Tender For Comprehensive Maintenance And Certain Misc B/R And E/M Works At C1 And C1a  Area Under Ge(East) Mathura Mil Stn;  1 Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.  2 M&L for coloured Non skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchl aidover and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.  3 M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchl aidover and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.  4 M&L forcoloured Glazed ceramic tiles on vertical surface 600x300x7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match fixed over and including 10 mm thick backing coat of cement mortar in 1:4 complete all as specified and directed.  5 M&L for coloured double charged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.42 sqmbut not exceeding 1.00 sqm,, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.  6 Demolition of Stone slabs and tiles of any description or thickness (except ceramic tiles) in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed.  7 M&L for 16-18 mm thick Granite Z black slab work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like laid over and including 20mm thick screed bed in cement mortar 1:4 and pointing in white cement (1:2 )using marble dust with admixture of pigment to match with shade of granite, including rounded/half rounded edge and providing hole for gas pipe in pre-cast slab as well as in granite slab of cooking platformcomplete all as specified and as directed.  8 Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed.  9 M&L for Brick work with old size fly ash Bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.  10 Taking down cement plaster on brick or stone walls,concrete surface etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.  11 M&L rendering 15mm thick on fair face of brick work/concrete in CM 1:4 and finishing surface even and fair by mixing liquid water proofing compound including two coats of Apex exterior emulsion paint over one coat of alkali resistant primer as per manufacturers instructions complete all as specified and as directed.Note :- Liquid WPC shall be measured & paid seprately under relevant item of this BOQ.  12 Supply only liquid water proofing compound hydroseal-W+ /Dr Fixit or eqivalent (for plaster hardening, to contol efflorescence & fungal growth) as approved by Engineer-in-charge.  13 M&L for rendering 15 mm thick on other than fair faces brick wall or concrete surface in cement mortar 1:6 finished even & smooth without using extra cement complete all as specified and as directed.  14 M&L for 10mm thick rendering on fair faces of brick/concrte surface as in ceiling in cement mortar 1:3 finished the surface even and smooth without using extra cement and applying threecoats of white washon ceiling surface complete all as specified and directedcomplete all as specified and as directed.  15 M&L for preparationof new plastered surface of wall and applying providing one coat ofwall care putty ,two coats of Oil Bound Distemper over and including one coat of alkali resistant primer on wall complete all as specified and directed by Engineer-in-Charge.  16 M&L for preparationof new plastered surface of ceiling and applying threecoats of white washon ceiling surface complete all as specified and directed by Engineer-in-Charge.  17 M&L for preparartion of new plastered surfaces of walls and applying two coats cement base paint on walls complete all as specified and as directed.  18 Taking up or down 15 mm bore steel tubing and connections including cleaning for refixing or removalfrom site complete all as specified and as directed.  19 Taking up or down 20 mm bore steel tubing and connections including cleaning for refixing or removalfrom site complete all as specified and as directed.  20 Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth of brick walls complete all as specified and as directed.  21 Supplying & fixing steel tubing ,galvanised, medium grade 15 mm bore with all fittings and fixed complete to walls and ceiling or laid under floor complete all as specified and as directed.  22 Supplying & fixing steel tubing ,galvanised, medium grade 20 mm bore with all fittings and fixed complete to walls and ceiling or laid under floor complete all as specified and as directed.  23 S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.  24 S&F in repair 75 mm bore PVC (SWR)pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.  25 S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wallscomplete all as specified and as directed.  26 S&F in repair 110 mm bore PVC (SWR) plain bends any radius complete all as specifiedand as directed.  27 S&F in repair 75 mm bore PVC (SWR) bends with access door any radius complete all as specified and as directed.  28 S&F in repair PVC floor trap plain 75 mm dia of outlet with grating including jointing with solvent cement complete all as specified and as directed.  29 S&F long body bib taps cast copper alloy, chromium plated, fancy type with half turm handle having weight of bib tap should not be less than 450 gms or as per SSR Part-I specification for iron pipes15 mm bore dia complete all as specified and as directed.Make:-Jaquar Cat Part No. KUP-CHR-35037/CERA Cat Part No. F-1003151/Kohler Cat Part No. K-160931N-4-CP  30 S&F in repair fancy type 15 mm size long body angular cock, cast copper alloy, chromium plated, fancy type with capstan head having weight of angular cockshould not be less than 450 gms or as per SSR Part-I specification, screwed down, screwed both end for iron pipes complete.Make:-Jaquar Cat PArt No. KUP-CHR-350553PM/CERA Cat Part No F-1014201/Kohler Cat Part No. K-801541N-4AV-CP  31 S&F in repairs stop valve, 15 mm chromium plated with long shank and cup (Concealed type) both ends for iron pipe  32 S&F in repair vitreous china wash hand basin white flat back size 550 x 400 mm including bracket and pair of rack bolts waste coupling pillar tap cast copper alloy chromium plated fancy type complete all as specified and directed.  33 S&F in repairs 15 mm dia brass chromium plated pillar taplong shank with fly nuts capastan head screwed down high pressure with or without lettered hot or cold with long screwed shank having weight of pillar should not be less than 450 gms or as per SSR Part-I specification complete.Make JAquar/Kohler/CERA F 1014101  34 S&F in repairs 750 mm long PVC flexible waste pipe 32 mm dia for fixing in urinals and wash basin complete.  35 S&F in repairdesigner looking mirror of size not less than 1.0 Sqm,selected quality5 mm thick, fixed with chromium plated screws complete all as specified and as directed.  36 S&F Swivel CP shower of size 200 mm for fixing with 15mm pipe (minimum weight 40gms) complete all as specified and as directed.  37 S&FShower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour (minimum weight 40gms) complete all as specified and as directed.  38 S & F in repairs Viterous china squatting pan, Órissa pattern, size 580 x 440mm white, with integral foot rests including connection and fitting to trap, and to flushing pipe complete and making good to wall or floor tilling to match the existing complete all as specified.  39 S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, Plastic water closet seat, white, closed pattern with flat bottom, and cover with aluminised hinging device, complete all specified and as directed.  40 S&F in repairs 10 ltrs PVC (White) valve less syphonic action type, flushing cistern low level with inlet ball valve float, handle, aluminium brackets for bottom support fixing with gitties embeded in wall with drilling machine etc complete.  41 S&F in repairtwo way angle cock cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes 15 mm bore dia weight of two way angle cockshould not be less than 450 gms or as per SSR Part-I specification complete all as specified and as directed.  42 S&F in repair Health faucet of superior quality ABS body with 8 mm dia 1.2 m long flexible tube and wall hook complete all as specified and as directed.  43 S&F in repair 600 mm long PVC connections 15 mm size with PTMT nuts at both end complete.  44 S&F in repairs stainless steel towel ring 600 mm long 20 mm diafixed with steel screw etc complete all as specified.  45 S&F in repair stainless soap dish fixed to wall complete all as specified and directed.  46 S&F in repair 20 mm dia Gun metal, globe or gate valves,with iron wheel head,including making thread to both ends of pipes for fixing,screwed both ends for iron pipes and fixed.  47 S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.  48 Taking down chowkhats or frame with shutter (without taking off shutters from the frame) area n.exc. 1.50 Sqm each and making good the disturbed surface complete all as specified.  49 Taking down Chowkhats or frames with shutter without taking off shutters from the frames exc. 1.5 sqm but n exc 4 Sqm each complete all as specified and as directed.  50 Taking down shutters of any description exceeding 1.0sqm and not exceeding 2.0sqm each complete all as specified and as directed.  51 S&F Solid WPC Door Frame of size 50mm x 47mm complete all as specified and as directed.  52 S&F30 mm thick factory made WPC door with both side lamination complete all as specified and as directed.  53 S&F Pressed steel frames of size 105x60 mm made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., with one shop coat of red oxide primer complete as specified and as directed.  54 S&F Pressed steel frames of size 125x60 mm made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.with one shop coat of red oxide primer complete as specified and as directed.  55 M&L for cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in bed blocks for fixing hold fasts and filling of chowkhats etc complete all as specified and as directed.  56 M&L for prepration of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over primed surface complete all as specified and as directed.  57 S&F 35 mm thick factory made glazed and skeleton shutters open rebated and prepared to receive glass, gauze, etc without sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters asspecified in SSR Part-1 section 8 clause 8.24(a) complete all as specified and as directed.  58 S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as spicified and as directed.  59 S&F 30 mm thick factory made flushshutters, solid core construction withblock board core and plywood face panel veneer type on both side complete all as specified and as directed.  60 M&L for preparation of new wooden surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.  61 Supply and fix 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed  62 Supply & fix 100mm long hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21  63 S&F 200 mm size aluminium anodized barrel tower bolts of extruded section and fixed.  64 S&F 150 mm long aluminium anodised handle fabricatedtype all as specified and as directed by Engineer-In-Charge.  65 S&F powder coated Aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.  66 M&L for powder coated aluminium window shutters (Thickness or powder coating not less than 50 micron)., side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21100mm long (2 no.) suitable handle (1 no.) complete all as specified.  67 M&L for powder coated aluminium door shutters (thickness or powder coating shall not be less than 50 microns of approved colour)aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, lock with 2 keys, anodized aluminum snap beading screws etc. complete all as specified and as directed.  68 S&F 5.5 mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane.  69 S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con-forming to Fe.290.Gde-E-165.  70 M&L for preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.  71 Dismantling wall and ceiling boards (fiber, pulp, insulation, etc) or insulation board/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.  72 Providing and fixing false ceiling with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles at all heights with GRG (Glass fibre reinforced Gypsum) False ceiling tiles of size 595x595mm of approved texture,design and patterns having moisture content less than 2%, humidity resistance of 99%,NRCO .50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part-4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @120 grams per sqm (including both sides) comprising of main T runnersof size 15x32mm of length 3000mm ,cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600mm to form a grid module of size 600x600mm,suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm)i.e. 50 mm long ,8mm outer diameter M-6dash fasteners ,6mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x24x0.40 mm of length 3000mm to be fixed on periphery wall /partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall screws. The work shall be carried out as per specifications,drawing and as per directions of Engineer in charge.  73 S&F in repair floor door stopper of aluminium anodisedbodyand tengue, anodised with hard drwan steel spring overall length of cover plate 140 mm complete all as specfied and as directed.  74 S&F in repair Aluminium (die cast) body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg complete all as specified and as directed.  75 S&F in repair25 mm dia stainless steel drapery rod cut to size and fixed in position including end caps, roller and brackets fixed to wall complete all as specified and as directed.  76 S&F in repair stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as spicified and as directed.  77 S&F in repair 2nd Class hard wood plain fillets square/ rectangular or trianguar in section, sectional area exc 6 Sqcm but n.exc 13 Sqcm, clean sawn and fixed withnails complete all as specified and as directed.  78 S&F in repair 250 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed.  79 S&F in repair 100 mm long size of hinges, extruded aluminium alloy with galvanised mild steel hings pin anodized and fixed type B-21complete all as specified and as directed.  80 S&F in repair Extruded aluminium handles of size 150 mm, fabricated type anodised complete all as specified and as directed.  81 S&F in repair aluminium anodized barrel tower bolts 200 mm length of bolt of extruded section and fixed complete all as specified and as directed.  82 S&F in repair 300 mm size mild steel rat tail rod pattern door springs ISI marked including roller & roller plate etc complete all as specified and as directed.  83 Demolition of concrete of any description and position not otherwise specifically provided for as in sunken floor etc. complete all as specified and as directed.  84 M&L for providing cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) in lintel upto 1.5 m span, coping, kerbs, stops, cills, bed plate and the like complete all as specified and as diected.  85 M&L for cement concrete 1:7:12 type F2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.  86 Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.  87 M&L for 100 mm thick cement concrete type-D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.  88 M&L for sand filling under floors or in foundations incl watering and consolidation complete all as specified and as directed.  89 M&L for Machine pressed precast concrete interlocking paver block with grey cement and no pigments any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade complete all as specified and as directed.  90 M&L for 50 mm thick cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and fair without using extra cement complete all as specified and as directed.  91 M&L non skid colouredcermic ENDURA tiles 400x400x15mm thick set and jointed in neat cement slurry & pointed with coloured cement to match in floor over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.  92 S & F 18 mm thick WPC board both side decorative fixed with screws, solvent cement/ adhesive/bolts to make kitchen cabinet sides top and bottom and shelves inside the cabinets etc. complete as per specifications and as directed.  93 S & F 16 mm thick WPC board of Single SidePrelam/ Rigidlam color fixed with screws, solvent cement/ adhesive to make kitchen cabinet sides top and bottom and shelves inside the cabinets complete as per specifications and as directed by the engineer - in -charge. (Density- 575 to 600 Kg/CBM) (Make- Rajshri Plastiwood  94 S & F 12 mm thickWPC boardofplain white(Matt finish) color fixed with screws, solvent cement/ adhesive to make wall mount kitchen cabinet back and pull out drawer sides complete as per specifications and as directed by the engineer - in –charge- ( Density- 575 to 625 KG/CBM)(Make- Rajshri Plastiwood.  95 S&F in 100 mm sizealuminium anodised Hasp and staple, safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed.  96 M&L for providing stainless steel handle 125mm complete all as specified and directed.  97 S & Fauto closing hinges 35 mm of 0 crank( KH-001)OR8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters -(Make- KAFF, Godrej & Hettich)  98 Taking down carefully aluminium / copper point wiring (light, fan, socket any type, power, bell etc.) complete including fixtures & fittings (such as ceiling rose, socket, Pendent, regulator, light fittings etc) and removing the materialfrom site and making good the disturbed surfaces of walls ceiling etc complete all as directed.(Note: Credit for above items should be made as per credit Schedule separately).  99 Taking down carefully by Submain wiring of any type complete and making good disturbed sufaces to match with the existing surfaces all as directed by Engineer-in-Charge.  100 Taking down old unserviceable existing SPN/TPN DBs / enclousers any size and type / any descriptions as iron sheet scrapincluding MCB any type / size and making good disturbed surface / wall as per existing complete all as specified and directed.  101 M & L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, 1100 volts grade copper conductor, inuniversal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) including with modular flush metal boxes with modular cover plates & frame for mounting modular switches, sockets, regulators etc or including sunk cast iron /pressed steel/terminal boxed for mounting flush typeswitches/sockets etc with 3 mm thick phenolic laminated sheet covers and including earth wire ofPVC insulated (FRLS) copper conductor multistrandedof 1.5Sqmmsize in green colourcomplete all asspecified in current SSR Part-I & II & directed by the Engineer-in-Charge as described below (item no 104 to 108):-  102 a)One light/ fan point controlled by one way switch 5 amp complete.  103 c)One 3 pin 5 Amps socket point controlled by one way switch on same board.  104 d)One 3 pin 5 Amps socket point controlled by one way switch on independent board.  105 e)One bellpoint controlled by one push button.  106 f) One light point controlled by two 2-way switches.  107 All as per item No. 103 butfor 3 pin / 5 pin 16 Amps sockets outlet with 4 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent Point wiring complete all as specified and as directed .  108 Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module complete.  109 Supply and Fixing Modular bell Push switch 6 Amps with indicator single pole one-way, 1 Module.  110 Supply and Fixing Modular switch16 Amp single pole one way,1 Module all as specified.  111 Supply & Fixing Modular fan Regulator electronic step type complete all as specified.  112 Supply and Fixing Modularsocket2-in-1, 5 pins 6 Amps , combined 2 Modulecomplete.  113 Supply and FixingModular socket 2-in-1,3 and5 pins 6 /16 Amps, combined 2 Module complete.  114 Supply and Fixing Modular switch 6 Amps single pole two-way, 1 Module complete all as specified.  115 S/F in replacement switch piano type , SP, one way, flush type 5 Amps complete all as specified.  116 S/F in replacement socket out let 2 in 1 flush type 5 pin 5 Amp complete all as specified.  117 S/F in replacement socket out let 2 in 1 flush type 3 pin 5 & 15 Amp complete all as specified.  118 S/F in replacement switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified.  119 S/F in replacement bell push siwtch piano flush type, SP, one way, 5 Amps complete.  120 Supply and fix in repair ceiling rose surface bakelite 65mm x 50mm three terminals complete.  121 Supply and fix in repair lamp holder, PVC / polycarbonate type with back plate.  122 Supply and fix in replacement mini MCB enclosure including DP 16 amp, type C curve complete.  123 Supply and fix in replacement Bell Ding dong type, 230 Volts complete with connection.  124 S/F in replacement fan Regulator piano flush type (Socket type as per existing), electronic step type complete all as specified.  125 M & L for Sub Main Wiring wiring with two runs single core 4 Sqmm PVC insulated unsheathed(FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 4 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge.(Note: Two runs of 4 Sq mm (P&N),one run of 4 Sq mmearth wire & One run ofPVC casing and caping will be measured as one RM).  126 All as per Item No 127 but for 6 Sqmm  127 All as per Item No 127 but for 10 Sqmm  128 Supply & fix in repair indoor decorative ultra slim surface /Wall mounted LEDbatten tube light complete fitting 1x 20 watt LED Tube fitting withpolycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- relatedcolour temperature (CCT) of 6500K, >100 Lm/Wattcomplete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.  129 Supply & fixing in repair indoor decorative ultra slim surface /Wall mounted T5 LEDbatten tube light complete fitting 1x10 watt LED Tube fitting (size within 600x25x40 mm) suitable for mirror light with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- relatedcolour temperature (CCT) of 6500K,>100Lm/Wattcomplete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.  130 S&F in repair surface mounted bulk head LED light fitting, capacity 10 watt, opal diffuser, IP 65 protection complete with all accessories and connection complete all as specified and as directed.Make: Bajaj Cat part BIBWP10W LED or equivalent in Philips / Havells / Wipro  131 Supply and fix LED9 Wsuitable for normal holder(Base Cap B22 / E14) complete all as specified.  132 Supply and install in replacement of 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainablewith heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- relatedcolour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280Vincluding all connections complete all as specified.  133 Supply & fix in repair recess type, 35/36 watt LED panel light (600x600 mm) complete with fittings integrated electronic driver,energy efficient, 230 volts,co- relatedcolour temperature (CCT) of 6500K,complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.  134 S&F in repair LED bed side light fitting, 3 watt, wall mounted with adjustable arm, On /Off inbuilt switch including connection complete.Make : Havells or equivalent to Philips / Bajaj / CGor as directed as per site  135 S&F in repair indoor wall mounted fitting, brushed nickel finishfixture with opal glass diffuser, with LED retrofit bulb of capacity 09 watts complete Make: Havells cat part No LHFOAJE1TZ1I060  136 S&F in repair LED post top light fitting 30W IP-65 rated completeall as specified and directed. Make: Surya Cat part No SLE PT 30W-ETPP or equivalent.  137 S&F in repair LED Round/square recess mounted slim downlighter 12 watt, integrated electronic driver, co- relatedcolour temperature (CCT) of 6500K complete all as specified.  138 All as per Item No 35 but for 18 Watt  139 M&L for building securitylight bracket made out of 40mm dia light grade GI pipe of 1.2 m length bent to required shape suitable for fixing street light fitting on Steel tubularpole/wall including two Nos clamps made out 40mm X 6mm flat with suitable nuts and bolts including two coats of aluminium paint over a coating of red oxide primer complete all as directed taking down old unserviceable bracket as scrap any size / description.  140 S&F in replacement MCB distribution board, SPN 12 Way, Double door, sheet steel, phosphatised, powder painted withbus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified.  141 All as per Item No 142 but for 8 Way  142 All as per Item No 142 but for 4 Way  143 Supply & fix in replacementMCB SPN63 Amps, C series , bracking cap10KA, 240V complete.  144 Supply & fix in replacement of MCB SPN40 Amps, C series , bracking cap 10KA, 240V complete.  145 Supply & fix in replacement of MCB SPN6-32 Amps, C series , bracking cap 10KA, 240V complete.  146 Supply & fix in replacement of MCB SP 6-32 Amps,  C series ,bracking cap 10KA, 240V complete.  147 Supply and fix in replacement SP enclosure with a two pin and earth plug and socket complete with SP MCB of rating 20 Amps, 240 Voltswith all connection complete all as specified and directedMake : Havellsor equivalent of Legrand /L&T/ C&S  148 Supply & fix in replacement metal clad SPN plug top 20 Amp for fixing on AC Box complete.  149 Supply and fix modular MCB DP 16 Amp,  C series, 240 V complete all as specified and directed.  150 S&F in repair Plastic Surface mounting box 1 / 2 module gang box for mounting switches, sockets, fan regulator etc complete all as directed by Engineer-in-charge.  151 S&F in repair Plastic Surface mounting box 3 / 4 module gang box for mounting switches, sockets, fan regulator etc complete all as directed by Engineer-in-charge.  152 S&F in repair Plastic Surface mounting box 6 / 8 module gang box for mounting switches, sockets, fan regulator etc complete all as directed by Engineer-in-charge.  153 Supply & replacement of3 mm thicklaminated mica sheet top cover suitable for switch board 3 way to 6 way including removing & re-fixing of existing switch / socket and complete connection all as directed.Note :- Replacement of unserviceable switch / socket / regulator shall be measured & Paid separately  154 Supply & replacement of3 mm thicklaminated mica sheet top cover suitable for switch board 8 way to 12 way including removing & re-fixing of existing switch / socket and complete connection all as directed.Note :- Replacement of unserviceable switch / socket / regulator shall be measured & Paid separately.  155 S&F in repair LED bollard light fitting 10 W, with PC diffuser, made up of MS pipe,IP-65 rated, inetgrated electronic driver, energy efficient complete with all accessories and connection, internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size all as specified and directed.  156 M&L forModular metalflush box 1/2 Module complete all as specified and directed.  157 M&L forModular metalflush box 3 Module complete all as specified and directed.  158 M&L forModular metalflush box4 Module complete all as specified and directed.  159 M&L forModular metalflush box6 Module complete all as specified and directed.  160 M&L forModular metalflush box8 Module complete all as specified and directed.  161 M&L for modular white cover plate with frame, 1 / 2module complete all as specified and directed.  162 M&L for modular white cover plate with frame, 3 module complete all as specified and directed.  163 M&L for modular white cover plate with frame, 4 module complete all as specified and directed.  164 M&L for modular white cover plate with frame, 6 module complete all as specified and directed.  165 M&L for modular white cover plate with frame, 8 module complete all as specified and directed.  166 M&L for point wiring with 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Casing and Caping and its all accessories of suitable size on wall/roof surfaces ( making good all to the disturbed surfaces as per existing) including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing includinggang box / 2.0mm thick MS terminal box as per site requirement for fixing switches, sockets, fan regulators etcfixed to wall with 3mm thick laminated sheet top cover complete all as specified forfor item no 169, 170 and 171:-  167 a)One light point/ fan point / bell pointcontrolled by one switch  168 b)One 3 pin 5 Amps socket point controlled by one way switch on same board.  169 c)One 3 pin 5 Amps socket point controlled by one switch on independent board  170 All as per item No. 168 here-in-before but with 4.0 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 4.0 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.  171 S/F switch piano type , SP, one way, flush type 5 Amps complete all as specified.  172 S/F socket out let 2 in 1 flush type 5 pin 5 Amp complete all as specified.  173 S/F socket out let 2 in 1 flush type 3 pin 5 & 15 Amp complete all as specified.  174 S/F switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified.  175 S/F fan Regulator piano flush type, electronic step type complete all as specified.  176 Supply and Fixing in repair modular switch 6 Amps single pole one-way, 1 Module complete.  177 Supply and Fixing in repair Modular switch16 Amp single pole one way,1 Module all as specified.  178 Supply & Fixing in repair modular fan Regulator electronic step type complete all as specified.  179 Supply and Fixing in repair modularsocket2-in-1, 5 pins 6 Amps , combined 2 Modulecomplete.  180 Supply and Fixingin repair modular socket 2-in-1,3 and5 pins 6 /16 Amps, combined 2 Module complete all as specified.  181 S&F in repiar Modular AC Box Plastic enclosure, heavy duty with single pole MCB 20 amps c series and plug top complete as directed.Make: Anchor Cat part No 98488 or equivalent  182 Supply & fix in replacement of indoor wall mounted fitting, brushed nickel finish fixture with opal glass diffuser, with LED retrofit bulb of capacity 09 watts-02 Nos all as directed at site. Make:-Havells Cat Part No. FLORETINE WL 2LS B22 SS or equivalent make in Crompton/ Philips C&S.  183 Taking down carefully service connection of any type complete all as directed by Engineer-in-Charge.  184 Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables and getting out all as specified and as directed by Engr-In-Charge.  185 Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all asspecified.  186 Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified.  187 Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor laid in trenches / duct / fixing on walls / poles or passing through HDPE double wall corrugated pipe (outer dia should not be less then 40 mm) including connecting with suitable lugs, glands, nuts and bolts in existing Panelfrom pole / Main Panel Box and testing complete all as specified and directed of following (ITEM NO 189-190) sizes :-Note:- HDPE pipe rate shall be deemed in quoted rate above.  188 LT XLPE cable size 10 sq mm 2 core  189 LT XLPE cable size 16 sqmm 4 core  190 Supply & fixing powder coated CRCA steel sheet MCB distrbution board, IP-43 IK-09 protection, double door recess mounted, triple pole and neutral 4 way with 100 Amps rated copper bus bar, type complete all as directed.  191 Supply & fix in replacement of MCB TPN40 to 100 Amps, C series , bracking cap 10KA, 415V complete including taking down old MCBsall as specified and directed.  192 S&F TP&N Vertical Loadline distribution board, 4 Way, Double door, sheet steel, phosphatised, powder painted withbus-bar 200Amp, neutral link, earth bar and din rail ,blanking Plates, cable ties for cable management, 440 V, 4 way complete all as specified including fitting suitable for MCBs with connections complete all as specified and directed.Note : -MCB & MCB /MCCB DBs shall be of same make and measured and paid seperately under respective items of Sch A. DB shall be fixed in flush pattern by cutting the wall and making good disturbed surface as pe directed & rate shall be included in the items.  193 Supply & fix in replacement of MCCB250 Amps, thermal magnetic based adjustable type, breaking cap 36 KA, 4 Pole, 415V complete including taking down old MCBsall as specified and directed.  194 Supply & fix in replacement of MCCB160 Amps, breaking cap 25 KA,4 Pole, 415V complete including taking down old MCBs all as specified and directed.  195 Supply & fix in replacement of MCCB125 Amps, breaking cap16 KA, 4 Pole, 415V complete including taking down old MCBs all as specified and directed.  196 S&F in repair driver suitable for existing LED panel light fittings, 36 watt as directed.  197 S&F in repair driver suitable for existing LED down light fittings 15 watt as directed.  198 Earthing complete all shown as electrical plate No -03 of MES Sch part -I as specified and as directed including the following:- (i)GIearth plate of size 60x 60cm x6.0mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.50 metres below ground level. (ii)Earth plate surrounded by and packed with charcoal and common salt in alternative layers. ( n.exc 15 cms each layer)(iii)4 mm GI wire from earth plate to MCB DB/machineryincluding necessary GI bolts, nuts check , washers, thimbles etc.(iv)20 mm bore, light grade, Gi pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontaly to the earth pit.(v)15 mm dia bore G. I. medium grade pipe for protection of earth wire.(vi)Cement concrete chamber of PCC (1:3:6) type C-2 using 40mm graded stone aggregate. The chamber shall be constructed one metre away from edge of earth pit.(vii) 50 mm thick precast cover of reinforced cement concrete(1:2:4) type B-1 using 20mm graded stone aggregate with steel rainforcement 8 mm dia mild steel TMT bar @ 10 Cm c/c both ways and MS angle iron 50x50x6mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces with suitable handle to lift the cover. (viii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance of 50 m as directed.