Tender For Maintenance Of Outdoor Illuminations And Electrical Systems At Rrcat, Indore; 1 Maintenance/Replacement of70 W HPSV/MH/CDM luminaire on post top lantern andLED luminaire pole (up to 5 meter height) :-Replacement of set of component of 70 W HPSV/MH/CDM-TT lamp, ballast, ignitor and LED luminaire in existing post top lantern pole and LED pole including cleaning, repairingand testing etc. 2 Maintenance/Replacement of luminaire suitable for 35-120watt (LED)/150/250 watt HPSV/ MH/CDMover J pole/Archeological pole and replacement of components viz. lamp/ballast / ignitor /Holder/LED luminaire etc (>5 Mtr < 12 Mtr height). Replacing the components /luminaire and testing of the luminaire including repairing in wiring etc., if needed. Refix the fixture over pole with proper tightening of clamps and bolts. Test it again after fixing. 3 Maintenance/Replacementof luminaire : 4 Maintenance/Replacementof luminaire suitable for 150/250/400 watt MH/HPSV/160wat LED over High bay area (>13 Mtr < 17 Mtr height) and replacement of components viz. lamp/ballast / ignitor /Holder/LED luminaire etc.Replacing the components and testing of the luminaire including repairing in wiring etc., if needed. Refix the luminaire over pole with proper tightening of clamps and bolts. Test it again after fixing. 5 Maintenance/Replacementof luminaire suitable for 150/250/400 watt MH/HPSV/160wat LED over court yard area (>13 Mtr < 17 Mtr height) and replacement of components viz. lamp/ballast / ignitor /Holder/LED luminaire etc.Replacing the components and testing of the luminaire including repairing in wiring etc., if needed. Refix the luminaire over pole with proper tightening of clamps and bolts. Test it again after fixing. 6 Maintenance/Replacement of luminaire suitable for 150/250/400 watt MH/HPSV/ upto 160wat LED over parapetand replacement of components viz. lamp/ballast / ignitor /Holder/LED luminaire etc.Replacing the components and testing of the luminaire including repairing in wiring etc., if needed. Refix the luminaire over pole/roof/parapet wall etc.with proper tightening of clamps and bolts. Test it again after fixing. 7 Control Terminal box :-Replacement/Supply , installation , testing & commissioning ofpowder coated sheet steel enclosure (size-375x175x75mm) made out of 1.5mm GI sheet fitted with insulators SP-MCB and clamps this includes disconnection, reconnection using by glands and lugs if required, dismantling of existing boxes and stackingwithinRRCAT campus as directd by EIC. 8 Driven rod:- Supply,installation and testingof 25 mm dia , 1.5 meter long driven rod forearthing including welding of 6mm X 25mm long M.S. bolt on existing pole and termination of 10 SWG G.I.wire as directed. 9 Attending/maintenance of the street light cable end termination box and replacement of existing MS clamps with new 15x5mm aluminium clamps (02 Nos) or components if required 10 Excavation: Only excavation and backfilling ofall types of soil soft /hard murrum/ boulders etc. 11 Power Cabling/Telephone cable 12 Power Cabling :- (In Ground)Only Installation,testing and commissioningof XLPE/PVC (FRLS)heavy duty power cable 1100V grade aluminium/copper conductor installed 900 mm below in ground by using over burnt bricks including excavation , sand cushioning, protective covering and refilling the trench compacting including watering , leveling the trench, removing the excess soil etc. Size of cable - up to 3/4 core 35 sq.mm 13 Power Cabling :- (On Wall/Trench)Only Installation,testing and commissioningof XLPE/PVC(FRLS)heavy duty power cable 1100V grade aluminium/copper conductor installed on wall/trench. Size of cable - up to 3/4 core 35 sq.mm 14 Power Cabling :- (On Wall/Trench)Only Installation,testing and commissioningof XLPE/PVC(FRLS)heavy duty power cable 1100V grade aluminium conductor installed on wall/trench. Size of cable - 3½ X 120/150/240 sqmm Al armoured XLPE cable. 15 Power Cabling :- (In Existing Hume pipe/GI pipe)Only Installation,testing and commissioningof XLPE/PVC (FRLS)heavy duty power cable 1100V grade aluminium/copper conductor installed in existing hume/GI pipe. Size of cable - up to 3/4 core 35 sq.mm 16 Power Cabling :- (In Ground)Supply, installation,testing and commissioningof 3½ core 50 sq.mm XLPE (FRLS)heavy duty power cable 1100V grade aluminium conductor installed 900 mm below in ground by using over burnt bricks including excavation , sand cushioning, protective covering and refilling the trench compacting including watering , leveling the trench, removing the excess soil etc. 17 Power Cabling :- (On Wall/Trench)Supply, installation,testing and commissioningof 3½ core 50 sq.mmheavy duty power cable 1100V grade aluminium conductor installed on wall/trench. 18 Telephone Cabling :- (In Ground)Supply, installation,testing and commissioningof 0.5mm annealed bare copper conductor, polythene insulated, colour coded, jelly filled armoured telephone cable. Installed 900 mm below in ground by using over burnt bricks including excavation , sand cushioning, protective covering and refilling the trench compacting including watering , leveling the trench, removing the excess soil etc.Size of cable - 5 pair 19 Telephone Cabling :- (On Wall/Trench)Supply, installation,testing and commissioningof 0.5mm annealed bare copper conductor, polythene insulated, colour coded, jelly filled armoured telephone cable installed on wall/trench. Size of cable - 5 pair 20 Power Cable End Termination:- Supply , installation , testing & commissioning of end jointing for electrical aluminium armoured PVC/XLPE insulated (AYFY/A2XFY)cable 1100V grade by usingdouble compression Nickle Plated Brass Gland and Aluminium lugs. 21 4 core10 sq.mm 22 4 core16 sq.mm 23 4 core25 sq.mm 24 3½ core 50 sq.mm 25 3½ core 150 sq.mm 26 3½ core 240 sq.mm 27 Telephone Cable End Termination: Supply , installation , testing & commissioning of end termination of 5pair 0.5mm annealed copper conductor, polythene insulated, colour coded jelly filled armoured telephone cable. This Includes cleaning of cable by kerosene and supply of other materials required for end jointing. 28 Preventive Maintenance including overhauling and rectification of faults if any of Lighting High Masts system having 12 Nos LED Luminaires. LED luminaires will be supplied by department if required for replacement. Detail of activity shall be as per tender specifications 29 Supply and installation of 600mm long cable route marker made out of ISA(50x50x5mm) with masonary work and embossing LT cable on tag. 30 PCC WORK:-Cement concrete 1:2:4 using graded stone aggregate 40 mm maximum size including machine mixing,consolidating,finishing,curing etc completeincluding form work. 31 Structural steel work at all levels including supply, cutting, fabricating, welding including necessary scaffolding erecting & fixing in position, including painting with primer coat of approved steel primerMS pipe/clamps for street light pole or trench cover as per site requirement ) 32 Supply, fabrication (by using CRCA sheet steel) and installation of sheet steel bus duct,cable trays,panel and MS boxes with complete chemical and mechanical process on MS sheet or angle etc powder coated,rubber gasket,locking arrangement,earthing bolt etc will be provided on the fabricated item as per requirement and specifications. 33 Supply,installation, testing and commissioning/Replacement of 240 volts LED street light Luminaires having IP-65 protection with optical system,heat sink,driver in to one compact housing with lumen output ≥ 2500 34 Supply,installation, testing and commissioning/Replacement of 240 volts LED street light Luminaires having IP-65 protection with optical system,heat sink,driver in to one compact housing with lumen output ≥ 4000 35 Supply,installation, testing and commissioning/Replacement of 240 volts LED street light Luminaires having IP-65 protection with optical system,heat sink,driver in to one compact housing with lumen output ≥ 11500 36 Supply,installation, testing and commissioning ofoutdoor surface mounting LED 70 watt, lumen output 7000 lumen, IP65, CRI>70 in compact housing with driver. Scope shall include removal of existing luminaire with all accessories and stored in within RRCAT campus. 37 Supply,installation, testing and commissioning ofhighbay recessed/surface mounting with all accessories, nominal wattage150 Watt and lumen output≥15000 lumen, IP65, CRI>70. Removal of existing luminaire with all accessories and stored in within RRCAT campus. 38 Supply,installation, testing and commissioning ofoutdoor installation of LED integral flood light with driver in one compact housing. Luminaire should have nominal efficacy ≥ 130 lm/watt, nominal output as 23400 lumen, Colour temperature : 5700K, CRI ≥ 70, IP/IK: 66/8, THDi: < 10% at full load,4 kV surge protection minimum, Optics: exposed lens optics policarbonate, Life Class: L70 @ 50K hrs. & complete with all accessories and driver. Removal of existing luminair with all accessories and storing within RRCAT campuss is also in the scope of this item. 39 Supply,installation, testing and commissioning of outdoor installation of LED integral flood light with driver in one compact housing. Luminaire should have nominal efficacy ≥ 120 lm/watt, nominal output as 42000 lumen, Colour temperature : 5700K, CRI ≥ 70, IP/IK: 66/8, THDi: < 10% at full load,4 kV surge protection minimum, Optics: exposed lens optics policarbonate, Life Class: L70 @ 50K hrs. & complete with all accessories and driver. Removal of existing luminair with all accessories and storing within RRCAT campuss is also in the scope of this item. 40 Supply,installation, testing and commissioning of 30 watt, 2X2feet LED integral recess mounted with driver in one compact housing luminaire. Luminaire should have nominal efficacy ≥ 100 lm/watt, nominal output as 3000 lumen, Colour temperature : 6500K, CRI ≥ 80, THDi: < 10% at full load,2.5 kV surge protection minimum, Optics: exposed lens optics policarbonate, Life Class: L70B50 @ 40K hrs. & complete with all accessories and driver etc. Removal of existing luminair with all accessories and storing within RRCAT campus is also in the scope of this item. 41 Supply,installation, testing and commissioning 125A, 415volt ,4P (four pole) motorisedAutomatioc Transfer Switch (ATS) suitable for sheet steel enclosurewith digital programmable controller. 42 Supply,installation, testing and commissioning 250A, 415 volt, 4P (four pole) motorisedAutomatioc Transfer Switch (ATS) suitable for sheet steel enclosure with digital programmable controller. 43 Painting of Street light Poles : Painting on steel work in two coats of Aluminium paint of approved shade and make over one coat of steel primer including preparing surfaces, scaffolding and cleaning, tools & tackles and safety is part of contractor. 44 Painting of Street light Foundtion : Painting the old exterior walls and roof with two coats of Snowcryl XT acrylic emulsion/APEX Ultima over one coat primer, of approved shade including preparing the surface by removing loose dust and dirt with stiff brush and washing the surface with clean water, treating the surface with antifungal chemical wherever required, filling with putty, scaffolding and cleaning etc. complete. 45 Hire charges for deploying hydraulic elevating/eccess plateform with (fitted onto SCV/LCV chassis) operator for works pertaining to trimming/pruning of tree branches and replacement of street light/coarts luminaires. 46 Hire charges for chain saw machine/brush cutter (non electric) with cost towards fuel/oil etc. with operator and helper for carrying out trimming/chopping of tree branches. 47 Supply,installation, testing and commissioning of 5 meter high GI octogonal pole including its foundation, MCB and earthing etc. 48 Supply and installation of 50mm dia of 4kg pressure HDPE pipe. Installed 900 mm below in ground by using over burnt bricks including excavation, sand cushioning, protective covering and refilling the trench compacting including watering, leveling the trench, removing the excess soil etc. 49 Supply and installation of 50mm dia Class- B GI pipe with cutting and drilling etc. 50 Executionof electrical maintenance jobs and electrical maintenance activities by skilled man power of breakdown maintenance,routine maintenance and preventive maintenance at ARPF and RRCAT.