Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-11-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-12-2025 |
| 2 | 14-11-2025 | Amendment to tender documents and BOQ | BOQ | 25-11-2025 |
| 3 | 10-11-2025 | Date amendment | Date | 25-11-2025 |
| Sl. No. | Item Description |
| 1 | Excavating in post holes (or similar holes) in soft/loose soil each n.exc 0.5 cum, getting out and removing surplus soil to a distance n.exc 50m and making good surface, complete all as specified and directed. |
| 2 | Surface dressing in soft / loose soil not exceeding 15cm deep, complete all as specified and directed. |
| 3 | M&L for hardcore broken stone or boulder of gauge n.exc 63mm deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 4 | M & L for PCC 1:4:8, type D-2, using (40mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 5 | M&L for cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) in columns, pillars etc, complete all as specified and directed. |
| 6 | M&L for 75mm thick cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of floor etc, complete all as specified and directed. |
| 7 | M&L for 40mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in sub base of floor etc, complete all as specified and directed. |
| 8 | S&F glass dividing strips 38 mm wide and 3mm thick and inserted in position to confirm to design, complete all as specified and directed. |
| 9 | Demolition of brick work as in walls/parapet wall,s removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces, complete all as specified and directed. |
| 10 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc 6 m mean radious built in cement mortar 1:6, complete all as specified and directed. |
| 11 | All as per above item No 10 above but except bricks (old brick obtained from demolition shall be used). |
| 12 | M&L for 15 mm thick cement mortar 1:4 on Brickor concrete surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 13 | M&L for prepration of newplastered surfaces of wall and applying two coat of cement base paint over a coats of alkali resistant priming plastered and other surfaces, complete all as specified and directed. |
| 14 | S&F pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering/clading to wall, fixed with self taping screws, complete all as specified and directed. |
| 15 | S & F mild steel plates(Plain or chequered) channel square cut or notched (ordinary and counter sunk) forming holes, sithout any attachment for Fe-410-W(Gde E 250 quality B), complete all as specified and directed. |
| 16 | S & F Framed work as in tubular posts roof trusses, purlines, rafters etc made of tubes (square circular oval or any other shape or section as directed) including all necessary fittings, nut bolts, threading or welding etc as required, complete all as specified and directed. |
| 17 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applyingtwo coats of synthetic enamel paint over over a coat of red oxide primer, complete all as specified and directed. |
| 18 | S&F 4.8 mm thick sheet glass selected quality plain/ tinted in squares exc 0.5 sqm each pane, complete all as specified and directed. |
| 19 | S&F Powder Coating aluminium frame for doors, windows,(minimum thickness of powder coating 50 micron) ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and directed. |
| 20 | S & FPowder coated aluminium door shutters, aluminium sectionweighing 0.55 kg/ m including necessary joining cleats, zing clips, ruber neoprene packing, handles 2 Nos ineach door,tower bolt, hinges, anodised aluminium snap beading screwscomplete all as specified (minimum thickness of powder coating 50 micron), complete all as specified and directed. |
| 21 | S&F 600X600X12 mm interlocking eva foam flooring rubber tiles for gym having non slip surface, water proof, complete all as specified and directed. |
| 22 | Taking down cement plaster on brick wall/ concrete surfaces of any description/ thickness including raking out joints hacking for key scrubbing down with water, complete all as specified and directed. |
| 23 | S&F providing precast cement concrete louvers and jallies 45mm thick (measured solid) including all mouldings but excluding frame (pre-cast frame shall be measured seperately) setting in CM 1:4 precast cement concrete jalli type B0 1:2:4 (12.5mm graded aggregate), complete all as specified and directed. |
| 24 | M&L for 15 mm thick cement mortar 1:4 including WPC on Brickor concrete surface finished even and smooth without using extra cement, complete all as specified and directed.Note : WPC will be measured and paid separately. |
| 25 | M&L for complete removal of old decorated plastered & unplastered surfaces of wallsby brooming down or steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts, trading oil and greasy spots applying two coat of cement base paint over a coat of primer plastered and surfaces, complete all as specified and directed. |
| 26 | Taking down chowkhats or frame with shutter w/o taking off shutter from the frame areaexc 1.5 Sqm but n-exc4 sqm each, complete all as specified and directed. |
| 27 | Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area not exc 1.5 Sqm each, complete all as specified and directed. |
| 28 | S & FPowder coatingaluminium window and ventilator shutters,side hung/fixed type without sash bars,aluminium sectionweighing 0.55 kg/ m including necessary joining cleats, zing clips, ruber neoprene packing, anodised aluminium snap beading screwsanodised aluminium fittings such as peg stay, Tower bolt 150mm long 1 No. hinge type B-21 100 mm long 2 Nos, suitable handle 1 No complete all as specified and as directed (minimum thickness of powder coating 50 micron), complete all as specified and directed. |
| 29 | Supply and fixing Anodised aluminium grill (anodised tranparentor dyed to required shade according IS : 1868/ pattern, with approved standard section and fixed to the existing window frame with CP brass stainless steel screws @200 mm centre to centre including cutting the grill to proper opening size for fixing and operaton of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed. |
| 30 | S&F 4.8 mm thick sheet glass selected quality plain/ tinted in squares exc 0.5 sqm each pane, complete all as specified and directed. |
| 31 | S&F 12mm thick pre-laminated particle board, interior grade, prelaminated both side with decorative choice lamination and fixed with screws to aluminium door, complete all as specified and directed. |
| 32 | S&F stainless steel wire cloth 0.36 mm nominal dia and average width of aperture 1.40 mm and fixed with SS wire staples, complete all as specified and directed. |
| 33 | S&F 300 mm long aluminum anodised sliding door bolts ,Aluminium alloy,door bolt with hasp,staple (bolt type) and fixingclips of sheet, cast or extruded sections and fixing bolts andsliding bolts of extruded sections or cast-aluminium, complete all as specified and directed. |
| 34 | S&F Floor doors stoppers of aluminium alloy body and tenque anodisede with hard drawn steel spring fixed in floor 150mm long, complete all as specified and directed. |
| 35 | S&F aluminum (Die cast) body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kgand fixed, complete all as specified and directed. |
| 36 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 37 | M&L Non skid jointless cerermic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm, in neatcement slurry and pointed in white or coloured cement with pigment over and including 15 mm thick screed bed in cement motar 1:6, complete all as specified and directed. |
| 38 | All as per above item No 37 above but in vertical surfaces as Dado/Skirting over and including rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 rough finished surfaces to receive tiles. |
| 39 | M&L for surface excavation in soft/ loose soil n.exc 30cm deep and averaging 15cm deep and getting out, complete all as specifide and directed. |
| 40 | M&L for chequered cement concrete tiles rubber finish 30 cm x 30 cm x 25mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement and pigments over & including 20mm thick screed in cement mortar 1:6, complete all as specified and directed. |
| 41 | Dismanling Stone slabs and tiles of laid bedded and pointed in any mortar any description or thickness in floors, aprons etc, complete all as specified and directed. |
| 42 | M&L for granite slab (of any type) 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 15mm thick screed bed of cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to matchthe shade of granite, complete all as specified and directed. |
| 43 | M&L for granite slab (of any type) 20mm thick (table rubbed and polished) for wall lining (veneering to wall ) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2)using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed. |
| 44 | M&L for Dholpur stone 16-18mm thick cladding gang saw cut with machine cut edges, uniform colour of each stone size exceeding 0.25 sqm area and not exceeding 0.5 sqm fixed with and including one number SS clamps (grade 202) of flat 30mm X2mm ,150mm long made to shape on each slab,V groove making at top and bottom of stone and drilling hole for holder fastener, polishing , rubbing and including silicon treatment, complete all as specified and directed. |
| 45 | M&L for rounding to edges of stone slabs one edge, such as in steps,cooking platform, and other similar situation, complete all as specified and directed. |
| 46 | M&L for cement concret 1:3:6 type C-2 for 150mm drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 47 | S&F 150mm dia reinforced cement concrete pipes, class NP3, laid and jointed complete with collars, complete all as specified and directed. |
| 48 | M&L Hardcore broken bricks of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed. |
| 49 | M&L Providing, cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as inMH kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed. |
| 50 | Supply only integral water poofing compound, complete all as specified and directed. |
| 51 | S&F mild steel TMT bar 10 mm dia and above cut to length bent to shape required including cranling, bending spirally for hooping for column,hooking ends and binding with mild steel wire not less than0.9mm dia, completeall as specified & directed. |
| 52 | M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as inCoping including form work and finishing, completeall as specified & directed. |
| 53 | M&L providing pre cast cement concrete (1:2:4) type B1 using 20 mm graded stone agg as in cover slab and similar work and set in cement mortar 1:4 includingnecessary formwork, completeall as specified & directed. |
| 54 | Removing excavated materials (soil), not exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point, complete all as specified & directed. |
| 55 | Returning, filling in, including spreading levelling, watering and well ramming in layer not exc.25 cm thick in soft or oose soil and getting out, complete all as specified & directed. |
| 56 | M&L for cutting holes in brick walls in mud mortar for inserting MH pipe and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required exc one brick but not exc two bricks, complete all as specified & directed. |
| 57 | M&L Glazed ceramic colouredtiles (300x450mm) x6-7mm thick on vertical surfaces as in skirting/dado, set and jointed with neatcement slurry and pointed in white/coloured cement to match the shade of tiles over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed. |
| 58 | M&L Non skid jointless cerermic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in neatcement slurry and pointed in white or coloured cementwith pigment over and including 15 mm thick screed bed in cement motar 1:6, complete all as specified and directed. |
| 59 | M&L for 25mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in floor, complete all as specifide and directed. |
| 60 | S&F PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube fixing in opening as per specification & drawing all as specified and directed. |
| 61 | S&F factory made soild panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed togehter with solvent cement, supplying & fixing in the frame at site as per specification, complete all as specified and directed. |
| 62 | S&F 100 mm size butt hinges medium weight cold rolled mild steel, complete all as specified and directed. |
| 63 | S&F Aluminium handles cast type anodised 150mm long, complete all as specified and directed. |
| 64 | S&F Aluminium anodised barrel tower bolts of extruded section and fixed 200 mm long, complete all as specified and directed. |
| 65 | S&F 15mm bore stop cock fancy type chromium plated with long shank and cup concealed type, complete all as specified and directed. |
| 66 | S&F 15mm bore bib tap cast copper alloy fancy type CP with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 67 | S&F15mm bore Pillar taps fancy type, cast copper alloy, with capstan heads,chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed. |
| 68 | S&FPVC connection 600 mm long, 15mm size with PTMT nuts, complete all as specified and directed. |
| 69 | S&F10 ltr PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle with flush pipe, complete all as specified and directed. |
| 70 | S&F brass chromium plated tubular towel rail 20mm dia (D) type 60cm long between flanges, complete all as specified and directed. |
| 71 | S&Fglass shelf bathroom corner having radius 300mm min incl fixing arrangement, complete all as specified and directed. |
| 72 | \"S&F PVC bathroom cabinet with mirror size 350mm x 450mm, complete all as specified and directed. |
| 73 | S&F Health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipes with 1.25 mtr long flexible tube and ABS wall hook incl making connections and fixed in position, complete all as specified and directed. |
| 74 | S&F vitreous china pedestal stand white colour suitable for wash hand basin, complete all as specified and directed. |
| 75 | S&Fvitreous china wash downwater closetpedestal pattern pan white withtrap including connection to existing out joint pipe, flushing pipeor Cistern, antisyphonage pipe, including making, etc complete including making goood to floor etc, complete all as specified and as directed. |
| 76 | S&F stainless steel grating 100mm dia over floor trap, complete all as specified and as directed. |
| 77 | S&F 500 ltr rotational moulded polyethelene water storage tank (cylindrival vertical with closed top) tripple layer, white in colour including 20mm ball valve and fixed in position, complete all as specified and as directed. |
| 78 | S & F CPVC pipe outer dia 25mm SDC 11 & plain CPC SDR 11fittings in trenchescomplete etc fixed to walls, floors & ceilings including cuttings and chases, complete all as specified and directed. |
| 79 | S & F CPVC pipe outer dia 32mm SDC 11 & plain CPC SDR 11fittings in trenchescomplete etc fixed to walls, floors & ceilings including cuttings and chases, complete all as specified and directed. |
| 80 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints, step clamps, including all fittings (any type of \"T\"/tee ,bend,Y, Branch piece single/double, reducer , vent coil, access door, junction single/double, equal/unequal , any type of trap etc) 75mm dia fixed to walls/floor/trenches etc, complete all as specified and directed. |
| 81 | All as per Srl item No 80 here in before but for 110mm dia pipes, complete all as specified and directed. |
| 82 | Providing and laying bitumen mastic wearing course 40 mm thick (as per latest IS 13026 : 1991 specifications) with industrial bitumen of grade 85/25 conforming to IS : 702, prepared by using mastic cooker and laid to required level and slope, including providing antiskid surface with bitumen precoated fine grained hard stone chipping of approved size at the rate of 0.005 cum per 10 sqm and at approximate spacing of 10 cm centre to centre in both directions, pressed into surface protruding 1 mm to 4mm over mastic surface, including cleaning the surface, removal of debris etc (Considering bitumen using 10.2% as per MORTH specification)., complete all as specified and directed. |
| 83 | Demolition of cement concrete (unreinforced) in ground floor and paving not exc 15cm thickness below or above ground level, including removing the debris outside the MOD land, complete all as specified and directed. |
| 84 | M&L for 15 mm thick cement mortar 1:6 on Brickor concrete surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 85 | M&L rendering 5 mm thickon fair faces of ceiling incement mortar 1:3finished surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 86 | M&L for Preparation of newlyplastered wall surfaces and applying three coats of white washing, complete all as specified and directed. |
| 87 | M&L for Preparing old decorated surfaces of walls including brooming down or steel wire brushing scrapping down smoke soot,, moulds, moss and efflorescent salt and trading oil and greasy spots and applying two coat of white wash on walls, complete all as specified and directed. |
| 88 | M&L for preparation of oldplastered surfaces and applying one coats of cement base painton walls, complete all as specified and directed. |
| 89 | M&L prepration of new surfaces of and applying three coat of white wash on ceiling, complete all as specified and directed. |
| 90 | S&F in repair stainless steel wire cloth 0.36 mm nominal dia and average width of aperture 1.40 mm and fixed with SS wire staples, complete all as specified and directed. |
| 91 | M&L for prepraration of old painted on steel or iron surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 92 | Preparation of old decorated plastered & un plastered surfaces of walls by brooming down or steel wire brushing, scraping down smoke root mould moss and efflorescent salts trading oil and greasy spots filling holes cracks with wall care putty all and applying one coat of whitewash on ceiling, complete all as specified and directed. |
| 93 | M&L providing pre cast cement concrete (1:2:4) type B1 using 20 mm graded stone agg as in cover slab and similar work and set in cement mortar 1:4 includingnecessary formwork, complete all as specified and directed. |
| 94 | M&L vitrified ceramic coloured tiles 10 mm thick (Square/rectangular) area of each tile exc 0.36 Sqm but n.exc 0.42 Sqm ( Double charge) in floorneatcement slurry and pointed in white or coloured cementwith pigment over and including 15 mm thick screed bed in cement motar 1:6, complete all as specified and directed. |
| 95 | All as per above item No 94 above but as in skirting, dados/Vertical surfaces and rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 rough finished surfaces to receive tiles. |
| 96 | S&F stainless steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tined tacks or galvanised wire staples, complete all as specified and directed. |
| 97 | S&F stainless steel pipe, grade 304 for ramp hand rail complete as per requried at site, complete all as specified and directed. |
| 98 | M&L for 75 mm thick PCC 1:3:6 type C2 (Using 40mm graded stone aggregate) as in plinth protection/floor sub base etc., complete all as specified and directed. |
| 99 | M&L 25mm thick PCC 1:2:4 type BO using 12.5mm graded stone aggregate as in floor to receive tiles, complete all as specified and directed. |
| 100 | Excavating in trenches not exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sq m on plan and n exc 1.5 m in depth and getting out as specified and directed. |
| 101 | S&F MS angle iron posts and struts in fencing including cutting top to shape as directed drilling holes welding and notching for wire etc and flat iron fillets for securing wire mesh including bedding or riveting etc conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 102 | Fixing only Chain link fencing including line wires, any mesh, size and type to any type of standerd, rails, straining bolts, etc including provision of binding wire, complete all as specified and directed. |
| 103 | Supply only chain link MS galvanised fencing of mesh size 80 mm x 80 mm dia of wire 4mm, complete all as specified and directed. |
| 104 | Supply and fixing 10mm dia mild steel Square bars(straight or cambered)/round bars or similar items such as bars for tightening of chain link fencing, complete all as specified and directed. |
| 105 | S&F mild steel screw bolts ( machine made) with hexagonalheads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut not exc 5cm and dia of shank 10mm, complete all as specified and directed. |
| 106 | S&F steel work as in Square Hallow section trusses (framed work) incl rafters, purlines, distence pieces, cleats, post for trusses, special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS including structural steel is painted one shop coat of zinc chromate primer paint (including preparation of surface), complete all as specified and directed. |
| 107 | S&F of mild steel work as in grills, gratings etc. such as frame work of wall guard bar, angle iron in door frames, barred iron door,grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work and similar work etc; confirming to Fe-290 Gde E-165 including cutting and welding as required, complete all as specified and directed. |
| 108 | M & L for machine pressed precast concrete interlocking paver block any shape and size cofirming to IS 15658-2006 of 60mm thickness, M35 grade with grey cement and no pigments interstices all as specified over and including 100mm thick PCC 1:4:8 (type D-2 using 40mm graded stone aggregate) over 100mm thick hardcore, complete all as specified & directed. |
| 109 | M&L 30mm thick sand cushion under pavers, floors or in foundations including watering and consolidation, complete all as as specified and directed. |
| 110 | M&L for providing cement concrete type B-0 1:2:4 (12.5mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating,complete all as specified and directed. |
| 111 | M&L Brickwork with sub class \"B\" Bricks, Straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4, complete all as specified and directed. |
| 112 | M&L for cement concrete 1:4:8 type D-2, bore dia 100mm for bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 113 | M&L 12mm thick cement plastering in cement mortar (1:6) on other thanfair faces of brick work or concrete surfaces finished even & smooth without using extra cement, complete all as specified and directed. |
| 114 | Extra for forming fair finished drain or channel 30 cm inner girth in cement bconcreteusing extra cemnt including forms moulds, mitred/ stoped ends, complete all as specified and directed. |
| 115 | M&L for applying two coat of distemper oil emulsion over a coat of primer and one coat of wall care putty incl preparation of new plaster surface, complete all asspecified and directed. |
| 116 | M&L applying 3 mm thick wall care putty on wall using sand paper before applying priming coat, complete all as specified and directed. |
| 117 | M&L for preparation of newly plastered surface of walls including corners and applying two coats of 100% Premium exterior acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm, complete all as specified and directed. |
| 118 | S&F PVC (SWR) bends 110 mm dia, complete all as specified and directed. |
| 119 | S&F Tube \"medium grade\" galvanised, with all fitting and fixed complete to walls and ceiling etc 20mm bore, complete all as specified and directed. |
| 120 | S&F in stop valves 20mm, cast copper alloy, screwed down, high pressure with crutch or butterfly handle etc, complete al as specified and directed. |
| 121 | S&F Stop valve/angle cock cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe of bore 15mm fixed, complete all as specified and directed. |
| 122 | S&Fgrating square fittings 150mm size of PTMT (minimum wt-100 gms), complete all as specified and directed. |
| 123 | S&F Tube \"medium grade\" galvanised, with all fitting and fixed complete to walls and ceiling etc 15mm bore, complete all asspecified and directed. |
| 124 | S & F factory madeBox type steel window, double shutter (glazed and wire gauzed) with side hung shutters including box type hinges, steel handles fabricated type for each leaf duly welded, mild steel barrel tower bolts 150mm size (02 Nos for each leaf) duly welded, complete with glazing bars dovetailed or welded including MS fillets, including provision and welding of 12 mm dia square guard bars in 150mm spacing c/c including one shop coat of red oxide primer over window, frame & guard bars complete all as specified and directed. Notes: -(i) Glazing & Wire cloth shall be measured and paid separately.(ii) The term double shutter stated is meant for providing glazed shutter as well as wire gauged shutter on outside & inside of the frame respectively. |
| 125 | S & F factory made Plain, framed, panelled shutters, 35mm thick, 2nd class hard wood , plain, framed, panelled shutters (any number of panels), with panels of 9mm thick veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and directed. |
| 126 | S&Ffactory made pressed steel frames made out from 1.25mm thick steel sheetfor doors of size 105x60 mmwith one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.and including treated with tar or coal tar black paint on steel surfaces in contact / embeded in concrete or masonary work including Filling hollow portion of frame with PCC 1:3:6 type C-1, complete all as specified and directed. |
| 127 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqmin each pan complete all as specified and directed. |
| 128 | M&L for preparation of new wooden surfaves and applying 2 coats of synthetic enamel paint over a coat ofpink primeron new wooden surface of girth over 10 cm,complete all as specified and directed. |
| 129 | S&F bib taps long body, CP cast copper alloywith crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 20 mm boreand fixed, complete all as specified and directed. |
| 130 | S&Frotational moulded water storage tank (cylinderical vertical with closed top ) hoisted and fixed in position capacity 2000 lts tank tripple layer, white in colour with 25mmball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball (Minimum weight 210 gms)along with 20mm tank nipple and reducers, complete all as specified and directed. |
| 131 | M&L for 20-25mm thick machine cut kota stone slab flooring over 20mm thick cement screed base of cement mortar 1:6 laid and jointed with grey cement slury mixed with pigment to match the shad of slab including grinding and polishing 5mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 132 | All as per item No 131 above but as in skirting /dado with 10 mm thick rendering in cement mortar 1:4. |
| 133 | M&L for preparation of old decorated plastered & unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smaoke soot, mould, moss and efflorescent salts trading oil and greasy spots; filling holes, crakes with wall care putty and applying one coat of cement paint, complete all as specified and directed. |
| 134 | M&L for preparation of old decorated plastered & unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smaoke soot, mould, moss and efflorescent salts trading oil and greasy spots; filling holes, crakes with wall care putty and applying onecoat of distemper oil emulsion (White/ Tinted/ Ivory) on the surface of walls complete all as specified and directed. |
| 135 | Preparation of old decorated plastered & unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smaoke soot, mould, moss and efflorescent salts trading oil and greasy spots; filling holes, crakes with wall care putty and applying one coat of white wash on ceiling, complete all as specified and directed. |
| 136 | M&L 4mm dia galvanised steel wire mesh of square or rhombus shape net for bird proofing and fixing as per the ground requirement below shed or any other locations, complete all as specified and directed. |
| 137 | Providing precast cement concrete type C-0 1:3:6 (12.5mm graded stone aggregate) louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame (Pre cast frame shall be measured separately if used) set in cement mortar 1:4, complete all as specified and directed. |
| 138 | Formwork to fins, louvers, fascia including props in sides and soffits, complete all as specified and directed. |
| 139 | M&L 100mm thick PCC(1:2:4) type B1,(using 20mm graded stone aggregate) finish even and smooth with using extra cement, complete all as specified and directed. |
| 140 | S & F anodised aluminium snap grid frame work for false ceiling, size of grid 605x605mm including hangers 6mm dia GI (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI, flat 40 x 3 mm size 60mm long and expansion hold fastners 12.5mm dia, 40mm long, complete all as specified and directed. |
| 141 | S&F 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh, complete all as specified and directed. Note :-Fillets, metal frame work and G.I. wire mesh shall bemeasured and paid separately. |
| 142 | S&F solid PVC wall linning consisting of 5mm thick wood grain printed PVC Sheet inclusive of solvent cemnt and fixing at site on PVC Frame as per specification and drawing, complete all as specified and directed. |
| 143 | S&F aluminium powder coated (min thickness of powder coating shall be 50 micron) window and ventilator withside hung shutters with sash bars, section weight 0.55 kg/RM, necessary jointing cleat glazing,clip,handles CP hinges, tower bolts etc packing,anodised snap beading, screws, complete all as specified and directed. |
| 144 | M&L for 5.5mm thick sheet glass, selected quality and glazing with aluminium beading in square n exc 0.5 sqm. in each pane, complete all as specified and directed. |
| 145 | All as item No-144but 5.5 mm thick glass obscured or frosted on one side in panes each exc. 0.5 sqm. |
| 146 | S&F aluminium (extruded section body) door closer hydraulically regulated, designation No 3 universal type suitable for door shutter of 851 to 1000mm in width, complete all as specified and directed. |
| 147 | S&F 100mm, 4 levers, aluminium mortice lock vertical type, complete all as specified and directed. |
| 148 | S&F 140mm, Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed. |
| 149 | M&L for 40mm thick damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete 1:2:4, type B-0, complete all as specified and directed. |
| 150 | S&F PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and directed. |
| 151 | S&F MS TMT bar 6 to 8mm dia and over cut to length bent to shapes requried including cranking bending spirally for hooping for columns ,hooking ends and bindings with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. |
| 152 | All as ser item No 151 above but 5mm dia and over upto and including 6 to 10 mm dia in stirrups, spacers and binders etc complete all as specified and directed by Engineer-in-Charge |
| 153 | M&L for Reinforced cement concrete (nominal mix) in type B-1 1:2:4 (Using 20mm graded stone aggregate) in beams, cantilevers, bressummers,lintels over 1.5m span, complete all as specified and directed. |
| 154 | M&L for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening, the formwork soffit only shall be paid for under item 07010), complete all as specified and directed. |
| 155 | S&F 25 mm dia Harison rails , mild steel , chromium plated withfixing fancy type brass cpbrackets and side knobs , stops ,rollers etc as in curtain rod and fixed to wall, complete all as specified and directed. |
| 156 | M & L for point wiring complete with 1.5 Sqmm PVC insulated and unsheathed FRLS cable single core multi stranded copper conductor, 1100 volts grade drawn through and including PVC casing / capping including copper earth continuity wire ofPVC insulated cable FRLS of size 1.50 Sqmm and connected to common earth dolly with all accessories (gang box for switch socket, ceiling rose box, holder box, tee, bend etc), complete all as specified and directed for the following :- |
| 157 | One ligth point / fan point, bell point controlled by one wayswitch |
| 158 | One Switch socket outlet 3 pin 5 Amps on same board. |
| 159 | One Switch socket outlet 2/3 pin 5 Amps on independent board. |
| 160 | All as per item No.156 here in before but 2.50 Sqmm PVC insulated FRLS, multistranded copper conductor cable 1100 v grade and 2.5 Sqmm PVC insulated FRLS multistranded copper conductor cable 1100 v grade for 3 pin, 5/15 Amps switch socket outlet on independent board. |
| 161 | S&F Switch piano flush type SP one way 5 Amp, complete all as specified & directed. |
| 162 | S&F Switch socket combination piano, flush type, 15 Amps, single pole one way, complete all as specified & directed. |
| 163 | S&F Switch socket combination piano, flush type, 5 Amps, single pole one way, complete all as specified & directed. |
| 164 | S&F ceiling rosesurface bakelite 65 x 50mm two to three terminals, complete all as specified and directed. |
| 165 | S&F regulator step type 300 watt 240 volts for ceiling fan, complete all as specified & directed. |
| 166 | S&F IP-42 protection distribution board, SPN 8 Way, 240 Volts, sheet steel, powder coated, double door system, fitted with two covers suitable for use on 240 V, 50 HZ, with 200 Ampsrated bus bar, neutral link each bar and din rail, complete all as specified and directed. |
| 167 | S&F isolator SPN 6 to 40 Amps, 240 Volts, complete all as specified and directed. |
| 168 | Supply and Fixing MCB SP 6 to 32 Amps 240 volts, 15 Hz, 10 KA suitable for lightening load of capacity 6 to 32 Amps, complete all as specified and directed. |
| 169 | Supply and Fixing Ceiling fan BEE labelling 5 Star Rated Voltage Single Phase, 230 Volts AC Frequency 50HZ Maximum andPower Input 50 Watt and Min air delivery 245 CFM and service value 6.0 andSweep 1400 mm Standard Fittings down rod, Regulator, blades & Accessories Capacitor, double ball bearing, Down Rod, Canopy & other standard accessories for complete fitting of the fan, complete all as specified and directed. |
| 170 | M&L submain wiring with two runs of single core PVC insulated FRLS, unshethed, 1100 Volts grade, multistranded copper conductor cable of size 6 sqmm drawn through and including heavy grade PVC casing caping of suitable size, fixed to walls/floors/ceiling and surfaces on truss by means of saddles and clips etc including all conduit acessories/ fittings/junction box/ inspection covers etc of heavy grade with one run of 6 Sqmm PVC insulated FRLS, unshethed multistranded copper conductor cable as a continuous earth wire, complete all as specified and directed.Note: (a) Two runs of 6 Sqmm single core copper cables and One run of earth conductor cable of 6Sqmm with casing capping/conduit will be measured and paid as one unit length. |
| 171 | M&L earthing with galvanised steel earth plate electrode of size 60cmX60cmX6cm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m bellow normal ground level, connected to the galvanised earth lead by means of bolts, nuts and washers of galvanised iron or steel using GI or steel wire 4.00 mm diaas earthing lead as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on complete including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:2:4 type B-1 using 20mm grade stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI light grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @ 150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh charcoal and common salt inalternate layer of 15cm thick, complete all as specified and as directed. |
| 172 | S&F ceiling light 36 W ultra modern design architectural LED luminaries which provide soft light and glare free symmetrical illumination suitable for grid ceiling 2\" x 2\" bakelite panel, complete all as specified and directed. |
| 173 | S&F LED Batten Tube Light light fittings18 Watt and fixed with wall surface with anodized extruded aluminium housing, high transmissitivity diffuser and high lumin output and connecting with 3 core flexible copper cable PVC insulated, complete all as specified and directed. |
| 174 | M&L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable, complete as specified and directed.Note :- Only punned thickness of sand 18 cm shall be measured and paid. |
| 175 | M & L for well burnt bricks sub class \"B\" as in protection of cable laid dry, flat abutting each other width wise, complete all as specified and directed. |
| 176 | M &L for GI pipe 80 mm dia light grade, for protection of cable fixed in wall or laid in trenches, complete as specified and directed. |
| 177 | Supply, laying and testing of cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 4 core, complete all as specified and directed. |
| 178 | Supply and fixing in repairs GI tube in trenches /walls medium grade, complete with GI fittings and connecting to existing water main, complete all as directed of following size:- |
| 179 | 20mm bore |
| 180 | 25mm bore |
| 181 | 40mm bore |
| 182 | Supply and fixing in replacement gun metal gate valves, with iron whell head, screwed both ends for iron pipe, complete of following size:- |
| 183 | 20mm dia |
| 184 | 25mm dia |
| 185 | 40mm dia |
| 186 | M&L for cutting of GI/CI existing pipe line in position for inserting new Tee branches etc, complete all as directed of following size:- |
| 187 | 150mm bore size |
| 188 | 100mm bore size |
| 189 | Supply and installation of hi wall split unit indoor & Outdoor Complete with all assessories cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2 TR, complete all as specified and directed. |
| 190 | S&F ofVoltage stabliser for automatic operation single phase naturally air cooled indoor type and designed for input variation between 130 V to 300 volt with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 5 KVA, complete all as specified and directed. |
| 191 | S & F sub-main wiring of 2 x 4.0 Sqmm and 1 x 4.0 Sqmm earth wire, PVC insulated un-sheathed FRLS cable multistranded copper conductor with earth wire of 6 Sqmm PVC insulated un-sheathed FRLS stranded copper conductor including PVC conduit, complete all as specified and directed. |
| 192 | Supply and Fixing Single pole and neutral encloser with two pin and earth plug and socket with one single pole MCBs of 32 Amp, complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail