Tender For Comprehensive Maintenance And Misc B/R And E/M Works At Jcos/Or Md Accn In Od Complex Under Age B/R Of Ge ( E ) Mathura;  1 M&L for preparation of old plastered surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed.  2 M&L for preparation of old plastered surface of ceiling and applying onecoats of white wash complete all as specified and directed.  3 M&L for complete removal of existing treatment& preparation of old plastered surface of wall and applying two coats of Distemper oil emulsion, white or tinted on old wall surface including 1 mm thick wall care putty on surfaces of wallcomplete all as specified and directed.  4 M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.  5 M&L for preparation of old painted steel surface of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.  6 Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises compete all as specified and as directed.  7 M&L for 25 mm average thick cement concret type- B0 1:2:4 (using 12.5 mm graded stone aggregate) as leveling course in floor compete all as specified and as directed.  8 M&L for Non Skid ceramic coloured tiles 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in cement motar1:4complete all as specified and as directed.  9 All as per item abovebut as in vertical surface laid over and including 10 mm thick rendering in cement motar 1:3. complete all as specified and as directed.  10 M&L forGlazed ceramic coloured tiles in vertical surface of size 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick rendering in cement motar 1:4 complete all as specified and as directed.  11 M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 018 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:6) all as specified and as directed by Engr -in-charge.  12 All as item no.above but as in skirting including 10mm thick rendering in CM 1:4 set and backing coat complete  13 Demolition of stone slabs/tiles of any description or thickness in floors/apron etc laid bedded and pointed in any mortar complete all as specified and as directed.  14 M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillar, window cills, cooking platform and like laid over and including 10mm thick screed bed in cement mortar 1:4 and pointing in white cement(1:2) using marbal dust with admixture of pigment to match the shade of granite complete all as specified and as directed.  15 Taking down cement plaster on brick or stone walls, concrete surface etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.  16 M&L for rendering 10 mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 finished even & fair complete all as specified and as directed.  17 M&L for rendering 5 mm thick in cement and sand mortar 1:3 on fair faces of concrete surfaces as in ceiling including finishing the surface even and smooth without using extra cement, complete all as specified and as directed.  18 M&L preperation of new plastered surfaces of walls and applying two coats of oil bound distember over a coat of alkali resistant primer over a coat of wall care putty not less than 3mm thick complete all as specified and as directed.  19 M&L for preparation of newly plastered surfaces of ceilingand applying three coats of white wash, complete all as specified and as directed.  20 S&F in repair25 mm dia stainless steel tubular drapery rod cut to size and fixed in position including fixing brackets stop roller end caps etc complete all as specified and as directed.  21 S&F in repair stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples complete as specified and as directed.  22 Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or from metal frame or stone or concrete or bricks surrounds glazed with putty, taking out old pins punching or drilling out, complete all as specified and as directed.  23 S&F4 mm thick sheet glass, ordinary quality and glazing with Putty/wooden beading in squaren exc. 0.5 square metre in each pane complete as specified and as directed.  24 Dismantling boarding as in kitchen cabinet, cup boards/shelfs/partitions in any position fixed with screws complete all as specified and as directed.  25 S&F 18 mm thick WPC board plain white fixed with each other using slovent cement/adhesive and machine screws as in back side of cupboard/kitchen cabinet etc complete all as specified and as directed.  26 S&F 18mm thick WPC board one side laminated and other side balance white as on side of cupboard/Kitchen cabinet including shelves, partition drawer etc fixed as directed with solvent cement/adhesive and machine screws PVC edging/beading of size 18x1mm thick having density 600kg/per cum shall be provided on front visible edges of board complete all as specified and as directed.  27 S&F in repair Magnatic catcher (KTS-20) full extension load capacity 8 kgs suitable for cup board/kitchen cabinet shutter complete all as specified and as directed.  28 S&F in repair stainless steel handles, cast type polished bright of 100 mm size for kitchen cabinet shutters complete all as specified and as directed.  29 S & F Continuous (piano) hinges, Width of flaps - 40 mm (when open), mild steel, bright finish or electrogalvanisecomplete all as specified and as directed.  30 Taking down chowkhat or frame with shutter (without taking off shutter from the frame) area not exc 1.5 Sqm each complete all as specified and as directed.  31 Taking down chowkhat or frame with shutter (without taking off shutter from the frame) Area exc 1.5 Sqm but n exc 4.00 Sqm each complete all as specified and as directed.  32 Taking down shutter of any description area exc 1.0 Sqm and n exc 2.0 sq. m each complete all as specified and as directed.  33 S&F Pressed steel frame for doors of size 125 X 60mm frabicated out & 1.25mm thick sheet with one or more rebates including necessary fixing lungs, hinges, lock strike plate, etc, supplied and fixed complete all as specified and as directed.  34 S&F Pressed steel framefor doors of size 105 X 60mm fabricated out & 1.25mm thick sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, supplied and fixed complete all as specified and as directed.  35 M&L for cement concrete 1:3:6 type C1(using 20 mm graded stone aggregate) as in bed blocks for fixing hold fasts and fillling of frames etc. complete all as specified and as directed.  36 S&F 30 mm thick, factory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides completeall as specified and as directed.  37 S&F 35 mm thick factory made second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and as directed.  38 M&L for prepration of new wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.  39 S&F Solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube completeall as specified and as directed.  40 S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and as directed.  41 S&F stainless steel wire cloth. 0.36 mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples complete as specified and as directed.  42 S&FSS hinges medium weightsize 100 mm, complete all as specified and as directed.  43 S&FAluminium handles, cast type, anodised of 150 mm size complete all as specified and as directed.  44 S&F aluminium anodized barrel tower bolts 200 mm length of bolt of extruded section and fixed complete all as specified and as directed.  45 S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts 250 mm long of extruded sections or cast aluminium alloyand fixed complete all as specified and as directed.  46 Taking up or down 15 mm bore steel tubing and connections including disconnection of fittings complete all as specified and as directed.  47 S&F steel tubing ,galvanised, medium grade 15 mm bore with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and as directed.  48 Taking up or down 20 mm bore steel tubing and connections including disconnection of fittings complete all as specified and as directed.  49 S&F steel tubing ,galvanised, medium grade 20 mm bore with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and as directed.  50 S&F in repair Sinks with drainage board made of stainless steel lmm thick for kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.  51 S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with stainless steel bracket guard & railing 60cm long complete all as specified and as directed.  52 S&F in repair Brass chromium plated shower rose 125mm size with or without swivel joints including arm complete all as specified and as directed.  53 S&f in repair 2 way bib cock cast copper alloy chromium plated with wall flange screwed to 15 mm bore dia pipe complete all as specified and as directed.  54 S&F in repairs stainless steel towel rail 600 mm long made out of 20mm stainless steel tube fixed with chromium plated brass screws and wooden/plastic cleats etc complete all as specified and directed.  55 S&F Towel Ring of stainless steel of standard size fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed.  56 S&F in repair bib tapscast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipes complete all as specified and as directed.  57 S&F in repair angular cock cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipescomplete all as specified and as directed.  58 S&F in repairPillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for 15mm bore dia iron pipe complete all as specified and as directed.  59 S&F in repair stainless steel hand jet Health faucet with 8 mm dia 1.2m long SS flexible tube and wall hook complete all as specified and as directed.  60 S&F stainless steel chromium plated Grating100 mm dia complete all as specified and as directed.  61 S&F PVC connection 15mm size with PTMT nut of length 600mm complete as specified and as directed.  62 S&F in repair PVC valveless syphonic action type flushing cistern (Low or high level) of 10 litre capacity, white/coloured with inlet ball valve, float, handle including fixing brackets and 32 mm bore PVC flush pipe etc complete all as specified and directed.  63 S&F in repair Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including setting the trap and pan in concrete, including 10 ltr capacity PVC valveless syphonic action type low level flushing cistern and 32mm dia PVC Flush pipe complete including jointing to socket of flushing rim complete all as specified and as directed.  64 S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white including Plastic water closet seat cover, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.  65 S&F in repair vitreous china wash hand basin white flat back size 550 x 400 mm excluding taps waste chain and plug including bracket complete all as specified and as directed.  66 M&L fordisconnecting existing tank capacity exc 500 & n exc 1000 ltr, setting aside for repairs, cleaning, etc and hoisting if required andreconnecting and re-fixing in position complete all as specified and directed  67 Demolition of roof treatment any thickness including PCC , Mud phuska PCC padding, plastering , APP membrane complete treatmentand in any position and removing the demolished material out of MoD land complete all as specified and directed.  68 M&L for cement concrete 1:2:4 type B-0 mix (12.5 mm graded stone aggregate) in padding over roof fo levelling coursecomplete all as directed.  69 M&Lfor APP based polymeric membrane not less than 3 mm thick, weighing not less then 3 kg / Sqm, reinforeced with polyster non-woven fabric (weighing not less than 150 gm/sqm). It shall be laid by torch application. Side overlaps shall be 75 mm and the ends shall be 100 mm and all overlaps and jointed shall also be sealed by torch application. For parapets, membrane shall be taken to a height of minimum 60cm and then inserted inside the parapet in a groove and same shall be flashed by membrane flashing. Complete APP membrane (in roof/parapet surfaces) shall be laid over and including a coat of cold applied bituminous primer confirming to IS:3384 @ 0.40 Kg per Sqm including laid over 10 mm thick cement plaster in CM 1:4, complete all as specified & directed.  70 M &L for Cement concrete plain tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry, laid overand including 15mm screed bedding layer in CM 1:4 and filling the 2mm wide joints of tiles with cementitious grouting material complete all as specified & directed.  71 Dismantling asbestos cement/Galvalume (corrugated or semi corrugated) sheets in roof coveringsincluding ridges, hips, valleys etc .complete all as specified and as directed. complete all as specified and directed..  72 M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified  73 M&L Pre- painted galvalume aluminium zinc coating GI basedsteel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpaas in ridges/valley gutters, fixed with self tapping screw as specified.  74 Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed.  75 Dismantling timber scantlings (framed work) exc 40 Sq Cmin section, in any position.  76 S&F rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections, ms hollow pipe) including distance pieces, cleatsetc. conforming to Fe-410W Gde E-250 quality A,complete all as specified and directed.  77 M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primercomplete all as specified.  78 Roughening / cleaning existing concrete surface by brushing with wire brushed for removing caked mud etc, sweeping with brooms and reomve all loose dirt etc  79 Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (Below or above ground level) complete all as specified and as directed.  80 M&L 75mm thickcement concrete 1:4:8 type D2 (using 40 mm graded aggregate) as in sub floors, sub bases, floors and paving etc, complete all as specified and as directed.  81 Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, best quality locally available confirming to IS 15658-2006, laid in required colour & pattern over and including 50 mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified and as directed.  82 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and as directed.  83 M&L 75 mm thick cement concrete 1:3:6type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/path laid in panel surface finished even and fair without using extra cement complete all as specified and as directed.  84 Taking downexisting copper / aluminium point wiring (Light / Fan / Socket or Power Point) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets), removing materials from site and making good the disturbed surfaces of walls, floors etc as per existing specification complete all as specified  85 Taking out existing copper/aluminium sub main wiring of any size and making good the disturbed surfaces complete all as specified and directed  86 Taking down MCB distribution boards with incoming and outgoing controls any make and capacity after disconnecting of electric connections complete all as directed.  87 M & L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed FRLS cable, multi-stranded, copper conductor, inuniversal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd)and its all accessories complete concealed in wall / roofincl cutting & chases( making good all to the disturbed surfaces as per existing) and including with modular flush metal boxes with modular cover plate and frame for mounting modular switches, socket, regulator etc andincluding earth wire ofPVC insulated FRLS copper conductor multistrandedof 1.5Sqmmsize in green colour for one light/fan/bell point controlled by one switch complete all asspecified as directed.  88 All as per item serial No 4.00 here-in-before but one 3 pin 5 Amps socket point controlled by one switch on independent board complete all as specified and as directed.  89 All as per item serial No 4.00 here-in-before but one 3 pin 5 Amps socket point controlled by one switch on same board complete all as specified and as directed.  90 All as per item serial No 4.00 here-in-before but one light point controlled by two way switch complete all as specified and as directed.  91 M & L for Point wiring with 2.5 Sqmm (nominal area) single core PVC insulated unsheathed FRLS cable, multi-stranded, copper conductor, inuniversal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd)and its all accessories complete concealed in wall / roofincl cutting & chases( making good all to the disturbed surfaces as per existing) and including with modular flush metal boxes with modular cover plates & frame for mounting modular switches, sockets, regulators etc andincluding earth wire ofPVC insulated FRLS copper conductor multistrandedof 2.5Sqmmsize in green colour for 15 Amps pointscomplete all as specified and as directed.  92 S & F switch modular type 6 Amps complete all as specified and as directed.  93 S&F socket outlet modular type 2-in-1, 3 Pin, 2 module 6 Amps 230 V complete all as specified and as directed.  94 S&F switch modular type, one module 16 Amps 230 V complete all as specified and as directed.  95 S&F socket modular type 2-in-1, 5 Pin, 6/16 Amps 2 module complete all as specified and as directed.  96 S&F modular bell push switch 6 A , 1 Module complete all as specified and as directed.  97 S&F modular switch 2 way 6 A , 1 Module complete all as specified and as directed.  98 S & F Modular step type electronic fan regulator2M 120Won theexistinglaminated sheet including taking down the old unserviceable one all as directed.  99 S & F in replacement switch modular type 6 Amps complete all as specified and as directed.  100 S&F in replacement socket outlet modular type 2-in-1, 3 Pin, 2 module 6 Amps 230 V complete all as specified and as directed.  101 S&F in replacement switch modular type, one module 16 Amps 230 V complete all as specified and as directed.  102 S&F in replacement socket modular type 2-in-1, 5 Pin, 6/16 Amps 2 module complete all as specified and as directed.  103 S&F in replacement modular bell push switch 6 A , 1 Module complete all as specified and as directed.  104 S&F in replacement modular switch 2 way 6 A , 1 Module complete all as specified and as directed.  105 S & Fin replacementModular step type electronic fan regulator 2M 120Won theexistinglaminated sheet including taking down the old unserviceable one all as directed.  106 M&L for Point wiring complete with 1.5 Sqmm single core PVC insulated (FRLS) cable 1100 volts grade with multi-stranded, copper conductor drawn through and including 20mm dia rigid non-metallic PVC conduit with all acessories such as internal bend end caps etc complete fixed on walls/ceiling/roof etc by means of suitable GI saddles/Spacers and including provision of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistrandered copper conductor cable as earth continuity conductor, fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls with 3mm thick bakelite top cover sheet ISI marked with chrominium plated screws and cup washers for one light/fan/bell point controlled by one switch complete all asspecified as directed.  107 All as per item serial No 23 here-in-before but one 3 pin 5 Amps socket point controlled by one switch on independent board complete all as specified and as directed.  108 All as per item serial No 23 here-in-before but one 3 pin 5 Amps socket point controlled by one switch on same board complete all as specified and as directed.  109 All as per item serial No 23 here-in-before but one light point controlled by two way switch complete all as specified and as directed.  110 All as per item serial No 23 here-in-before but Point wirng complete with 2.5 Sqmm single core PVC insulated (FRLS) cable 1100 volts grade with multi-stranded, copper conductor for 15 Amps point controlled by 15 Amps switch complete all as specified and as directed.  111 S & F switch piano flush type 5 Amps single pole one-way, complete all as specified.  112 S & F socket outlet flush type 2-in-1, 3 pins 5 Amps multipurpose complete all as specified.  113 S & F switch flush type 15 Amps single pole one-way complete all as specified.  114 S & F socket outlet flush type 2-in-1,3 and6 pins 15 Amps multipurpose complete all as specified.  115 S & Fswitch piano flush type 5 Amps single pole two-way, complete all as specified.  116 S & Fstep type electronic fan regulator (switch type ) on the existing phenolic laminated sheet complete all as specified and as directed.  117 S & F Bell Push switch flush type 6 Amps single pole one-way complete all as specified.  118 S & F in replacement switch piano flush type 5 Amps single pole one-way, complete all as specified.  119 S & F in replacement socket outlet flush type 2-in-1, 3 pins 5 Amps multipurpose complete all as specified.  120 S & F in replacement switch flush type 15 Amps single pole one-way complete all as specified.  121 S & F in replacement socket outlet flush type 2-in-1,3 and6 pins 15 Amps multipurpose complete all as specified.  122 S & F in replacementswitch piano flush type 5 Amps single pole two-way, complete all as specified.  123 S & F in replacementstep type electronic fan regulator (switch type )on the existing phenolic laminated sheet including taking down the old unserviceable one all as directed.  124 S & F in replacement bell Push switch flush type 6 Amps single pole one-way complete all as specified.  125 S & F in replacement Bell Multi Musictype,230 Volts complete with connection all as specified.  126 S & F in replacement ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified.  127 M & L for Sub Main Wiring with two runs single core 6 Sqmm PVC insulated unsheathed(FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 25mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 6 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge.(Note: Two runs 6 Sq mm (P&N),one run of 6 Sq mmearth wire & One run ofPVC conduitwill measured as one RM).  128 Supply & fixing indoor decorative ultra slim surface /Wall mounted LEDbatten tube light complete fitting 1x 20 watt LED Tube fitting withpolycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- relatedcolour temperature (CCT) of 6500K, >100 Lm/Wattcomplete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge.  129 Supply and fixLED T-5 Intergrated Batten PC housing extruded2light fittings 9Wcomplete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge.  130 S&F in replacement LED retrofit lamp 9 Watt.  131 S & F in replacement Lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specifed  132 S&F in replacement Decorative wall light fitting stainless steel rust free fixture with white glass diffuser with 7.5/ 9w LED lamp complete all as specified and directed.  133 S&F in replacement of environmental friendly, ultra modern, energy saving, surface mounted,LED Bulk Head fitting of 10 Watt complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size ofcomplete all as specified and as directed.  134 S&F in replacement of building street light fitting, IP66 powder coated pressure die cast aluminium with heat resistant toughened glass complete of 30 Watt capacity including fixing arrangement complete with all accessories including connecting up with twin core copper conductor cable with suitable size all as directed.  135 Material and labour for Earthing complete with GI earthplate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire 4.0 mm asearth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3of MES schedule Part-I and incl 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate,reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete.  136 S&F in replacement MCB distribution board, SPN 8 Way, Double door, sheet steel, phosphatised, powder painted withbus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified.  137 Supply & fixin replacementMCCB 4 pole 415 Volts, (Ics=100%Icu) Adjustable Thermal and fixed magnatic type 125 Amp,  C series , bracking cap 16KA, Complete all as spccified.  138 Supply & fix in replacement MCCB 4 pole 415 Volts, (Ics=100%Icu) Adjustable Thermal and fixed magnatic type 100 Amp,  C series , bracking cap 16KA, Complete all as spccified.  139 S & F in replacement MCB DP40 -63 Amps, C series , bracking cap 10KA, 240V complete all as specified and directed.  140 S & Fin replacement Single pole (SP) MCB 6-32 Amps, 240 V, 50Hz,10KA breaking capacityall as specified.  141 S & F in replacement capacitors 2.5 MFD suitable for all types of fans complete all as directed.Make: - Usha, Universal, Epcos.  142 Supply only MS louvers with nuts, bolts and washers suitable to exhaust fan upto 350 mm sweep of any description/make/model complete all as specified and directed by Engr-in-Charge.  143 S&FPVC insulated sheathed 1.5 sqmm 3 core cable 1100 volts grade ISI marked copper conductor complete.  144 S&FPVC insulated sheathed 2.5 sqmm 3 core cable 1100 volts grade ISI marked copper conductor complete.  145 Supply only down rod MS grade 15 mm bore of length upto 90 cm size for ceiling fans of any type and size including cutting, drilling holes, making thread and painting complete all as directed.  146 Supply and fixing in replacementstep type electronic fan regulator (socket type )on the existing phenolic laminated sheet including taking down the old unserviceable one all as directed.