)MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window).(viii) Painting with one shop coat of zinc chromate primer. Note: Wire cloth, glass shall be measured and paid for separately 112 S&F 200mm bore PVC (SWR) ISI marks pipes single socketed in any length with rubber ring joints fixed to wall, floor upto 12m height complete all as specified and directed. 113 S&F powder coatedanodised aluminiumframefor doors, windows, ventilator etc side hung one or more rebates including necessary jointing cleats, glazing clips complete all as specified and directed 114 Taking down old existing steel window/ventilator incl all fittings complete all as specified. 115 S&F 3mm thick acrylic sheet transparent glass ordinary quality and glazing with silicon and filling gap with oil putty in squares n exc1.00 Sqm each fix on steel, wooden etc frame complete all as specified and directed. 116 S&F 35 mm thickfactory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides incl 6mm thick lipping of sides complete all as specified and directed. 117 S&F factory made single extruded WPC solid door frames/ chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed stainless steel screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimumcompressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/stainless steel dash fasteners ofdia and length complete as per direction of Engineer-in-Charge. 118 S&F 30 mm thick factory made single extruded WPC solid plain flush door shutter comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk stainless steel screws, all as per direction of Engineer-In-Charge. 119 S&F in repair 25 mm thick block boards, grade 1 quality, interior grade, laminated on both side with decorative choice laminationfixed with screws to steel frame work for shelves etc. Incl 6mm thick lipping fixed with nails on all sides on cupboard, kitchen cabinets and like complete all as specified and directed by EIC. 120 S&F 75mm sizehasp and staple safety type aluminium anodised brass with mild steel hinge pin including bolt to hinge plate and fixed with screw complete all as specified and directed. 121 S&F mild steel work Fe 410-W(Gde-E- 250) quality-A Fe in framed work as in door frame, shutter or gates of angle iron or other section with gusset plates,rails,braces etc complete drilled for fixing of steel sheeting or orther covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also fastening complete all as specified and directed 122 S&F for aluminiumanodized barel tower bolt of extruded section 150mm longcomplete all as specified and directed. 123 S&F for aluminium alloy, anodised, 300 mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts, sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. 124 S&F in repair 300mm, mild steel ordinary rat tail rod pattern springs, including roller and roller plate joint through welding/bolt in metal/wooden frame to be carried out or necessary alternative arrangements to be done complete all as specified and directed. 125 S&F rotational moulded polytheylene triple layered white water storage tanks of capacity 500 Litres(cylindrical vertical with closed top) hoisted and fixed in position including dismantling of existing water tank and 20mm dia brass float valve with brass rod complete all as specified. 126 S&F in repair PVC connections 15 mm size with PTMT nuts of length 600 mmcomplete all as specified and directed. 127 S&F in repair stop valves or angel valve 15mm bore fancy type chromium plated alloy with butterfly handle screwed down for high pressure, screwed on both ends, fixed with iron pipe etc complete all as specified and directed. 128 S&F in repair stop valves cast copper alloy 15mm bore fancy type chromium plated alloy with long shank and cup concealed type all as specified and directed.. 129 S&F for 600mm x 450mmbeveled edge mirror of selected quality glass fancy type fixed withwooden plugs chromium plated brass screws and cup washers complete all as specified and directed. 130 M&L for water proofing treatment to sunkem floors of kitchen, toilets, laboratories, bath and WCs etc shall be as under:-(i) Application of two component acrylic modified cementitious coating(a) The surface to beapplied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance existing coating and achieve a gripping profile that is clean, dry and free from laitance and any other form of surface containmation. The installation instruction in manufacturers published literature shall be strictly complied with, including but not limited to the following:-(b) Chipping out any visible cracks in V-Groove pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/Dr. Fixit 302 SBR latex/ perma latex SBR/FOSROC Nitbond SBR latex/Asian paint latex as required. Final cleaning of surface with powder grinder, wire brush, hair brush & vacum pressure (c) Providing PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) of 50mm thick admixed with SIKA plastocrete over the applied water proofing coating on horizontal surfaces.(Admixture: Sikaplastocrete plus/FOSROC/Dr. Fixit/STP/CICO confirming to IS 2645.) (d)Dampen all surface immediately ahead of apllication of acrylic modified cementitious coating of SIKA top seal-107/Brush bomd FOSROC/Dr. Fixit/STP/CICO. 131 (e) Whilst the surface is still damp from saturation (SSD) apply one coat of acrylic modified cementitious coating of SIKA top seal-107/ Brush bond FOSROC/Dr. Fixit/STP/ whilst of the first coat is wet. (f) Apply glass fabric sheet of SIKA Fab 1/FOSROC/Dr. Fixit/STP whilist the first coat is wet.(g) Once touch dry, apply second coat of acrylic modified cementitious coating of SIKA top seal-107/Brush bond FOSROC/Dr. Fixit/STP/CICO of viscosity as per manufacturer ins on the entire area. Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat. (h) The waterproofing coating shall be taken to a height minimum 300mm above the finished floor level on the vertical surface.(j) It is essential to cure acrylic modified cementitious coating immediately after application (min 6-8 hrs drying) for a min of 3 to 5 days to ensure full cement hydration and to minimize cracking. (k) A protection plaster (15mm thick) in ready mix mortar admixed with appropriate integral water proffing compound has to be a apllied on the walls(.Admixture: Sikaplastocrete plus/FOSROC/Dr. Fixit/STP/CICO confirming to IS 2645.) (l) All the corners and joints shall be pretreated with an elastic waterproofing sealing tape with a woven bonding mesh on each surface and an elastic expansion zone in the centre of make seal tape SIKA/FOSROC/Dr. Fixit/STP. (m) The membrane has to be protected in accordance with the manufacturers recoomendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturers recommendations. 132 (n)Waterproofing treatment has to be carried out through applicators authorised. (o)All the joints of pipes and traps within the sunken portion shall be sealed properly by epoxy sealant.(p) All CI/PVC Traps in sunken slabs to be enclosed with PCC 1:1.5:3 (min 15cm) allround. (q) The sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40mm graded crushed stone aggregate) complete all as specified.(r)Providing drainage spout pipe GI 40mm dia bore light grade upto outside of outer wall (Approx 300 mm long) incl cutting to existing wall and making good the distrubed surface complete all as specified and directed.(s) Providing 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in flooring for laying floor finishes all as specified. Note:- Items no.(q), (r) and (s) shall be measured and paid for seperately. 133 M&L for PCC 1:5:10, type E-2 (using 40mm graded crushed stone aggregate) as in filling foundation and mass conc in sunken floor complete all as specified and directed. 134 M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base complete all as specified and directed. 135 Dismantling of roof brick tiles fixed in cement mortar in single layer all as directed. 136 Demolition mud phuska in roofs any thickness includingleeping plaster complete all as specified and directed. 137 Roughing the surface of old concrete floor picking sweeping clean and washing down with water to remove dust/mud etc.and brushing neat cement slurry @ 3kg/Sqm complete all as specified and directed. 138 M&L for cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in roof padding averaging thickness of 50 mm complete all as specified and directed. 139 M&L for APP based polymeric membrane minimum weighing 3 kg/ sqm and minimum 3mm thick, reinforced with polyster non woven fabric (weight not less than 150 gms/ Sqm) including bitumen primer @ 0.40 kg /Sqm by forced application with butane torch over entire roof area with minimum overlaps of 100mm at the sides/ longitudinal edges of strips membrane and 150mm at the ends and sealed complete all as specified and directed and all as per manufacturers instructions. 140 M&L for 40mm thick brick tile laid over 15mm thick ready mix mortar bedding layer in grouting and pointing with CM (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed by Engineer-in-Charge. 141 All a per Srl item No 140 here-in-before but except tiles (old serviceable dismantled tiles obtained from Srl item No 135 shall be reused after necessary cleaning of mortar)all as specified and as directed by Engr-in-Charge. 142 M&L for PCC 1:2:4 type B-1 (using 12.50mm graded crushed stone aggregate) as in roof kerbs, kerb, coping etc. complete all as specified and directed. 143 M&L for brickwork with old size sub class B bricks, straight or curved on plan exc 6m meanradius built in CM1:6 complete all as specified & directed by Engr-in-Charge. 144 Demolition of RCC as infascia, projection, chajja, parapet, shelves etc of any description incl cutting of reinforcementt of chajja, fascia, parapet,projection, shelvesetc. with to 12m ht of bldg complete all as specified and directed by Engr-in-charge. 145 Form work to rough finished surface of concrete flat and soffits ofshelve, chajja, fins etc including supports over hangs upto 12m height all as specified & directed. 146 M&L for RCC in 1:2:4 type B-0(using 12.5 mm graded crushed stone aggregate) as in chajjas facia, shelves, lintel etc and similar work complete all as specified and directed. 147 Providing precast cement concretein landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces 1:2:4 type B1(20mm graded crushed stone aggregate) set in cement motar in1:4, including form work complete all as specified and directed. 148 S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick, ISI marked any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, crumple joint etc fixed with self tapping screws as required complete all as specified and directed by Engineer-in-Charge. 149 Dismantling of cast iron, PVC or SGSW drain pipes, jointed in cement mortar and taking out of trenches, if required. 150 M&Lin repair for PVC(SWR) floor trap plainincluding jointing with solvent cement100mm dia complete all as specified and directed. 151 S&F for stack clamps (110 mm pipe)made out of 20x1.5 mm galvanised mild steel incl stays, bolt and nuts and securing ends of stays to wall or roof complete all as specified and directed. 152 M&L for PCC 1:4:8 type D-2 (using 40 mm gradedcrushed stone aggregate) as in sub base etc complete all as specified & directed by Engineer-in-Charge. 153 M&L for 60 mm thick PCC (M-35) factory made with gray cement and no pigment interlocking tiles/ paver block of shape/ size as conforming to IS 15658, joints will be filled with fine sand, incl dismantling existing tiles complete all as specified and as directed by Engr-in-Charge.(Note:-Sand will be paid under relavent item). 154 M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge. 155 Bailing out sludge from manholesof any size manually or with the help of pump as per site condition and disposal of sludge, solids foul material obtained to any distance exc 500 mtr in low lying area, including removing and refixing manhole covers and flushing with adequate water the depth of manhole not exc 1.0 mall as directed by Engineer-in Charge. 156 E/M PORTION Taking down carefully aluminium/ copper point wiring for light, fan, bell, socket of point complete fiitings such as switches, ceiling roses, pendents, regulator socket etc complete at site and making goods disturbed surfaces of walls, floors etc complete all as specified and directed. 157 M&L for point wiringwith PVC insulated and PVC unsheathed multistranded FRLSH copper conductor cable of size 1.5 Sqmm including existing concealed PVC conduit fittings and making good to the disturbed surfaces with continuous earth wire of copper 1.5 Sqmm dia to commonearth including provn of 3mm thick plastic laminated sheet of appropriate size and fixing to CI/MS boxes for mounting of accessories like surfaces sockets and regulators etc. complete all as specified for One light / Fan/ bell point controlled by one way switch complete all as specified and directed. 158 All as per Srl item No 157 above but one 5 amp socket outlet on independent board. 159 All as per Srl item No 157 bove but one 5 pin socket outlet 5 amp on same board. 160 All as per serial item No.157 here-in-before butwiring with 2.5 sqmm FRLSH copper wire including earth wire 2.5 Sqmm of copper for 15 Amps 3 pin socket outlet. 161 M&L for sub main wiring with two runs of single core multi stranded PVC insulated, copper conductor, grade 1100 Volt, FRLSH cable of size 6 sqmm (red for phase and black for neutral) including PVC conduits not less than 1.2 mm thick and 25mm dia and 6 sqmm multistranded copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete including taking down old unserviceable wiring complete all as specified and directed.Note :- (a) Cost of making good the disturbed surface plastering/ filling putty alongwith matching with the existing surface is deemed to be included in the quoted rate by contractor.(b) Three run of cable alongwith PVC conduit together shall be measured as single run. 162 S&F switch piano flush type single pole one way 5 amps complete all as specified and directed. 163 S&F socket outlet 3 pin 5 amps flush type complete all as specified and directed. 164 S&F switch flush type 15 amps single pole type one way complete all as specified and directed. 165 S&F socket outlet 3 pin 15 amps flush type complete all as specified and directed. 166 S&F in replacement of LED tube light fitting wall mounted with single side connection polycarbonate LED batten with aluminiumhousing and integrated electronic driver of capacity 20W, four feet and connection with PVC insulated twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed. 167 S&Fwall /ceiling mounting LED 9/10 watt tube light fitting complete withall acessories 1x9 Watt LED ,with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz,and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection complete all as specified and directed. 168 S&F decorative 9W,LED wall mounting fittings complete set including 9W LED lamp 9 Watt polycarbonate typeB-22complete all as specifed and directed. 169 S&F PVC insulated sheathedcopperwire 1.5 sqmm FRLSH single core 1100 volt for inverter connection in same conduitall as specified and directed 170 S&F fan regulator electronic type5 step 100 watts,240 volt and connecting complete all as specified and directed. 171 S&F electric bell ding dong, AC, 230 volts, single pole complete all as specified and directed. 172 S&Fbellpush flush type6 Amp complete all as specified and directed. 173 S&F lamp holder, PVC/ polycarbonate type insulated body with back plate suitable for batten / angle fittings complete all as specified and directed. 174 S&F ceiling rose, surface bakelite 65x50mm three terminal all as specified and directed. 175 S&F in replacement GI pipe bracket made out of GI pipe light grade 32 mm bore and bent to shape 1.5m long, MS clamps made out of MS flat iron of size 32mmthick with nuts, bolts and washers complete including dismentling the existing GI pipe bracket and drilling of holes for nuts and bolts etc complete all as specified and directed. 176 S&F LED security light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact andcorrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. 177 S&F in repair sheet metalenclosure forDB’s when MCB’s to beused of 240 volt 8 way with 200 amps ratedbus bar SPNdouble door complete all asspecified anddirected. (Note :- All the connection of incoming and out going wire in MCB will be made with thimble with suitable size as directed). 178 S&F in repair MCBsinglepole 6amps to 32 amps, complete all asspecified anddirected. 179 All as per Srl item No 178 here-in-before but single pole and neutral 32 amps complete all as specified and directed. 180 All as per Srl item No 178 here-in-before but 40 to 63 Amps. 181 M&L for replacement of distribution board made out of CRCA sheetDB vertical type double door TPN 4 Way MS sheetincluding fixing to wall, cutting chases, grounting and necessary patch work and white wash to match with the existing including making connections all as directed containing thefolowings:-(a)MCCB 4 pole 63 amps 16 KA breaking capacity with thermal release:01 No(In coming). (b)Bus bar made out of aluminiumduly insulated wire adhesive tape RYB & black :4 Nos. (c) MCB SPN 40 Amp- 4 Nos, MCB SP 40 Amp- 04 Nos (out going).(d)Connection from MCCB to bus bar will be made with aluminium strip of suitable size as directed.(Note :- All the connection of incoming and out going wirein MCCB and MCB will be made with thimble with suitable size as directed). 182 M&L for earthing complete with galvanised steel earth plate electrode 60cm ×60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point including testing on completion including watering GI pipe 20mm bore medium grade, 15mm bore light grade GI pipe for protection of earth lead including provision ofconcrete pit in PCC (1:3:6) type C-1, pre-cast RCC (1:2:4) MS bar funnel & wire mesh, excavation and earth work in any type of soil includingdismantling existing earthing complete all as specified & directed by Engr-in-charge. 183 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete al as specified and directed. 184 Supply and lay brick common burnt sub class B old size for protection of cable laid in trenches for under ground cable all as specified. 185 M&L for sand cushioning in trenches using fine sand to under ground cable, laid in two layers15cm before laying the cable and 8cm after laying the cablecomplete all as specified. 186 M&L for GI tubinglight grade fixed along the pole/under road/along the wall of size 40 mm bore with necessary clamps all as directed. 187 A Schedule of Credit for old/unserviceable demolished/ dismantled items has been catered for in the tender.The Schedule of Credit is pre-priced by MES.The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit Rs. 64,871.50 from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 43 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail