Tender For Routine Maintenance, Upkeep & Breakdown Maintenance Of 400 /220 Kv Switchyard & Associated Equipments Inptpp, Parichha, Jhansi
Tender Value
19.26 Lakhs
Estimated cost
Bid Submission
19 Nov 2025
0 days left
EMD
40000
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
parichha → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Routine Maintenance, Upkeep & Breakdown Maintenance of 400 /220 KV Switchyard & Associated Equipments inPTPP, Parichha, Jhansi
BOQ
| Sl. No. | Item Description |
| 1 | Routine Maintenance & upkeep of 400 /220 KV Switchyard & associated Equipments of 2x250 MW PTPP, Parichha, Jhansi as per scope of work from Sl. No. A to G of Part-I & from Sl. No. A to D of Part-II |
| 2 | Installation of one complete pole of 400/220 KV CB along with associated work |
| 3 | Dismantling of one complete pole of 400/220 KV CB along with associated work |
| 4 | Replacement of interrupter unit of one pole of 400/220 KV CB |
| 5 | Only Dismantling OR only installation of interrupter unit of one pole of 400/220 KV CB. |
| 6 | Only Dismantling OR only installation of one arm of one pole of HCB Isolator of 400/220 KV |
| 7 | Replacement of one arm of one pole of HCB isolator of 400/220 KV. |
| 8 | Dismantling OR installation of 400 KV Pantograph isolator – one pole. |
| 9 | Replacement of 400 KV Pantograph isolator - one pole. |
| 10 | Replacement of trapeze assembly |
| 11 | To provide assistance in overhauling of one pole of 400 KV or 220 KV CB & its other associated works |
| 12 | Replacement of wave trap of one phase |
| 13 | Overhauling or replacement of gear operating mechanism of 220 KV HCB isolator (gang operated) OR one pole of HCB/Pantograph isolator of 400 KV system |
| 14 | Replacement of damaged P.G. clamp or jumper of 400 KV system |
| 15 | Replacement of damaged P.G. clamp or jumper of 220 KV system |
| 16 | Replacement of Male or Female contacts of one pole of 400 KV HCB Isolator |
| 17 | Replacement of Male or Female contacts of one pole of 220 KV HCB Isolator |
| 18 | Erection and Dismantling of Scaffolding in 220/400 KV switchyard per pole. |
| 19 | Installation of one No. H.T. bushing or its gasket or its bushing C.T. in 400/220 KV transformers including all associated works - 400 KV side |
| 20 | Installation of one No. H.T. bushing or its gasket or its bushing C.T. in 400/220 KV transformers including all associated works - 220 KV side |
| 21 | Installation of Neutral bushing |
| 22 | Replacement of HV or LV turret or Gasket |
| 23 | Modification of base of LA/CT/CVT of 400 KV or 220 KV system & necessary connection modification of jumper (excluding removal/installation of LA/CT/CVT) |
| 24 | Replacement of 400KV line side dropping conductor with associated work. |
| 25 | Replacement of 220KV line side dropping conductor with associated work. |
| 26 | Replacement & installation of 4 inch or 3 inch aluminum pipe conductor. |
| 27 | Replacement & installation of 400KV or 220 KV side CT/CVT/LA OR ISOLATOR dropping conductor with associated work. |
| 28 | Replacement & installation of 400KV or 220 KV side insulator string with associated hardware. |
| 29 | Replacement of damaged CT/CVT/LA of one pole of 400/220 KV system by new similar equipment. |
| 30 | Installation of one Radiator bank of ICT / Reactor |
| 31 | Tightness of clamp and conductor connection at One Clamp of 400/220 KV CT or 400/220 KV Isolator |
| 32 | Tightness of clamp and conductor connection at One clamp of 400 KV CVT |
| 33 | Tightness of clamp and conductor connection at One clamp of 400/220 KV LA |
| 34 | Tightness of clamp and conductor connection at One clamp of 400/220 KV Circuit Breaker |
| 35 | Proper cleaning and painting inside and outside fencing of 400 & 220 KV switchyard and transformer yard |
| 36 | Proper cleaning and painting of various electrical equipments in switchyard and transformer yard as per scope of work |
| 37 | Overhauling of dewatering pump installed in 400 KV Switchyard with associated work. |
| 38 | Replacement of PRV of ICT/ Reactor |
| 39 | Replacement of one Buchholz relay of ICT/Reactor/ Transformer |
| 40 | Shifting of one centrifuging machine of 10KL/6 KL capacity from transformer yard to switchyard |
| 41 | Shifting of one 10 KL capacity oil tank |
| 42 | Shiftingof 400KV or 220KV Breaker/bushing/current transformer or CVT from central store to switchyard /Shifting of damaged equipment from 400/220 KV switchyard to any assigned site inside the plant |
| 43 | Shifting of new transformer oil filled drums from central store/ any site within plant to transformer yard/ shifting of old transformer oil filled drum from site to CSD store or at the assigned site. |
| 44 | Shifting of empty transformer oil drums from Site to CSD store. |
| 45 | Centrifuging of 315 MVA ICT/125 MVAR Reactor (1 JOB= 8 Hrs) |
| 46 | Removal of ICT cooling fan motor from its foundation and installation after completion of work |
| 47 | Bearing replacement in Cooling fan motor of ICT |
| 48 | Manpower assistance in testing work of ICT/Reactor |
| 49 | Fabrication of new shaft for 400/220 KV isolators gearbox |
| 50 | Replacement of new shaft in 400/220 KV isolators gearbox |
| 51 | IR Value improvement of cooling fan motor of ICT |
| 52 | Opening /mounting of 1 set (3 nos)jumper/PG Clamp of CT/CVT/Bushings/Circuit breakers |
| 53 | Nomenclature writing on electrical panel,cubicles etc. |
| 54 | Supplyand replacement of check valve ,gland and gasket of dewatering pump |
| 55 | cleaning of grass,Vegetations in switchyard ,disposing the waste & antiweed treatment |
AI Tender Summary
Tender Timeline
Oct 29, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 20, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender