Tender For Provision Of Certain Electrical Minor Works And Revenue Major Works At Afa Hyderabad;  1 S&F Testing and commissioning of pump set of capacity 3 HP , electric driven 415 V, 3 phase for suction sweeping of Acy swimming pool complete all as specified and as directed.  2 Supply and fixing of Submersible cable, PVC insulated, PVC sheathed 1100 volts grade, multistranded copper conductor flat, 3 core 6 Sqmm complete all as specified and as directed.  3 Supply and fix ,connect and test DOL starter type MK-1 with sheet steel enclosures, 3 phase, 415 volts, 50 Hz suitable for motor out put of 5 HP complete all as specified and as directed.  4 Supply and fixing suction Hose 40 mm dia bore PVC heavy duty with clamps etc. complete all as specified and as directed.  5 s & F of suction sweeper assembly of width 36  with wire brush and 04 nos of fibre wheels for cleaning of under water dust/dirt etccomplete all as specified and as directed.  6 M&L for trolley made of mild steel with 04 Nos rubber wheels for mounting of suction sweeping pump set of capacity 3 HP with necessary welding, nuts,bolts complete all as specified and as directed.  7 M&L for Trial bore hole of 165 mm dia & further Development of the Trial Bore into Tube Well in any kind of Soil/Strata/Rocky surfaces etc. by Reaming from 165 mm dia to 203 mm dia & 254 mm dia upto the weathered portion upto 200.0 mtr depth below ground level by deploying suitable Down The Hole (DTH) Rig all as per CGWB Recommendation Report complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge.  8 Supply, assembling, jointing, lowering and fixing in position 150 mm dia (internal), PVC Medium Well (CM) Casing Pipe, 8 Kgf/Cm2, Screwed & Socketed type, confirming to IS 12818 including necessary cleaning internally & externally suitable for drinking water purpose in different depths with & including Bail Plug & Well Cap & testing complete all as specified & as directed & to the entire satisfaction of Engr-In-Charge. MAKE: SUPREME/ASHIRVAD/FINOLEX/ASTRAL  9 Supply, assembling, jointing, lowering and fixing in position 150 mm dia (internal), PVC Medium Well (CM) Slotted/Screen Pipe, 8 Kgf/Cm2, Screwed & Socketed type, confirming to IS 12818 including necessary cleaning internally & externally suitable for drinking water purpose in different depths incl testing complete all as specified & as directed & to the entire satisfaction of Engr-In-Charge. MAKE: SUPREME/ASHIRVAD/FINOLEX/ASTRAL  10 Supply, assembling, jointing, lowering and fixing in position Column Pipe made out of 50 mm bore heavy duty GI pipe screwed & socketed type incl testing complete all as specified and as directed & to the entire satisfaction of the Engr-In-Charge. MAKE : Tata/Jindal/Prakash.  11 NOTE for Item Nos above : 1) The cost of mobilisation of Rig Set with Tools, Plants, Machinery, Manpower etc. incl use and waste of all necessary appliances and materials including leveling, dismantling after taking out the same after completion of the tube well assy including testing to entire satsfaction of the Engr-in-Charge is deemed to be included in the unit quoted rates by the Tenderer. No extra claim whatsoever shall be entertained. 2) The Down The Hole (DTH) Rig should be registered with Central Ground Water Authority & certificate in support of the same to be submitted to the Engr-In-Charge by the Contr. 3) PVC Casing & Slotted Pipes shall be measured & paid separately. 4) Cost of supply and packing required quantity of Pea Gravel of size 3 to 5 mm as per IS of natural shape brought directly from river bed and packing around the casing pipe to entire depth upto ground level around the Casing Pipe & Slotted Pipe (surrounding the Borewell assy) is deemed to be included in the unit quoted rates. 5) Any item/job missed out in the item description/specification but technically required for successful completion of the work/job is deemed to be included in the unit quoted rates. 6) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm. 7) After complete drilling of the borehole electric logging to be carried out for exact selection of strata & the same shall be measured & paid separately under relevant items. 8) In case the results of the borehole/strata are found un-satisfactory & the tubewell is not likely to yield the specified quantity of water, the site shall be abandoned & the contr shall be paid for the boring part only.  12 S&F Mild Steel Clamp for holding 50 mm bore column pipe bent to shape as required, drilled holes including bolts, nuts & washers complete all as specified and as directed & to the entire satisfaction of the Engr-In-Charge.  13 Supply and fixing 02 x Runs of PVC insulated, PVC sheathed, 3 core flat copper, flexible submersible cable of size 4 Sqmm, 1100 Volts grade including jointing with M-seal and connecting from Pump Set to Starter with suitable sized thimbles and lugs with & including suitable fixing arrangements alongwith Column Pipe at suitable intervals incl testing complete all as specified and as directed & to the entire satisfaction of the Engr-In-Charge. Make : HAVELLS/FINOLEX/POLYCAB/KEI  14 M&L for Electric logging of bore for precise delineation of granular zones & also the quality of ground water including report interpretation using suitable equipments before lowering of Pipes and Strainers from Auth/Reputed agency and Report shall be submitted to GE for approval.  15 M&L for Development of the Tube well with Air Compressor of suitable capacity till sand/mud free water of potable quality is obtained and to achieve maximum discharging capacity complete all as specified and as directed & to the entire satisfaction of the Engr-In-Charge.  16 M&L for Yield testing of the Tube Well by suitable method for achieving minimum discharging capacity for at least continuous 8 hours uniterrupted run per day for three continuous days complete all as specified and as directed & to the entire satisfaction of the Engr-In-Charge. NOTE for Item Nos above : 1) The cost of mobilisation of Air Compressor/V-Notch incl any other item/equipment etc. with Tools, Plants, Machinery, Manpower etc. incl use and waste of all necessary appliances and materials including generation of Reports duly signed by all concerned after completion of the Testing is deemed to be included in the unit quoted rates. 2) Electric Logging/Development/Yield test of bore well shall be carried out in the presence of rep of Accepting Officer & Test Reports to be submitted in Original duly signed by all concerned to the Engr-In-Charge.  17 Supply only strata sample box with glass cover 3mm thick having internal dimension 1000x600x100mm made out of 20mm thick wrought Ist class hard wood shisham with hinges, hasp and staple including polishing complete with samples at various depthevery 2 mtr interval met in boring including strata chart in duplicate complete all as specified and as directed & to the entire satisfaction of the Engr-In-Charge.  18 M&L for sanitary sealing of tube well with PCC (1:2:4) type B1 of suitable size using 20 mm graded aggregate complete all as specified and as directed & to the entire satisfaction of the Engr-In-Charge.  19 M&L for Testing of water for all parameters i.e. Physical, Chemical and Bacteriological aspects all as per IS : 10500 incl latest amendments from any Govt approved/recognised/NABL accredited laboratory & submission of reports in Original complete all as specified and as directed & to the entire satisfaction of the Engr-In-Charge.  20 Supply, Install, Commissioning & Testing of Submersible Pumping Set complete with Electric Motor not less than 7.5 HP suitable for 03 phase, 200 to 400Volts, 50 Hz, B Class Insulation, Water Cooled, IP-68 Protection Level, 20 Stage, 50 mm Outlet Size having discharge capacity of 200 LPM at a head of 130 mtr complete all as specified & as directed. Make : KIRLOSKAR/KSB/CROMPTON (1W+1S)  21 Excavation in trenches mechanical or other means in any type of soil not exc 1.5 mtr wide and not exc 1.5mtr depth for laying of CI/GI Pipe lines, forming bottom surfaces of excavation to re-laid lines/gradient etc complete all as specified.NOTE : 1) The requirement of JCB (if any) for cutting the hard standing/PCC/WBM road surface or during earthwork is deemed to be included in the unit quoted rates. 2) If any damage to any Cable of Air Force/BSNL/MES etc. or to any Pipe lines develops/occurs during execution of the works then the same shall be made good by the Contr to the entire satisfaction of the concerned Dept/Section & the costs of the same is deemed to be included in the unit quoted rates.3) Quoted rate is also deemed to be inclusive of clearing/removing/cutting of vegetation/tree branches/small to medium plantings/bushes etc. so as to facilitate successful completion of the work. No extra/addl payment shall be allowed to the Contr in this regard.4) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm.  22 Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.  23 Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.  24 Supply and laying first class bricks of size 25 x 12.5 x 7.5 cm (+/- 8% tolerance )in trenches for protection of UG Cable complete.  25 Supply, laying, testing & commissioning XLPE LT UG Cable 1100 V grade, heavy duty with PVC insulated stranded Al. conductor served with a inner sheathing of PVC tape armoured with galvanized steel wire or tape & overall PVC sheathed 25 sqmm 4 core nominal X-section incl. all electric connection with suitable size Al. lugs, GI nuts,bolts & washers complete all as specified & as directed to the entire satisfaction of Engr-In-Charge. Make : HAVELLS/FINOLEX/POLYCAB/KEI  26 Supply & laying GI PIPE ( Light grade), 40 mm bore under road/duct/culvert for protection of UG cable all as specified and as directed. MAKE : Tata/Jindal/Prakash.  27 M&L for galvanised steel water tubing, medium grade, 80 mm bore with all running fittings such as bends, tees, unions, elbows, connecting pieces etc. laid in trenches or on ground/other surface etc. incl testing complete all as specified and to the entire satisfaction of the Eng-in-Charge. MAKE : Tata/Jindal/Prakash.  28 M&L for galvanised steel water tubing, medium grade, 50 mm bore with all running fittings such as bends, tees, unions, elbows, connecting pieces etc. laid in trenches or on ground/other surface etc. incl testing complete all as specified and to the entire satisfaction of the Eng-in-Charge. MAKE : Tata/Jindal/Prakash.  29 Supply, install, commissioning & testing of CI Sluice Valve 80 mm bore, both ends flanged, class PN 1.6, ISI marked conforming to IS 14846:2000 with SS spindle and one number hand wheel including making new flanged joints with rubber gasket, necessary bolts, nuts, washers etc of suitable size incl taking down old unsv one complete all as specified and to the entire satisfaction of the Eng-in-Charge. MAKE : Leader/Kirloskar/Upadhyay/KARTAR  30 Supply, install, testing & commissioning of CI Non-Return (Reflux) Valve 80 mm bore, both end flanged, class PN 1.6, ISI marked conforming to IS 5312 (Part I & II) including making new flanged joints with rubber gasket, necessary bolts, nuts, washers etc of suitable size incl taking down old unsv one complete all as specified and to the entire satisfaction of the Eng-in-Charge. MAKE : Leader/Kirloskar/Upadhyay.  31 S&F Gun metal gate valve 50 mm bore conforming to IS 781 -1984 with iron wheelhead screwed both ends for iron pipe incl testing testing & taking down old unsv one complete all as specified and to the entire satisfaction of the Eng-in-Charge. MAKE : Leader/Tata/Zoloto/Kartar/RMCO  32 Supply, install, testing and commissioning of  Outdoor Cubical type  LT Distribution Control Board of size & dimensions as specified by the GE & Engr-In-Charge, factory fabricated type-tested with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (outer portions) & 2.0 mm thick (inner portions) CRCA sheet duly pre-treated & powder coated, supporting frame made out of 40 x 40 x 6 mm angle iron & MC 100 channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl PCC platform/plinth of suitable size complete all as specified & as directed with & incl the following accessories : (PUMP STARTER PANEL)  33 BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos tinned copper 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized F class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables.INCOMING/OUTGOING/INSTRUMENTATION SYSTEM :(a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 40A - 01 Nos. Make : L&T/ABB/SIEMENS(b) Submersible pump controller in sheet enclosure fully automatic star-delta starter type confirming to IS 13947-4-1 suitable for motor rating upto 10 HP, AC 3 duty, 415 V (Coil Voltage - 250 to 450 V), 50 Hz, 3 Phase, relay range 13-21 A complete with Heavy duty 4 Pole Contactor, Overload Relay, Auto Start switch, 3 Position selector switch for SPP Auto / SPP Manual / Manual, Voltmeter with selector switch, suppressed scale Ammeter, RYB LED indicator Motor ON & Trip LED indicator, TP C curve MCB for short-circuit protection - 02 Nos. (1W+1S) Make : L&T/BCH/HAVELLS or techno-commercially equivalent.(c) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.(d) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos.NOTE : 1) Design / Drawing / BOM of the Panel Board showing the dimensions is to be obtained from Manufacturer / Supplier & is to be got approved from the Engr-In-Charge/GE before placing final order to the manufacturer.2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.  34 M&L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed by the Engr-in-Charge.  35 M & L for sub-main wiring alongwith earth wire of size (4 x 4.0) sq. mm + (1 x 4.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) of minimum size 25 mm dia with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed to the entire satisfaction of Engr-In-Charge. Make of cable : Havells/Polycab/Finolex/KEI. Make of Conduit : Polycab/Finolex/Modi/Precision. NOTE : 1) Four runs of PVC wire, One run of Earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Cost of Modular metal flush boxes (if any for junction inspection) is deemed to be included in the unit quoted rates. 3) Cutting chases (if any) & making good the disturbed surfaces is deemed to be included in the unit quoted rates. 4) Cost of PVC clamps/saddles of appropriate sizes with fixing screws for fixing on walls &/or PVC cable ties etc. for fixing on steel support members (if any) is deemed to be included in the unit quoted rates. 5) The wiring shall be done with proper colour coding using Red, Yellow & Blue Coloured wires only for Phase, Black for Neutral & Green for Earth Wire.  36 M & L for surface sub-main wiring alongwith earth wire of size (2 x 4.0) sq. mm + (1 x 4.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed. Make of cable : Havells/Polycab/Finolex. Make of Conduit : Polycab/Finolex/Modi/Precision.  37 Description all as per Item above here in before but of size (2 x 1.5) sq. mm + (1 x 1.5) sq. mm earth wire complete all as specified & as directed.NOTE for Item Nos above : 1) Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Modular metal flush boxes (if req) shall be measured & paid separately. 3) Cutting chases & making good the disturbed surfaces (if any) is deemed to be included in the unit quoted rates. 4) Cost of PVC clamps with fixing screws for fixing on walls &/or PVC cable ties etc. for fixing on steel support members (if any) is deemed to be included in the unit quoted rates. 5) The wiring shall be done with proper colour coding using Red, Yellow & Blue Coloured wires only for Phase, Black for Neutral & Green for Earth Wire.  38 S & F Switch Box made out of 8 Module PVC Surface Mounting Box duly incorporating 03 x Modular shuttered socket outlet 3 Pin, 6 Amp, 2 Module, 240 volts, ISI marked, 01 x Modular switch, one way, 6 Amp, 1 Module, 240 volt with Indicator & 01 x Indicator with pre-wired internal connections incl testing suitable for multiple operation of PC/Desktop etc complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge. Cat No : ACVKSWW063 & Cat No : ACVSXXW061 of Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab.  39 S & F Modular switch, one way, 6 Amp, 1 Module, 240 volt complete all as specified and as directed. Cat No : ACVSXXW061, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab  40 S & F Modular shuttered socket outlet 3 Pin, 6 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No : ACVKSWW063, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab  41 S & F 6A Plugtop with Indicator, 3 Pin, 240 volts, ISI marked complete all as specified and as directed. Cat No : AHLGWXW063 of make Havells or techno-commercially equiv In Legrand/Anchor Roma/PolycabNote for Item above : 1) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned. 2) The Switch Boxes are to be fixed on inner side of the Computer Tables with proper insulation & the cost of the fixing arrangements of the Switch Box to the Computer Table as per requirement of the User/MES is deemed to be included in the Unit quoted rates. 3) Extension of connection of the Switch Boxes from nearest power supply source on walls shall be measured & paid separately under relevant items. 4) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. 5) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm.  42 Supply & Fixingand surface modular PVC boxsuitable for fixing switches/sockets of 3 modules all as directed. Make : VERONA (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab  43 Supply & Fixingmodular cover platesuitable for fixing switches/sockets of 3 modules all as directed. Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/PolycabNOTE for Item above : The make/model of modular metal flush boxes & modular cover plates shall be same as that of modular switches & sockets. 2) Cost of taking down old unsv one & making good disturbed surfaces is deemed to be included in the unit quoted rates.  44 S & F TPN DB, 4 Way, IP43, IK09, Metal double door type 415 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.  45 S & F SPN DB, 8 Way, IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.  46 S&F MCB, TPN, C-Series 415 Volts of capacity 40-100 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. (1W+1S) Make-L&T/LEGRAND/SIEMENS/ABB.  47 S&F MCB, SPN, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.  48 S&F MCB, SP, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.NOTE for Item above : Make of MCBs shall be same as the make of MCB DBs.  49 M & L for surface sub-main wiring alongwith earth wire of size (2 x 2.5) sq. mm + (1 x 2.5) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed. Make of cable : Havells/Polycab/Finolex. Make of Conduit : Polycab/Finolex/Modi/Precision. NOTE : 1) Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Modular metal flush boxes (if req) shall be measured & paid separately. 3) Cutting chases & making good the disturbed surfaces (if any) is deemed to be included in the unit quoted rates. 4) Cost of PVC clamps with fixing screws for fixing on walls &/or PVC cable ties etc. for fixing on steel support members (if any) is deemed to be included in the unit quoted rates.5) The wiring shall be done with proper colour coding using Red, Yellow & Blue Coloured wires only for Phase, Black for Neutral & Green for Earth Wire.  50 S & F Modular switch, one way, 16 Amp, 1 Module, 240 volt with Indicator complete all as specified and as directed. Cat No : ACVSXXW161, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab  51 S & F Modular shuttered socket outlet 3 Pin, 6/16 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No : ACVKCWW163, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/PolycabNote for Item Nos above : Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned.  52 Supply & Fixingand concealing modular metal flush boxsuitable for fixing switches/sockets of 3 modules all as directed. Make : VERONA (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab  53 Supply & Fixingmodular cover platesuitable for fixing switches/sockets of 3 modules all as directed. Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab  54 S & F SPN DB, 8 Way, IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.  55 S&F MCB, SPN, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.  56 S&F MCB, SP, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA.Make-L&T/LEGRAND/SIEMENS/ABB.  57 Supply and laying in trenches/through pipes or bare in road crossings/ paths /drains /ducts /floors /along poles/ walls/ ceilings/ equipments etc. Cable Under ground, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade ofcross sectional area, 3.5 Core 50 Sqmm incl connecting with suitable glands, lugs etc all as specified and directed by the Engr-in-Charge. Make: Havells/Finolex/Polycab/Gloster  58 Supply and laying in trenches/through pipes or bare in road crossings/ paths /drains /ducts /floors /along poles/ walls/ ceilings/ equipments etc. Cable Under ground, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade ofcross sectional area, 4.0 Core 10 Sqmm incl connecting with suitable glands, lugs etc all as specified and directed by the Engr-in-Charge. Make: Havells/Finolex/Polycab/Gloster  59 M&L for cutting the existing hardstanding/PCC/WBM road/rocky surfaces at a depth of not less than 75 cm & 30 cm in width for passing of LT cables through GI/DWC pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed.  60 Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth forlaying of pipe and getting out in hard dense soil complete.NOTE for Item No 11 & 12: 1) The requirement of JCB (if any) for cutting the hard standing/PCC/WBM road surface or during earthwork is deemed to be included in the unit quoted rates. 2) If any damage to any Cable of Air Force/BSNL/MES etc. or to any Pipe lines develops/occurs during execution of the works then the same shall be made good by the Contr to the entire satisfaction of the concerned Dept/Section & the costs of the same is deemed to be included in the unit quoted rates.3) Quoted rate is also deemed to be inclusive of clearing/removing/cutting of vegetation/tree branches/small to medium plantings/bushes etc. so as to facilitate successful completion of the work. No extra/addl payment shall be allowed to the Contr in this regard.4) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm.5) Quoted rate is deemed to be inclusive of S&F of PVC Saddles/Clamps incl connecting fixing arrangements wherever cables are to be laid/fixed on walls/floors etc. complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge.  61 M&L for HDPE DWC (Double Wall Corrugated) Pipe ofrating 450 N, ISI marked with Min OD 77/75 mm & Min ID 63 mm, Orange colour for LT UG Cable protection with & including Couplers with rubber rings & RR & NFP properties/features confirming to IS 16205 Part 24:2018 & IEC 61386 Part 24:2007 complete all as specified & as directed by the Engr-In-Charge.  62 S&F Tripple Pole & Neutral sheet metal enclosure with a three pin & earth plug & socket with one Tripple pole MCB, C Curve, 10 KA, 415 V, 32A fixed flush to wall complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge.NOTE : 1) Make of TPN Metal Plug & Socket & MCBs shall be the same. 2) Cost of making good the disturbed surfaces is deemed to be included in the unit quoted rates.  63 Supply and fix hose box made of 18 gauge MS Sheet with minimum dimensions 800mm x 600mm x 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet with two coats of fire red paint outside and brilliant white inside for keeping 2 Nos hose pipe of length 30 meter each, branch pipe, nozzle, coupling etc. with locking arrangement (common key lock) complete all as specified & directed & to the entire satisfaction of the Engr-In-Charge. Make : MINIMAX/NEWAGE/SAFEX/SAFEGUARD  64 Supply and fix 63 mm dia RRL Hose type A 30 meter long hose duly banded with SS wire, ISI Marked, conforming to IS 636 complete with male and female coupling & branch pipe adapter conforming to IS 903 incl jointing & testing complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. Make : MINIMAX/NEWAGE/SAFEX/SAFEGUARD NOTEfor Item above : 1) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items before placing order to the Manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. 3) Necessary Test/Guarantee/Warrantee certificates to be submitted in original to the Engr-in-Charge. 4) Cost of transportation of any old/existing hosebox/hose etc. from site of work to MES storeyard is deemed to be included in the unit quoted rates. 5) Original Purchase Vouchers & Test Certificates to be submitted to the Engr-In-Charge.  65 Taking down chowkats or steel window / door frames with shutters (without taking off shutters from frames) exc 1.5 Sqm but not exc 4 Sqm each complete all as specified and as directed.  66 Demolition ofreinforced cement concrete of any description and in any position not otherwise specifically provided for RCC Chajjas/Roof projections etc complete all as specified and as directed. (Reinforcement cut as required to facilitate demolition)  67 Demolition of Brick/stone masonry built in cement mortar of any description, etc complete all as specified and as directed  68 Dismantling floor hearth or existing wall tiling incl cement mortar bedding (but not backing) including removal of debris from the site, etc complete all as specified and as directed  69 Demolition of stone slabs, granite and tiles of any description or thickness in floors set in cement mortor etc completeall as specified  70 Taking down cement plaster on brick or stone walls,etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed  71 M&L for brick work with sub class `B brick (old size bricks) straight or curved on plan exceeding 6 m mean radius built in CM 1:4, complete all as specifiedand as directed.  72 M & L for rendering 15 mm thick in cement mortar 1:6on fair faces of brick work or concrete surfaces at any height with necessary scaffoldings,finished even smooth withoutusing extra cement etc complete all as specified and as directed  73 M&L for precast Reinforced cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate), as in Wash hand basin platform slabs, etc including necessary form work set in CM 1:4, complete all as specified and as directed.  74 M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90 mm dia complete all as specified and as directed.  75 M&L for Forming jambs, etc. to openings in Cement mortar 1:4 or cement lime mortar 1:2:9,including cutting, toothingand properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified.  76 M&L for Making good under cills or over arches, lintels and bressummers in Cement mortar 1:4 or cement lime mortar 1:2:9. including allpinning when necessary cmplete all as specified.  77 M&Lof 20 mm thick Granite work (table rubbed and polished) black coloured, cooking platform ,window cills/Jambs etc and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc complete all as specified and as directed.  78 M & L of 18 to 20 mm thick Granite work (table rubbed and polished) black coloured,for wall lining (veneering to wall ) 12mm thick in cement mortar (1:3) and pointing withwhite cement (1:2) using marbel dustwith admixture of pigment to match with shade of granite etc complete all as specified and as directed.  79 M & L for Vitrified ceramic tiles any shade / double charged / ultracharged, 10 mm thick (square or rectangular) area of each tiles not less than 0.72 sqmas in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles, complete all as specified and directed.  80 M & L Joint free Glazed coloured ceramic tiles of digital quality in vertical surface450X300X7-8mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and as directed.  81 M & L for rendering 10mm thick in cement mortar 1 : 4 on brick or concrete surfaces to receive as backing of wall tilingetc complete all as specified and as directed.  82 M&L for screed bed or bedding layer of cement mortor 15 mm thick for laying floor finished in CM 1:6,etc complete all as specified and as directed.  83 M & L rounding to edges of stone slabs one edge, in cooking platforms etc complete all as specified and as directed  84 S & F Powder coated aluminium frame (minimum thickness of powder coating 50 micron) for sliding glass cabinets, doors, windows, ventilators, partitions orwith one or more rebates including joining cleat for fixing etc.complete all as specified and directed.  85 S & F 12.00 mm thick toughened glass for shelves in cabinets fixed with necessary rubber gasket, and other necessay aluminium beedings/fittings in aluminium frames, complete all as specified and as directed.  86 S & F 4.00 mm thick toughened glass for sliding glass shutters in cabinets fixed with necessary rubber gasket, rollers and other necessay aluminium beedings/fittings in aluminium frames, complete all as specified and as directed.  87 S&F Powder coated (Thickness not less than 50micron) Aluminium Three Track Sliding windows of Approximate size 2700mm x 1320mm made out of anodised aluminium extruded section Outer Frame with gutter 92x31.75x1.50mm and Shutter section 40x18x1.50mm fully glazed including 5mm thick Tinted glass/ sheet glass, rubber gasket, Aluminium beading, suitable fancy type handles, locking device, rollers and all other required Hardware fittings as per standard Engg. practice, etc complete all as specified and as directed.  88 S&F Powder coated (Thickness not less than 50micron) Aluminium Two Track Sliding windows of Approximate size 1780mm x 1300mm made out of anodised aluminium extruded section Outer Frame with gutter 61.85x31.75x1.50mm and Shutter section 40x18x1.50mm fully glazed including 5mm thick Tinted glass/sheet glass, rubber gasket, Aluminium beading, suitable fancy type handles, locking device, rollers and all other required Hardware fittings as per standard Engg. practice, etc complete all as specified and as directed  89 S&F Powder coated (Thickness not less than 50micron) Aluminium anodised Grill, aperture n exc 75 mm ,size 6mm x 4mm thick, including 1 mm thick channel fixed with steel screws etc complete all as specified and as directed  90 S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, etc complete all as specified and as directed  91 M & L for Second class hardwood Plain fillets in cub boards, shelves, etc Exc 13 & n. exc 25 sq. cm, square, rectangular or triangular in section, clean sawn, secured with mills or brads, etc complete all as specified and as directed  92 M & L 18mm thick Marine plywood of First Grade fixed with screws as in cupboards doors/Shutters, shelves, partitions and in simillar works, etc complete all as specified and as directed  93 M & L 12mm thick Marine plywood of First Grade , fixed with screws as in cupboards, sides of shelves, partitions and in simillar works, etc complete all as specified and as directed  94 M & L for 0.9 mm thick Decorative laminated sheet type 1 of surface finish coloured andpattern as approved and fixed over plywood with approved adhesive etc complete all as specified and as directed  95 M & L for external teak wood lipping, 6mm thick, fixed with nails 19mm wide. etc complete all as specified and as directed  96 S&F Stainless Steel Magnetic Door Catcher of size 50.8 x 25.4 x 25.4mm with suitable plates for wooden cabinet doors or simillar etc all as specified and as directed.  97 S&F Brass Continuous (piano) hinges,width of flap 30mm bright finish or electrogalvanised, etc complete all as specified and as directed  98 S&F of 100mm aluminium anodised Hasp and staple, safty type, with hinge pin including bolt to hinge plate and fixed with screws etc complete all as specified and as directed.  99 S&F 75 mmBrass handles, cast type, polished bright finish etc complete all as specified and as directed.  100 M&L 40 mm High density polyethylene pipes(HDPE) of pressurerating 6 kgf/cm2 laid in trench and fixed in walls .  101 Taking up or down 15mm bore ofpipe steel tubing and connections, including for refixing or removal etc complete all as directed.  102 S&F 15 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls, ceilings or laid in floors etc complete all as specified and as directed.  103 Supply and fix in repairs stainless steel sink of overall size 495mmx420mm bowl size 410mmx330mmx160mm made of stainless steel 1 mm thick for kitchenwith plugs, washers and waste pipe including cast iron cantilever bracketsand connecting to union / pipe complete all as specified and as directed.  104 S&F in repair of Bib taps, CP fancy type with capstan head screwed down, screwed for iron pipe or for brass ferrule andfixed to 15mm bore pipe etc complete all as specified and as directed  105 M&L in repairs of Waste coupling of32 mm dia chromium plated for glazed ware , sinks ,basins with long screwed shanks and fly-nuts etc complete all as specified and as directed.  106 S&F in repairsPVC waste pipe 32 mm bore, 900 mm long etc complete all as specified and as directed.  107 S&F in repairs Grating doom 100mm dia of Stainless hinged or openable type ,fixed with suitable solvent cement .  108 S&F 5mm thick Bevelled edge looking mirror of size 600x450mm, of selected quality, including fixing to walls with catch nuts etc, complete all as specified and as directed.  109 Preparation of newly plastered internal wall surface and applyingtwo coats of distemper oil emulsion over a coat of Alkali resistant priming paint over the coat of 3mm thick wall care putty etc complete all as specified and as directed  110 Complete removal of the existing treatment on ceiling and applying two coats of distemper oil emulsion over a coat of white wash including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.  111 M & L Complete removal of existing treatment and applying two coats of oil bound distemper on walls over a coat of alkali resistant priming paint over the coat of 3 mm thick wall care putty on wall, completed all as specified and directed.  112 Removal of debris (Aggregates) obatained from demolitionincluding loading and unloading to a distance of 5km from the starting point and deposited where directed etc complete all as specified and as directed.  113 M&L for shifting Fixing, Testing and commissioning of old open well Submersible pump set of capacity 7.5 HP, electric driven 415 V. 3 phase from safety bay SWT to SWT near link F complete all as specified and as directed. Note: Complete overhauling of open well submersible pumpset including replacement of bearings and other spare parts if any required is to be carried out before installation at new site. The cost of the same is deemed to be included in the quoted rate  114 Supply and fixing of Submersible cable, PVC insulated, PVC sheathed 1100 volts grade, multistranded copper conductor flat, 3 core 6 Sqmm complete all as specified and as directed.  115 Supplying, installation, testing & commissioning of CPRI approved outdoor cubical type feeder pillar box suitable for 415V 3 phase, 4 wire 50Hz Ac supplysystem fabricated from stainless steel (SS316) totally enclosed,dust weather & vermin proof 3.0mm thick for outer shell and 2mm thick for inner shell having 3phase copper bus bars of rating 250 amps with short circuit withstand capacity of 55MVA for 1 second Bottom base channel of MS section not less than 100mmx50mmx5mm thick entire panel shall have a common aluminium earth bar of size 25mmx5mm at the rear with 2 nos earth stud, with suitable copper busbars from main busbar to switchgears including 1.5sqmm pvc insulated copper control wiring, cable alleys.cable gland plates in two half including tamper proof digital energy meter to measure voltage, current, PF KWh, KVAH KVARH and general construction confirming to IS:8623/93 and mounted on suitable PCC foundation All door should have neaprene rubber gasket and locking arrangement the cabinet shall be comprising with the following accessoriesIncoming:-(a) Four pole MCCB 100 Amp,35 KA-01Metering & Indication(b) Voltmeter selector switch-1 Nos(c) Ammeter selector switch-1Nos (d) CT-200/5AOutgoing:-(e) MCCB 63 Amp 16 KA-1 Nos(f) MCCB 32 10 ΚΑ-02(g) Copper TPN Busbar 250A-1 Set  116 Supply, install, testing and commissioning of LT Panel board outdoor type made out of 3. 15 mm thick CRCA Sheet and MS angie iron frame with weather proof canopy, mounted on PCC pedestal, Cubical type, front and rear side openable. compartment type with hinged door lifting lugs 2 Nos, earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc and passivated nut, bolts, spring and washers and locking arrangement for each compartment, provision of air vent, dust and vermin proof, provision of cable alley with 300 Amps rated Aluminium bus bar for phase and 100 Amps for nuetral having 1100 Volts grade sleaving and internal connection should be provided with aluminium strips of suitable size to accomodate and including the following duly painted with 2 coats powder coating over a coat of anti corrosive red oxide primer should accommodate the following accessories MCCB 63 amps, 415 Volts, 50 Hz, 18 KA (Incoming)-01 Nos Star Delta Starter suitable for 7.5 HP-02 No Make BCH/SeemenSingle phase preventor 02 No Make PowerTech/MinilecDigital type Ammeter 0-100 Amps with CT-01 Nos Digital type Voltmeter 0-500 Volts with in built selector switch-01 NesLED type indication lamps with switches and fuses (RY.B)-01 SetNote:- (1) The rate quoted is inclusive of necessary CTs, Control wiring and instrument fuse holder.  117 Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel stripof wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core  118 Excavation in trenches not exceeding 1.5m wide but exc 1.50 mtr and not exceeding 3.0 mtr in depth in soft/loose soil and getting out for repairs to water mains/valves/valve chamber including forming of bottom surface to required level and gradient complete all as specified and as directed  119 Retuning, filling in trenches including spreading levelling, watering and ramming in layers not exceeding 25 cm complete all as specified and as directed  120 Removing the surplus soil to a distance exceeding 50 metres and not exceeding 250 metre and depositing where directed at a level not exceeding 1.5 metres above the starting point complete all as specified and as directed  121 M&L River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenchesIncluding punned thickness up to 18 cm and consolidation, complete all as directed Note: Punned thickness only will beconsidered for payment  122 Supply and lay common burnt, clay building bricks, sub class B designation over the sand cushioning in cable trenched for protection of cables (LT) complete all as specified and as directed  123 M & L for mild steel framed work for any description including necessary cutting welding jointing and making proper support of vertical delivery pipe line including clamps, nuts, bolts etc. And painting two coats with black synthetic paint over a coat of red oxide primer complete of Gde Fe-410 W (quality-A) all as specified and as directed  124 M&L for PCC 1:3.8, type C1 (using 20 mm graded stone aggregate) as in coping, bed plates, etc., including weathering. slightly rounded or chamfered angles and throating, necessary form work for LT pannel foundation etc. complete all as  125 M&L for Cutting existing road/PCC hard standing for making duct for laying LT XLPE cable of size 25 sqmm 4 core for LT panel all as specified and directed  126 M & L for medium grade galvanised pipe ISI Marked with all fitting on wall/floor, etc for bore 50 MM complete all as specified and as directed.  127 Supply, Install, Testing & Commissioning of MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 50 to 63 A - 02 Nos. (1W+1S) Make : Cat No : DZ0F0063CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.  128 M & L for concealed sub-main wiring alongwith earth wire of size (4 x 16.0) sq. mm + (1 x 16.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) of minimum size 25 mm dia with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed to the entire satisfaction of Engr-In-Charge. Make of cable : Havells/Polycab/Finolex/KEI. Make of Conduit : Polycab/Finolex/Modi/Precision.  129 M & L for concealed sub-main wiring alongwith earth wire of size (4 x 10.0) sq. mm + (1 x 10.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) of minimum size 25 mm dia with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed to the entire satisfaction of Engr-In-Charge. Make of cable : Havells/Polycab/Finolex/KEI. Make of Conduit : Polycab/Finolex/Modi/Precision. NOTE for Item above : 1) Four runs of PVC wire, One run of Earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Cost of Modular metal flush boxes (if any for junction inspection) is deemed to be included in the unit quoted rates. 3) Cutting chases & making good the disturbed surfaces is deemed to be included in the unit quoted rates. 4) Cost of PVC clamps/saddles of appropriate sizes with fixing screws for fixing on walls &/or PVC cable ties etc. for fixing on steel support members (if any) is deemed to be included in the unit quoted rates. 5) The wiring shall be done with proper colour coding using Red, Yellow & Blue Coloured wires only for Phase, Black for Neutral & Green for Earth Wire.  130 Supply and fix 415 V triple pole and neutral with a earth enclosure a three pin and earth plug and socket complete with one triple pole MCB, C Series, 10 KA, 63 Amps capacity complete all as specified and as directed.Make-L&T/LEGRAND/SIEMENS/ABB.  131 Supply and fix 415 V triple pole and neutral with a earth enclosure a three pin and earth plug and socket complete with one triple pole MCB, C Series, 10 KA, 20 Amps capacity complete all as specified and as directed.(for bio medical shredder)Make-L&T/LEGRAND/SIEMENS/ABB. NOTE for Item above : (i) Make of MCBs shall be same as the make of MCB DBs. (ii) Cost of making good the disturbed surfaces is deemed to be included in the unit quoted rates.  132 M&L for earthing complete with copper earth plate eletrode 600 mm x 600 mm x 3 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL ) with top edge of earth Plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using copper earth strip of size 20x3 mm connected by means of bolts, nuts, check nuts and washer of copper, provision of 40 mm dia GI pipe medium grade for protection of copper earth strip and 20 mm dia GI pipe pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber of size 45 cm x 45 cm x 45 cm including, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strenghth deformed steel TMT bars on bioth ways including necessary excavation in any type of soil, returning, filling in ,removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I complete all as specified and as directed. Note :- (i) Cost of copper earth strip and copper protection pipe upto 7.5 mtr length shall be deemed to be included in the rate quoted for the item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling, removing, PCC chamber pit, RCC cover, test point etc. (iii) On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory.  133 S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for looop earthing etc. as required copper strip of size 20 x 3mm complete all as specified & as directed to the entire satisfaction of Engr-In-Charge  134 S&F DMC/FRP insulators, of suitable size to separate the earth strip from the walls, duly screwed on the wall and making holes in the earth strips by drilling and fixing the earth strip rigidly with the insulators with GI bolts, nuts, washers etc complete all as specified & as directed to the entire satisfaction of Engr-In-Charge  135 M&Lfor GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah, Earthing etc. of bore 40 mm where required at site, complete all as specified and directed. Make : TATA/JINDAL/PRAKASH.IMP NOTES FOR ITEM above :1) Design / drawing / Layout of the complete Lightning Protection System is to be to be got approved from Engr-in-charge & GE before placing final order. 2) Any item/work etc. missed out in the technical specifications but technically required for efficient working of the complete system is deemed to be included in the quoted rates.3) On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory.4) The size of PCC Blocks shall be 150 x 150 x 150 mm.