Tender For Provision Of Sun Shelter At Af Stn Jaisalmer;  1 SCHEDULE A PART I is not prepriced by MES and prepriced rates indicates 0.00 under col 5 signified this fact only . (TO BE QUOTED BY THE CONTRACTOR) Bidders shall insert their lumpsum amount in BOQ Ser No 1 in the Green coloured field under Col-6 only.Note : The quoted rate against is deemed to included for the provisions contained in Sch A Notes. Ref Sch A Notes complete before quoting these items. Structural design and structural drawings for super structure and foundations for the building/structure shall be prepared to comply with the provisions for design and analysis of RCC structures as per latest editions relevant IS Codes  2 Schedule ‘A’ Part I : BUILDINGS/ STRUCTURES (TO BE QUOTED BY THE CONTRACTOR)  3 Lumpsum price worked out for Supply and Errection of Sun Shelter of Pre Engineered Structure (PEB) of size (30m x 25m) complete all as specified in schedule ‘A’ Part I, scope of work, Sch A Notes, drawings, specifications and other parts of tender documents as directed.  4 Lumpsum price worked out for Supply and Errection of Sun Shelter of Pre Engineered Structure (PEB) of size (25m x 25m) complete all as specified in schedule ‘A’ Part I, scope of work, Sch A Notes, drawings, specifications and other parts of tender documents as directed.  5 NOTE: Schedule ‘A’ Part II to V under Ser No. 3.00to 6.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only.  6 Lump sum price worked outfor EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch A Part II.  7 Lump sum price worked out for FLAME PROOF INTERNAL ELECTRIC SUPPLY as listed in Sch A Part III.  8 Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch A Part IV.  9 Lump sum price worked out for EXTERNAL ELECTRIC SUPPLY as listed in Sch A Part V.  10 SCHEDULE A PART - VI MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6.  11 BUILDINGS/ STRUCTURES  12 Supply and fixing of bird proofing net 2.5mm thick, 30mm mesh size, HDPE braided net including tying with nylon wire at any height as per manufacture’s instructions all as specified and directed.  13 FLAME PROOF INTERNAL ELECTRIC SUPPLY  14 S & F for Flame proof brass unions suitable for 20 mm ERW conduit complete all as specified and directed.  15 S & F for Flame proof brass bends suitable for 20 mm ERW conduit complete all as specified and directed.  16 S&F flame proof /Weatherproof 4 way junction box, 100 mm dia with 4 Nos,terminal for looping in and looping out connections complete all as specified and directed.  17 S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 32A, 415 Volts, 5 Pin (4P+earth) complete all as specified and directed.  18 S&F flame proofSheet steel metal enclosure of size 480 X 480 X 250mm, CMRI certified distribution box , 8 Way 415 Volts with MCCB 4 Pole, 63 Amps-1 No, Outgoing MCB SPN, 240 Volts 5-32 Amps- 12 Nos complete with internal Bus Bar & wiring upto terminal complete all as specified and directed.  19 S&F flame proofSheet steel metal enclosure of size 420 X 480 X 250mm, CMRI certified distribution box , 4 Way 415 Volts with MCB 4 Pole, 63 Amps-1 No, Outgoing MCB SPN, 240 Volts 5-32 Amps- 06 Nos complete with internal Bus Bar & wiring upto terminal complete all as specified and directed.  20 S & F forFlameproof/ weatherproof LED flood light fitting 200 Watt , IP 66 protection of Cast Aluminum alloy in LM6material and Heat and Impact resistance toughen A clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired duly certified by CMRI Dhanbad and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.  21 M & L for surface flame proof Sub main wiring with under mentioned single core PVC insulated unsheathed multistrandedwith copperconductorcable, 1100Volts FRLS-Hgrade ISImarkeddrawnthrough in and including ERW steel conduit with flame proof accessories and including onerun ofFRLS-H PVCinsulated single core cable unsheathed strandedcopper conductor cablegreenin colour forearthcontinuityconductor complete all as specified and directed.Note :- Two runs/ four runs single core cableandone/ tworuns single core cable ofearthwire and one run of ERW steel conduit pipe shallbemeasuredasonelength.  22 4 run of 4.0 Sqmm single core cable and 2 run of 4.0 sqmm single core cable connected to common earth dolly.  23 4 run of 6.0 Sqmm single core cable and 2 run of 6.0 sqmm single core cable connected to common earth dolly.  24 M & L for maintenance free Chemical earthing of technology 3 mtr long 17.20 mm dia with 250-micron Copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed.  25 Note:-(i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 (ten) years after certified date of completion and shall be deposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 1.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete.  26 LIGHTENING PROTECTION  27 M & L for maintenance free Chemical earthing of technology 3 mtr long 17.20 mm dia with 250-micron Copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed.  28 Note:-(i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 (ten) years after certified date of completion and shall be deposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 1.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete.  29 EXTERNAL ELECTRIC SUPPLY  30 Supply and lay fordouble wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II) for protection of underground cables of size nominal outer dia 63 mm & nominal inner dia 50 mm dia with all fittings laid in trenches / road/ nallah or fixed along wall for cable protection all as specified and directed.  31 S & F Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with DANGER / LT CABLE /MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required/ ordered at site) complete all as specified and as directed.  32 Supply,Install & testing Self supporting cum extendable Aluminium Ladder with a closed height of 18 feet extendableup to 32 feet made out of high grade corrosion resistant aluminium alloy with a two section telescopic design and automatic locking system for height adjustment. The ladder shall have anti skid rungs, a wide stebiliser base with anti slip rubber feet and suitable load capacity at least150 Kg and ensuring stability and safety confirm to IS 4571-1977/ EN 131 standards. Note:- The scope includes supply, installation, functional testing and user demostartion with a minimum 12 Month warrantey from date of installation.