| 1 | S&Fin repair galvanised. 2 strand, steel barbed wire 2.24mm diabarbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mildsteel wire, staples or steelpins, etc. complete all as specified and directed.Note :-Each line wire to be measured |
| 2 | Dismantling galvanisedsteel barbed wire fencing any type complete all as specified and directed. Note :-Each line wire to be measured. |
| 3 | Dismantling chain link fencing any type complete all as specified and directed. |
| 4 | Supply & Fixing 75mmx75mmmesh size and3.4 mm dia of wire chain link MS galvanised fencing complete including line wires, rails, straining bolts etc, including provision of binding wire complete all as specified and directed. |
| 5 | Dismantling stone slab floor, hearth or wall tilling including cement mortar bedding (but not backing), and rubbish offpremises etccomplete all as specified and directed. |
| 6 | M&L 20-22mm thick of size not less than 55cm x55cm machine cut, pripolished , Kota stone slab in floors over 20mm thick screed bed in mix 1:6 laid and jointed with grey cement to match the shade of slab including rubbing and polishing of surfaces of any description complete all as specified and directed by the Engineer-in-Charge. |
| 7 | M&L 20-22mm thick (of size not less than 55cm x55cm) machine cut, pripolished , Kota stone slab in skertingover 10mm thick backing coat in mix 1:3 laid and jointed with grey cement to match the shade of slab including rubbing and polishing on surfaces of any description complete all as specified and directed by the Engineer-in-Charge. |
| 8 | M & L forsaw dust and sand in 1:2 ratio for filling, spreading and levelling in layers not exc. 300 mm thick and well ramming including watering as required, complete all as specified and directed. |
| 9 | M & L for rendering 15 mm thick on fair face of brick walls or concrete surface in CM 1:4 finishing the surfacre even and smoothcomplete all as specified & directed. |
| 10 | M & L for preparation of new surface and applying two coat of cement base paint over a coat of primer complete all as specified and directed. |
| 11 | Taking down cement plaster or cement lime plaster, any description from wall including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 12 | M & L rendering 15mm thick cement plaster 1:6 on other than fair faces of brickwork or concrete surface and finishing even and smooth without using extra cement all as specified and directed. |
| 13 | M & L for preparation of new surfacesand applying two coats ofoil bound distemper over a coat of primer complete all as specified and directed. |
| 14 | M & L for preparation of walls and applying one coat of 100% premium acrylic emulsion paint having VOC less than 25gm/ltr and UV resistance as per IS 15489:2004, alkali & fungal reistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon aditives at 1.43 ltr/20sqm all asspecified and directed by Engineer-in-Charge. |
| 15 | M & L for preparation of walls and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489:2004, alkali & fungal reistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon aditives at 1.43 ltr/10sqm over and including priming coat of exterior primer applied at 0.90ltr/10sqm all asspecified and directed by Engineer-in-Charge. |
| 16 | M & L for preparation of old surface and applying one coat of cement base paint complete all as specified & directed by Engineer-in-Charge. |
| 17 | M & L for preparation of old painted surfaces and applying one coat of Oil bound Distemper on walls complete all as specified & directed by Engineer-in-Charge. |
| 18 | M & L for preparation of old plastered surface of walls including cornices and apply two coat of white wash complete all as specified & directed by Engineer-in-Charge. |
| 19 | Dismantling of paver blocks of any desciption and any thickness in floors, laid dry complete all as specifed and directed. |
| 20 | M & L for rubber moulded precastconcrete interlocking paver block any shape and size with gray cement and pigment glossy finish confirming to IS 15658-2006 of 60 mm thickness M-40 Grade complete all as specified and directed. |
| 21 | M&L for sand filling under floors as in cusioning and like including watering and consolidation complete all as specified and directed. |
| 22 | Demolition of un-reinforced Cement Concrete in ground floors and pavings n. exc. 15 cm thickness ( below or above GL) complete all as specified and directed. |
| 23 | M & L for 40 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor finished even and smooth with using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 24 | M&L for PCC1:2:4 type B-0 using 12.5mm graded stone aggregate , as in copping/hold fast etc complete all as specified and directed by Engr-in-charge. |
| 25 | M&L for Plain Cement Cconcrete 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base/as in foundation to floor etc complete all as specified and directed by Engr-in-charge. |
| 26 | M&L providing Chequered cement concrete tiles 25cm x 25cm x22mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigmentlaid over and includingscreed bed or bedding layer 20 mm thick in cm 1:6 as in floors complete all as specified and directed. |
| 27 | Demolition ofBrick works masonry, built in cement mortar or cement limemortar including all quoins, arches, pillars etc but excludingashlar facing, dressed stone work andpre-cast concrete articles completeall as specified and directed. |
| 28 | M & L for brick workwith subclass “B” Old size bricks, straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specified and directed. |
| 29 | M & L for rendering 15 mm thick on fair face of brick walls or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified & directed. |
| 30 | Dismantling wrought iron or mild steel work of any description (i.e wind tie etc) not otherwise provided for etc complete all as specified and directed. |
| 31 | S & F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 32 | S & F Rolled Mild Steel Framed work as in doors or Gates, fencing post, support on wall of angle or other section confirming to Fe 410 -W (Gde-, E- 250) A quality-with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering and hanging and fixing complete all as specified and directed. |
| 33 | M&L in applying two coats of synthetic enamel paints over a coat of red oxideprimer on new steel surfaces over 10 cm width or girth including preparatinon of surfaces complete all as specified and directed by the Engineer-in-Charge. |
| 34 | M & L for preparation of old steel surface exceeding 10 Cm width or girth and apply two coat of synthetic enamel paint complete all as specified & directed. |
| 35 | Demolation of cement concrete (reinforced ) of any description and in any position complete all as specified & directed. |
| 36 | M&L mild steel deformed TMT bar 10mm dia and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by the Engineer-in-Charge. |
| 37 | M&L PCC (1:2:4) type B-1 nominal mix using 20 mm agregate as in lintels upto 1.5m clear span, cills, shelves, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all as specified and directed. |
| 38 | M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping ,) finishing the surface fair complete all as specified and directed. |
| 39 | Dismantling of Asbestos Cement(corrugated/semi corrugated) sheet/PGI/CGI in roof covering including ridges all as specified and directed by Eng-in-Charge. |
| 40 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and making good to disturb surface, complete all as specified and directed. |
| 41 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri |