Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L for conducting ‘B’ check ofDG set of capacity 40 KVAto carry out the following maintenance/servicing, complete all as specified and as directed :-(i) Change of diesel filter/oil filter, top up/replacement of engine oil, coolent if required. (ii) Check and clean engine, alternator battery,instrument panel, elect panel, timer, contactors, meters and others etc.(iii) Tightening of all nuts & bolts of DG set and its accessories.(iv) Check for any diesel lekage from any point and rectify if observed.(v)Check and adjust fan belt tension, replace the fan belts if found damaged.(vi) Check leakage of smoke from exhaust system/silencer, repair if required.(vii) Check electrical connections of engine. The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order(viii) Check and tighten the AVM pads, nuts and bolts,change AVM pads if found damaged. AVM to be provided by contractor.(ix) Check exhaust pipe,flange and lagging Repair if found damaged. (x) Check output of alternator, if found OK adjust the same to specified values in case of brush type. (xi) Checking of all hoses and cleanup,change/tighten if required.(xii) Checking of all hoses and cleanup if required. Also changing air filter elements,if required. (xiii)Oiling,Greasing and checking for proper & smooth functioning. etcand refitting, testing on load complete(xiv) Repair / Calibration of Injector complete all as specified and directed.(xv) Overhauling and testing of governor assembly including machine work Note 1. :- Price for minor spare parts and fuel filter, head/filter gasket, air filter, cleaning of radiator, fuel pipe, cleaning of nozzle, tapit setting included in the quoted rates against each capacity.Note 2. Price for major spare parts and coolent required for replacement shall be measured and paid separately under respective item of schedule. |
| 2 | All as per item No. 1.00 here in before but DG set capacity 62.5 KVA, complete all as specified and as directed. |
| 3 | All as per item No. 1.00 here in before but DG set of capacity 200 KVA, complete. |
| 4 | All as per item No. 1.00 here in before but DG set of capacity 250 KVA, complete. |
| 5 | All as per item No. 1.00 here in before but DG set of capacity 312.5 KVA, complete. |
| 6 | Supply only cylinder liner suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 7 | Supply only piston ring set suitable for DG engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 8 | Supply only piston pin suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 9 | Supply only piston circlips suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 10 | Supply only \"O\" seal ring, first groove suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 11 | Supply only \"O\" seal ring, 2nd & 3rd groove suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 12 | Supply only main bearing upper & lower suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 13 | Supply only oil seal ring suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 14 | Supply only radiator cap suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 15 | Supply only thrust bearing suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 16 | Supply only inlet/exhaust valvesuitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 17 | Supply only inlet/exhaust valve seat ring suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 18 | Supply only valve guide suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 19 | Supply only valve collet suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 20 | Supply only valve stem cap suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 21 | Supply only valve seal suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 22 | Supply only washer for cylinder head cover suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 23 | Supply only seal ring (rocker arm) suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 24 | Supply only water darin cock sub assy suitable for DG engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 25 | Supply only front oil seal suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 26 | Supply only rear oil seal suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 27 | Supply only connecting rod bearing suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 28 | Supply only connecting rod bush suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 29 | Supply only oil sump washer suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 30 | Supply only inlet pipe for feed pump suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 31 | Supply only V-belt suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 32 | Supply only copper washer suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 33 | Supply only HCT switch suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 34 | Supply only thermostat body suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 35 | Supply only radiator water inlet hose suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 36 | Supply only radiator water outlet hose suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 37 | Supply only thermostat element suitable for DG set engine 40 to 62.5 KVA, complete all as specified and as directed. |
| 38 | Supply only cylinder liner suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 39 | Supply only piston ring set suitable for DG set engine 200 KVA to 312.5 KVA, complete all as directed. |
| 40 | Supply only piston pin suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 41 | Supply only piston circlips suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 42 | Supply only O seal ring, first groove suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 43 | Supply only O seal ring, 2nd & 3rd groove suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 44 | Supply only main bearing upper & lower suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 45 | Supply only Oil seal ring suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 46 | Supply only Radiator cap suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 47 | Supply only Thrust bearing suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 48 | Supply only inlet/exhaust valvesuitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 49 | Supply only inlet/exhaust valve seat ring suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 50 | Supply only valve guide suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 51 | Supply only valve collet suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 52 | Supply only valve stem cap suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 53 | Supply only valve seal suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 54 | Supply only washer for cylinder head cover suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 55 | Supply only seal ring (rocker arm) suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 56 | Supply only water darin cock sub assy suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 57 | Supply only Front oil seal suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 58 | Supply only Rear oil seal suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 59 | Supply only connecting rod bearing suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 60 | Supply only connecting rod bush suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 61 | Supply only oil sump washer suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 62 | Supply only inlet pipe for feed pump suitable for Dgsetengine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 63 | Supply only V-belt suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 64 | Supply only copper washer suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 65 | Supply only HCT switch suitable for DG setengine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 66 | Supply only Thermostat Body suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 67 | Supply only Radiator water inlet hose suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 68 | Supply only Radiator water outlet hose suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 69 | Supply only Thermostat element suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 70 | Supply only AVR suitable for DG set engine 200 KVA to 312.5 KVA, complete all as specified and as directed. |
| 71 | Dismantling the weak self starter, 24 Volt, motor of capacity & make as taken out mentioned above, segregating serviceable and semi/unserviceable parts, cleaning serviceable parts, drying, lubricating. Reassembling the self starter motor with cleaned serviceable parts along with the new parts for armature and testing, complete all as specified and as directed. |
| 72 | All as per item No. 71.00 here in before but for armature brake spring and testing complete. |
| 73 | All as per item No. 71.00 here in before for bush set (set of 02 Nos) and testing complete. |
| 74 | All as per item No. 71.00 here in before but for bush spring and testing complete |
| 75 | All as per item No. 71.00 here in before but for bush holder and testing complete |
| 76 | All as per item No. 71.00 here in before but for bushing commutator end and testing complete. |
| 77 | All as per item No. 71.00 here in before but for Carbon bush set and testing complete. |
| 78 | All as per item No. 71.00 here in before but for Drive bushing pinion drive lever and testing complete. |
| 79 | All as per item No. 71.00 here in before but for End cap gasket and testing complete. |
| 80 | All as per item No. 71.00 here in before but for field coil set (set of 4 Nos) and testing complete. |
| 81 | All as per item No. 71.00 here in before but for magnetic switch and testing complete. |
| 82 | S & F rectangular 03 Nos CT analog with analog ammeter having dial range 0-150 Amp and connected with control panel cable not less than 1.5 Sqmm with number ferrul lugs etc, complete all as specified and as directed. |
| 83 | S & F rectangularanalog voltmeter having dial range 0-400 Volt and connected with control panel cable not less than 1.5 Sqmm with number ferrul lugs etc, complete all as specified and as directed. |
| 84 | S & F power pack, industrial type,150 AH, 12 Volt, 25 plate, along with copper lead and clamp, complete all as specified and as directed. |
| 85 | S & F power pack, industrial type,180 AH, 12 Volt, 25 plate, along with copper lead and clamp, complete all as specified and as directed. |
| 86 | M & L for repair of fuel injection pump/PT pump including dismanting the fuel injection/PT pump, segregating serviceable and semi/unserviceable parts, replace all unserviceable parts and cleaning serviceable parts,drying,lubricating,re-assembling the FIP/PT pump with cleaned serviceable parts along with new parts as required, calibration, testing complete on computerised testing equipment, complete all as specified and as directed. |
| 87 | M & L for repair of alternator 3 Phase 440V of capacity 40 to 62.5 KVA, including dismantling the alternator from its mounting by unscrewing the nut & bolts. Cleaning the whole assy of alternator, replace the commutator, carbon brush, rectifier, slip rings, slip ring end bearing, drive end bearing etc and re-assebling the all parts and mounted the alternator on its same place and do the connection as previous, complete all as specified and as directed. |
| 88 | All as per item No.87.00 here in before but capacity 200 KVA to 312.5 KVA, complete. |
| 89 | M & L for rewinding of stator/rotor coil of alternator coil unit of capacity 63 KVA DG set with super enameled/paper coated copper wire of existing gauge including all connected insulating materials such as separator etc, varnishing, replacement of carbon bushes including disconnecting/dismantling of electrical connections, foundation bolts, pulling out of rotor with proper care and reinsulating of burnt out rotor/stator after rewinding work including re-assembling and testing, complete all as specified and as directed. |
| 90 | S & F in replacement power contactor for AMF panel, capacity 400 Amp, 4 pole, after dismantling existing contactors from panel and connecting new contactors and making connection with incoming and outgoing MCCB, complete all as specified and as directed. |
| 91 | M&L for earthing of equipment with copper earth plate electrode 60 × 60cm × 3.00mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel in any type of soil, connected to earthing test point and and necessary excavation and earth work, PCC (1:2:6) type C-1 as earth pit with pre-cast RCC (1:2:4) type B-1 cover slab size 400 x 400 x 50mm reinforced with 8mm dia TMT bar, 100mm c/c both ways including one handle made of 12mm dia including providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect, including Copper earth strip 25 x 3.00mm, protected by 40mm bore (light grade) galvanized iron pipe up to earthing test point including disposal of soil to a distance not exc 50 mtr and necessary testing on completion including taking out/dismantling of old unserviceable earthing of any descriptio, complete all as specified and directed.Note:- (i) Proper earthing pit should be provided with pit cover.(ii) Copper earth strip beyond 7.5 mtr shall be measured and paid seperately. |
| 92 | S&F in replacement of copper earth strip of size 25 x 3.00mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required, complete all as specified and directed. |
| 93 | M & L for repair of AMF panel controller suitable for DG set of capacity 40 KVA to 62.5 KVA, complete all as specified and as directed. |
| 94 | M & L for repair of AMF panel controller suitable for DG set of capacity 200 KVA, complete all as specified and as directed. |
| 95 | M & L for repair of AMF panel controller suitable for DG set of capacity 250 KVA, complete all as specified and as directed. |
| 96 | S&F in repairfully automatic (FASD) star delta starter along with single phase preventor in powder coated enclosure with PU gasket suitable for 3 HP submersible motor including all electric connection with ammeter and volt meter on/off & trip indicator including protection against phase failure, phase imbalance, phase reversal, complete all as specified and directed. |
| 97 | S&F in repairfully automatic (FASD) star delta starter along with single phase preventor in powder coated enclosure with PU gasket suitable for 6 HP to10 HP pump including all electric connection with ammeter and volt meter on/off & trip indicator including protection against phase failure, phase imbalance, phase reversal, complete all as specified and directed. |
| 98 | S&F in repair telescopic rode 5 - 10m with handle and adaptor, as per existing, complete all as specifiied and directed. |
| 99 | S&F in repair for leaf rakes net made in polypropelene and white polyester netting clip type connection, as per existing, complete all as specifiied and directed. |
| 100 | S&F in repair for curved brush made inpolypropelene and white polyester netting clip typeconnection, as per existing, complete all as specifiied and directed. |
| 101 | S&F in repair pump impeller (plastic), as per existing, complete all as specifiied and directed. |
| 102 | S&F in repair pumpfan with cover, as per existing, complete all as specifiied and directed. |
| 103 | Supply, installation, testing & commissionig pre-filter basket, as per existing, including taking down old unserviceable one, complete all as specifiied and directed. |
| 104 | Supply, installation, testing & commission 75mm bore ball valve, as per existing, including taking down old unserviceable one, complete all as specifiied and directed. |
| 105 | Supply, installation, testing & commission 100mm bore ball valve, as per existing, including taking down old unserviceable one, complete all as specifiied and directed. |
| 106 | Supply, installation, testing & commission 75mm bore non CI returnvalve with flanges and adaptor, as per existing, including taking down old one, complete all as specifiied and directed. |
| 107 | Preventive maintenance of swiming pool comprising of 02 Nos centrifugal pump of 10 HP (01 main pump & 01 stand by pump) and 01 No. of vacuum pump, sand filter (02 Nos), electric dosing pump (01 No), microprocessor based constant current technology water disinfector work is to be carried out, with prior intimation, in everymonth, complete all as specifiied and directed.Note-Fixing & testing chargesfor item No 107.00 to 109.00 shall deemed to be included in the unit quoted rate of item No. 106.00. |
| 108 | Supply only testing kit for test of PH, PPM, complete all as specifiied and directed. |
| 109 | Supply only TCCA 90bagof 50 Kg, as per existing, complete all as specifiied and directed. |
| 110 | Supply only algaecide bag of 12 ltr box, as per existing, complete all as specifiied and directed. |
| 111 | S&F in repair under water light LED light6 W, 12V including all necessary fitting, complete all as specifiied and directed. |
| 112 | S&F in repair 300 VA transformer suitable for under water light, as per existing, complete all as specifiied and directed. |
| 113 | Supply and filling in replacement gravel size 1-2mm in sand filter including removing out old gravel from the filter, complete all as specifiied and directed. |
| 114 | Supply and filling in replacement sand 0.4 to 0.8mm in sand filter including removing out old sand from the filter, complete all as specifiied and directed. |
| 115 | Disconnecting all electric and water supply connections and other related items and lifting the unserviceable non clog Submersible motor and pump of capacity 7.5HP, 3 phase, 415 V,from sewage sump by mechanical/manual method and dismantling the column pipe line, shafts stage and keeping the same in safe custody for reuse including transportation of the defective pump set and motor from pump house to workshop for repair and back and lowering and re-installation the same on exisisting position after necessary repair including testing on completion, complete all as specified and directed.(Note : Cost of repair including testingshall also deemed to be included in the unit quoted rate.) |
| 116 | Dismantling the unserviceable parts and burnt out copper winding from pump and motor of capacity 7.5 HP, 3 phase, 415V, and rewinding the motor with supper enamelled copper wire of suitable gauge including heating, varnishing, replacement of defective spare parts, re-assembling and painting the motor with two coats of supper enamelled paint and carrying out necessary tests in presence of Engr-in-Charge at site, complete all as specified and directed.(Note:- (i) Spare/parts, copper winding wire shall bemeasured & paid seperately as \"supply only\" under respective items. (ii) Labour charge for fixing parts shall deemed to be included in the unit rate.) |
| 117 | Supply only copper winding wire with supper enamelled copper wire of suitable gauge as per capacity/rating of motor, complete all as specified and directed. |
| 118 | Taking down the unserviceable parts from the non clog submersible pumpof capacity 7.5 HP, 3 phase, 415 V including over hauling, servicing/cleaning throughly discharge/suction cases, impellers, shaft and re-assembling pump carefully including servicing,cleaning and painting the parts with two coats water proofing supper enamelled paint after preperation of surfaces manualy including repair/replacement of unservicable parts as required at site etc and re-assembling/re-installing the pump, complete all as specified and directed.Note:- (i) Spare/parts shall be measured & paid seperately as \"supply only\". (ii) Labour charge for fixing parts shall deemed to be included in the unit rate. |
| 119 | Supply only ball bearing for non clog submersible motor as per existing, complete all as specified and directed. |
| 120 | Supply only mechanical seal for non clog submersible motor as per existing, complete all as specified and directed. |
| 121 | Supply only hydraulic oil for non clog submersible motor as per existing, complete all as specified and directed. |
| 122 | Supply only impeller as per existing, complete all as specified and directed. |
| 123 | Supply only impeller key as per existing, complete all as specified and directed. |
| 124 | M & L for machine work to the worn out portion ofnon clog submersible pump shaft of capacity 7.5 HP capacity including metalling,cutting,polishing and checking the accuracy on the lath machine, complete all as specified and directed. |
| 125 | Dismantling the induction motor from sewage sump/STP taking out burnt out winding wire from the stator of induction motor upto 3 HP and 1450 RPM of any make and rewinding with super enameled copper wire of appropriate size and number of turns as per manufacturers specifications including heat varnishing and testing of 3 phase, 415/440 voltand refixing after repair, complete all as specified and directed.Note:- (i) Copper winding wire shall bemeasured & paid separately as \"supply only\". (ii) Labour charge for fixing parts and transport shall deemed to be included in the unit rate. |
| 126 | All as per item No 125.00 here-in-before but for 5 HP induction motor, complete all as specified and directed. |
| 127 | All as per item No 125.00 here-in-before but for 10/12.5 HP induction motor, complete all as specified and directed. |
| 128 | Taking out vertical non-clog pump set upto 10 HP capacity from sewage sump/STP, dismantling pump complete after disconnecting all electrical connections and repair/overhauling including replacement of worn out parts, complete all as specified and directed. Note :(i)Spares/ parts required for replacement shall be measured and paid as Supply only. (ii) Re-assembling, lowering in sewage sump to its original place, testing and transport will be included in the unit quoted rate. |
| 129 | Supply only gun metal bush of vertical non-clog pump sets upto 10 HPcapacity, complete all as specified and directed. |
| 130 | All as per item No. 129.00 here-in-before butimpeller, complete all as specified and directed. |
| 131 | All as per item No. 129.00 here-in-before butimpeller key, complete all as specified and directed. |
| 132 | All as per item No. 129.00 here-in-before but neck ring (bronze), complete all as specified and directed. |
| 133 | All as per item No. 129.00 here-in-before but guide ring, complete all as specified and directed. |
| 134 | All as per item No.129.00 here-in-before but lock bolt for impeller , complete all as specified and directed. |
| 135 | All as per item No. 129.00 here-in-before but shaft sleeve, complete all as specified and directed. |
| 136 | All as per item No. 129.00 here-in-before but oil seal for L B H, complete all as specified and directed. |
| 137 | All as per item No. 129.00 here-in-before but oil seal for I B H, complete all as specified and directed. |
| 138 | All as per item No. 129.00 here-in-before but grease pot for ball bearing, complete all as specified and directed. |
| 139 | All as per item No. 129.00 here-in-before but shaft coupling (screwed), complete all as specified and directed. |
| 140 | All as per item No. 129.00 here-in-before but couplingpin & bush, complete all as specified and directed. |
| 141 | All as per item No. 129.00 here-in-before butball bearing, complete all as specified and directed. |
| 142 | All as per item No. 129.00 here-in-before but engine oil, complete all as specified and directed. |
| 143 | All as per item No. 129.00 here-in-before but lock bolt for shaft coupling, complete all as specified and directed. |
| 144 | All as per item No. 129.00 here-in-before but top shaft, complete all as specified and directed. |
| 145 | Taking out centrifugal non-clog horizontal type pump from STP repair/overhauling/servicing of pump set by dismantling all components, re-metalling of worn out portion of shaft and grinding/polishing, replacement of bush, gland packing, gland studs, impeller key including filling of fresh lubricating oil in pedestal bearing oil chamber up to required level and greasing of bearing at non-diving end pump capacity upto 12.5 HP, complete all as specified and directed.Note : (i) Spares/parts required for replacement shall be measured and paid as \"Supply only\". (ii) Re-assembling, lowering in sewage sump to its original place , testing and transport will be included in the unit quoted rate. |
| 146 | Supply only bearing ring for suction cover for horizontal pump sets upto 12.5HP capacity, complete all as specified and directed. |
| 147 | All as peritem No. 146.00 here-in-before but gasket (asbestos), complete all as specified and directed. |
| 148 | All as peritem No. 146.00 here-in-before but gland cover with stuffing box, complete all as specified and directed. |
| 149 | All as peritem No. 146.00 here-in-before but gland packing (5 Nos in one set), complete all as specified and directed. |
| 150 | All as peritem No. 146.00 here-in-before but ball bearing (N.D.E), complete all as specified and directed. |
| 151 | All as peritem No. 146.00 here-in-before but thrust bearing (D.E), complete all as specified and directed. |
| 152 | All as peritem No. 146.00 here-in-before but grease cup, complete all as specified and directed. |
| 153 | S&F in repair rubber coupling/spider coupling, flexible type suitable for upto 10 HP pump set, complete all as specified and directed. |
| 154 | S&F in repair DOL starter along with single phase preventor in sheet steel encloser,3 phase 415 Volt, with contactor suitable for 1 to 6 HP electric motor, complete all as specified and directed |
| 155 | Repair/servicing of existing sluice valve of 100mm bore after dismantling of upper cover, remove the spindle and make it leak proof by replace the gland packing ,nut bolt with washer and gasket of both side, complete all as specified and directed. |
| 156 | Repair/servicing of existing sluice valve of 150mm bore after dismantling of upper cover, remove the spindle and make it leak proof by replace the gland packing ,nut bolt with washer and gasket of both side, complete all as specified and directed. |
| 157 | Taking out primary and secondary bio filters assembly complete for overhauling dismantling its components, replacing of gaskets, applying of grease to the steel balls, replacing of U/S steel ball,and re-assembling after completion of overhauling,complete all as specified and directed. |
| 158 | Bailing out the sludge/containminated water (organic or inorganic) including other foreign materials fromsewage sumps of various sizes and depthsas required by pumping with suitable pumping machinery and removing the same within 50m distance and disinfecting the area with sufficient quantity of bleaching powder andincluding removing and refixing of manhole covers as required, complete all as specified and directed.Note: (i) Temporary barricade and providing sufficient bleaching powder shall deemed to be included in the unit quoted rate.(ii) Hiring charges and cost of fuel for sewage pump shall deemed to be included in the unit quoted rate.(iii) The operation shall be carried out once in every three months and every time shall be measured and paid saperately. |
| 159 | Taking out/bailing out the sludge/semi solid materials including other foreign materials fromsewage sumps of various sizes and depths as required by pumping with suitable pumping machinery and taking out sludge/semi solid materials/any other foreign materials from septic tanks etcand removing the sludge within 50m distance and deposited in a pit to be excavated and disinfectingthe area with sufficeint quantity of bleaching powder over the earth fill and covered with earth filling upto 30cm depth of pit including removing and refixing of manhole covers as required, complete all as specified and directed.(Note: (i) Excavation and earth work for pit, bamboo matting, temporary barricade of the pit and providing sufficient bleaching powder shall deemed to be included in the unit quoted rate. (ii) Hiring charges and cost of fuel for sewage pump shall deemed to be included in the unit quoted rate.(iii) The operation shall be carried out once in every three months and every time shall be measured and paid saperately. |
| 160 | Surface dressing n. exc. 15cm deep in soft/loose soil removing shrubs, small trees of height upto 1m, removing the the grass and creepers from root and spraying grass killing chemical (GLYCEL 41% SL or similar chemical as approved by Eng-in-Charge) with spray gun, as per manufacturer\"s instructions for prevention of weeds and grass at surrounding of STP, removing of waste materials and grasses n. exc 50m distance from installations, depositing where directed at a level n. exc. 1.5m above the starting points, complete all as specified and directed.Note : The cleaning can be carried out not more than twice at same loction/installation during the currency of contract, subject to atleast 4 months gap. |
| 161 | S&F PVC insulated, PVC sheathed, stranded copper conductor FR cable as inflat submersible water proof cable of size 6 Sqmm 3 core 1100 volts grade including taking down old unserviceable cable, complete all as specified and directed. |
| 162 | M&L for testing and submit raw sewage water and treated water and submit the following test results:- (a)Samples to be taken from sewage pumping station Near Bala Ji Mandir, Near DSC accn, Near R S Ground, Near FWC & treated water fromMain STP .(b) Submit all samples at the nearest Govt Test lab.The test for the following parameters has to be carried out:-(i) BOD (ii) COD (iii) Oil & Grease (iv) PH Value (v)TSS (vi) Feacel Colliform (vii) Residule chlorine (c) Submit the test report duly signed by appropriate Govt authority in every three month, complete all as specified and directed. |
| 163 | M&L for earthing complete with GI earth plate electrode 60 × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work PCC (1:3:6) type C-1 as earth pit with pre-cast RCC (1:2:4) type B-1 cover slab size 400 x 400 x 50mm reinforced with 8mm dia TMT bar, 100mm c/c both ways including one handle made of 12mm dia including providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect, including galvanised iron earth strip 25 x 3mm, protected by 40mm bore (light grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc. 50 mtr and necessary testing on completion, complete all as specified and asdirected.Note : Proper earthing pit should be provided with pit cover. |
| 164 | All as per item No 163.00 here-in- before but using GI earth lead wire 4.00mm dia with GI protection pipe 15mm bore light grade, complete all as specified and directed. |
| 165 | Taking out existing boulders (75 to 200mm size) complete from primary bio filter bed of dia 8.20m, depth of bouldersbed 1.6m, cleaning the boulders using fresh water, cleaning bottom surface of the filter bed and re-filling the filter bed after cleaning boulders and removing thewastage/sediments out side defence land, complete all as specified and direccted. |
| 166 | All as per item No 165.00 here-in- before but from secondary bio filter of dia 10.10m and depth of boulders 1.6m, complete all as specified and directed. |
| 167 | Supply and lay boulders of size 75mm to 200mm in primary and secondary bio - filters, complete all as specified and directed. |
| 168 | Supply and spreading unslaked lime at surrounding of pump house to destroy the roots of grass and herbs (average 300 gm per Sqm), complete all as specified and directed. |
| 169 | S&F in repair on-off push button pendants with elements red /green/orange, complete all as specified and directed. |
| 170 | S&F MCB Single Pole & Neutral (SPN) of capacity 40 to 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, as per IS/IEC 60898-1, fixedin proper position, complete all as specified and directed. |
| 171 | S&F MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, as per IS/IEC 60898-1, fixedin proper position, complete all as specified and directed. |
| 172 | Note: An amount of Rs.58,447.00 on account of Credit Schedule for schedule \"A\" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
| 173 | Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail