Rates For The Non Csr Items For Construction Of Proposed Government Medical College Of Capacity Of 100 Students With Attached 430 Bedded Hospital At Hinganghat ( Jam) Wardha Dist Wardha , Item Name , Effluent Treatment Plant- 35 Kld Supply Installation & Testing Of Daf Unit Base 35 Kld Effluent Treatment Plant , For Design Parameter Ph 6 _8 Cod Approx 2000_5000 Ppm,Bod Approx 3000_4000 Ppm-_ Tss Approx 1000_2000 Pppm Oil & Grease Approx 30_50 Ppm Etc , Grease Interceptor Supply Of Grease Separator Made Of Polyethylene As Per Din En 1825; Proven Stability Of 50 Years; Forbelow Ground Installation;Overall Dia Of 1320 Mm.; With Ventilation Provision; Emptying Via Suction Line Dn 65 Pn 10; Counter Flange With Fire Hose Quick Coupling 75B And 2½ Blank Cap And Satisfy Reaction To Fire Class A . Standard Odour Tight Top Cover Of 600 Mm Dia. Clear Opening; Frame Made Of Concrete Material And Cover Made Of Cast Iron; With Raising Tube, Load Class A15 According To En 124 Inlet And Outlet Dia: Dn 150 Make: Aco: Model: Lipumax Pd Nominal Size: Ns 10 Grease Storage: 415L, Sludge Storage: 1010L, Overall Capacity: 2170L Art No: 3210.81.00 + 3300.14.01 , Supply Of Aco Ss Box Channels (Lxw) Of Ss 304 Grade Confirming To En 10088, With Depth Varying From 100Mm T0 120Mmmm At Edge To 3 To 5. Mm At Centre With Outlet Dia 142Mm Compatible With Aco Gully Vertical Outlet Dn 110 , With Sectional Slope 5° And Longitudinal Slope Of 1%, V Shape Bottom And Material Thickness 1.5Mm With Slip Resistant Stainless Steel Grating Designed As Per Load Class .... Confirming En 1253 And Confirming The Hygiene Design As Per En 1672 & Principles As Per Ehedg Guidelines Like - Full Drainability,Edge Infill - Which Minimises Floor Cracks And Support To The Edge Of Channel . The Channels Will Be Provided With Easy Fix Levelling Feet And Anchors For Fixing In Concrete.Aco Antislip Mesh Grate: The Mesh Size Design 25 X 25 Mm Made Of Ss 304 Grade Material With Slip Resistant R11 (Din 51130) Design Of Load Class L-15 Certified As Per En 1253 , Supply Of Aco Fixed Height Ss Gullies 200Mm .X 200Mm . Mm Deep Drawn Gullies Of 304 Grade Confirming To Din En 10088 With Vertical/ Horizontal Outlet Of ..... Dia And Of Thickness 1.5Mm With Hygienic Slip Resistant Stainless Steel Grating Designed For Load Class.... Confirming To Din En 1253. The Gully Will Be Designed As Per Hygiene Design Guidelines Din En 1672 & Ehedg Guidelines - Full Drainability, With Edge Infill For Supporting The Edge Of Channel, Hygienic Joint And Radial Corners From Inside Edge For Full Cleanability. The Gullies Will Be Self Cleaning Type With Full Removable And Cleanable Foul Air Trap (Fat) With 50 Mm Water Seal And Removable Silt Basket. The Gullies Will Be Provided With Friction Ring & Easy Fix Levelling Feet And Anchors For Fixing In Concrete. The Gullies Will Be Fully Pickle Passivated, High Corrosion Resistant. The Gullies Will Be Suitable For A Discharge Rate Of .....Lit .Sec. Art. No:---- , Ro For Drinking Water - Ro Of 500 Litres / Hour Permeate Capacity Reverse Osmosis Plant. The Application Of Treated Water Shall Be Pure Drinking Water. The Plant Must Include Neccesary Pre-Filters, Membranes, Casings, High Presure Pumps, Back Flush Arrangements, Valves, Piping, Starter Panel With All Protections Etc Complete. , Storage Tank For Drinking Water - 1000 Ltrs. Ss Water Tank For Drinking Water Storage, Tank Shall Be Provided With Inner Layer Ss316 + Outer Layer Ss 304 / Aluminium Cladded Of Specified Thickness, Tank Should Be Provided With Inlet, Outlet And Vent/Overflow Connection, 50Mm Puf Insulation , Angle Stiffeners,Stand Leg,Ss Flanges Connecting From Water Treatment Facility And Distribution System,Manhole Cover Etc. Complete.(Thicknessof Inner Layer 0.8Mm &Outer Layer .6Mm) , Ro Chiller - 5 Ton Water Chiller With Refrigeration Emersion Compressor, Air Cooled Condenser, Fan Motor Phe Based Powder Coated Body With Drier Filter, Expansion Valve, Refrigeration Copper Line Temp Controller, All Electrical Accessories, Refringent Gas Water Pump With Internal Water Connection, Etc Complete. , Ro For Dialysis - Supply, Installation, Testing And Commisioning Of 500 Litres / Hour Permeate Capacity Reverse Osmosis Plant. The Application Of Treated Water Shall Be Artificial Kidney Dialysis. The Cost Of Plant Must Include Neccesary Pre Filters, Membranes, Casings, High Presure Pumps, Back Flush Arrangements Etc Complete. The Storage Tank For Permeate Water Should Be 1000 Litres Made Of Stainless Steel Low Carbon With All Neccesary Sleeves , Re-Circulation Pump - Hot Water Return Lines Ystempump With Auto Panel Pump Flow 3M3/Hr Head 20 Mtr Power 1 H.P M.O.C. Of Pump Pump Housing Cast Iron ,Impeller Stainless Steel 304Temp Range Up To 90Deg. Control Panel Temperature And Timers Base Control With Digital Display , With All Accessories , A)Fully Automatic Servoline C Buck And Boost Type For Operation On Input Voltage 380-440 V And Output Voltage380-400V Rated For 10Kva Maximum Load And With Voltmeter, , B)Control Panel For Heat Pump For Auto Operation , C)Accessories Like Gaguge, Prv, Temp Sensor , Pex Pipe & Fittings - Supply, Installation, Testing And Commissioning Of Pex Pipes Confirming To Astm F877 And Astm F2023 And De-Zincified, Lead Leached Brass Fittings Of Approved Makes In Following Sizes For Piping Inside Toilets.The Jointing Method Must Be Crimp Ring Jointed, Compression Jointed, Push Fitjointed. The Installation Must Be Carried Out As Per The Standard Procedure Etc Complete As Directed By The Eic. , 1. 15Mm , 2. 20Mm , 3. 25Mm , 4. 32Mm , 5. 40Mm , 6. 50Mm