Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-12-2025 |
| 2 | 02-12-2025 | BOQCorrigendumT21 | BOQ | 12-12-2025 |
| 3 | 02-12-2025 | Other Corrigendum 04 | Other | 12-12-2025 |
| 4 | 28-11-2025 | DateCorrigendumT21 | Date | 12-12-2025 |
| 5 | 21-11-2025 | DateCorrigendum02 | Date | 06-12-2025 |
| 6 | 17-11-2025 | Date Corrigendum | Date | 01-12-2025 |
| Sl. No. | Item Description |
| 1 | Building Work |
| 2 | Dismantling of brick tiles or terracing tiles single layer on roofs complete all as specified and directed |
| 3 | Demolition of Mud inroofs any thickness, including plastering and leeping plaster ( whether full thickness removed or only a part thereof ) complete all as specified and directed |
| 4 | Supply, laying and fixing 2 mm thick FOSROC proofex ORG over minimum 200 GSM TPO (Thermoplastic Polyolefin) waterprofing membrance on prepared surfaces of roof and upto 300mm on parapets and cumple joints including junction of roof and parapet of make Geotextile or Asian Paint or any fully compatible material of makes specified here-in-after. Note :-The work of water proofing to roof and sunken portions shall be executed by the manufacturer\"s authorized trained/skilled applicator as per technical guidelines issued by the manufacturer. A MOU is to be executed between the contractor and manufacturer and the same will be got approved from the GE/AGE (I) before commencment of work.The Contractor will arrange to provide company back guarantee for the water proofing work for the period specified here-in-after. |
| 5 | M&L for Cement concrete type B-2 (1:2:4) using 20 mm graded stone aggregateas in roof padding / floor subbase averaging thickness of 50 mm on roof to maintane slope correction of the depresses/ unduation portion over a coat ofneat cement @ 3.0 kg per sqm complete all as specified. |
| 6 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles including mortar of any ratio complete all as specified and as directed. |
| 7 | M&L forBrick work with old size sub class \"B\" bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:4 complete all as specified and as directed . |
| 8 | M&L for Demolition of reinforced cement concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and directed. |
| 9 | Material and labour for reinforcement cement concrete (nominal mix) (1:2:4) type B-1, using 20 mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 10 | M&L for Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 11 | Material and labour for Formwork to sides and soffits ofroof beams, lintels, cantilever, shelves, splay between floor and beam etc., flat fair finished concrete surfaces, complete all as specified and directed. |
| 12 | Taking down cement plaster on brick or concrete surfaces etc including racking out joints hacking for key,scrubbing down with water etc (from walls and ceiling surfaces of any description) & removing debries out side the MoD land to a desiginated place earmarked by the local administration complete all as specified and as directed. |
| 13 | M&L for rendering 10mm thick in cement mortar (1:3) on concrete surfaces as in ceiling,finished even and smooth without using extra cement complete all as specified and as directed. |
| 14 | M&L for rendering 15mm thick in cement mortar (1:4) mixedusing water liquid proofing compound @ 3% by weight of cementfinished even and fair without extra using cement complete all as specified and directed.Note:- WPC shall be measured and paid for separately. |
| 15 | M&L for rendering 15 mm thick in two layers (10+5mm) on concrete surfaces in cement mortar (1:4) in patches at columns, chajja, canpoy and soffits using GI chicken wire mesh of dia 0.71 mm and mesh size 12 mm with &including necessary scafolding as required at site complete all as specified and as directed. |
| 16 | M&Lfor rendering 12 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cementcomplete all as specified and directed. |
| 17 | M&L for preparation of new plastered surfaces as in ceiling and applying three coats of white wash complete all as specified and as directed. |
| 18 | M&L for complete removal of existing treatment and applying two coats of white wash as in ceiling complete all as specified and as directed. |
| 19 | M&L for preparation of newly plastered surfaces of walls and applying two coats of 1st quality water basedAcrylic distemper over and including1mm thick wall care putty to obtain smooth regular/even finish over a coat of primer of the same manufacturer complete all as specified and as directed. |
| 20 | M&L for complete removal of existing treatment on walland applying two coats of 1st quality water basedAcrylicdistemperover and including1mm thick wall care putty to obtain smooth regular/even finish complete all as specified and as directed. |
| 21 | M&L for preparation of newly plastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. |
| 22 | M&L for complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed.Note for item No 1.24 &1.25: Weather proof exterior emulsion paint and primer shall be of same manufacturer. |
| 23 | Supplyonly intergral water profing compound complete all as specified and as directed. |
| 24 | Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed. |
| 25 | M & L for coloured non skid/matt finish ceramic tiles, 7 to 8 mm thick, (square/ rectangular),area of each tile exceeding0.18 sqm but not exceeding 0.38 sqmin floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over andincluding screed bed or bedding layer of 15 mm thick in cement mortar(1:6) complete all as specified and as directed. |
| 26 | All as per item No 1.28 here-n-before but as indado, riser & skirting over & incl 10mm thick rendering in CM 1:4 complete all as specified and as directed. |
| 27 | M & L for coloured non skid/matt finish ceramic tiles, 7 to 8 mm thick, (square/ rectangular),area of each tile exceeding0.11 sqm but not exceeding 0.18 sqm sq.min floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over andincluding screed bed or bedding layer of 15 mm thick in cement mortar(1:6) complete all as specified and as directed. |
| 28 | M&L for coloured glazed ceramic tiles of size 350 x 250 x 7mm /450x350x7 mm thick on vertical surfaces such as skirting/dado, set and jointed in neat cement slurry and pointed in coloured cement to match over andincluding rendering 10mm thick in cement mortar (1:3) complete all as specified and as directed. |
| 29 | M& L 16 to 18 mm thick baroda green marble (of any type) work (table rubbed and polished) in steps, jambs, urinal partitions, pillars, window- cills,cooking platforms and thelike in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshades complete all as specified and as directed. |
| 30 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5sq.m each complete all as specified and as directed. |
| 31 | Taking down chowkats or frames with shutters (without taking off shutter from the frames) exc. 1.5sq.m but not exc. 4sq.m each complete all as specified and as directed. |
| 32 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm thick prelaminated wood grain both side PVC sheetreinforced with MS Square tube, supplying and fixing in opening as per specifications and drg, complete all as specified and as directed. |
| 33 | Supply and fixing factory made pre-laminated PVC door shutter (confirming to IS-4020) 30 mm thick consisting of frame made out of MS tubes of 19 gauge thickness & size of stiles, top rail, bottom rail & lock rail all as per shown on drawings in SSRPart II, MS frame shall have a coat of steel primer of approved make & manufacturer, MS frame covered with 5mm thick heat moulded pre-laminatedPVC \"C\" channel of size 30mm thick, 70mm width out of which 50mm shall be flat & 20mm shall be tapered in 45 degree on the either side forming stiles and 5mm thick, 95mm wide pre-laminated PVC sheet out of which 75mm shall be flat and 20mm shall be tapered at 45 degree on the inner side from top rail & bottom rail and 155mm pre-laminated sheet out of which 135mm shall be flat and 20mm shall be tapered on both sides to form lock rail.Top, bottom & lock rail shall be provided on either side of panel. 10mm (5mm x2) thick, 20mm wide cross PVC sheet shall be provided as gap inserted to top rail and bottom rail, paneling of 5mm thick pre-laminated wood grain both sides PVC sheet to be fitted with MS frame welded/sealed to the stiles & rails with 5mm+2mm thick x15mm wide PVC sheet beading on inner side and jointed together with solvent cement adhesive etc.An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of ‘C’ channel using PVC solvent adhesive complete all as specified and as directed. |
| 34 | S&F Pressedsteel frames of Size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and as directed. |
| 35 | S&F Pressedsteel frames for doors Size of frame 125 x 60 mm with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified and as directed. |
| 36 | S&F 30 mm thickFlush shutters, block board core and 0.50mm thick laminated wood grain texture incl all necessary adhesive for fxing to door shutter on both faces,complete all as specified and as directed |
| 37 | S&F 35 mm thick, 2nd class hard wood, glazed & skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. Sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24 (a) complete all as specified and as directed. |
| 38 | S&F stainless steel butt hinges medium weight of size 100mm complete all as specified and as directed. |
| 39 | S&F extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and as directed. |
| 40 | S&F aluminium anodised, barrel tower bolts of extruded section with length of bolt 150 mm and fixed complete all as specified and as directed |
| 41 | S&F aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy with length of bolt 250 mm and fixed complete all as specified and as directed. |
| 42 | S&F 140mm long floor door stopper of aluminium alloy body and tongue with hard drawn steel springcomplete all as specified and as directed. |
| 43 | S & F 300 mm long ISI marked mild steel ordinary rat tail rod pattern door spring including roller and roller plate complete all as specified and directed. |
| 44 | S&F framed work such as grill grating/cooler stand etc with ends of bars shouldered and/or riveted or forged into spikes frame gurads bars barred iron, door ladders, framed balusters walk way railings frame work of water tanks and similar work complete all as specified and as directed |
| 45 | S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with screws or beading in steel/ wooden door / window complete as specified and directed. |
| 46 | S&F Sheet glass 3mm thick ordinary qualityand glazing with oil putty in squeres n.exc 0.5 sqm in each panescomplete all as specified and as directed |
| 47 | S&F 4 mm thickFigured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane plain sheet glass ordinary quality and glazing with aluminium beading, complete all as specified and as directed. |
| 48 | Supply and fixing cutrain rod 20mm dia of stainless steelwith fixingbrackets, finials fixed to wall withpvc plug and screws including taking down existing curtain rod complete all as specified and directed. |
| 49 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surface of any description over 10 cm width or girth not otherwise described including prepration of surface complete all as specified and as directed |
| 50 | M&L for two coats of synthetic enamel paint over a coat of pink primer on new wooden surface of any description over 10 cm width or girth not otherwise describedincluding prepration of surface complete all as specified and as directed. |
| 51 | M&L for machine cut kota stone slab, 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including, cuttingand mirror polishing with and including20 mm thick screed bed or bedding layerin CM 1:4 for laying floor finishescomplete all as specified and as directed. |
| 52 | All as per item No. 1.54 here-in-before but as in riser of steps,dado/ pillars and vertical surfaces etc over and including 10 mm thick rendering on brick or concrete suface in CM 1:4 after taking down cement plaster on walls and racking out joints,hacking for key, scrubing down with water etc complete all as specified and as directed. |
| 53 | S&F stainless steel sink 1mm thick with drainage board for kitchen or laboratory with plugs, washers and wastes, bedding in cement mortar to dwarf wall or including fixing contilever brackets and connecting union to pipe overall size 915 x 460 mm with bowl size 410 x 330 x 160mm fixed in repair/replacement complete all as specified and as directed. |
| 54 | S & F vitreous china wash basin, white, flat back of size 550mm x 400 mm including brackets grouted in cement mortar 1:2 in wall fixed in repair/replacement complete all as specified and as directed. |
| 55 | S&F for Vitreous China wash down water closet pan ( pedestal pattern) white ( excluding flushing cistern and flush pipe) including plastic water closet seat closed pattern with flat botton and cover and mild steel chromium plated or aluminized hinging device fixed in repair/replacement complete all as specified and directed. |
| 56 | S&F health faucet (ABS Body) mild steel chromium plated suitable for 15 mmdia bore of pipe with1.25 meter long flexible tube and ABS wall hook including, making connections and fixed in position complete all as specified and as directed. |
| 57 | S & F vitreous china squating pan \"\"Orissa pattern size 580 x 440mm white with integral foot rest (excluding, flushing cistern and flush pipe) including connection to \"\"P\"\" trap and to flushing pipe fixed in repair/replacement complete all as specified and as directed. |
| 58 | S & F 10 ltrs capacity PVC low level syphonic action type flushing cistern including ball valve, bracket, inlet, outlet, overflow and PVC connectionfixed in repair/replacement complete all as specified and as directed. |
| 59 | S & F32mm bore (dia of discharge pipe) waste coupling of PTMT (half or full threaded) minimum weight 32mm- 45gms. Complete all as specified and as directed. |
| 60 | S & F pillar taps cast copper alloy with capstan head, chromium plated, fancy type, screwed down high pressure, with or without lettered ‘hot’ or ‘cold’ with long screwed shanks and fly nuts, screwed for iron pipes 15mm bore fixed in repair/replacement complete all as specified and as directed. |
| 61 | S&F PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed. |
| 62 | M&L for Galvanised iron tubing 15mm bore, medium grade, with all fittingsfixedto walls or ceiling or laid in floors, in concealed pipe work including making good the chases etc in cement mortar (1:3) after fixing of pipe, including taking down of old rusted/unserviceable GI pipecomplete all as specified and directed. |
| 63 | All as per item No. 1.65 here-in-before but 20 mm bore of pipe complete all as specified and as directed. |
| 64 | S & Fbib tap, cast copper alloy, fancy type, chromium plated,screwed down high pressure, screwed for15mm bore ron pipe or for brass ferrule fixed in repair/replacement complete all as specified and as directed. |
| 65 | S & F Shower rose 125 mm size brass chromium plated with swivel type joints including fixing to steel pipes or unionfixed in repair/replacement complete all as per specifiedand as directed. |
| 66 | S & F CP brass towel rail D type 60 Cm long and 20mm dia fixed to wall with screws and plastic cleats fixed in repair/replacement complete all as specified and as directed. |
| 67 | S & F stop valve15 mm bore of pipe,fancy type, chromium plated with long shank and cup (Concealed Type) cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions fixed in repair/replacement complete all as specified and as directed. |
| 68 | Supply and fixing angle valves, cast copper alloy, chromium plated,screwed down high pressure, with crutch or butterfly handle screwed for iron pipe or for brass ferrule 15 mm bore dia, fixed in repair/replacement complete all as specified and directed. |
| 69 | S&F soap dish size 160x160x90mm, vitreous china white, fixed to plugs with chromium plated brass screws fixed in repair/replacement complete all as specified and as directed. |
| 70 | S&F glass corner shelf 12\" with brass brackets of heavy duty and thickness of glass min 6mm and railing 60cm long fixed in repair/replacement all as directed |
| 71 | S&F Rotational moulded PVC water storage tanks 500 Ltrscapacity, double walled (ISI marked) with ISI marking embossed on the tank (cylindrical vertical with closed top) hoisted and fixed in position fixed in repair/replacement complete all as specified & directed. |
| 72 | S & F float valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for 20mm bore of iron pipe or brass ferrule fixed in repair/replacement complete all as specified and asdirected. |
| 73 | S&F Gun metal globe /gate/stop valve (ISI marked) with iron wheel head screwed both ends for iron pipe of 20mm bore fixed in repair/replacementcomplete all as specified and as directed. |
| 74 | Dismantling of CI/PVC pipe of 75/100mm dia bore fixed with cement joint complete all as specified and as directed |
| 75 | S & F 110 mm dia bore PVC (SWR) pipe (Type \"B\") having pressure rating 6 kgf/cm2 single socketed in trenches/floors in any length with rubber ring joints complete all as specified and as directed. |
| 76 | S & F 75 mm dia bore PVC (SWR) pipe (Type \"B\") having pressure rating 4kgf/ cm2 single socketed in trenches/floors in any length with rubber ring joints complete all as specified and as directed. |
| 77 | S & F PVC (SWR) bend/Door bend any radius for 110 mmbore pipe incl jointing material complete all as specified and as directed. |
| 78 | S & F PVC (SWR) junction single, (Single T) equal or unequalfor 110mm diaborecompleteall as spd and as directed |
| 79 | S & F PVC (SWR) bend/Door bend any radius for 75 mmbore pipe incl jointing material complete all as specified and as directed. |
| 80 | S&F 75 mm dia PVC (SWR ) floor trap/ nahani trap plain with grating including jointing with solvent cement fixed in repair/replacement complete all as specified and as directed. |
| 81 | S&F in repair 110 mm dia PVC (SWR ) floor trap/ nahani trapplain with grating including jointing with solvent cement fixed in repair/replacement complete all as specified and as directed. |
| 82 | S & F PVC (SWR) vent cowl equal or unequalfor 110mm dia bore fixed in repair/replacementcomplete all as specified and as directed. |
| 83 | S&F PVC gully traps square of size 125mm x 125mm including for setting and jointing to drain with CM 1:1 fixed in repair/replacement complete all as specified & directed. |
| 84 | S&F selected quality 5.5mm thick, 600 x 450mm bevelled edge mirror, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified & directed. |
| 85 | S&F Steel ventilators, with top hung shutter including hinges, steel peg stay made of MS sheet 1.25 mm thick box type (primer coated) , ERW hollow \"P\" section of size 60mm x 25 mm complete all as specified. |
| 86 | Demolition of cement concrete as in ground floors and in paving not exc 15cm thick below or above ground level complete all as specified and as directed. |
| 87 | M & L 75 mm thick, plain cement concrete 1:3:6, type C-2, using 40 mm graded mechanically crushed stone aggregates, laid in 1:20 slope as in plinth protection/pavings/shafts including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/ 25 & two parts heated sand (by volume), surface finished even and fair without using extra cement, complete all as specified. Note: The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm. |
| 88 | M&L for 25mm thick plain cement concrete (1:2:4) type B0 (Using 12.5mm graded crushed stone aggregate) as in sunken portion complete all as specified and as directed. |
| 89 | M&L for cement concrete Type- F2 1:7:12 (40 mm graded aggregate) in filling and mass concrete as in sunken portion all as specified and directed . |
| 90 | M&L for 15 mm thickrenderingin1:4 CM as in sunken portion complete all as directed. |
| 91 | Writing letters or figures by specialist / professional painter (Block, Roman, Italic or indian) with thick black synthetic enamel paint not exc. 10cm heighton white basecomplete all as specified. |
| 92 | M&L for water proofing treatment to sunken portions by clearing the sunken/lowered portion of RCC slab surface for full depth of sunken portion, chieseling out the sticked mortar and applying FOSROC Nitoproof 600 PF (minimum 0.8 mm dft) over a priming coat of Nitoproof WB Primer or equivalent product of makes specified here-in-after and applied to bottom and full vrtical sides as per manufacturer\"s instructions.Note:- (a)All pipes passing through walls of sunken floor shall be laid before water proofing treatment is carried out. One No. 50mm dia, 35cm long medium grade GI pipe with wire gauge on inside mouth shall be provided to each sunken protion.(b)The sunken portion will be filled with water for dampness and seepage check. In case the slight indication of seepage/leakage is noticed, the same shall be rectified by injectting / grouting to seal all cracks withapplication of Plymer modified mortar FOSROC nitobond SBR orequivalent product of makes specified here-in-afterwith integral WPC or cementitious crysatlline waterproofing compound in the affecrted raea to seal all cracks and micro cracks at his own cost and nothing extra will be admissible on thgis ground. (c)An additonal coat of FOSROC Nitoproof 600PF or equivalent product of makes specified here-in-after shall be applied to all junction points of side walls where CI/GI pipes are passing and the same will be seeled with epoxy cement mortar.(d)The work of water proofing to roof and sunken portions shall be executed by the manufacturer\"s authorized trained/skilled applicator as per technical guidelines issued by the manufacturer. A MOU is to be executed between the contractor and manufacturer and the same will be got approved from the GE/AGE (I) before commencment of work.The Contractor will arrange to provide company back guarantee for the water proofing work for the period specified here-in-after. |
| 93 | S& F factory made box type glazed and gauged steel window/ventilator made out of ERW hollow P&T section including taking down of old window . Both window to be welded together with flat iron 25x3mm to outer frames on both sides complete all as specified and shown in drawing No CEAF/STD-184/2012 Sheet No 1/3, 2/3 & 3/3, including MS grill and necessary formwork complete and including shop coat redoxide primer with following fittings welded to frame/shutter:-(a) Hold fast 150mm long 25mmx6mm iron made to shape-02 Nos in each window (both sides)(b) Handle of \"Z\" section 20mmx25mm Each leaf(c) 100mm stopper-01 No per leaf.(d) MS tower bolt 150mm long - 02 Nos in each leaf.(e) Cleat 55mm long of hollow square 15mmx15mmx24mm welded to hinges gauze wall thickness welded to hinges of 50mm size-01 No per leaf.(f) MS box type hinges of size 75x12mm-03 Nos per leaf(g) Fabrication & fixing complete(h) Flat iron for fixing wire gauge to gauge window Glass pane, wire gauge and synthetic enamel painting work complete.Note:- (i) Glass panes, wire gauze and painting shall be measured & paid Separately under respectiveii) Design shall be got approved from the Engineer-in-charge as per Drg No CEAF/STD-184/2012Sheet No 1/3, 2/3 & 3/3 before fabrication and bulk order to the manufacturer. |
| 94 | Supply and fixing stainless steelplate rack made out of 1mm thick stainless steel sheetwith over all size 600 mmx750 mmx250 mm, complete all as specified and directed. |
| 95 | PATH/HARD STANDING WORK |
| 96 | Surface excavation n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft and loosesoil all as specified and directed. |
| 97 | M&l for removal of excavated material exc. 500m and n.exc 1.5 km and depositing complete all as specified and directed. |
| 98 | M&L for laying PCC type D2, 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation,filling , mass concrete as sub base all as specified and directed by Engr-in-charge. |
| 99 | Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved design & pattern as in footpath , parks , lawns,drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator,filling joints with sand andcutting of paver block as per required size and pattern,finishing and sweeping extra sand , including coping at sides from PCC 1:2:4 all as specified and directed by Engr-in-charge. |
| 100 | Providing and laying at or near ground level factory made kerb stone/saucer drain of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 101 | SEWAGE WORK/DRAINAGE |
| 102 | Excavation in trenches not exceeding 1.5 meter depth for foundation as for manholes, pipe holes etc. and getting out in hard/dense soil complete all as specified and directed. |
| 103 | Returning, filling in trenches (soil) including spreading leveling and well ramming in layers not exc 25 cm thick complete all as specified and as directed. |
| 104 | Removal of surplus excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 105 | M&L for Concrete bed to 150 mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested; in cement concrete (1:3:6) type C-2 complete all as specified and as directed. |
| 106 | M& L for 150 mm dia Reinforced concrete pipes, class NP2, laid in trenches and jointed complete with collars complete all as specified and as directed. |
| 107 | M&L for laying concrete pipes of 300 mm dia , class NP2 laid and jointed complete with collars all as specified and directed. |
| 108 | M&L for concrete bed to drain pipes of dia 300mm including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete (1:3:6) type C-2all as specified and directed by EIC. |
| 109 | M&L for brick work with old size sub class “B” bricks straight or curved on plan exc. 6mtr mean radius built in CM 1:6 complete all as specified and as directed. |
| 110 | M&L for brick work with old size sub class “B” bricks straight or curved in plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed. |
| 111 | Material and labour for Preparation of newly plastered surfaces of walls and applying two coats of white wash complete all as specified and as directed. |
| 112 | Material and Labour for PCC (1:2:4) type B-0, using 12.5 mm graded crushed stone aggregates, as in coping, roof kerb, mud stops, kneelers, apex stones, bed plates,benching, water trough etc including weathering, slightly rounded or chamfered angle and throating, including necessary form work, complete all as specified and directed. |
| 113 | M&L for Providing precast cement concrete 1:2:4: type B-1(using 20mm gradedstone aggregate) as in landings, cover slabs (for manholes), chullahhoods,chajja, water troughs,shelves and similar articles etc.with plain faces,setting in cement mortar 1:4 complete all as specified and as directed. |
| 114 | Cutting into existing manholes for connecting new drains 150 mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 115 | INTERNAL ELECRIFICATION WORK |
| 116 | Taking down carefully copper / aluminum point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, lamp holders, bracket, light fittings, bulk head fittings, tube light fittings etc. and making good disturbed surfaces of walls, floors etc as per existing complete all as specified and directed. |
| 117 | M&L for Point wiring for One light /Celing fan/ Exhaust fan point/Bell point, controlled by one switch 5 Amp SP one-way complete with 1.5 Sq mm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLSH cable (ISI marked) drawn into and including PVC concealed conduit (medium quality) and conduit fittings including 1.5 Sq mm PVC insulated unsheathed and multi stranded copper conductor FRLSH cable as earth wire to common earth and connecting to earth dolly including MS sunken box covered with 3mm thick bakelite laminated “hylem or Philips“ sheet top cover and machine made brass screw and washers etc complete all as specified and as directed Notes;- (i)For Internal wiring colour to be used as per IE rule for Phase - Red/Yellow/Blue,Neutral- Black and Earth- Green(ii) Quoted rate shall deemed to be included for Making good of disturbed surfaces with and including M&L for applyibg finishes to match with existing surfaces, (iii)Switch/socket to be measured and paid separately. |
| 118 | All as per item No. 4.02 here-in-before but wiring for one 3 pin 6 Amps socket outlet point on the same board, controlled by other switch complete all as specified and directed. |
| 119 | All as per item No. 4.02 here-in-before but wiring for one 3 pin socket outlet 6 amps independent board. |
| 120 | All as per item No. 4.02 here-in-before but controlled by(two) 2 way switch, complete all as specified and as directed. |
| 121 | All as per item No 4.02here-in-before but with 2.5 Sqmm size cable multi stranded FRLSH copper wire unsheathed for one 3 pin socket outlet16 Amp on independent board and including2.5 sqmm multi stranded copper conductor FRLSH cable as earth continuity wireconnecting to common earth dolly completed all as specified and as directed.Note :- Sunken boxes, frame, plate etc shall be included in the quoted rate. |
| 122 | S & F of switch piano flush type single pole one-way 6 Ampere complete all as specified and as directed. |
| 123 | S & F of switch piano flush type single pole two-way 6 Ampere complete all as specified and as directed. |
| 124 | S & F of switch piano flush type single pole one-way 16 Ampere complete all as specified and as directed. |
| 125 | S & F of 6 Ampere socket outlet flush type, multi purpose suitable for 3 pins complete all as specified and as directed. |
| 126 | S & F of socket outlet two-in-one, 3 pin each suitable for 6 and 16 Ampere flush type with shuttered complete all as specified and as directed. |
| 127 | S & F of ceiling rose, surface bakelite, 65 X 50 mm, 3 terminals complete all as specified and as directed. |
| 128 | S&F of lamp holder PVC / polycorbonate type insulated body with back plate suitable for batten fitting / angle fitting completeall as specified and as directed. |
| 129 | S&F LED tube light fitting 1x20 watts ( LUMENO Model ofHavells or equivalent Model of Make specified here-in-after) with PVC insulatedflexible copper cable from ceiling rose to tube light fitting complete all as per specified and as directed. |
| 130 | S & F1 x 10 watt LED bulk head luminaires including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 Volts, 50HZcomplete all as specified and as directed. |
| 131 | S & F callbell \"ding dong\" type AC 230 volt single pole fixed over with and including PVC rectangular block of size 175mm x100mmx50mmcomplete all as specified and as directed. |
| 132 | S&F of bell push, flush type,5 Amperecomplete all as specified and as dircted. |
| 133 | S & F stepped type electronic fan regulator flush type on the existingphenolic laminated sheet etc. as reqd heavy duty 230 voltscomplete all as specified and dircted. |
| 134 | Supply and fixing LED Tube Light surface mounting 10 watt 2 feet LED light suitable for mirror light with milky diffuser including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 Volts, 50HZ complete all as specified and directed. |
| 135 | M& L for Sub main wiring with two single core 6 sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including non metalic PVC regid conduit medium grade of suitable size with all standard fittings,concealed, including one run of continuous PVC insulated stranded copper conductorFRLSH cable 6 sqmm (nominal area) for earth continuty, including taking out and removal of old sub main wiring complete all as specified and as directed.(Note :- 2 runs of 6sqmm copper conductor phase and neutral and one run of same size earth wire including one run of PVC conduct with cutting, chasing & making good shall be measured as one unit length) |
| 136 | M & L for vertical type sheet steel enclouser distribution boards, double door factory made3 phase 415 volts 4 way with 200 amps rating copper bus bar of suitable size and PVC insulatedcopper jumpers from the MCCB to the out going circuits (oneincoming MCCB and 12 outgoing MCBs circuits) comprising of 3 phase 4 wireof suitable rating includingMCCB 160 amps, 25 KA, TP, 415 volts, 50 Hz = 01 No. and 12 Nos MCBs 6-32 Amps, complete all as specified and as directed. |
| 137 | S & F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 8 ways including blanking plate as required with 200 Amps rated bus bar,240 volts fixed sunk/flush to the wall or niche complete all as specified and as directed including necessary brick work and plaster to match with the existing surface complete all as specified and as directed. |
| 138 | S & F MCB DP, 240 Volts, AC, B curve, 10 KA, 40 Amps (10 KA \"B\" rupturing capacity)complete all as specified and as directed |
| 139 | S & F MCB single pole, 240 Volts, AC, B curve, 10 KA,6 to 32 Amps (10 KA \"B\" rupturing capacity)complete all as specified and as directed |
| 140 | S &F LEDstreet light /security light luminaries fitting 1X35 watt LED includingfixing on existing bracket made out of GI pipe light grade 32 mm dia 1.20 m long bent to shape with suitable size mild steel clamps of size 50 X 6mm with nut, bolt, & washers as required at site for fixing of street light on LT poles / wall including making connection with PVC insulated 3 single core of 1.5 sqmm size multistranded copper conductor cable complete all as specified and as directed. |
| 141 | M&L for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5 m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 25mmx4mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 32mm dia bore, and watering pipe 20 mm bore GI light grade pipe with funnel & wire mesh,including all necessary excavation & earth work,PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, including taking out old earthing materials and removalcomplete all as specified and directed.Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include GI strip and protection pipe of length 7.5m, GI pipe beyond 7.5m length required at site shall be measured and paid separately.(iv)Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt. |
| 142 | Taking down existing Ceiling fan/Exhaust fanfor repair & refixing the same at its old position/location, including provision of required winding, synthetic enamel paint by spraying, nuts bolts and fastner, transportation etc, complete all as specified and as directed. Note: The ceiling fan/Exhaust Fan taken down should be deposited to MES store yard after necesscary repair and painting and the same has to be fixed after completion of B/R work |
| 143 | Taking down old water heater from site and refixing the same after repair which includes change of element, thermostat, PVC Connections Hot&cold (02 Nos) , painting with synthetic enamel paint including accessories such as safety valve, thermostate, NRV, connection piece and change of appartus plateetc. all as specified and directedNote: Cost of flexible copper cable of 3 core, PVC steel braided inlet/outlet pipe of 15mm dia, 450mm long with brass union, NRV, check/end nuts, nipples, MS bolts, etc., and minor parts,appartus plate if any, other than those are not specified in the schedule and required for smooth functioning of geyser will be deemed to be included in the quoted rate |
| 144 | M&L for sub main wiring two single core 4 Sqmm(nominal area) multi-strand copper conductor FRLS PVC insulated and unseathed cable drawn in and including non metalic PVC regid conduit medium grade of suitable size with all standerd fittings, concealed including one run of continous PVC insulated stranded copper conductor FRLS cable 4 sqmm for earth continuty, including taking out and removal of old sub main wiring, complete all as specified and directed.Make: Havells, Poly Cab, Grandlay Note:- Rate quoted shall be deemed to include cutting chases for concealed conduit and making good incement mortar(1:4) or PCC (1:2:4) |
| 145 | Supply and fix sheet metal enclosure single pole with two pin and earth plug and socket complete with one single pole MCB20 Amp complete all as specified and directed by Engr-in-Charge.Make: Legrand, ABB , Indo Asian |
| 146 | Taking down existing Electronic Meters & refixing the same after repair the bldg at its old position/location, including provision of required wiring and fixing properly with connected accessories complete all as specified and directed. |
| 147 | Supply and fixing louvers of exhaust fan suitable for 300/380/450 complete all as specified and directed. |
| 148 | External Water Supply Work |
| 149 | Supply and Laying in trenches/drawn through pipes or in road crossings/paths/drains/ ducts/floors/along poles/equipments etc., of LT cable under ground, heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of 35 Sqmm 3½ core cross sectional areas including connecting up using suitable size aluminium lugs, double compression copper stainless steel gland etc., testing and commissioning complete all as specified and directed.NOTE: (a)Excavation & earthworks will be measured and paid separately(b)The cost of lugs, gland etc., will deemed to be included in the quoted rate. |
| 150 | Cutting hard standing/road not exceeding 1.5m deep and making good with and including PCC (1:3:6) type C2 (using 40mm graded aggregates) and removal of debris and making the damaged areas uniform as per existing complete all as specified and directed. |
| 151 | Supply & laying double wall corrugated (DWC) high density poly ethylene (HDPE) of size 50 mm bore/dia including all necessary fittings, PN-4 rating, pressure 6 Kgf/cm², conforming to IS-16205 (Part- 24) with high ring stiffners & crush resistance capacity, etc., laid in trench for protection of cable complete all as directed. |
| 152 | Supply & laying GI pipes 40 mm dia bore, medium grade with all necessary fitting, laid in trenches or with walls fixed in repair/replacement complete all as specified and as directed. |
| 153 | Supply & laying GI pipes 20 mm dia, medium grade with all necessary fittings laid in trenches or with walls fixed in repair/replacement complete all as specified and directed. |
| 154 | Drilling and tapping cast iron water mains (in position) for branch connections of internal dia 20 mm including S&F brass ferrule for branch connection complete all as specified and as directed. |
| 155 | Note: The Total amount shall subject to adjustment of credit of Rs. 239524.00 for old Materials as per Schedule of Credit. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy