}

Tender For Maintenance Of Various Sports Complex.Sh: Renovation Of Admin Block, Old Nursery & Yoga Hall By Iei And Sitc Of Fan, Lights And Other Electrical Work At Rskp Pitampura., Delhi-Delhi

Tender Notice

52011831
Tender For Maintenance Of Various Sports Complex.Sh: Renovation Of Admin Block, Old Nursery & Yoga Hall By Iei And Sitc Of Fan, Lights And Other Electrical Work At Rskp Pitampura.
Tender
Indian
Delhi
Delhi
04-11-2025

Tender Details

Maintenance of various sports complex.SH: Renovation of Admin Block, old nursery & yoga hall by IEI and SITC of fan, lights and other electrical work at RSKP Pitampura.; 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.a)Group C 2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 3 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 4 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 5 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required 7 3 x 1.5 sq. mm 8 6 x 1.5 sq. mm 9 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as require 10 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required 11 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 12 20 mm 13 25 mm 14 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 15 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required 16 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 17 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 18 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way , Double door 19 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). a)4 way (4 + 12), Double door 20 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 21 a)Single pole 22 b) Single pole and neutral 23 Supplying and fixing following rating, TPN, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 A 24 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required .a)125 A, 36KA,FPMCCB 25 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 26 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 27 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 28 Supply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC) Motor, remote, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based)for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor singlecorecableandearthingetc.asrequired. a)1200mm,service value≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 29 Supplying, installation, Testing & Commissioning of 36 W Panellight 2x2 ft.,of following body materialand construction as per IS : 10322 withdriver as per the requirementwith Driver efficiency >85%,Operating voltage AC140-270 Volt,frequency 50/60hz,Operatingtemprange-50Cto400C,internalsurge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95,IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flickershould be below 5 %), life time (LED, Driver & electrical circuitry), of minimum50000 Burning Hours with, 70% of initial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K/5700°K /6500°K(As perANSI Bin), SDCM(Standard Deviation Colour Matching) <3,Maximumpower consumption should not more than the specified rating and Fixture shall be ofrelevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completeinall respecti/cexternal connectionswith1.5sqmmFRLS/HFFR,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105<120 lm/Watt output . LM79 & LM80 Test report andalltestingrequiredforLED fixtures as per BISshall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminiumhousing such that LED junction temperature shall not rise above 90°C). Powdercoateddiecast/Extruded aluminium Body (Thickness > 1.20 mm) 30 SSupplying, installation, Testing & Commissioning of 18 W LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Typeof following body materialand construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0Cto400C,internalsurgeprotectionof2.5KVwithShort&Opencircuit protection ,THD < 10% , P. F.≥0.95,IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%),life time (LED, Driver & electrical circuitry), of minimum50000 Burning Hours with70% of initial Lumenmaintained tilllife ends, CCT 3000°K /4000°K/ 5700°K /6500°K (AsperANSIBin), SDCM (Standard Deviation Color Matching) <3,Maximumpowerconsumptionshouldnotmorethan the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing Completeinallrespecti/c external connectionswith1.5sq.mmFRLS/HFFR,PVCinsulatedcopper conductor single core cable and earthing etc. as requiredwith Minimum 5 year OEM warranty.System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report andalltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminium housing such that LED junction temperature shall not rise above 90°C)Powdercoateddiecast Extruded aluminium Body including trim with Aluminium Reflector. 31 Supply and fixing of 400 mm wall fanetc complete as required. 32 Supply of XLPE power cable of 1.1 kV grade armoured aluminium conductor power cable (As per IS 7098 (Part-1) of the followng sizes complete as required.A) 4 x 50 Sq mm 33 Supply and fixing of CO2 typeFire Extinguisher of 4.5 Kg, Duly ISImarked conforming to IS: 15683, complete with delivery hose horn , wheel type release valve, locking arrangement, pressure gauge, operation manual and bracket etc. complete as required. 34 supply and fixing of ABC Power MAP-90 Fire Extinguisher of 6 kg , Duly ISI marked conforming to IS: 15683:2006, with squeeze grip release valve,locking arrangement, pressure gauge, operation manual and backet etc. Completed as required. 35 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. A) 90mm dia ( OD-90mm and ID -76 mm nominal )

Key Value

Document Fees
Refer document
Tender Value
INR 11.57 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail