Tender For Repair/Renovation Canteen And Guard Room, P/L Paver Block, Gully Chamber Etc. Misc.Work At International Student House, University Of Delhi; 1 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloadingto approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 2 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from naturalsources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 5 Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at allevels. Granite stone slab colour black, Cherry/Ruby redArea of slab upto 0.50 sqm 6 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 7 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of doorshutter to be measured). 8 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With 2nd class teak wood beading 62X19 mm 9 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 10 Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion (i) Single socketed pipes. 110 mm diameter 11 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 12 Coupler 110 mm 13 Single tee with door 110x110x110 mm 14 Bend 87.5° 110 mm bend 15 Shoe (Plain) 110 mm Shoe 16 Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions asper IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). : 0.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. 17 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) 18 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. 19 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) 20 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 21 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approvedbrand and manufacture, including applying additional coats whereverrequired, to achieve even shade and colour. Two coats 22 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surfacesmooth including necessary repairs to scratches etc. complete. sqm 23 Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade : One or more coats on old work 24 Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface 25 Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 26 Demolishing mud phaska in terracing and disposal of material within50 metres lead. 27 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 28 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.: 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 29 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe 30 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 31 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using2.75 kg/sqm ofcement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoinin walls upto 300 mm height including rounding of junctions o walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimumthickness at khurra as 65 mm. 32 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per directionof Engineer-In-Charge. Bars upto 12 mm diameter 33 Providing, mixing and applying bonding coat of approved adhesiveon chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm ofsurface area mixed with specified proportion of approved polymer 34 Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.12 mm average thickness 35 Providing and fixing a custom-built cupboard with total overall depth of 450 mm. The main structure of the cuphoard, including the sides, top, bottom, shelves, and shutters, shall be fabricated using 18 mm thick HOHMR(one side prelaminated) board of approved brands such as Action Tesa, Green Ply, or Century. The rear panel shall be made from 8.00mm thick HDHMR (one side prelaminated), the exterior must he covered with sunmica as well the sunmica shall be of approved brand only. The scope includes supplying and installing oll necessary hardware fletings and fixtures, such as hinges, handles, Godre) Multipurpose locks, stoppers, screws, and other accessorles. The entire work shall be carried out as per the instructions of the Engineer-in-Charge, ensuring proper alignment, finishing, and durability. ( Note: For the purpose of payment, only the front face area of the cupboard will he measured in square meters, internal details wil not be measured separately.) 36 P/F costom built cupboard, The shutters are to be made from 18 mm thick HDHHMR board ( from brands like Action Tesa, Green ply, or Centuary or equivalent)and covered on both side with 1mm sunmica (from same brands or equialent) A complete wooden frame is required for the shutter made from 75mm x 40 mm second class teak wood, including any necessaryintermediate supports. The wooden frame must be polished with french spirit . The scope includesa applying and fitting all required hardware and fixtures (Godrej) 25 mm curvo wardrobe Multipurpose lock). All work must be completed according to the instructions of The Engineer-in Charge.(Note: for the purpose of payments, only the front face area of the cupboard will be measured in square meters, internal details will not be measured separatey)