Tender For Provision Of Men Toilet Blocks At Rvc Centre And College At Meerut Under Ge (Project) Meerut Cantt;  1 SCHEDULE A PART-I (BUILDING WORK)  2 Construction of TOLILET BLOCK NO-1 (S/S)(RCC Framed Structure) with permanent specification all as shown on drawings and as specified.  3 Construction of TOLILET BLOCK NO-2 (S/S)(RCC Framed Structure) with permanent specification all as shown on drawings and as specified.  4 Construction of TOLILET BLOCK NO-3 (S/S)(RCC Framed Structure) with permanent specification all as shown on drawings and as specified.  5 SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder  6 SCHEDULE A PART II-B (Internal Water Supply)  7 S&F 15mm dia 2 way bib tabbrass chromium plated one for health faucet and another for bucket filler complete all as specified and directed.  8 S&F Urinal spreader ofbrass chromium plated for fixing 15 mm dia pipe complete all as specified and directed.  9 S&F health faucet (ABS Body) MS CP suitable for 15 mm dia pipe with 1.25 m long flexiable tube & ABS wall hook including making connections and fixed in position complete all as specified and directed.  10 SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder  11 SCHEDULE A PART III-B (Internal Electrification)  12 M&L for point wiring with 1.5 Sqmm (nominal cross section area) single core, multi stranded PVCinsulated, unsheathed copper conductor, FRLSH cable in and including in rigid pvc conduit 20 mm dia or higher medium grade ISI marked complete with all steel conduit accessories / fittings and sunk pressed (1.2 mm thick) steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, including earth wire continuous of PVC insulated, unsheathed 1.5 Sqmm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic sheet screwed with brass screws, cup washers complete all as specified and directed for the following:-  13 (a) One light point point /bell buzze/ ceiling fan/Exhaust fan point controlled by one-one way 5/6 Amp switch.  14 (b) One 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch.  15 Supply & fix LED lamp 9 W 6500k,240V complete all as directed.  16 S & F lamp holder insulated body with back plate fix done anodised 100 x 100 mm pressed steel box flush to the wall with 3 mm thick backlite cover complete all as specified and directed.  17 Supply & fixingLED tube light fitting T/5 surface mounting poly carbonate 240 volts 20 watts, 6500K complete all as specified & directed.  18 M&L for Building security light fitting 1 x 35 LED type, drawn through and including GI bracket of size 25 mm dia bore light grade 1.4 mtr long, bend to shape including MS clamps made out of flat iron of size 32 x 4 mm - 02 Nos and necessary nuts, bolts, washer as required complete all as specified and directed.  19 S&F Exhaust fan steel bodyAC single phase 230/240V size 300 mm sweep with blades, and louvers including hole surface complete all as specified and directed.  20 Supply and fix sheet metal enclosure single pole & neutral for 240 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed.  21 Supply and fix MCB single pole 240 volt 6 to 32 amps 10 KA complete all as specified and directed.  22 Supply and fix MCB SPN 40 Amps, 240 volts, 50 Hz suitable for fixing in MCB DB C series complete all as specified and as directed.  23 Material & labour for earthing complete with galvanised mild steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part -I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completioncomplete all as specified and directed.  24 SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder  25 SCHEDULE A PART V (Road, Path and Culvert) for details refer pdf folder  26 SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder  27 SCHEDULE A PART VI B (Sewage Disposal)  28 S&F 25 users LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete forcomplete all as specified and directed.  29 M&L for construction of Soakage wells comprising of excavation, in any type of soil, foundation in PCC 1:3:6 type C2 , walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 4.5 M effective depthall as specified and as directed..Note : Ref TD - 309, Sheet No 1/4 to 4/4  30 SCHEDULE A PART VII(External Water Supply) for details refer pdf folder  31 SCHEDULE A PART VIII(EXTERNAL ELECTRIFICATION)for details refer pdf folder