| 1 | Taking down carefully (aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete removing material to store of keeping in safe custody or for taking creditand making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 2 | M&L for point wiring with single core FRLS-PVC insulated unsheathed 1100 volt grade cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) drawn through and including stove enamelled steel conduit medium grade ISI marked not less than 20 mm dia concealed in wall with cutting chasing and making good the disturbed surface of wall with all fittings including tee, junction boxes andcontinuous earth wire with and including FRLS PVC insulated unsheathed 1100 volts grade cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) connected to earth dolly, one light point control by one switch complete all as specified anddirected. |
| 3 | M&L for point wiring with single core FRLS-PVC insulated unsheathed 1100 volt grade cable with multi stranded copper conductor of size 2.5 sqmm (Nominal area) drawn through and including stove enamelled steel conduit medium grade ISI marked not less than 20 mm dia concealed in wall with cutting chasing and making good the disturbed surface of wall with all fittings including tee, junction boxes andcontinuous earth wire with and including FRLS PVC insulated unsheathed 1100 volts grade cable with multi stranded copper conductor of size 2.5 sqmm (Nominal area) connected to earth dolly complete for one light point control by one switch complete all as specified anddirected. |
| 4 | S&F in replacement Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified anddirected. |
| 5 | S&F in replacementflame proof switch socket & plug combined in LM6 cable termination box in LM6 250 V, 16A, 2P+ earth complete all as specified anddirected. |
| 6 | S&F in replacement flame proof switch socket & plug combined in LM6 cable termination box in LM6 500V , 32A, 3P+ earth complete all as specified anddirected. |
| 7 | S&F in replacement LED light fitting 2X16Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessoriesprewired and including connecting up with threecore flexible copper conductor cable with suitable size complete all as specified anddirected. |
| 8 | S&F in replacement LED light fitting 1X16Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified anddirected. |
| 9 | S&F in replacementof Flameproof cum Waterproof LED Bulk Head light fitting of 30 W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen \"A\" clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified anddirected. |
| 10 | M&Lsub main wiring with two runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 6 sqmm and drawing through in concelead rigid metallic steel conduit pipeheavy duty in suitable size with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 6 sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring complete all as specified anddirected.Note : (i) Three run of 6 sqmmwith one run of steel conduit pipe shall be measured agaist one unit. (ii)Cost of cutting /cheasesing / plastering /distempering making good surface to match existing finishes. |
| 11 | M&Lsub main wiring with two runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 4 sqmm and drawing through in concelead rigid metallic steel conduit pipeheavy duty in suitable size with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 4 sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring complete all as specified and as directed. Note : (i) Three run of 6 sqmmwith one run of steel conduit pipe shall be measured agaist one unit. (ii) Cost of cutting /cheasesing / plastering /distempering making good surface to match existing finishes. |
| 12 | S&F sheet metal enclosuredistribution board TPN, 4 poles, double door, 4 way with 200 Amps ratedbus bar vertcal type withMCCB 4 pole 100 Amps 415 volt thermal megnatic base operated as incomer incl concealed in surface of wall and making all connection using gland , thembles in required size including taking down to old unserviceable DBs in any make/ model/ way etc with accessories complete all as specified and directed.Note: Quoted rate shall be included cost of MCCB , cutting plastering , colouring to surface of wall to be concealedetcall site requiredmatching with existing surface. |
| 13 | S&F sheet metal enclosure for MCB distribution board SPN, double door, 8 way with 200 Amp rated bus bar 230 Volts including taking down to old unserviceable DBs in any make/ model/ way etc with accessoriescomplete all as specified and directed. |
| 14 | S&F sheet metal enclosure for MCB distribution board SPN, double door, 4 way with 200 Amp rated bus bar 230 Volts including taking down to old unserviceable DBs in any make/ model/ way etc with accessoriescomplete all as specified and directed. |
| 15 | S&F toMCCB, 415 volt TPN 4 poles 63 Amps ,16 KA breaking capacity, thermal based adjestable type complete all as specified and directed. |
| 16 | S&F MCB , SPN, 2 pole 220 volts, 63 Amps , \"C\" Curve 10 KA complete all as specified and directed. |
| 17 | S&F MCB , SPN, 2 pole 220 volts, 32- 40 Amps , \"C\" Curve 10 KA complete all as specified and directed. |
| 18 | S&F MCB , single pole215 volts, 06- 32 Amps , \"C\" Curve 10 KA complete all as specified and directed. |
| 19 | M&L for point wiring includingconcealed in surface of structure/ truss etc rigid non-metallic PVC conduit pipe medium grade, ISI marked heavy duty in size 20 MM diawithtwo runs1.5 Sqmm FRLS insulated unsheathed, multi stranded copper conductor cable, single core 1100 volt grade with flush cast iron/ pressed steel terminal boxes of suitable size for fixingsuch as switches, sockets and fan regulators etc with modular cover plate and fixing with brass screws/cup washer and including FRLS insulated & unsheathed 1100 volts grade cable with one core multi stranded copper conductor of size 1.5 Sqmm as contineous earth wire complete including making good the disturbed surfaces for the following:- Note:-Quoted rate shall be included cost of cheasesing,cutting, plastering and colouring etc to surface of wall / beam/ roof etc as site requiredmatchingwith existing surface and blank plate to be cover up to extra gap in mountingboard in given module /make / model etc complete all as specified and directed. |
| 20 | All as per item No 19.00 above but one light/ fan point controlled by one way indepdentswitch complete all as specified and directed. |
| 21 | All as per item No 19.00 above butone 3 pin 5 Amps socket out let point on same board controlled by one switch complete all as specified and directed. |
| 22 | All as per item No 19.00 above butone 3 pin 5 Amps socket out let point on independent board controlled by one switch complete all as specified and directed. |
| 23 | All as per item No 19.00 above butpoint wiring for 15 Amps socket using 2.5 Sqmm copper cable for phase and neutral and 2.5 Sqmm as earth wire complete all as specified and directed. |
| 24 | All as per item No 19.00 above but power point wiring using two run 4 Sqmm copper conductor cable FRLS insulated unsheathed and unsheathed copper conductor of 4 Sqmm as earth wire complete all as specified and directed. Note : All circuit shall be taken from seprate control DBs (connected with energy meter)to be connecting individual power load. |
| 25 | S&Fsheet metal enclosure, Single pole and neutral with a two pin and earth plug and socket for AC box complete with one single pole MCBfor 240V, 20Amp complete all as specified and directed. |
| 26 | M&L for point wiring in PVC Casing & Caping single corePVC insulated unsheathed 1100 volt grade FRLS cable two run with multi stranded copper conductor of size 1.5 sqmm (Nominal area) , fixed on walland on ceiling with GI saddles, GI screws, rowel plugs with all fittings including tee, junction boxesand drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) connected to earth dolly complete all as specified and directed. |
| 27 | All as per item No 21.00 above but one light point or one fan point controlled by one switch complete all as specified and directed. |
| 28 | All as per item No 21.00 above but one 3 pin socket outlet, 5 Amps on the same boardother switches complete all as specified and directed. |
| 29 | All as per item No 21.00 above but one 3 pin socket outlet, 15 Amps on the independent board with2.5 sqmm copper conductor size other switches complete all as specified and directed. |
| 30 | S&F switch piano, flush type, single pole, one way 5 Amps complete all as specified and directed. |
| 31 | S&F socket combination 2 in 1, 5 pin 5 Amps flush type complete all as specified and directed. |
| 32 | S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed. |
| 33 | S&Fmodular bell push6 Amps one module complete all as specified and directed. |
| 34 | S&Fflush type bell push6 Amps one module complete all as specified and directed. |
| 35 | S&F in replacement bell ding dong type AC 230 volts single pole complete all as specified and directed. |
| 36 | S&F ceiling rose surface type 65 MM x 50 MM, 2 to 3 terminal complete all as specified and directed. |
| 37 | S&F modular switch , one way 6 Amps one module complete all as specified and directed. |
| 38 | S&Fmodular switch, one way 16 Amps one module complete all as specified and directed. |
| 39 | S&Fmodular socket 6 A, 2/3 pin combined two module complete all as specified and directed. |
| 40 | S&Fmodular socket 16 A, 3/5 pin combined two module complete all as specified and directed. |
| 41 | S&Fin replacement modular fan regulator step type 120Wtwo modulecomplete all as specified and directed. |
| 42 | S&F in replacement white cover plate with frame three module complete all as specified and directed. |
| 43 | S&F in replacementwhite cover plate with frame four module complete all as specified and directed. |
| 44 | S&F in replacement white cover plate with frame six module complete all as specified and directed. |
| 45 | S&F in replacement white cover plate with frame eight module complete all as specified and directed. |
| 46 | M&L for sub main wiring with two runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 06 Sqmm and drawing through in concelead rigid non metallic PVC conduit pipe medium grade heavy duty in suitable size with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 06 Sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiringwith accessories complete all as specified and directed.Note : (i) Two run of 06 sqmmwith one run 6 sqmmof earth with one run PVC conduit pipe shall be measured agaist one unit. (ii)Cost of cutting /chasing/ plastering /colouring etc as site shall be included matching to disturbed surface as perexisting. |
| 47 | All as per item No 38.00 above but two run of single Core 4 Sqmm for phase, neutral and 4 Sqmm earth wire with suitable size concealed PVC conduit pipe complete all as specified and directed. |
| 48 | All as per item No 38.00 above but two run of single Core 10 Sqmm for phase, neutral and 10 Sqmm earth wire with suitable size concealed PVC conduit pipe complete all as specified and directed. |
| 49 | M&L for sub main wiring with two runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 06 Sqmm and drawing through in open PVC conduit pipe in suitable size with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 06 Sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring including taking out to old unserviceable sub main wiring with accessories complete all as specified and as directed. Note : (i) Two run of 06 sqmmwith one run of 6 sqmm earth with one run PVC casing shall be measured agaist one unit. |
| 50 | All as per item No 39.00 above but two run of singleCore 4 Sqmm for phase ,neutral and one run of 4 sqmm earth wire with suitable sizeopen PVC conduit pipe complete all as specified and directed. |
| 51 | All as per item No 39.00 above but two run of single Core 10 Sqmm for phase, neutral and one run of 10 sqmm earth wire with suitable sizeopen PVC conduit pipe complete all as specified and directed. |
| 52 | Supply only PVC insulation tap in 25 mm width 25 Mtrs long suitable for upto 1.1 KV ISI marked complete all as specified and directed. |
| 53 | S&F in replacement LED Bulb 15 wincluding taking out to unserviceable oldcomplete all as specified and directed. |
| 54 | S&F in replacement Flame proof exhaust fan 305 MM sweep steel body heavy duty with louver mounting bracket ISI marked ,energy saving less noise capacitor type incl making hole in brick wallplastering colour coading and all site requiredwork for disturbed surfacematching with existing and making electric connection using three core copper cable drawn through in steel conduit pipe complete all as specified and directed. Note:Old fan shall be deposited by contractor in MES E/M store Yard and necessary receipt voucher duly signed by Engr-in-Charge and JE. |
| 55 | S&F in replacement Flame proof wall mounting fan 24 inch sweep steel body heavy duty with energy saving less noise capacitor type incl making electric connection using three core copper cable drawn through in steel conduit pipe complete all as specified and directed.Note :Old fan shall be deposited by contractor in MES E/M store Yard and necessary receipt voucher duly signed by Engr-in-Charge and JE. |
| 56 | S&F flame proof sheet metal enclosure for MCBdistribution board, 4 way with incoming MCB 2 pole 25Amps220 volt thermal megnatic base operated as incomer - 01 No outgoing 20 AmpsMCB SP 10A -02 Nos with complete internal bus bar and wiring upto terminals complete all as specified and directed.Note: Quoted rate shall be included cost of MCB and fixing complete all as specified and directed. |
| 57 | S&F flame proofsheet metal enclosure for MCB distribution board SPN of size 330X350X190, 6 way with incoming MCB 2P, 32Amp outgoing MCB1P -10Amp-06Noswith complete internal busbar & wiring up to terminals complete all as specified and directed.Note: Quoted rate shall be included cost of MCB and fixing complete all as specified and directed. |
| 58 | S&F in replacementFlame proof4 way Junction box of size 220x220x120mm all dia cast (LM 6) CMRI certified recommended for gas / vapour group of 11 A and 11 B,zone 1 and 2 and IP 65 protection complete all as specified and directed. |
| 59 | S&F temper proof energy meter in basic current rating 5 to 30 Ampsand maxium400 % , 220 volts single phase two wireconforming to STC with making all electric connection and mounting on teak wood board in suitable sizecomplete all as specified and directed. Note:Old meter shall be deposited by contractor in MES E/M store Yard necessary receipt voucher duly signed by Engr-in-Charge and JE. |
| 60 | S&F temper proof energy meter in basic current rating 10to 60 Ampsand maxium400 % , 220 volts Three phase two wire conforming to STC with making all electric connection and mounting on teak wood board in suitable sizecomplete all as specified and directed.Note: Old meter shall be deposited by contractor in MES E/M store Yard necessary receipt voucher duly signed by Engr-in-Charge and JE. . |
| 61 | S&F smart single phase two wire dual source prepaid energy meters BIS 15884 marked in existing meter board / floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition complete all as specified and directed. |
| 62 | S&F in replacement 35 W building security light LED fitting warm/day cool as required, IP 65 IK 07Aluminium Pressure Die Casting protection with high powerLED completewith including provision of flexible three core cablefrom ceiling rose to fitting terminal for making electrical connection, fixing the fitting on wall including all necessary fixing accessories with nuts, boltand all Earth work complete complete all as specified and as directed . |
| 63 | Supply in replacement to Driver cercuit plate of LED security light fitting capacity 45 to 60 Watt in origional suitable for Make/ model suggested by Dept complete all as specified and as directed . |
| 64 | Supply in replacement to Driver cercuit plate of LED security light fitting capacity 60 to 120 Watt in origional suitable for Make/ model suggested by Dept complete all as specified and as directed . |
| 65 | S&F LED Tube light fitting 20 watt 4 feet with PC batten, compact appearance suitable for Retrofit LED Tube 20 watt including LED tube rod 20 watt self ballasted retrofit lamps with thermoplastic body 270 degree wide distribution CCT 6500 K including fitting fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of size 23/0.0076 including taking down old unserviceable tube light fitting and making necessary connection complete all as specified and as directed . |
| 66 | S&F in replacementLED tube light fitting with frame, driver etc in 10 W2 feet long white colour mounting on tow Nos of PVC round/ squire block on surface of wall / beam etc incl making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings including taking out to unserviceable old fittings complete all as specified and as directed . |
| 67 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth leadusing galvanised earth lead wire 4.0mm dia means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified & directed. |
| 68 | Contd item No 56 (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.(ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order.(iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order.(iv)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. |
| 69 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth leadusing galvanised earth lead strip 25×4mm means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified & directed. |
| 70 | Contd item No 56(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.(ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order.(iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order.(iv)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. |
| 71 | S&F in repacement of white cover plate with frame 2Module complete al as specified & directed |
| 72 | S&F inreplacement blanking plate 1 module |
| 73 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri |