}

Tender For Road Safety And Signage Work Of Maurawa-Bihar Road(Odr) In District Unnao - Stop Sign -Providing And Fixing Of Retro-Reflectorised Cautionary Mandatory And Informatory Sign As Per Irc :67 Made Of High Intensity Grade Sheeting Vide Clause 801.3 , unnao-Uttar Pradesh

Tender Notice

51998477
Tender For Road Safety And Signage Work Of Maurawa-Bihar Road(Odr) In District Unnao - Stop Sign -Providing And Fixing Of Retro-Reflectorised Cautionary Mandatory And Informatory Sign As Per Irc :67 Made Of High Intensity Grade Sheeting Vide Clause 801.3
Tender
Indian
Uttar Pradesh
Unnao
06-11-2025

Tender Details

Tender For Road Safety And Signage Work Of Maurawa-Bihar Road(Odr) In District Unnao - STOP SIGN -Providing and fixing of retro-reflectorised cautionary mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3 fixed cover aluminium sheeting 1.50 mm thick supported on a mild steel angle iron post 75x75x6 mm firmly fixed to the ground by meens of properly designed foundation with M-15 grade Cement concrete 45x45x50 CM, 60 cm below ground level as per approved drawing.(90 cm Octagonal) 2 Maximum Speed Limit: Providing and fixing of retro refflectonsed Cautonary mandatory and informaatory sign as per IRC 67 mad of high intensity grade sheeting vide clause 801.3 fixed cover aluminum sning. 1.5 mm thick supported on a mild steel angle iron post 75 mm * 75 mm *6mm firmly fixed to the ground by means of propariy dsignd foundation with m-15 grade cment canc 45cm *45cm60cm, 60cm below ground level as per approved drawing. (60 cm circular) 3 Caution Board: Providing and fixing of retro refflectonsed Cautonary mandatory and informaatory sign as per IRC 67 mad of high intensity grade sheeting vide clause 801.3 fixed cover aluminum sning. 1.5 mm thick supported on a mild steel angle iron post 75 mm * 75 mm *6mm firmly fixed to the ground by means of proparly dsignd foundation with m-15 grade cment canc 45cm *45cm60cm, 60cm below ground lvel as per approved drawing. (90 cm quilaterial triangle) 4 HAZARD MARKER:Providing and fixing of retro refflectonsed Cautonary mandatory and informaatory sign as per IRC 67 mad of high intensity grade sheeting vide clause 801.3 fixed cover aluminum sning. 1.5 mm thick supported on a mild steel angle iron post 75 mm * 75 mm *6mm firmly fixed to the ground by means of propariy dsignd foundation with m-15 grade cment canc 45cm x 45cm x 60cm, 60cm below ground lvel as per approved drawing.(Size-30cmx90cm) 5 Informatory Board : Providing and fixing of retro refflectonsed Cautonary mandatory and informaatory sign as per IRC 67 mad of high intensity grade sheeting vide clause 801.3 fixed cover aluminum sning. 1.5 mm thick supported on a mild steel angle iron post 75 mm * 75 mm *6mm firmly fixed to the ground by means of proparly dsignd foundation with m-15 grade cment canc 45cm *45cm60cm, 60cm below ground lvel as per approved drawing. (90 cm quilaterial triangle) 6 Centre Line & Edge Line : Providing & laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC: 35 The finished surface to be lever, uniform and free streaks & holes. 7 REPEATED BAR: Providing and laying of hot applied thermoplastic compound 5.00 mm thick including reflectorising glass beads @250 gms/sqm area as per IRC 35 8 CRASH BARRIER: Providing and erecting a W metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level. all steel parts and fragments to be galvanised by hot dip processs. all 9 6M Span over head Cantilever Structure with 300 dia MS one vertical post: Supply, fixing & eraction of built up Cantilever Structure 6 m span comprising of one vertical posts of 6.00 M height made up of 300 mm NB heavy class MS pipe as vertical member welded with 10 mm MS plate at top & 12 mm M S plate at bottom. The horizontal Truss shall comprise of 50 mm dia heavy class M.S pipe and 40 mm dia heavy M S pipe as bracing & 10 mm MS plate at bottom for fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant. The work includes construction of RCC Foundation of size 0.90x0.90x1.50 m of required depth as per site condition for built up structure including Earth work in excavation 100 mm thick Lean Concrete in 1:35 cement coarse sand and 40 mm gauge stone ballast. RCC withand 1.24 cement coarse sand and 20 mm stone grit including supply and foxring of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering. The lateral vertical clearances and complete Installation work shall be as per relevant clauses of MORT&H specification section 800 and IRC 67 2010 complete in all respect The Rates shall include cost of design fabrication, supply. transportation, Local shifting Erection of Signage structure using crane, inclusive of all taxes etc. all T&P machine, material and labour required for proper completion of work as per direction of Engineer-in-charge. 10 Retro Reflective Sheet:Retro Reflective Signs (Type -IV Sheet). for both side Providing and fixing retro-reflective signboards comprising of customised modular PU Epoxy Coated MS angle iron frame work, almunium composite panel (ACP) as base board, micro prismatic retro-reflective sheet and electro cut coloured overlay film latex printing The horizontal and vertical members including inclined outer members of the MS frame module shall be made of pair MS angle iron No panel size shall be more than one Sam and each panel shall be braced diagonally (one way only) with MS angle The MS frame module shall have lend not more than 3 mtr. The aluminum composite panes (AGP) shall have a thics of 4mm with 0.5mm thick Sam skin of aluminium on both sides The ACP shall be fixed on the MS frame with pup riveting or with self taping SS screws 5mm dia spaced not more than 300mm centre to centre ensuring that no riveting is seen on either face of the frame. On the front visible face of the ACP micro prismatic retro-reflective sheet conforming to Type-IV of ASTM D 4956-09 shall be pressure foxed the retro reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67 2012 & proof of the same in form of government report shall be uploaded while quoting tender The

Key Value

Document Fees
INR 2715 /-
EMD
INR 523000.0 /-
Tender Value
INR 64 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail