| Sl. No. | Item Description |
| 1 | Uprooting Juli Flora/sarakanda, paharikikar orarrows upto 0.50 m ,depth belowground level.WRD BSR HMH 2023 North Chap No 5 a , item no5b |
| 2 | Felling trees of the girth ( measured at a height of 1 mabovegroundlevel)includingcuttingoftrunks andbranchesremovingtherootsandstackingof servicable material and disposal of unserviceable material Lead upto 1000 m ,30 Cm. to below 60 Cm. Girth (WR North BSR-2023,Ch-5a,Item 1a). |
| 3 | Felling trees of the girth ( measured at a height of 1 mabovegroundlevel)includingcuttingoftrunks andbranchesremovingtherootsandstackingof servicable material and disposal of unserviceable material Lead upto 1000 m ,60 Cm. to below 120 Cm. Girth(WR North BSR-2023,Ch-5a,Item 1b). |
| 4 | Earth work excavation in ordinary soil for distributaries and minors having discharge less than 10 cumecs: Kassi work undressed .(WR North BSR-2023,Ch-6,Item 2a). |
| 5 | Earthwork excavation for Lip Cutting in ordinary soil for disty. & minors having vertical height above 0.75 m., kassi work including rehandling with dressing of earthwork. (With extra two initial leads) (WR North BSR-2023,Ch-6,item 25b) |
| 6 | Carriage of EW katcha 2.0 KM ,WRD BSR HMH 2023 North Chap No 4 , item no 3. |
| 7 | Dressing of earthwork ,WRD BSR HMH 2023 North Chap No 6 , item no 14 |
| 8 | Extra on earthwork for laying in 15 to 25 cms layers including Dressing & Watering as per specifications (Water to be made available by the department at one place of work site).(WR North BSR-2023,Ch-6,item 9),WRD BSR HMH 2023 North Chap No 6 , item no 9 |
| 9 | Dressing of dowels in addition to payment for dressesd earthwork if top width of dowel is less than 1 mWR North BSR-2023,Ch-6,item 18 |
| 10 | Compaction of earthwork by mechanically operated Vibro-Compactor/ any other mechanical means to attain a density 95% of Maximum Dry Density.As perWRD N BSR 2023 Chapno 6Item no10 |
| 11 | Provdiding and laying M-15 gradesingle PCC block (30x15x5 cms) liningconsisting of (i) 12 mm thick plaster in CM (1:6) on sub grade (ii) 16 mm thick sandwich plaster in CM (1:3) over the plaster at item no. (i) above (iii) 50 mm thick PCC blocks (30x15x5cm) in CM (1:3) with 6 mm thick CM layer including curring upto completion of lining section.(A)In Bed including dressing of bed, Pummping charges of water to lining heading from sourceand curing upto 28 days.[Ref: Water Resources (North) BSR, Chapter 7, Item: 27A] |
| 12 | Providing & layingM15 grade Single PCC block (30x15x5cm ) liningconsisitingof :- (i) 12 mm thick plasterin CM (1:6) on subgrade (ii) 16mm thicksandwichplaster in CM (1:3) overthe plaster at item no (i) above (iii) 50 mm thickBlocks in CM (1:3) with 6 mm thickCM layer includingcuringupto completion of lining section as per design & Specification.(b)On Side Slope including dressing of sides, scafolding & template allowance, Pummping chargesof waterto lining heading from source and curing upto 28 days.,WRD BSR HMH 2021 North Chap No 7 , item no28b |
| 13 | Plastering with cement mortar (1:3) 15 mm thick on brick work in parapet as per MoRTH specifications Clauses 1312.4 (As per PWD HMH Road BSR 2022, Chapter -13, Item 13.19) |
| 14 | Earthwork in foundations trenches, lift upto1.5 m stacking the excavated soil clearfrom the edge ofexcavation and then returning the the exacavted soil in 15 cm ,layers when requriedintosides of foundations etc , consolidatingeach cdeposited layer by rammingand wateringand then disposingof all surplussoil asdirected within a leadof 30m ( for DowelEarthwork) , aIn ordinarysoil likessandyloam,softclayetc,WRD BSR HMH 2023 North Chap No 6 , item no21 |
| 15 | Providing and laying in position cement concrete for canal dowelfoundation including curing , compaction andcost of centeringand shuttering - In ,M 10 grade NominalMix 1:3:6 (1 cement : 3 coarsesand: 6graded stone aggregate 20mm nominal size ) WRD BSR 2023 NorthHMH Chap 7 item no7 |
| 16 | Providing and laying in position cement concrete for Canal Dowel including curing, compaction and cost of centering and shuttering in grade M15, 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). (WRD North BSR 2023 Ch.No. 7itemno7a) |
| 17 | Dismantling of lining & Disposingof thematerial with in 1/2 km lead , SingleTileLining WRD BSR HMH 2023 North Chap No 7 , item no26a |
| 18 | Dismantling of existing structures like culverts, bridges, retaining wall sand other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding where vernecessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per MoRTH Specification Clause 202.By Mechanical Means Reinforced Cement Concrete (As per PWD Road BSR 2022, Chapter R-2, Item 2.5.2.2) |
| 19 | Brick masonry work in cement mortar 1:3, with mechanical mixer in foundation (at any level) complete, including all scaffolding etc. but excluding pointing and plastering as per drawing and technical specification as per MoRTH Specification : Section 1000,1300 (PWD Road BSR-2025Chap. No. B-2, Item no 2.1) |
| 20 | Earthwork in excavation for foundation of structure complete with all lift,dewatering,shoring and shuttering etc. including refilling of trenches in 250mm layers,ramming,watering and disposal of surplus earth with all lifts and lead upto 1000 meters exclusive of compensation of earth as per MoRTH specification Clause 301 to 305. depth upto 3 metre in ordinary soil(PWD Road BSR-2025 Chap. No. B-1, Item no 1.1.1) |
| 21 | Providing and laying Cement concrete for plain/reinforced concrete inopen foundationas per drawing and technical specification as per MoRTH Specification :Section1500, 1700&2100 including form work at any level.P.C.C. grade M15(PWD Road BSR-2025 Chap. No. B-2, Item no 2.3.1) |
| 22 | Supply and fixing in position of APM blocks made of CI as per standard specification with adjustable arrangement and required fixtures including transportation tositesecondstage concretingin (CC1:2:4)centering,shuttering,painting withred oxidefinishingetccompleteinallrespectcostof APM Block (all size) per block.(W.R.North BSR 2023,Ch-11 Item 6) |
| 23 | Providing and laying steel reinforcement at any level includingin foundation as per drawing and technical specification as per MoRTH Specification : Section: 1600:TMT Steel reinforcement (As per PWD HMHRoad BSR 2025, Chapter B-2, Item 4.3.1.3) |
| 24 | Structural Cement concrete for reinforced concrete in superstructure at any levelcomplete including steel formwork, scaffolding etc. as per drawing and technical specification as per MoRTH Specification 1500 & 1700, M 25 grade solid slab superstructure(As per PWD HMH Road BSR 2025, Chapter B-4, Item 4.1.1) |
| 25 | Construction of embankment with approved material obtained from borrow pits with a lift upto1.5m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables300-1and300-2 with a leadupto50m as per MoRTH Specification Clause 305.3(As per PWD Road BSR 2025, Chapter R-3, Item 3.4) |
| 26 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and MoRTH Specification Clause 801(As per PWD Road BSR 2025, Chapter-10 , Item 10.5) |
| 27 | Printing new letters and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade.as per drawings and MORTH specification clause 801 English and Roman (As per PWDRoad BSR 2025, Chapter -10, Item 10.1.2) |
| 28 | Providing and fixing 20mm thick compressible fibre board in expansion joint complete. (As per PWD Road BSR 2025 Chapter B-3, Item 3.14.2.2) |
| 29 | Providing and laying Expansion Joint complete as per drawing and technical specification.With corrugated copper plate, compressible fibre board, pre-moulded joint filter and joint sealing compound as per MoRTH Specfication section 2600 Providing and fixing 20mm thick compressible fibre board in expansion joint complete. (PWD Road BSR-2025 Chap. No. B-3, Item no 3.14.2.2) |
| 30 | Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.50 M including taking out the excavated soil and depositing and refilling of jhiri with watering and ramming and disposal of surplus excavated soil as directed with in a lead of 50 M. All kinds of soil. (As per PWDHMH BSR 2022, Item no 1.8) |
| 31 | Providing and laying in position Cement Concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering. All work up to plinth level. M10 Stone Aggregate 20 mm nominal size ].(As per PWDBuilding BSR 2022 , Item no 3.1.4) |
| 32 | Brick work withcommon brunt clayFPS Non modular bricksof class designation 75 in foundation & plinth cement mortar 1:6 (As per PWD Building BSR2022 HMH, Item no 5.1.2) |
| 33 | Brick work withcommon brunt clayFPS Non modular bricksof class designation 75 in super structure above plinth leveluptofloor 5level in all shapesandsizes in cement mortar 1:6 (As per PWD Building BSR2022 HMH, Item no 5.2.2) |
| 34 | P & L damp proof course with cement concrete grade M-15mortar prepared with 1 % solution of water proof compound including two coats of hot blown bitumen ( 2 Kg. per sqm.) complete as per specification 50 mm thick.PWD Building BSR 2022,Ch B-315 Item no3.7.1 |
| 35 | Centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways withsteel propes andremoval of form work for upto floor five level , for suspended floors, roofs landings staircases, balconies, girders, cantilevers, bands coping bed plates, anchor blocks, sills, chhajjas, lintel, beam etc.(As per PWDBuilding BSR HMH 2022 , Item no 4.10.2 ) Chap NoB-4 |
| 36 | Providing and fabricating reinforcement for R.C.C. work including straightening, cuting, bending, placing in position and binding ( Including cost of binding wire ) all complete up to floor three level. Hot rolled deformed bars( IS 1139 ) .(As per PWDBuildingBSRHMH 2022 , Item no 4.13.3) Chap noB-4 |
| 37 | P & L in position specified grade of reinforced cement concrete including curing compaction finishing with rendenring in cement sand mortar 1:3 ( 1-Cement : 3-Coarse sand ) and making good the joints excluding the cost of centering , shuttering and reinforcement. All work upto plinth level : M20 ( stone aggregate 20mm nominal size). PWDBSR Building 2022 Ch B-4,item 4.1 |
| 38 | P & F 1st quality Vitrifiedtiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade,laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm PWD BSR Building 2022 Ch B-7, item 7.18.2 |
| 39 | Plaster on new surface on walls in cement sand mortar 1 : 4 including raking of joints etc. complete fine finish: 12 mm thick.PWD BSR Building Ch B-12, item 12.2.3 |
| 40 | Providing and laying brick kharanja on roofs with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound in square pattern 75mm to 100mm thick average[Ref: PWD BSR Integrated (Bldg) 2022 , Chapter B-10 Item No:10.18.1] |
| 41 | Providing and fixing M.S. Sheet 1MM single leaf door shutter in angle iron frame 35 x 35 x 5 mm suitabilit diagonally braced with 25 x 3 M flat iron above and below lock rail of size 50 x 5 mm beading extra including all fittings, as per direction of Engineer In-charge but excluding cost of Chowkhats, including two coats of anti-corrastie red oxide primer paint M.S. Sheet 18 SWG (1 mm thick) .(As per PWD BuildingBSR HMH 2022, Item no 9.17) chap no B-9 |
| 42 | P&F steel glazed doors, windows and ventilators shutters of standard rolled steel section (IS 1038-1983) joint mitred and welded with steel 13×3 mm lugs 10 cm. long embedded in cement concrete blocks 15×10×10 cm of 1:3:6 ( 1- Cement : 3- coarse sand : 6 - graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal sash putty of approved make, or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and fittings except neccessary hinges of pivots steel handles and peg stay etc. as required. Windows side hung ventilator topor center hung (openable ). PWD BSR Building HMH 2022,item 9.19.3 |
| 43 | P & F Squre bars or other flat welded to window , ventilators etc.PWD BSR Building 2022 Ch B-9, item 9.27 |
| 44 | P & F G.I. Pipes (Internal work) with G.I. fittings ( IS : 1239 Mark) & M.S. clamps including cutting and making good the walls and floors: 15 mm dia nominal bore.A classPWD BSR Building 2022Ch S-2(2),item 2.1.1 |
| 45 | P. and F. Bib Cock ( I.S.:8931 Mark ) superior quality of approved make :-- Brass 400 gm. 15.00 mm nominal bore(As per PWDBSR Building 2022 , ChapNo-S-2, Item 2.7.1 |
| 46 | P & F Stop cock (IS: 8931 Mark) superior quality & of approved make: Brass 400 gm. 15 mm nominal bore.PWD BSR Building Ch S-2(2), item 2.8.1 |
| 47 | P & F Full way valve (IS:778 Mark) or wheel valve of approved make: Gun-metal 15mm nominal bore. PWDBSR Building 2022 Ch S-2(2),item, 2.15.1 |
| 48 | P & F squatting Pan (Indian type) white glazed vitreous China 1st quality W.C. Pan ( IS: 2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor (excluding the pair of foot rest). Size 510 mm. PWD BSR Building 2022 Ch S-1(2),item 1.1.2 |
| 49 | Vitreous china foot rests 250x130x30 mm[Ref: PWD BSR Integrated (Bldg) 2022 , Chapter basic rate of materials Item No:1363] |
| 50 | P&F Low level Flushing Cistern of 10 ltrs capacity (IS:2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall: PVC with PVC bend as per IS: 7231. PWD BSR Building 2022 Ch S-1(2),item 1.20.2 |
| 51 | P & F rigid PVC pipe (IS: 4985 mark) class 2 (4 Kg./Cm.) approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant.PWD BSR BuildingHMH 2022 Ch S-3(2),item 3.16.3 110 mm dia |
| 52 | P & F rigid PVC pipe (IS: 4985 mark) class 2 (4 Kg./Cm.) approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant.PWD BSR BuildingHMH 2022 Ch S-3(2),item 3.16.2 75 mm dia |
| 53 | P & F rigid PVC pipe fittings (IS: 4985 mark) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant: v Reducer 110mm (3.17.2.ii) |
| 54 | P & F rigid PVC pipe fittings (IS: 4985 mark) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant: PWD BSR Ch S-3, 3.17,, Plain Tee 110 mm(3.17.3.ii) |
| 55 | P & F rigid PVC pipe fittings (IS: 4985 mark) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant: PWD BSR Ch S-3, 3.17,, Bend 110 mm (3.17.9.ii) |
| 56 | P & F rigid PVC pipe fittings (IS: 4985 mark) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant: PWD BSR Ch S-3, 3.17, Socket Plug 110 mm (3.17.13.ii) |
| 57 | P & F rigid PVC pipe fittings (IS: 4985 mark) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant: PWD BSR Ch S-3, 3.17, WC connector bent type(3.17.117.ii) |
| 58 | Construction of soakage well in all types of soil of approved drawing, top 90cm portion in 450mm thick masonary with CM 1:6, 80 mm thick stone slab covering, jointing of slab in CM 1:3, Rathal, Kharanja 40mm thick M-15 grade C.C. flooring, earth work etc. complete including disposal of surplus earth within a lead of 50 mtr. Inner dia 90 cm & 10 to 12 mtr deep. PWD BSR Building 2022 Ch S-3, item 3.24.1 |
| 59 | P & F PVC Storage Tank (IS:12701 marked indicating the BIS licence No.) of approved make with cover ,25 mm dia1 M long G I over flow pipe & 25 cm,long wash out pipe with plug & socket,icluding placing on terrace (at all floors ),making connection etc. complete ofapproved design ,1000 Litre , PWD Road BSRHMH2022 Chap noS-2,Item no2.26.5, |
| 60 | Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal, 6 A switch , 3 pin ceiling rose/ Lamp holder / 3 point Connector, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .As perPWD ELE BSR 2022 Item ch item 01 Short Point (upto 3meter) (E01.1.1) |
| 61 | Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal, 6 A switch , 3 pin ceiling rose/ Lamp holder / 3 point Connector, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .As perPWD ELE BSR 2022 Item ch item 01 Medium Point (upto 6meter) (E01.1.2) |
| 62 | Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal, 6 A switch , 3 pin ceiling rose/ Lamp holder / 3 point Connector, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .As perPWD ELE BSR 2022 Item ch item 01Longpoint (upto 10 meter) (E01.1.3) |
| 63 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating asper VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additionaltechnical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. (E04.1.19) |
| 64 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating asper VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additionaltechnical parameters of products/ work , refer Annexure \"A\" attached with this BSR .2 x 6.0 sq.mm (E04.1.16 ) |
| 65 | Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating includingmaking connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with thisBSR . 40 A rating (E06.1.2.3) |
| 66 | Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating includingmaking connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with thisBSR . 6 A to 32 A rating ( E 06.1.1.2) |
| 67 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, conforming to IS:374-2019, & IS:1885 -P-V1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductormaking connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached withthis BSR .(E15.7.2) 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to< 5 ) |
| 68 | Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tube including sidecovers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR. Suitable for 4\"LED Tube shape fixture 2 X 18/20 W (E17.11.2) |
| 69 | Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As perANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own inhouse NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure \"A\" attacheded with thisrefer Annexure \"A\" attached with this BSR 18/20 Watts (E17.9.5) |
| 70 | Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .1200mm, Min. Lumens output 2000 lm LED Tube rod with Glass Housing (Electric BSR JAIPUR, 2022,Item No. 17.2.3) |
| 71 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete[Ref: PWD BSR Integrated (Bldg) 2022 , Chapter B-12 Item No: 12.23] |
| 72 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.[Ref: PWD BSR Integrated (Bldg) 2022 , Chapter B-12 Item No: 12.40.1] |
| 73 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding.New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ).[Ref: PWD BSR Integrated (Bldg) 2022 , Chapter B-12 Item No: 12.42] |
| 74 | Painting top of roof with bitumen of approved quality at 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10sqm including cleanin the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete; With residual type petroleum bitumen of penetration 80/100[Ref: PWD BSR Integrated (Bldg) 2022 , Chapter B-10 Item No:10.15] |
| 75 | Providing and laying steel reinforcement at any level includingin foundation as per drawing and technical specification as per MoRTH Specification : Section: 1600:TMT Steel reinforcement (As per PWD HMHRoad BSR 2025, Chapter B-2, Item 4.3.1.3) |
| 76 | Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 2905.600 mm dia (PWD Road BSR-2025 Chap. No.R-9, Item no 9.3.4) |
| 77 | Add Extra for earth takenfrom private land,land to be arranged by the contractorthrough private negotitations, item applicableon certification by Ex.En. Thatno earthisavailablewithin canal boundary(i) For Command AreaWRD BSR HMH 2023 North Chap No 10 , item no 2 (ii) . |
| 78 | Rubbing and clearing the surface of existing brick/ tile lining to be used as subgrade both in bed and side slopes by means of wire brushes water/ air applied under pressure through nozzle to get rid of dirt, sand etc. deposited on it, complete in all respect, as per specifications and the instructions of the engineer incharge for preparation of surface.WRD BSR 2023 Ch. 7 item no. 32 |
| 79 | Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.In Cement mortar.(PWD BSR-2025,Ch-14,Item 14.7.3) |
| 80 | SITC of ContactorOEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart andmade out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .For single phase Submersible / Monoblockpump0.5 HP to 1.5 HP (DOL starter)[Ref: Electrical PWD BSR 2022 Ch-21 Iterm 21.13.1.1 ] |
| 81 | Providing MS Nut Bolts of required size and type, as per specifications with testing, including all lead and lifts, packing & forwarding charges for all components etc. complete. (WR Bikaner BSR-2022,Ch-XII ,item 27) |
| 82 | Labour charge for removing existing vertical lift canal gate and lowering of new /existing gate having weight 1 to 3 MT including,greasing ,oiling,cutting of accessoris as per direction of engineer in charge as per specification and drawing of the department excluding the cost of roller ME BSR 2022 IGNPBikaner chap no.2 item no.3 |
| 83 | Removing of old water seal from canal gate,including cutting of existing nut bolt etc.complete in all respect ME BSR 2022 IGNPBikaner chap no.2 item no. 12 |
| 84 | Painting of canal gate with 2 pack zinc chromate/phosphate primer in two coat The dry thickness of each coat should be 35 microns and total thickness should not be less than 70 micron .And painting of 2 pack epoxy paint in treecoat of approved color as per Engineer in charge confirmingto is 104 ME BSR 2022 IGNPBikaner chap no.2(b) item no. 3 |
| 85 | Supply and fixing of under driven worm type gear box single reduction ,right angle twin ouput shaft for vertical lifting arragement of canal gate CI grade 220 compatibal to exiting system ME BSR 2022 IGNPBikaner chap no.2 item no.19 |
| 86 | Supply of water seal flat type for canal gate having size 100x12 mm as per is 11855as per ME BSR 2022 IGNPBikaner chap no.2 item no. 7 |
| 87 | fixing charge of new water seal including punching hole and nut bolt complete in all as per ME BSR 2022 IGNPBikaner chap no.2 item no. 11 |
| 88 | Supply of fiberglass reinforced plastic (frp) gague plat for accurate measurement of water level moulded and sandwiched with MS strip both side finish front side engravedand moulded computerized marking of bands and figures covered in radium eye pleasent colour combinationlaminated with high abrasion grade polyurethene provision of ms pressed channel for gauge plate more than 60 cm width etc.NORTH HMH WRD BSR 2023 CHAP NO.11 ITEM NO.11 ,(a) 10 cm wide |
| 89 | Supply of fiberglass reinforced plastic (frp) gague plat for accurate measurement of water level moulded and sandwiched with MS strip both side finish front side engravedand moulded computerized marking of bands and figures covered in radium eye pleasent colour combinationlaminated with high abrasion grade polyurethene provision of ms pressed channel for gauge plate more than 60 cm width etc.NORTH HMH WRD BSR 2023 CHAP NO.11 ITEM NO.11 ,(b) 15 cm wide |
| 90 | Recovery of Bricks Bats of cliankers at site (350 nos. brick bats @1500 per 100 nos) |