| 1 | Demolition of brick work or stone boulder/ PCC block masonry, built in cement mortar or cement lime mortar incl all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articlescomplete all as specified and directed. |
| 2 | M&L PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation filling, fencing post and mass concrete of any description, complete all as specified and directed. |
| 3 | M & L in walling of random rubble, uncoursed, Bangalore type masonrywell bonded bedded solidly hearted built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4, complete all as specified and directed. |
| 4 | Walling of random rubble, uncoursed, Bangalore type masonry (except stone) well bonded bedded solidly hearted built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4 and including removal and refixing, built in cement mortar of any description as specified and directed.(Note:- Stone retrieved under item No. 3 above shall be re-used) |
| 5 | M&Lin Pre-cast PCC 1:3:6 type C1 (using 20 mm graded stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 of any description as specified and directed. |
| 6 | M&L 10 mm thick cement plaster in CM 1:6 on fair faces of brick work/concrete etc surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 7 | Racking out joints / points in cement mortar to squared rubber masonry coursed or uncoursed and including M & L keyed pointed in CM 1:4 for squared rubble masonryas specified and directed. |
| 8 | M&L Cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed . |
| 9 | S & F in repair concertina coilof 610mm dia (in stretched position) hot dip galvanised steel wire coated with CLR ante corrosive coating making diamond shape with the help of devotail clips (18 SWG) fixed over barbed wire with the angle iron the concertina coil is to be fixed with barbed wire at points where coil touched the bottom barbed wire with the help of hog rings (14 SWG) complete all as specified and directed. |
| 10 | S&F of TMT bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 11 | All as per item No. 10 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed. |
| 12 | M&L for reinforced cement concrete M-25 (design mix) using 20mm graded aggregate for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 13 | Use & waste of formwork to rough finished surfaces of sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete measured flat for foundation complete all as specified and as directed. |
| 14 | S&F in repair galvanised two strand steel barbed wire 2.24mm dia barbed wire with 2 mm barbs at 75mm spacing and straining and fixing to any type of standard angle rails straining bolts or welding to angle, including securing or tying at crossing with and provision of galvanised MS wire staples or steelpins etc as directed(each line wire to be measured) |
| 15 | M & L for 25 mm thick layer of cement mortar (1:3) as required with a rounded or weathered finish and before the mortar has set & fixing glass (of bottle or thick glass) broken to approximately 63 mm gauge, firmly embedded @ of 10 kg of glass per Sqm of rendered surface, jogged edges of the glass being left projecting, complete all as specified and as directed. |
| 16 | S&F Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions (Fixed/movedportions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, star lock, bottom and top railing for sliding, necessary locking arrangment(mortice lock) included rubber beading all complete as per architectural drawings and complete all as specified and directed. |
| 17 | Supply and fixing in powder coated aluminium shutters of window, doors and ventilator, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodisedaluminium fittings such as peg stays150mm long (1 no.) hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, star lock, included rubber beading all complete as per architectural drawings and all as specified and directed. |
| 18 | Material and labourfor 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, including side beading fixed with screws to Aluminium frame work complete all as specified and directed. |
| 19 | Supply and fixing 12mm thick Veneered particle board, solid core, exterior grade, with decorative face veneers for both faces, lamination, including side beading fixed with screws complete all as specified and directed. |
| 20 | S&F 5 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50 Sqm in each pane complete all as specified and directed. |
| 21 | S&F 5 mm thick sheet glass ordinary quality and glazing complete in square exc 0.50 Sqm in each pane complete all as specified and directed. |
| 22 | Supply and fixing in repairs MS Mortise lock, 4 levers vertical type, size 100 mm for fixing to glass all as specified and directed. |
| 23 | Taking downcementplaster on stone wall or brick work etcincluding racking out of joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 24 | M & L for preparation of new plastered surfaces of walls applying one coat of wall care putty and then applying two coats of premium oil bound distemper over one coat of primer as per manufacture instruction of required shade complete all as specified and directed. |
| 25 | M&L for Preparation of old decorated surfaces of wallsby using pressure washer, remove all dirt & dust ,applying one coat of wall care putty and then applying two coats of premium oil bound distemper over one coat of primer as per manufacture instruction of required shade complete all as specified and directed. |
| 26 | S&FHydraulically regulated opening door closer universal type designation No. 3aluminium of extruded section (ISI Marked)suitable any size for glass door shutters of weight not more than 80 kg and fixed with screws including fixing to toughned glass for necessary double side opening complete all as specified and directed. |
| 27 | S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel covert governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. |
| 28 | Dismantling wrought iron or mild steel work of any description all as specified and directed. |
| 29 | S & F mild steelwork in framed brackets of angle or tees with web flanges cut to shape, drilled and countersunk of screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc, 10 kg each bracket, and hanging also fastening and fixing complete conforming to Gde Fe 290, Gde E-165 complete all as specified and directed. |
| 30 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both end each screwed end to be fitted with washers and one hexagonal or square nut, but length of bolt exc 10 cm andn exc 15 cm longof 5 to 10 mm dia of neckcomplete all as specified and as directed |
| 31 | Surface excavation n exc 30 cm deep and avg 15 cm deep and getting out in soft/loose of soil and removing the same outside MD land complete all as specified and directed. |
| 32 | M&L 75mm thick PCC type D-2 (1:4:8) using 40mm graded stone aggregate as in sub base to floor surface finished even and fair complete all as specified and directed |
| 33 | M&L hard core of broken stone of guage n exc 63mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 34 | M&L100 mm thick, Cement concrete 1:2:4,type B2 using 40 mm graded stone aggregate as in pavings, hardstandings and similar work surface finished even and fair without using extra cement complete all as specified and directed.. |
| 35 | M&L for preparation of newsurfaces of steel or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and as directed |
| 36 | M&L for rendering 15mm thick cement plasterin CM 1:4 on fair faces of brick work or concrete surfaces on external surfaces finished even and smooth without using extra cement including taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified and directed. |
| 37 | M&L for treating with three coats of whitewash on new surfaes of walls incl necessary preparation to give uniform and smooth finish complete all as specified and directed. |
| 38 | Note :- An amount of Rs 63,560.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |