Tender For Repair/Maintenance Of Dg Set, Solar Water Heater, Chlorine Plants, Lifts And Stps Under Ge (I) Kanpur.; 1 Servicing / maint of solar water heater system of capacity up to 750 ltr including dismantling the required parts after that de-scaling, cleaning of water tank, cleaning of pipe, air vent, eliminator etc and refixing the dismantled parts at its original position to make solar water heater functional by replacement of minor accessories and testing on completion complete all as specified and directed. Notes:- (i) Minor spares i.e nut, bolt, washers, wire or other minor parts if required shall deems to be included in this job. (ii) Any accessories found unserviceable that shall be replaced & paid under respective items of this Sch as supply only and cost of fixing of the same shall be deemed to included in this item. 2 Supply only PVC hose pipe for Solar water heating system including clamps, washers, bolts etc where ever reqd complete all as specified and directed. 3 Supply only of thermostat with connected fittings complete all as specified and directed. 4 Supply only of air vent valve complete all as specified and directed. 5 Supply only of drain valve complete all as specified and directed. 6 Supply only of shutt off valve complete all as specified and directed. 7 S&F 20 mm bore GI pipe medium grade ISI marked with all fittings and fixed to walls / roofs or laid in floors / plinth protection including making good disturbed surfaces with cement mortar (1:3) to match with existing surfaces complete all as specified and directed. 8 M&L High density polyethylene (HDPE) pipes of pressure rating 6 kgf/sqcm / Polypropylene Random Copolymer (PP-R) pipes with all fitting / fixture (for hot and cold water supply) fixure to wall / floor of 20 mm dia pipe complete all as specified and directed. 9 S&F 20 mm dia stop valve chromium plated cast copper alloy, fancy type high pressure with capstan head screwed both ends for iron / PP-R pipe or for union complete all as specified and directed. 10 S&F Solar Flat Plate Collector OF Selective Black chrome with Nickel Undercoat absorber, Italian design, (screw less construction for durability) Copper riser tube dia 12.5mm x 0.55mm thick, 9 risers, Copper header tube dia 25.4 mm x 0.72mm thk x 1120 mm length, Toughened glass 4mm thick transmittance up to 87%, Aluminum-PU coated frame, Box Type Structure body, Glass wool and Rock wool insulation, Back Insulation - 50mm thick, Side Insulation - 25mm thick, 48 Kg/Mtr cube insulation density, Stainless Steel - SS 304L, having 6 bar pressure complete all as specified and directed. 11 S&F in replacement of SS-304 pressurized tank 300 ltr and puff insulation 4 kg/sqcm working pressure with MS Stand complete all as specified and directed. 12 S&F in replacement of SS-304 pressurized tank 500 ltr and puff insulation 4 kg/sqcm working pressure with MS Stand complete all as specified and directed. 13 S&F in replacement of SS-304 pressurized tank 750 ltr and puff insulation 4 kg/sqcm working pressure with MS Stand complete all as specified and directed. 14 S&F in replacement of ETC tube size 58mm x 1800 mm solar water collector complete all as specified and directed. 15 S&F in replacement of ETC tube size 58mm x 2100 mm solar water collector complete all as specified and directed. 16 S&F in replacement of ETC Coupler flange set complete all as specified and directed. 17 S&F rotational moulded polyethylene water storage tanks, 250 capacity (cylindrical veryical with closed top) hoisted and fixed in position all as specified in SSR Part I, including MS stand of suitable size as per recommendations of solar water heater, including two coats of anticorrosive paint over and including a coat of anticorrosive primer complete all as specified and directed. 18 S&F in replacement of Mild steel framed/sheet work for tanks/panel/pump cage supported structure/ladder and similar works conforming to Fe-290 Gde-E-165 including welding/cutting of steel including painting of two coats of synthetic enamel paint over and including one coat of primer paint (incl preparation of surface) complete all as specified and directed. 19 S&F in replacement of change over switch on load 415 volt in sheet metal enclouser 4 pole of capacity 125 Amps incl disconnecting and dismantling old and fixing on wall making electric connection with existing cable complete all as specified and directed. 20 M&L for hot lagging and wrapping on GI / PP-R pipe used in internal plumping work all around with bonded mineral wool performed snap on pipe section of density 48 Kg / cum conforming to IS 9842 and covered with required size of glass wool and aluminium cladding of required size for up to 20 mm bore pipe complete all as specified and directed. 21 S&F heating element 1500/2000 watt capacity suitable for solar water heaterpush / screw type with O ring including making electrical connection complete all as specified and directed. 22 M&L for fixing glass wool insulation for Hot water pipe complete all as specified and directed. 23 S&F in replacement of air eliminator complete all as specified and directed. 24 Taking / liftingout defective submersible type raw sewagepumps set of capacity 1.1 KW/2760 RPM from raw sewage sump with column pipe steel rope, submersible cable and accessories, including cleaning, greasing , oiling of bearing of electric motor, impeller shaft and relowering the same after repairing works including replacement of worn out parts as per requirement and testing complete all as specified and directed. 25 M&L for rewinding of submersible type sewage motor 1.1 KW/2760 RPM with existing same type & gauge of winding wire as per motor capacity using new insulation material such as insulating paper sleeves etc.including cleaning and replacement of defective parts complete all as specified and directed. 26 Taking out defective Air blower with motor of capacity 3 KW/1400 RPM with all accessories, including cleaning, greasing,oiling of bearing of electric motor and refixing, including cleaning, greasing, oiling of bearing of electric motor, impeller shaft and commissioning the same after repairing works including replacement of bearing and testing complete all as specified and directed. 27 M&L for rewinding of Air blower motor of capacity 3 KW/1400 RPM with existing same type & gauge of winding wire as per motor capacity using new insulation material such as insulating paper sleeves etc.including cleaning and replacement of defective parts complete all as specified and directed. 28 Supply and replacement of air filter for air blower of capacity 3 KW as per existing pattern/make complete all as specified and directed. 29 Taking out defective Monoblock centrifugal pump set of capacity 5.5 KW/1500 RPM with all accessories including cleaning, greasing , oiling of bearing of electric motor and refixing the same after repairing works including replacement of worn out parts as per requirement and testing complete all as specified and directed. 30 Supply and fixing of Contactor Model No MNX-12 making proper connection with suitble lugs complete all as specified and directed. 31 S&F MCB SPN240 volts 40 Amp including connection with suitable size aluminium / copper lugs complete all as specified and directed. 32 M&L for earthing with GIplate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable and making test point and all connections complete all as specified and directed. 33 M&L for cleaning raw sewage chamber and cleaning all foreign Materials complete all as specified and directed. 34 M&L for draining out sewage water from Fludized Aerobic Bed (FAB) reactor and cleaning and washing the same and inlet /outlet pipes complete all as specified and directed. 35 M&L for drain out sewage water from Tube settler tank and cleaning and washing the same and inlet /outlet pipes complete all as specified and directed. 36 M&L for drain out sewage water from treated watertank and cleaning and washing the same and inlet /outlet pipes complete all as specified and directed. 37 M&L for cleaning of bushes shrubs, grass around out side of STP upto 2 meter between fencing & road complete all as specified and directed. Note : Necessary tools for cleaning will be arranged by the contractor with out any extra cost. 38 M&L for plastic filter media for enhancedbacterial development in filter tank used in STP plant complete all as specified and directed. 39 Removing of dried sludge from sludge drying bed and depositing the same at a distance of not less than 200 mtr from plant complete all as specified and directed. 40 Supply and replacement of butter fly valve of size 50 mm bore ISI marked heavy duty including suitable nut,bolt & washer complete all as specified and directed. 41 Supply and filling of oil ENKLO 320 or equivalentfor air blower of capacity 3 KW complete all as specified and directed. 42 Supply& Pouring sodium hypo chloride ( Chloine percentage 10-11%) in treated sewage water in manufacturer standard packing complete all as specified and directed. 43 M&L for testing of treated water of STP (Monthly) from any NABL approved laboratory and submit the report timely complete all as specified and directed. 44 M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework and all the articles shall be painted with synthetic enamel paint over and including a coat of red oxide complete all as specified and directed. 45 M&L for painting of steel and iron surfaces with one coat of synthetic enemelled paint after preparation of old painted surfaces of STP 100 KLD capacity of STP complete all as specified and directed. Note:- Bidder are advised to visit the site before quoting the tender to find out actual qty of painting. 46 Minor repair/cleaning/servicing/maintenance and testing of chlorine granuals based dosing plant comprising of dosing pump, agitator and FRP tank and connected pipe lines etc once in a week complete all as specified and directed:- Note : (a) Testing of chlorine at consumer end with medical authority and maintained chlorine test record once a week on a register and submit report to concern JE E&M/Engr-in-Charge.(b) Servicing of Agitator of by using necessary lubricant, replacement of bush/bearing, alingning the shaft , key etc. deemed to be included in item rate.(c)Any other spares required for replacement shall be supplied and fixed under relevent item of Sch A. (d) If any defect found in plant contractor should rectify the defect with in 24 Hrs, if failed to rectify the decfectthe contractor shall be liable to pay compensation Rs 500/- (Rupees five hundred only) per plant per day. 47 S&F in replacement of Motor 230 volt, 50 Hz, voltage input 230 volt single phase 50 Hz, current consumption 0.4 Ampr power 120 watt, speed 4 pole induction non synchronous 920 RPM Approx under lead motor shaft dia 15mm X Length 50 mm motor is flange mounted 4 no of 7 mm dia hole at PCD 150 mm incl all fixing arrangement complete all as specified and directed. 48 S&F in replacement of shaft with impeller made out of MOC poly propelene rigid dia 32 mm X Length 500 mm impeller type two bladed pitched blade turbine numbar of impeller- I incl all fixing arrangements complete all as specified and directed. 49 S&F in replacement of Dosing tank only capacity 100 Ltrs MOC PE FRP Ltd contaning port hole for pouring chlorination chemical and water them necessary provision for mounting of moter at proper angel provision for mounting dosing pump on lid level gauge complete all as specified and directed. 50 S&F in replacement of Rotor assembly with bearing brackets & tolerance ring complete all as specified and directed. 51 S&F in replacement of Single head feet rate control with shaft complete all as specified and directed. 52 S&F in replacement of Pump head (ferrules 1/4 & duchbill included) complete all as specified and directed. 53 S&F in replacement of Pump tube complete all as specified and directed. 54 S&F in replacement of Injection check valve complete all as specified and directed. 55 S&F in replacement of Weighted suction line strainer 3/8 complete all as specified and directed. 56 S&F in replacement of 3/8 white suction/discharge tubing complete all as specified and directed. 57 S&F in replacement of Check valve duckbill only (PK-5) complete all as specified and directed. 58 S&F in replacement of Gear motor complete 230 volt 50 Hz complete all as specified and directed. 59 S&F in replacement of Coil 250 volt 50 Hz complete all as specified and directed. 60 S&F in replacement of Roller Assembly complete all as specified and directed. 61 S&F in replacement of dosing pump (Model No 96 NGQ 51) high pressure single head geared motor adustable dosing having output upto 40 US GPD and pressure upto 7 kg/cm2 with connecing accessories complete all as specified and directed. 62 Supply & Pouring Calcium based high strenght granular chlorination chemical having 65 % to 70 % active chlorine, whitish, free flowing, decomposes clear in water solution, free of foriegn matter , the chlorination chemical should contain appropriate quantities of dispersants, corossion inhibitors to prevent incrustation scaling in distribution systems, mercury and other heavy meatl conteminents in chlorination chemical must be Below Detectable Limit (BDL) complete all as specified and directed. 63 Repair/servicing to DG set any make/modal 50/62.5/83 KVA water cooled diesel engine by taking out dismantling segregation of all parts and re-assembling after duly repair/ replacement of following new part fixing including all type machine work such as turning reaming etc, washing, cleaning, greasing , wires, replacement of engine oil, gaskets, flexible coupling & all type nuts bolts washers & other minor parts as required at site and testing on completion at site complete all as specified and directed. Note:- Any other accessories found unserviceable that shall be replaced & paid under respective items of this Sch as supply only and cost of fixing for fixing of the same shall be deemded to included in the quotd rate under this item. 64 All as per item No 63.00 above but for DG Set of capacity 15-20 KVA in Cantt area complete all as specified and directed. 65 Supply only Lub oil filter element for 50/62.5/83 KVA DG Set complete all as specified and directed. 66 Supply only Lub oil filter element for 15- 20 KVA DG Set complete all as specified and directed. 67 Supply only Fuel filter element for 50/62.5/83 KVA DG Set complete all as specified and directed. 68 Supply only of Fuel filter element for 15/20 KVA DG Set complete all as specified and directed. 69 Supply only of Dry type air cleaner for 50/62.5/83 KVA DG Set complete all as specified and directed. 70 Supply only of Dry type air cleaner for 15/20 KVA DG Set complete all as specified and directed. 71 Supply only of V-Belt of fan for 20 to 83 KVA DG Set complete all as specified and directed. 72 Supply only of manual type Governor Assy for 50/62.5/83 KVA DG Set complete all as specified and directed. 73 Supply only of manual type Governor Assy for 15/20 KVA DG Set complete all as specified and directed. 74 Supply only of Starting switch of DG set up to cap 50 to 83 KVA complete all as specified and directed. 75 Supply only of Starting switch of DG set up to cap 20 KVA complete all as specified and directed. 76 M&L for replacement of complete wiring (copper multistrand cable) of DG set any capacity as directed at site including thimble screw and sleaves etc complete all as specified and directed. 77 Supply only of Gauge lube oil pressure of DG set cap 20 to 83 KVA complete all as specified and directed. 78 Supply only of Hose pipe for of DG set cap 20 to 62.5 KVA complete all as specified and directed. 79 Supply only of radiator hose pipe of DG set cap 20 to 83 KVA complete all as specified and directed. 80 Supply only of Injector assy of DG set cap 50 to 83 KVA complete all as specified and directed. 81 Supply only of Injector assy of DG set cap 20 KVA complete all as specified and directed. 82 Supply only of Clamp hose radiator of DG set complete all as specified and directed. 83 Supply only of water body of DG set 50/62.5/83 KVA complete all as specified and directed. 84 Supply only of Turbo charging kit assembly of DG set 50 to 83 KVA complete all as specified and directed. 85 Supply only of self starter 12/24 volt for DG set 50 to 83 KVA complete all as specified and directed. 86 Supply only of AVR (Anti Voltage Regulator) for DG Set of capacity 50 to 83 KVA complete all as specified and directed. 87 Supply only of AVR (Anti Voltage Regulator) for DG Set of capacity 20 KVA complete all as specified and directed. 88 Supply only of Rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24 /12 V DC full wave rectifier unit for DG set 50 to 83 KVA as site requirment complete all as specified and directed. 89 S&F in replacement of Rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24 /12 V DC full wave rectifier unit for DG set 20 KVA as site requirment complete all as specified and directed. 90 S&F in Repair/Replacement of Control Panelfactory made indoor type control cubical made out of 1.6mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 62.5 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs 100 A and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc complete all as specified and directed. 91 M&L for Repair of Control Panel (50-62.5 KVA DG set)for replacing of U/S relay,andall internal wiring including lug,thimble switches with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 3/4 pole MCCBs 100 A and Contactors of capacity as recommended by the manufacturer , detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc complete all as specified and directed. 92 Repair of(In line) fuel pump by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts, celebration for DG set of capacity 50 to 83 KVA & testing on completion complete all as specified and directed. 93 Repair of(In line) fuel pump by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts, celebration for DG set of capacity 15 to 20 KVA & testing on completion complete all as specified and directed. 94 Repair to radiator assy Cleaning washing throughly, descaling and M&L for replacement of rubber size paid and MS Nut & Bolts including brazing /repair of cooling tubeswith dismantling and segregation upper and lower chamber (tank) includingand reassembling complete incl nut, bolt, washers, & spring any type for DG set capacity 20 to 83 KVA complete all as specified and directed. 95 Cleaning decarbonishing and spray painting to DG Set canopy outside of capacity 20 KVA to 62.5 KVA including writing SM No, Srl No, Make, capacity & date of installation complete all as specified and directed. 96 Disconnecting, dismantling & repair to Dynamo with segregation of all parts supply and fix in replacement of armature field, coil, carbon brush and bearing etc reassembling complete & testing on completion complete all as specified and directed. 97 Supply and fixing in replacement of maintenance free battery 12 volt 180 AH 25 plate including battery leads and initial charging of battery complete all as specified and directed. 98 M&L for replacement of Coolant for DG set complete all as specified and directed. 99 M&L for replacement of Engine oil 20 W 40 complete all as specified and directed. 100 Supply and fix in replacement engine Hrs run meter digital type suitable to match with existing system of DG set complete all as specified and directed. 101 Supply and fixing in replacement of maintenance free battery 12 volt 150 AH 25 plate including battery leads and initial charging of battery complete all as specified and directed. 102 Disconnecting, dismantling and repair/servicing to self starter 12/24 volt and replacement of field coil, carbon brush, bush or other unserviceable parts parts and refixing and testing after completion complete all as specified and directed. 103 M&L in replacement of microprocessor digital type DG set controller of DG set capcity 50 KVA to 62.5 KVA (Make of DG set- Greaves Cotton) including connect all control wiring& programming all the parameter related to DG set at site complete all as specified and directed. 104 M&L in replacement of microprocessor digital type DG set controller of DG set capcity 15 to 20 KVA(Make of DG set- Greaves Cotton) including connect all control wiring& programming all the parameter related to DG set at site complete all as specified and directed. 105 S&F in replacement of Automaticbattery chargerAC input 230 + 10% V output DC for 12/24 volt battery current 10-15 Amp for 01 No battery at a time with digital ammeter and voltmeter complete all as specified and directed. 106 S&Fin replacement ofBattery terminal of Copper bolt type suitable for any tpe of battery complete all as specified and directed. 107 S&Fin replacement ofBattery lead of copper conductor 35 Sqmm single core fitted with suitable terminal on both side complete all as specified and directed. 108 M&L for winding of armature winding and field windingwith super enamelled copper wire of appropriate gauge incl varnishing of insulating material and heating up, testing etc for alternator ofDG set of capacity 50 to 83 KVA incl taking out the old burnt windings complete all as specified and directed. 109 M&L for winding of armature winding and field windingwith super enamelled copper wire of appropriate gauge incl varnishing of insulating material and heating up, testing etc for alternator ofDG set of capacity 15-20 KVA incl taking out the old burnt windings complete all as specified and directed. 110 M&L in replacement of flame proof asbestos rope of specified dia wrapped around the exhaust pipe complete all as specified and directed. 111 Supply poring of distilled water for maint of battries complete all as specified and directed. 112 S&F in repair MCCB 4 Pole, 415 V, Adjustable type 160 amps with breaking capacity 25 KA complete all as specified & directed. 113 S&F in repair MCCB 4 Pole, 415 V, Adjustable type 250 amps with breaking capacity 25 KA complete all as specified & directed. 114 Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps complete all as specified and directed. 115 M&L for PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3 core complete all as specified and directed. 116 Repair/servicing to Retrofit Emmision Controll Device any make/modal 62.5 KVA DG Set taking out dismantling segregation of all parts and re-assembling after duly repair work such as structure, Sensor, Automation, operational & panel checks, Pneumatic Cleaning of filters & all type nuts bolts washers & other minor parts as required at site and testing on completion at site complete all as specified and directed. Note:-1) This servicing is carried out by authorised OEM Chakr innovation Private Limited. 2) NABL (National Accreditation Board of Testing and Calibration Laboratories) Testing. 117 Comprehensive maintenance of following lifts in Adm buildings COD Kanpur including checking, repairing, replacing the defective items if any, preventive maintenance, greasing, lubracating, providing necessary item reqd for up keeping the lift in working condition as per OEM recommandation complete all as specified and directed. (a) Passanger Lift (8 Passenger) Machine No- J009009 Installed at Adm block, COD KanpurMake- OTIS elevator Co (I) Ltd. (b)Passanger Lift (13 Passenger) Machine No- J009254 Installed at Adm block, COD KanpurMake- OTIS elevator Co (I) Ltd. NOTE- (i) All repair / Maint to be carried out by OEM /authorised rep of OEM. Minimum two visit in one months with OEM Rep if emergency any time called for repair. Bidder shall enter an MoU with OEM of lift for repair/services of this item. The MoU with OEM shall be submitted immediately after issue of work order/commencement of work. Non submission of MoU with OEM shall lead to cancellation of contract. (ii) Repair/maint of the lift will carried out by skilled/trained personnel under the OEM supervision. (iii) Examine peroidically all safety devices and governors of the lifts and make all customary safety tests. (iv) The necessary T&P reqd shall be arranged by the OEM/Contractor and cost of the same shall deemed to be included in the rate quoted items will be paid and measured separetly as supply only. 118 Supply only J relay OTIS Make complete all as specified & directed. 119 Supply only attached panel for OTIS Make complete all as specified & directed. 120 Supply only Transformer for OTIS Make complete all as specified & directed. 121 Supply only Choke for OTIS Make complete all as specified & directed. 122 Supply only Shaft for OTIS Make complete all as specified & directed. 123 Supply only Shaft Bearing for OTIS Make complete all as specified & directed. 124 Supply only Door Motor for OTIS Make complete all as specified & directed. 125 Supply only Gate Roller for OTIS Make complete all as specified & directed.