Tender For Certain Sanctioned Special Repair Works At Miran Sahib Under Ge Jammu; 1 B/R Portion: -Demolition of brick work/ stone masonry built in cement mortar including all quoins, arches, pillars, but excluding pre-cast concrete articles complete all as specified and as directed. 2 Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. 3 Demolition of cement concrete of any description and in any position and removing the rubbish from work site complete all as specified and as directed. 4 Demolition/ breaking of drain pipes set in cement mortar and taking out off trenches and removing the debris from the site all as specified of 150mm/ 200 mm dia pipe including demolition of cement concrete haunching etc complete all as specified and as directed. 5 Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, drains etc but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and as directed. 6 Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. 7 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing unserviceable tiles to store and rubbish off the premises complete all as specified and as directed. 8 Dismantling wall and ceiling boards (fibre, pulp, insulation etc), or insulation boards/ slabs/ blankets, any thickness any type including cover fillets complete all as specified and as directed. 9 Dismantling wrought iron or mild steel work as in wind tie, grill grating, cooler stand etc complete all as specified and as directed. 10 Dismantling unframed work timber scantling 40 Sqcm and over in section in any position as in unframed work complete all as specified and as directed. 11 Dismantling timber scantling in fillets, posts, rafters, purlins etc under 40 Sqcm in section complete all as specified and as directed. 12 Dismantling AC corrugated, semi corrugated sheets in roof covering including ridge complete all as specified and as directed. 13 Dismantling stone slabs laid dry and tiles of any description or thickness in floors, aprons etc. and rubbish off the premises complete all as specified and as directed. 14 Taking down roof trusses, coupled rafters or trussed beams above 4 metres and upto 8 metres complete all as specified and as directed. 15 Taking down chowkhats or frames not exceeding 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed. 16 Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed. 17 Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed. 18 Taking up or down 15 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed. 19 Taking up or down 20 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed. 20 Taking down eaves, gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed. 21 Taking out of solid/ semi solid sludge from existing manholes of any size and any depth and burrying the entire sludge/ sludge water into excavated pit of adequate size including excavation and covering with earth or disposing off into covered vehicles outside the peripherry of defence land to a distance exceeding 1 Km including taking off RCC/ iron manholes covers and refixing the same after clearing complete all as specified and as directed. 22 Taking up or down CI/ PVC pipes (including all fittings), with spigot and socket ends and lead joints including burning out joints and removing lead of 100/75 mm dia pipe complete all as specified and as directed. 23 Excavation in trenches not exceeding 1.5m wide but not exceeding 1.5m in depth, for foundation, etc, or for shafts, wells cesspits, manholes, pier holes, etc not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in any type soil complete all as specified and as directed. 24 Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed. 25 Removal of surplus excavated soil to a distance exceeding 250 m and not exceeding 500m and deposited where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. 26 Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. 27 Brick work with sub class B bricks straight or curved on plan to any radius in half brick thick wall in cement mortar (1:4) complete all as specified and as directed. 28 Rendering 15 mm thick in cement mortar (1:6) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. 29 Rendering 15mm thick on fair faces of brick/ concrete surfaces built in cement mortar (1:4), finished even and smooth without using extra cement complete all as specified and as directed. 30 Rendering 5 mm thick on ceiling surfaces in cement mortar (1:3) finished even and smooth without using extra cement complete all as specified and as directed. 31 PCC (1:3:6) type C-0 (using 12.5 mm graded crushed stone aggregate) as in back filling, bed block for hold fast etc complete all as specified and as directed. 32 Providing precast cement concrete in cover slab (for manhole) type B-1 (1:2:4) (using 20mm graded crushed stone aggregate) set in cement mortar (1:4) complete all as specified and as directed. 33 Providing 75 mm thick plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as sub base floor complete all as specified and as directed. 34 PCC (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) as in back filling, bed block for hold fast, coping, benching on corner of joints etc complete all as specified and as directed. 35 75mm thick cement concrete (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in floor/ plinth protection laid in suitable panels finished even and fair all as specified. 6mm joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 grade and three parts of sand (all by weight) complete all as specified and as directed. 36 Cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in surface channels complete all as specified and as directed. 37 Providing cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. 38 Concrete bed to 150 mm bore pipe (1:4:8) in type D-2 (using 40mm graded crushed stone aggregate) including haunching against the sides of pipe complete all as specified and as directed. 39 RCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in lintel band etc complete all as specified and as directed. 40 RCC (nominal mix) (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. 41 Formwork to flat soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished complete all as specified and as directed. 42 Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified and as directed. 43 Structural steel work as in roof trusses (framed), post, trusses, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections or MS tube pipe) including distance pieces, cleats etc Fe-410W (Gde E-250) quality A including shop coat of primer complete all as specified and as directed. 44 Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St.- 240 including shop coat of primer complete all as specified and as directed. 45 Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment as in gusset plate, base plate etc complete all as specified and as directed. 46 TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns and binding with and including mild steel wire annealed not less than 0.9 mm dia conformung TMT bars complete all as specified and as directed. 47 Description all as per Ser item No 46.00 here-in-before but 5 mm dia and over upto and including 10 mm dia in stirrups dia complete all as specified and as directed. 48 Mild steel framed works such as grills, framed guard bars, etc and similar work as in cooler stands etc. conforming to Fe 290 Gde E 165 complete all as specified and as directed. 49 Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPs as in roof covering fixed with self tapping screws or L-type or J-type or cranked hook bolts complete all as specified and as directed. 50 Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPs as in ridge of roof fixed with self tapping screws or L-type or J-type or cranked hook bolts complete all as specified and as directed. 51 Galvanised mild steel wire cloth 0.56 mm nominal dia or wire and average width of aperture 1.0 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and as directed. 52 3mm thick sheet glass, ordinary quality glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. 53 Description all as per Ser item No. 52.00 here-in-before but figured glass, pin head type complete all as specified and as directed. 54 Supply and fixing in repair fancy type decorative pattern with selected quality glass 5.5mm thick bevelled edge fixed on wall with 4 Nos 15mm dia stainless steel mirror button stud complete all as specified and as directed. 55 35 mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned complete all as specified and as directed. 56 35mm thick second class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part - I, Section 8, clause 8.20(a) complete all as specified and as directed. 57 Pressed steel frames (factory made) made out of 1.25 mm thick black mild steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete size of frame 105 x 60mm including bottom of each chowkhat to be welded with 2 Nos 25 x 25 x 3mm thick flat iron projecting 10 cm on either side complete all as specified and as directed. 58 Description all as per Ser item No. 57.00 here-in-before but size of frame 125 x 60mm for fixing of two shutters complete all as specified and as directed. 59 Box type steel windows/ Ventilator (factory made) outer frame made out ERW tube P section 65 x 45 x 25 mm and shutter of ERW tube P section 50mm x 35mm x 20mm openable (double shutter) with glazed shutter on external side and gauzed shutter on internal side including steel pintel hinges steel handle 100 mm long mild steel tower bolt 02 nos on each shutter stopper of Z section and its locking arrangement and mild steel hook and eyes suitable for fixing cooler/ AC window complete all as specified and shown on drawings No CEPZTD-324/07 Sh 1/3 to 3/3 and as directed.Notes: - The quoted rates shall also include: -(i) One shop coat of zinc chromate primer on all exposed surface and one coat of tar on the ends of steel surface in contact with bricks/ concrete surface.(ii) 4 nos MS steel lugs made of 20 x 5 mm iron flat 200 mm long.(iii) 10 mm Sq Bar grill/ guard bar design as per drawing.(iv) PCC block for embedding lugs.(v) Two coats of synthetic enamel paint.(vi) Galvanised mild steel wire cloth 0.56 mm nominal dia or wire and average width of aperture 1.0 mm and fixed with tinned tacks or galvanised wire staple. 60 Factory made solid PVC moulded door frame of size 50 x 100mm with wood free EPS and 2mm thick moulded PVC sheet alround supplying and fixing in wall at site as per manufacturers specification complete all as specified and as directed. 61 Factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing complete all as specified and as directed. 62 Suspended false ceiling system using E grid suspended ceiling grid system. The size of grid shall be 600 x 600mm with GI frame work, main runner 39 x 24mm, cross tee 29 x 24mm and wall angle 22.2 x 22.2 mm using 4mm thick high pressure stream cured non primered classic/ designer variant E-Board ISI Marked IS No 14862-2000. Fibre cement E Board to be placed in the gird of E grid suspended ceiling grid system duly suspended by 4mm dia GI bar hangers from the purlins of the roof with butterfly clips complete all as specified and as directed. 63 Aluminium handles D type anodised 150 mm long ISI marked complete all as specified and as directed. 64 Aluminium handles D type anodised 125 mm long ISI marked complete all as specified and as directed. 65 Supply and fixing 200 mm long aluminium anodised barrel tower bolt of extruded section ISI marked complete all as specified and as directed. 66 150 mm long aluminium anodised barrel tower bolt of extruded section ISI marked complete all as specified and as directed. 67 300 mm long dia 12 mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed. 68 Mild steel enamelled helical door spring 150 mm (ISI Marked) size including roller and roller plate, fixed to wooden/ steel frames by any means as required complete all as specified and as directed by Engineer-in-Charge. 69 Floor door stopper of aluminium alloy body and tongue 140 mm anodised with hard drawn steel spring fixed in floor complete all as specified and as directed. 70 100 mm size butt hinges medium weight stainless steel cold rolled mild steel complete all as specified and as directed. 71 Preparation of new surface and applying two coats of oil bound distemper new plaster surface over 1 mm thick putty complete all as specified and as directed. 72 Complete removal of existing surface and preparation of old surface and applying two coats of oil bound distemper over 1 mm thick putty complete all as specified and as directed. 73 Preparation of new surface and applying two coats of exterior emulsion/ weather proof paint over a coat of primer over and including 1mm thick putty on plastered surface complete all as specified and as directed. 74 Complete removal of existing surface and preparation of old surface and applying two coats of exterior emulsion/ weather proof paint over a coat of primer over and including 1mm thick putty on plastered surface complete all as specified and as directed. 75 Preparing surface of new wood and wood based material of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. 76 Preparing surface of new steel material of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. 77 Preparation of surface and applying two coats of white wash over new plaster surface of wall complete all as specified and as directed. 78 Preparation of new surfaces of ceiling and applying three coats of white wash to ceiling complete all as specified and as directed. 79 Preparation of old plaster or painted surfaces of ceiling and applying two coats of white wash complete all as specified and as directed. 80 Preparation of newly plastered surface of any description and applying two coats of cement based paint over a coat of primer complete all as specified and as directed. 81 Preparation of old plastered surfaces and applying two coats of cement based paint up to 12 mtr height complete all as specified and as directed. 82 Non skid tiles coloured exceeding 0.06 Sqm and not exceeding 0.11 Sqm, 6-7mm thick of any colour pattern and 1st quality as approved by GE in floor set and fixed with 3-4 mm spacer set and jointed over neat 5-6 mm thick polymer modified tile adhesive of appropriate grade as per manufacturer instruction and provided with 3-4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed. 83 Coloured glazed ceramic tiles glossy finish of size 450 x 300 x 5-6mm thick in dado’s/ skirting etc (1st quality) set and fixed with 3-4 mm spacer set and jointed over neat 5-6 mm thick polymer modified tile adhesive of appropriate grade as per manufacturer instruction and provided with 3-4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed. 84 Material and labour for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite including taking down old complete all as specified and as directed. 85 Providing edge moulding to 18-20mm thick granite stone of counters vanities etc including machine polishing to edge to give high gloss finish etc. complete all as specified and as directed. 86 Machine cut kota stone slab flooring 18-20mm thick as in floor to match the shade of the slab including 20mm screed bed in cement mortar (1:6) including rubbing, polishing complete all as specified and as directed. 87 Machine cut kota stone slab flooring 18-20mm thick as in riser in step, skirting/ dado to match the shade of the slab including rubbing and polishing over and including 10mm rendering in cement mortar (1:4) complete all as specified and as directed. 88 Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster (1:4) (1 cement : 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster (1 : ½ : 2) (1 cement : ½ coarse sand : 2 stone chipping) 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and as directed. 89 Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design and pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness and size/ shape, made by table vibratory method using PU mould, laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. 90 Supply and fixing in repair drapery curtain rod of metallic 20mm dia covered with PVC coating including MS bracket, end ball, rounded block (coated with brown/ cherry/ golden colour) of approved pattern and shade fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screws complete all as specified and as directed. 91 Taking down existing sunken treatment and cleaning sunken surface by washing and rubbing etc. and removing the material retrieved to a distance not exceeding 500 m where directed. Material and labour for providing water proofing treatment to sunken floors all as given below: -(a) Making fillet of size 25mm x 25mm at corner of slab and wall with polymer modified cementitious (PMC) mortar consisting of one part of tapecreteP-151, two parts of cement and 6 parts of fine sand by weight.(b) Sealing of joints of pipe with epoxy putty CICO POXY LC or epoxy mortar CICO POXY 2125.(c) Cleaning the concrete surface by brushing and watering and applying a coat of tapecrete P-151 Acrylic Polymer Modified cementitious slurry consisting of one part of TAPECRETE P-151 and two parts of cement by weight. The coating shall be carried out upto 300mm above FFL and shall be allowed to dry for 4-6 hours.(d) Appying a coat of TAPECRETE brush topping 1.5mm thick consisting of one part of TAPECRETE P-151, two parts of cement and two parts of silica sand by weight and cured to 2 days.(e) Applying 15mm thick plaster in cement mortar (1:4) mixed with CICO super @ 100ml per 50 Kg cement on treated surface.(f) Material and labour cement concrete type E-2 (1:5:10) as in filling of sunken floor.Note: - Ponding test should be performed for 48 hours as per directions of Engineer-in-Charge. 92 Supply only liquid water proofing compound complete all as specified and as directed. 93 15 mm dia galvanized pipes medium grade with all fittings and fixed complete wall and ceiling or laid in floors complete all as specified and as directed. 94 20 mm dia galvanized pipes medium grade with all fittings and fixed complete wall and ceiling or laid in floors complete all as specified and as directed. 95 1000 litre capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layers hoisted and fixed in position and including dismantling of water tank complete all as specified and as directed. 96 Vitreous china squatting pan Orissa pattern, size 580 x 440 mm white, with integral foot rest and P or S trap and connection to flushing pipe, anti-syphonage pipe in repair complete including provision of cement concrete bedding complete all specified in SSR part - I and all as directed. 97 Vitreous china white under counter wash basins (595 x 420 x 200 mm) oval shape, including waste pipe, brackets and connecting pipe fixed in repair complete all as specified and as directed. 98 Vitreous china urinals, flat back size of 465 x 355 x 265 mm white with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe, brackets and chromium plated waste coupling including urinal spreader in repair complete all as specified and as directed. 99 Vitreous China urinals, half stall l type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) in repair complete all as specified and as directed. 100 15 mm bore sawn neck pillar cock, cast copper alloy, chromium plated with angular knob fixed to 15mm dia MS pipe in repair complete with all fittings all as specified and as directed. 101 PVC valveless, symphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets in repair complete all as specified and as directed. 102 Low density PVC connections commercial quality 15mm bore with PTMT nuts of length 600 mm in repair complete all as specified and as directed. 103 Low density PVC waste pipe 32 mm bore for flushing cistern in repair complete all as specified and as directed. 104 15 mm bore bib taps long nose/ long body, cast copper alloy chromium plated fancy type with capstan head handle screwed down,screwed for brass, weight not less than 450 gms ferrule and fixed in repair complete all as specified and as directed. 105 Bib taps, fancy type chromium plated (Short body) with crutch or butterfly handle, screwed down, screwed for iron pipe of 15mm dia bore including necessary fittings in repair complete all as specified and as directed. 106 15 mm bore angle valves, cast copper alloy chromium plated fancy type, half turn, screwed down, high pressure, with crutch or butterfly handle, weight not less than 450 gms screwed both ends for iron pipe or for unions in repair complete all as specified and as directed. 107 15 mm bore brass stop cock, cast copper alloy chromium plated with long shank and cup (concealed type), high pressure, with capstan head handle, weight not less than 450 gms screwed both ends for iron pipe or for unions in repair complete all as specified and as directed. 108 20 mm dia gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe in repair complete all as specified and as directed. 109 Shower rose brass chromium plated with swivel joint of size 125 mm cast copper alloy chromium plated fancy type withchromium plated neck 9 long made to shape, weight not less than 350 gms in repair complete all as specified and as directed. 110 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, bends, Tees complete fixed to walls at any height complete all as specified and as directed. 111 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, bends, Tees complete laid in trenches or in floors complete all as specified and as directed. 112 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, bends, Tees complete fixed to walls at any height complete all as specified and as directed. 113 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, bends, Tees complete laid in trenches or in floors complete all as specified and as directed. 114 PVC (SWR) bends 110 mm radius complete all as specified and as directed. 115 110 mm PVC (SWR) junction single (T) equal/ Unequal complete all as specified and as directed. 116 PVC (SWR) bends/ shoes any radius of 75 mm dia complete all as specified and as directed. 117 PVC (SWR) bends any radius provided with access door of 110mm dia complete all as specified and as directed. 118 Description all as per Ser item No 117.00 here-in-before but 75 mm dia complete all as specified and as directed. 119 PVC (SWR) vent cowl of radius of 75 mm dia complete all as specified and as directed. 120 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concerete (1:2:4) type B-1in repair complete all as specified and as directed. 121 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight - 210 gms) in repair complete all as specified and as directed. 122 Brass chromium plated towel rail 20 mm dia D type 60 cm long between flanges in repair complete all as specified and as directed. 123 125 mm dia steel grating with or without hole in repair complete all as specified and as directed. 124 Mild steel peg set of six power coated as approved by GE in repair complete all as specified and as directed. 125 150 mm thick RCC pipes class NP-2 laid and jointed complete with collars as in trenches complete all as specified and as directed. 126 Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement complete all as specified and as directed. 127 Soap dish steel chromium plated 100 mm size complete all as specified and as directed. 128 75 mm PVC (SWR) junction single (T) equal/ unequal complete all as specified and as directed. 129 E/M Portion: -Taking down old unserviceable copper/ aluminium point wiring concealed/ batten (light, fan, socket or power) complete, including fixtures and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board PVC/ iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. 130 Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 6.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length including taking down old wiring complete all as specified and as directed.Notes: - (i) Wiring shall be done in proper colour coding.(ii) Rates are inclusive of cutting/ chases with suitable PCC works and making good to disturbed surfaces. 131 Point wiring for one light/ fan/ call bell point controlled by one 5 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into new concealed PVC rigid conduit with modular CI/ pressed steel sunken/ terminal boxes of required size including modular cover plate with frame for mounting switches, sockets, fan regulators etc complete all as specified and as directed.Notes: - (i) Wiring shall be done in proper colour coding.(ii) Rates are inclusive of cutting/ chases with suitable PCC works and making good to disturbed surfaces. 132 Description all as per Ser item No 131.00 here-in-before but for multi 5 pin 5 amp socket outlet on same board ISI marked complete all as specified and as directed. 133 Description all as per Ser item No 131.00 here-in-before but for multi 5 pin socket outlet 5 amp socketon independent board ISI marked complete all as specified and as directed. 134 Description all as per Ser item No 131.00 here-in-before but for multi 6 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 Sqmm copper conductor multistrand cable PVC insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/25 mm dia and unsheathed copper conductor multistranded cable 2.5 Sqmm as earth wire FRLS PVC insulated in green color complete all as specified and as directed by Engineer-in-Charge. 135 Modular socket, 6A - 5 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed. 136 Modular switch 1 module 6A, 1 module, 240 volts ISI marked complete all as specified and as directed. 137 Ceiling rose, 2/3 Pin/ PVC/ polycarbonate isolated body ISI marked complete all as specified and as directed. 138 Modular switch 1 way 16A, 1 module, 240 volts ISI marked complete all as specified and as directed. 139 Modular socket 6A/16A - 6 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed. 140 LED lights fitting 1 x 20W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.9, 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 141 Distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge.Note: - Distribution board and MCBs should be of same make. 142 MCB SPN 40 to 63 Amp rating 240V, 10 KA B curve type, in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed. 143 MCB of single poles and current carrying capacity 5 to 32 Amp,240V, 10 KA B curvecomplete all as specified and as directed. 144 Earthing complete with galvanised mild steel earth plate electrode of size600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed. 145 Fan step regulator, 120W - 2 module 240 volts ISI marked complete all as specified and as directed. 146 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP- 65/66 protection complete all as specified and as directed. 147 XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 25 Sqmm 2 core laid in LT pole overhead line to SPN distribution board box with connected accessories including taking out old unsv complete all as specified and as directed. 148 Switch piano, flush type single pole one way 5 Amp, 240 volts complete all as specified and as directed. 149 Socket outlet 2 in 1, 3 pin, 5 A complete all as specified and as directed. 150 Switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 Volts complete all as specified and as directed. 151 LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge. 152 Distribution board, double door for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge.Note: - Distribution board and MCBs should be of same make.