| 1 | Demolition of cement concrete in ground floor and pavings not exc 15cm thickness below or above ground level, including removal of debries to a distance exc 1.5 Km but n. exc 2 Km complete all as specified and as directed. |
| 2 | M & L for Cement concrete 1:4:8 type D2 (40mm graded aggregate)in sub base complete all as specified and as directed. |
| 3 | M & L for 100 mm thick Cement concrete 1:4:8 type D2 (40mm graded aggregate)in sub base of hardstanding/ paver block/ checked tile/ stone slabe complete all as specified and as directed. |
| 4 | M & L for 100 mm thick cement concrete 1:2:4 type B-1 (20 mm graded aggregate) as in floor complete all as specified and as directed. |
| 5 | M & L for Hardcore of gauge n exc. 63 mm, broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with 8 to 10 ton roller compacted complete all as specified and directed by Engr in Charge |
| 6 | Dismentling of stone slabs and tiles laid bedded and pointed in any mortar of any description including removal of sand cushioning under paver block, complete all as specified and directed. |
| 7 | M & L for Machine pressed precast concrete interlocking paver block of approved shapewithout correctin factor for chamfering , made in rubber moulds with 0.5mm thick scratch proof lacquer coating on top surface , with white cement and pigment laid over , confirming to IS 15658-2006 ofsize 60mm thickness, with minimum compressive strength of 35 N/Sqmm (M-35 Grade) complete all as specified and directed. |
| 8 | M & L for Machine pressed precast concrete interlocking paver block of approved shapewithout correctin factor for chamfering , made in rubber moulds with 0.5mm thick scratch proof lacquer coating on top surface , with white cement and pigment laid over , confirming to IS 15658-2006 of size 80mm thickness, with minimum compressive strength of 40 N/Sqmm (M-40 Grade) complete all as specified and directed. |
| 9 | M&L for sand filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed. |
| 10 | Refixing for Machine pressed precast concrete interlocking pave block and shape and size confirming to IS 15658-2006 of 60/ 80 mm thickness M-35 grade including levelling and spreading of sand cusion as laying in floor etc complete all as specified and as directed . |
| 11 | M&L for 25 mm to 30 mm thick factory made cement concrete chequered tiles of square shape in approved color and design(size,color & designas per directed by Engr-in -charge) laid on 15 mm thick cement mortar 1:4 including curing, finishing complete all as specified and directed by Engr-in-charge. |
| 12 | M&L for preparation of exterior floor/ paver/ chequered tile surfaces and applying a coat of glossy finish floor coat exterior emulsion paint of floor to match with existing colour or any other selected colour by using brush/ hand roller etc complete all as specified and as directed by Engr-in-Charge. |
| 13 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed |
| 14 | M&L Cement 1:3:6, type C1, using 20 mm aggregate providing, cement concrete in edges of path, rounded or chamfered on edges etc complete all as specified and directed |
| 15 | M & L for preparation of new or previously untreated plaster/ concrete/Stone surface of any description over 10cm girth or width, not otherwise described & applying applying two coats of synthetic enamel paint over a coat primer,complete all as specified and as directed |
| 16 | M & L for preparation of old painted plaster/ concrete/Stone surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 17 | Demolition of stone slabs of any thickness & in any position laid, bedded and pointed in any mortar otherwise specified complete all as specified and directed. |
| 18 | M&Lfor Graniteslab/ (lakha red) 20 mm thick (table rubbed and polished) as in steps, jambs, pillars, window cills, platform, shelves, cooking platforms and like in cement mortar (1:4) including pointing in coloured cement (1:2) using marble dust with admixture of pigment to match with granite shade, laid over and including 15 mm thick cement screed bed in CM 1:6 complete all as specified and as directed. |
| 19 | Labour only for moulding to granite stone in to bracket straight or circle to facing of squared granite of any description complete all as specified and as directed. |
| 20 | M&L for Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish including rubbing and grinding complete all as specified and as directed. |
| 21 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment including 15 mm thick cement screed bed in CM 1:6 complete to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 22 | M& L for glass mosaic tiles of approved shade having thickness 2 to 4 mm laid on floor or vertical surface. The tiles shall be fixed with suitable adhesive over prepared surface and joint filled with waterproof epoxy grout including demolition of existing tiles complete all as specified and directed by Engr-in-charge. |
| 23 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 24 | S&F for Roof trusses (framed), trussed,purlins, rafter,crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, Fe 410-W (Gde-E-250) quality-A,etc complete all as specified and as directed. |
| 25 | S & F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment, Fe 410-W (Gde-E-250) quality-A complete all as specified and as directed. |
| 26 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5cm and not exceeding 10cm long and dia of neck 11 to 15mm, complete all as specified and as directed. |
| 27 | M&L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 grade-165 complete all as specified and as directed.. |
| 28 | Dismantling post or struts of steel or RCC of any section, including taking out embedded portion in concrete and making good the disturbed ground complete all as specified and as directed. |
| 29 | S&F for mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, flat iron fillets (for securing wire mesh etc), wind ties etc including all necessary welding, drilling etc and similar works confirming to Fe-290 grade E-165 complete all as specified and as directed. |
| 30 | Dismantling fencing wire mesh any type complete all as specified and as directed. |
| 31 | Supply only chain link MS Galvanised fencing any size are complete all as specified and directed Engr-in Charge. |
| 32 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed. |
| 33 | S&F for GI chain link fencing with PVC coated 50mm x 50mm mesh including fixing of MS flat iron, MS bars & bolts to fencing postscomplete all as specified and as directed. (Note: The supply only of MS flat iron, Rod & MS bolts shall be measured & paid under relevent item of Schedule) |
| 34 | Supply only mild steel flat iron, round bars etc. in available lengthcomplete conforming to Fe-290 (Gde E-165) complete all as specified and directed. |
| 35 | S&F in repairs GI concertina coil ofany size and dia (dia of coil when unstretched) and fixed on angle iron post/struts complete all as specified and directed. Note : Size and dia of coil and wire will be as per directed by Engr-in-charge. |
| 36 | S&F in repair Galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2 mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bollts incl securing or tying at crossing with and provision of heavy duty galvanised mild steel wire, staples or staple pins etc complete all as specified and as directed. (Note : Each line wire to be measured.) |
| 37 | M&L for Preparing new steel surfaces over 10 cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 38 | M&L for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width and grith and applying one coat of synthetic enamel paint completeall as specified and as directed |
| 39 | Dismantling Plain or corrugated steel/ Fibre translucent sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 40 | S&F Fibre glass reinforced translucentsheeting 2mm thick fixed withtwo corrugations side lapand washer in roof, wall etc.fixed with coach screw and washer in roof, wall etc complete all as specified and as directed. |
| 41 | M&L for Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed by Engr in Charge. |
| 42 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge , fixed with self tapping screws as specified etc complete all as specified and as directed. |
| 43 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar complete all as specified and as directed. |
| 44 | M&L for Brickwork with fly ash bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 45 | Taking down cement plaster in cement or cement lime mortar on brick or stone walls/ concrete wall etc. including raking out joints, hacking for key, scrubbing down with water etc, including removal of debries to a distance exc 1.5 Km but n. exc 2 Km. complete all as specified and as directed. |
| 46 | M&L for 15 mm thick rendering in cement mortar 1:4 by using manufacture/washed plaster sand on fair faces of brick work or concrete surfaces, including finishing even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 47 | M & L forapplying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 48 | M&L Preparation of old surface of wall shall include complete removal if required, brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm including filling up all cracks and defects with CM 1:3 complete all as specified and as directed. |
| 49 | S&F in repairfor Aluminium Composite Panel of 3mm thick exterior grade in wall/column/ceilling with combination of aluminium skin material of 0.25mm thick (two or more metallic coloured coating sheet as directed) aluminium sheet of alloy grade 1100-H14 cover material, coated on external side with PVDF coating containing 70% resins for anti-fungal and anti bacterial properties and the center core shall be with natural polythelene (HDPE) bonded to the aluminium skin on both side over aluminium frame of section 50 mm x 37 mm x 1.6 mm (16 guage) fixed on the wall/ Ceilling. Cladding panal to be fixed with rawl plug and SS screw all as approved on walls and roof including necessary accessories and joint filled with silicon , complete all as per manufacturer\"s instructions and as directed by Engr-in-charge. Note :Rate for necessary scaffolding will be include in Quated rate. |
| 50 | M&L in repair for polished plain acrylic sheet having thickness of 2mm use in Italian letters of size 450mm long and 60mm thick with LED dotted lights, fixed with SS screw on ACP cladding complete all as specified and directed by Engr-in-Charge. |
| 51 | Demolition of reinforced cement concrete of any description and in any position complete all as specified and as directed. |
| 52 | M & Lfor precast concrete slab/cover, cover slabs (for man holes/ drain etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face using cement concrete1:2:4 type B-1 using 20 mmgraded aggregates set and jointed in CM 1:4 complete all as specified and directed by Engineer-in charge. |
| 53 | M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, TMT bars,etc complete all as specified and as directed. |
| 54 | M&L for cement concrete Type B0 1:2:4 (12.5mm graded agregate) in coping supported on wall, complete all as specified and as directed. |
| 55 | M&L for Cement concrete type C2 1:3:6in surface channels and drains complete all as specified and as directed. |
| 56 | M&L for precast cement concrete type C0 1:3:6 (12.5 mm graded aggregate) louvres and jallies, 35mm thick including all mouldings set in cement mortar 1:4 including demolition of existing complete all as specified and directed. Note : Cost of frame and formwork will be include in quated rate and coping above Jallies will be paid under seperate item. |
| 57 | M&L for Stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick ; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush including removing of exixting crushed stone complete all as specified and directed by Engr in charge. |