|
| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 2 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 3 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 4 | For thickness of tiles 10 mm to 25 mm |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 6 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) |
| 8 | 250x16 mm |
| 9 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 10 | 250x10 mm |
| 11 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 12 | 125 mm |
| 13 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing the joints with white cement mixed with pigment of matching shade complete. |
| 14 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 15 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 16 | Size of Tile 600 x 600 mm |
| 17 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 18 | (i)Single socketed pipes. |
| 19 | 75 mm diameter |
| 20 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 21 | 1:4 (1 cement: 4 fine sand) |
| 22 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. |
| 23 | Old work (one or more coats) |
| 24 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 25 | One coat. |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 27 | One or more coats on old work. |
| 28 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : |
| 29 | Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. |
| 30 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 31 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 32 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : |
| 33 | W.C. pan with ISI marked white solid plastic seat and lid |
| 34 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : |
| 35 | Flat back wash basin of size 550x400 mm. |
| 36 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 37 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. |
| 38 | 20 mm nominal outer dia .Pipes. |
| 39 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work |
| 40 | 25 mm nominal outer dia. Pipes. |
| 41 | 32 mm nominal outer dia. Pipes. |
| 42 | 40 mm nominal outer dia. Pipes. |
| 43 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 44 | 30 cm length |
| 45 | 15 mm nominal bore |
| 46 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 47 | 100 mm diameter |
| 48 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includesmaking necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. |
| 49 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : |
| 50 | 15mm nominal bore |
| 51 | Providing and fixing PTMT grating of approved quality and colour. |
| 52 | Circular type. |
| 53 | 100 mm nominal dia. |
| 54 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 55 | 15 mm nominal bore, 105 mm long. Weighing not less than 138 gms. |
| 56 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 57 | 75 mm average thickness |
| 58 | 50 mm average thickness |
| 59 | 25 mm average thickness |
| 60 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 61 | Bars above 12 mm diameter |
| 62 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 63 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 64 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. |
| 65 | Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 66 | 12 mm average thickness. |
| 67 | 25 mm average thickness in 2 layers. |
| 68 | 50 mm average thickness in 3 layers. |
| 69 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/ lugs/ SS dash |
| 70 | fasteners of required dia and length complete as per direction of Engineer-In- Charge. |
| 71 | (M.S hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/ window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variationin profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 72 | Frame size 65 x 100 mm |
| 73 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. |
| 74 | (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 75 | 30 mm thick |
| 76 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain white color board for backing of cup boards and bathroom/kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel screws etc. all as per direction of Engineer-In- Charge. (Note: stainless steel screws shall be paid separately) |
| 77 | 12 mm thick |
| 78 | Providing and laying waterproofing treatment over the existing roof as directed by E-I-C consisting of: |
| 79 | Cleaning and washing of the surface of existing roof to make it free from dust, oil, grease and loose particles by brushing properly exposing rugged surface and final washing. |
| 80 | Surface cleaning and crack filling: Repairing the damaged surface with Terroza ready plast, widening and deepening of cracks and fill all cracks by terraoza crack filler overlapping 25 mm on either side. |
| 81 | Moisturing the surface and application of Terroseal evenly over the surface to penetrate deep inside the poresand create elastomeric film over it. |
| 82 | Application of heavy duty reinforced glass fibre net (Terromesh) of high tensile strength and alkali resistance over the surface covering vertical side walls. |
| 83 | Application of second coat Terroseal uniformly over the Terromesh. |
| 84 | Application of Terroza water proofing compound with water and terroseal over the surface with roller or trowel like gurmala plaster to form a hydrophobic barrier for water and insulate the surface from heat and cold. |
| 85 | After complete drying of surface application of Terroza building guard in two or more coats with brush or roller and allow it to dry completely to seal the surface in all respect. |
| 86 | The contractor has to check/maintain the water tightness of the treated roof for 5 years. |
| 87 | Cutting of GI pipe and making long threads at site. |
| 88 | 20mm GI pipe |
| 89 | 25mm GI pipe |
| 90 | Providing and fixing ISI marked Stainless steel butt hinges fixed by welding/screws to T-iron frame/chowkhat etc. complete of size:- |
| 91 | 100x70x2.5mm |
| 92 | Providing and fixing C.P. brass L Bend mixer of approved quality make (Jaquar |
| 93 | 15 mm nominal bore. |
| 94 | Provision of box hinges to existing section windows, in place of existing top and bottom corner hung window panel, fixed by welding, cutting etc. wherever required at all heights, all complete as per direction of Engineer-in-charge. |
| 95 | M S Box hinges 50mm high made with 3mm sheet |
| 96 | Providing and fixing C.P. brass pillar tap (quarter turn) operation of standard weight, approved quality and make. |
| 97 | 15 mm nominal bore. |
| 98 | Credit for recovered CP brass fittings |
| 99 | Engaging Carpenter |
| 100 | Engaging Helper |