Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #51955905

Tender For Comprehensive Maintenance Of Swimming Pools, Filtration Plant, Dg Sets, Solar Water Heaters And Other Misc Item Under Ge (South) Bangalore.

Issued by Statutory Bodies & Commissions/Committees · bangalore, Karnataka
Tender Value
45 Lakhs
Estimated cost
Bid Submission
22 Nov 2025
0 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bangalore → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Comprehensive Maintenance Of Swimming Pools, Filtration Plant, Dg Sets, Solar Water Heaters And Other Misc Item Under Ge (South) Bangalore.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Nov-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-Nov-2025

BOQ

Name of Work: COMPREHENSIVE MAINTENANCE OF SWIMMING POOLS, FILTRATION PLANT, DG SETS, SOLAR WATER HEATERS AND OTHER MISC ITEM UNDER GE (SOUTH) BANGALORE.
Sl. No. Item Description
1Maintenance of swimming pool of capacity 4.5 lakhs gallons by maintainng water parameter as per Indian standard quality tolerance for water including folowing :-(a) Removing /Bailing out sedimentation from bottom of entire swiming pool using suction sweeperbefrore opening swiming pool for users each day on day decided by Engr-in-Charge . (b)Removing all floating particles by usingstrainer before openig swiming pool for users each day / on daysdecided by user and time of cleaning as decided by Engr-in-Charge.(c) Cleaning of cascade system & mixing of chemicals as reqd for swiming pool.
2All as per Item No -1 but swiming pool capacity 2.3 Lakh Gallons
3Supply only following items to be fixed under Sch Item No- 1&2
4Supply only bleaching powder ISI marked superior quality all as specified..
5Supply only Copper Sulphate crystals (ISI marked) suitable for swimming pools all as specified.
6Supply only Sodium carbonate (ISI marked) suitable for swimming pools all as specified.
7Supply only pool Algaecide suitable for swimming pools all as specified.
8Supply only Sodium Hypo Chloride (ISI marked) suitable for swimming pools all as specified.
9Supply only TCCA 90 - chlorine ( ISI ) marked suitable for swimming pools all as specified.
10Servicing pressure filter of capacity25000 LPHby openingpressure filter and taking down filter media of different sizes approximately (10000 Kg)carefully,opening thestrainer and reset the same after replacement of filter mediacleaning filter nozzles with pressure water, refill the filter bed with fresh mediaand cleaning the pebbles /20mm / 10mm / 40 mm / 2mmtopping up the short fall with new media, servicing the backwash system, replacing the un serviceable pressure gauge,testing and commissioning all as directed.
11Servicing pressure filter of capacity 45000 LPHby openingpressure filter and taking down filter media of different sizes approximately (10000 Kg)carefully,opening thestrainer and reset the same after replacement of filter mediacleaning filter nozzles with pressure water, refill the filter bed with fresh mediaand cleaning the pebbles /20mm / 10mm / 40 mm / 2mmtopping up the short fall with new media, including fabrication work inside pressure filter 150mm MS pipe and40mm GI pipe cutting , grinding , weldingand painting work after completion of workservicing the backwash system, replacing the un serviceable pressure gauge,testing and commissioning all as directed.
12Cleaning of balancing tank of swimming pool ofcapacity up to 15000 ltrs by cleaning the balancing tankwith high pressure water jet to remove all masses, algae and dirt, taking out dirt and sludge with sludge machine and disposing the same to a safe distance,scrubbing the internal walls and floor with industrial vacuum cleaner and finally applying anti bacterial sterilization to walls and floor of balancing tank complete all as specified and as directed.
13Supply and fixinginrepalcement of nylon rope of 20 mm dia complete all as specified and as directed.
14Supply and fixingin replcementflexible hose pipe ribbed type high density 40 mm size all as specified.
15Supply and fixingin replcement flexible hose pipes ribbed type high density 50 mm size all as specified.
16Supply and fixingin replcement nylon rope 12 mm dia for the suction sweeper
17Supply and fixingin replcementsuperior quality detachable type telescopic brush suitable for telescopicrod of30mmdia ( bottom 28mm dia )
18M&L for backwashing of swimming pool water through pressure filter start the motor and compete, sludge , particles to backwashpipe line and duct every month once time complete all as specified and directed.
19M&L for pressure jet machine cleaning of water cascade and deep side water inlt pipe and lengeth side holes cleaning through compressed pressure air to liase with BWSSB Jet machine and whenever reqd at site cleaning the blocked holes complete all as specified and directed by Engr in Charge .
20Supply andfixsluice valvesPN 1.6 of size250mm, IS markedthese valves are fixing sandwich type fitting equirement necessary MJ collar Flange joint may be arrange fxing of new valvesall as specified and directed.
21Supply and fixcast iron bodyfoot valve 250mm bore springtypewhich ever be required for fixing including making good disturbed surface and taking out old cast ironfoot valve from the suction sideof the pump set fromswiming pool sump etc. complete all as specified and direct at site.
22Supply andfixsluice valvesPN 1.6 of size100mm, IS markedthese valves are fixing sandwich type fitting equirement necessary MJ collar Flange joint may be arrange fxing of new valvesall as specified and directed.
23Disconnecting the cenrifugal pump set of 10 HP capacity from motor by dis-engaging the coupling , taking out the pump from the foundation and transporting to the workshop, opening the pump, taking out the shaft along with impeller , removing the foreign materials from the inner casing , cleaning checking for wearing out of the impeller , bearing sleeves shaft etc. replaing the worn out parts , assembling the pump complete by replacing the gasket, nuts bolts washers , greasing , greasing of bearings all as required , transporting pump to the site mounting onbase frame , checking for prpoer alignment of pump shaft with motor shaft , adding the the steel sheets as required , checking with dial gauge for correct alignment , connecting the shafts couping and test runing for smoothoperation all specified and as directed.NOTES :- (i) Transportation and necessary T&P for shifting the motor to workshop & back is deemed to be included in the quoted rates.(ii) Major spares like impeller , sleeves etc will be measured and paid under relevent items of this schedule .
24All as per Item No- 17 here in above but 3 HP.
25Supply only the following items to be fixed under itemNo 17 & 18
26CI impeller complete with nut bolt an keymatching with exiting pump at site
27Bearing set for front and rear matching with exiting make at site
28Terminal boardmatching with existing at site
29Shaft matching with exsiting
30S & F in repalcement of suction sweepers of capacity 2 HP mounted on SS304 trolly with controlpanel of sutaible capacity including self priming motor pumpset with flexible hose , 15 Mtr telescopic handle, Aluminium vaccume headfabricated out of anodized aluminium and plastic of size upto 18 inch including multicore wire of appropriate size and length 30 mtrs Complete all as specified and as directed by Engr-In-Charge.
31M&L for laying , connecting & testing single core copper conductor flexible PVC insulated heavy duty unsheathed cable 1100 volts grade10 Sqmm from satrter panel to motor connecting box cutting of existingPCC groove and isert the PVC Conduit pipe suitable size up to motors and connecting the cable all as specified and directed by Engr in Charge
32M&L for laying , connecting & testing singlecore copper conductor flexible PVC insulated heavy duty unsheathed cable 11000 volts grade06 Sqmm from satrter panel to motor connecting box cutting of existingPCC groove and isert the PVC Conduit pipe suitable size up to motors and connecting the cable all as specified and directed by Engr in Charge
33M&L for Preparaton of old surfaces for painting of existing CI/ GI pipeof size up to 200mm by peeling existing paint layer and dust , cleaning of surface , and applying to coats of sytnhetic enamel paint of colour as decided over one coat of red oxide primer on all outdoor sides of pipe complete all as specified and directed by Engr in Charge.
34M/L for maintenance and servicing ofDG SET complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel , drain out engine oil from the sump , flushing the sump thoroughly andreplacing the fuelfilter ements 2 nos ,super bypass filter element 1no, oil filter element 2 nos and filling the starting batterieselecrtrolite to be maintain the required specific gravity, applying the petroleum jelly in battery terminal polesand charging , replacing the diesel tank level tube, cleaning the entire DG set with accessories as prescribed by the manufacturer , checking of voltage ,frequency,amps , fuel, oil , water leveland exhuast leakage etc. Tightening all the bolts & nuts to the required torque ..etc and testing as directed by Engineer In Charge and recording the test result complete forDG set of capacity 250 KVa to 380KVA Complete all as specified and as directed by Engr-In-Charge.Note:- (a) EngineCoolant, filters and belts will be measure and paid seperately .(b) Cost of all minor items ie gaskets grease liner etc deemed to be inlcuded in quoted rate.
35All as per item No-24 but 100 KVA to 160 KVA Complete all as specified and as directed by Engr-In-Charge.
36All as per item No-24 but40KVA to 82.5 KVA Complete all as specified and as directed by Engr-In-Charge.
37All as per item No-24 but up to 35 KVA Complete all as specified and as directed by Engr-In-Charge.
38Supply only followingitems to be fixed under mentioned of above DG sets.
39Air filterselement for DG set of capacity 250KVA to 380 KVA Complete all as specified and as directed by Engr-In-Charge.
40Air filterselement for DG set of capacity 100KVA to 160 KVA Complete all as specified and as directed by Engr-In-Charge.
41Air filterselement for DG set of capacity 40KVA to 82.5 KVA Complete all as specified and as directed by Engr-In-Charge
42Air filterselement for DG set of capacityup to 35 KVA Complete all as specified and as directed by Engr-In-Charge.
43Fuel filterselement for DG set of capacity 250KVA to 380 KVA Complete all as specified and as directed by Engr-In-Charge.
44Fuel filterselement for DG set of capacity 100 KVA to 160 KVA Complete all as specified and as directed by Engr-In-Charge.
45Fuel Filterselement for DG set of capacity 40KVA to 82.5 KVA Complete all as specified and as directed by Engr-In-Charge.
46Fuel filterselement for DG set of capacityup to 35 KVA Complete all as specified and as directed by Engr-In-Charge.
47Lube Oilfilterselement for DG set of capacity 250KVA to 380 KVA Complete all as specified and as directed by Engr-In-Charge.
48Lube Oilfilterselement for DG set of capacity 100KVA to 160 KVA Complete all as specified and as directed by Engr-In-Charge.
49Lube Oil Filterselement for DG set of capacity 40KVA to 82.5 KVA Complete all as specified and as directed by Engr-In-Charge.
50Lube Oilfilterselement for DG set of capacityup to 35 KVA Complete all as specified and as directed by Engr-In-Charge.
51Fan belts matching with existing for DG sets capacity100 KVAto 380KVA Complete all as specified and as directed by Engr-In-Charge.
52Fan belts matching with existing for DG sets capacity up to 82.5 KVA Complete all as specified and as directed by Engr-In-Charge.
53Lubricant Oil 20W40 or as per manufacturerrecommendadtion Complete all as specified and as directed by Engr-In-Charge.
54Coolant of specificatonas per manufacturer recommendationComplete all as specified and as directed by Engr-In-Charge.
55M&L for dismantlingself starter fromDG sets capacity up to 380 Kva and reassembling after replacement of unserviceable items including fixingand testing Complete all as specified and as directed by Engr-In-Charge.Note :- Unserviceable items will be measured and paid seperately .
56Rewinding of stator coils 250KVA to 380 KVA Complete all as specified and as directed by Engr-In-Charge.
57Rewinding of stator coilsup to 160 KVA Complete all as specified and as directed by Engr-In-Charge.
58Replacement ofbearing sets suitable sizeof capacity 250KVA to 380 KVA Complete all as specified and as directed by Engr-In-Charge.
59Replacement ofbearing sets suitable sizeof capacityup to 160 KVA Complete all as specified and as directed by Engr-In-Charge.
60Replacmnet of Gear wheel set completeset Complete all as specified and as directed by Engr-In-Charge.
61M&L for dismantling charging alternator for DG set of any capacity up to 380 KVA and re asssembling after replacement of unserviceable items including testing complete all as specified and directed .Note :- U/S item supply only following items to be fixed under items above .
62Rewinding of starter /rotor coils Complete all as specified and as directed by Engr-In-Charge.
63AC to DC Converter set Complete all as specified and as directed by Engr-In-Charge.
64Supply and fixing in replacement AVR unit for alternator of any capacity matching with existing sample Complete all as specified and as directed by Engr-In-Charge.
65M&L for dismantling of FIP and calibration servicing at admissible pressure for DG set ofany capacity and make including minor spare parts if required Complete all as specified and as directed by Engr-In-Charge.
66M&L for Dismantling of exitor unit assmbly and rewinding of stator/rotor coils including replacement AC/DC connector Complete all as specified and as directed by Engr-In-Charge.
67S&F in replacement control contactors /relay matching with exiting for AMF Panel Complete all as specified and as directed by Engr-In-Charge.
68M&L for replacement of control wiring of AMF with 1.0Sqmm flexible copper conductor single core or as per existingincluding testing Complete all as specified and as directed by Engr-In-Charge.
69Repair/maint of Automatic change over switch of AMF panel by checking logic circuit , replacement of coils or any item reqd for making ACs functional completeall as specified and directed by Engr in Charge.
70Supply and fixing in replacement Governor Controller unit for any capacity DG Set matching with existing sample Complete all as specified and as directed by Engr-In-Charge.
71Supply and fixing in replacement onload change over switch 4 pole, 400 Amps matching with existing Complete all as specified and as directed by Engr-In-Charge.
72Supply and fixing in replacement onload change over switch 4 pole, 200 Amps matching with existing Complete all as specified and as directed by Engr-In-Charge.
73Supply and fixing in replacement onload change over switch 4 pole, 63 Amps matching with existing Complete all as specified and as directed by Engr-In-Charge.
74Supply and fixing in replacement low maintenance Lead acid battery 12 volt 150 AH Complete all as specified and as directed by Engr-In-Charge.
75Supply and fixing in replacement low maintenance Lead acid battery 12 volt 130 AH Complete all as specified and as directed by Engr-In-Charge.
76S&F in replacement brass terminals of battery leadof size and shape matching with existing complete all as specified and directed by Engineer-in-Charge.
77Supply and fixing in replacement of battery copper lead as per existing size. Complete all as specified and directed by Engineer-in-Charge.
78M&L servicing ofExternal Battery Charger12/24 voltsassy by disconnecting the AC supplyand taken to service centre after dismantling the same cleaning all accessories, replace the burnt parts like :- diodes , recifiers and DC & AC fuse units and reassambling the same , refitting the charger including testing Complete all as specified and as directed by Engr-In-Charge.
79M/L for fixing the battery charger 12/24 volt DCas reqd in existing control panelincluding necessary connections , cutting for fixing the volt meter , ammeterand connecting the battery Complete all as specified and as directed by Engr-In-Charge.
80Repair/Maint of radiator assy of DG set by disconnecting and removing from eingine , dismantling the top & bottom chambers , descalling the sediments and scales , corrosion ..etc by means of suitablechemicals and high pressure water washing , air cleaning , re assembling the same with new gaskets, including arresting leakage , if any and fixing to the engine with new hosesclips etc including cleaning the slots as required chemicals and other T&P reqd for job Complete all as specified and as directed by Engr-In-Charge. Note : -Cost of transportation ifany, chemicals and other T&P reqd to complete job is deemed to be inclue in quotedrate.
81250KVAto 380 KVA Complete all as specified and as directed by Engr-In-Charge.
82100 KVA to 160 KVA Complete all as specified and as directed by Engr-In-Charge.
8340 KVAto 82.5 KVA Complete all as specified and as directed by Engr-In-Charge.
84up to 35 KVA Complete all as specified and as directed by Engr-In-Charge.
85S&F in replacement of injector HP pipe from FIP to injector for DG set up to 250 KVAmatching with existing sample complete all as specified and directed by Engrin Charge.
86S&F in replacement Hose pipe for radiator assembly Complete all as specified and as directed by Engr-In-Charge.
87S&F in replacement Flexible pipe for DG set Complete all as specified and as directed by Engr-In-Charge.
88S&F injector asembly for DG set up to 250 KVA Complete all as specified and as directed by Engr-In-Charge.
89M&L for dimantling of defective water pump assembly by disconnecting hose pipe connections , fanbelt, radiator connection and reapairing with seal etc to make leak proof suitable for up to380 Kva DG set Complete all as specified and as directed by Engr-In-Charge.
90S&F In replacement of flywheel ring of up to 250 KVA generator by dismantling alternator from engine removal of unserviceable ring, insertion of new ring on shaft and refixing alternator to Engine duly aligned in position Complete all as specified and as directed by Engr-In-Charge.
91M&L for dismantling of Turbo charger assembly by disconnecting xhaust and Air pipe clening of fan blades , replacement to spacer kit and other minor items complete including refixing in position Complete all as specified and as directed by Engr-In-Charge.
92S&F in replacement of Expansion bellow suitable for DG set up to 250 KVA Complete all as specified and as directed by Engr-In-Charge.
93S&F stop solenoid switch complete including plunger and mounting arrangements 12/24 volts as reqd at site for up to 250 KVA DG set matching with exiting sample complete all as specified and directed .
94M&L forrepairing of DG Set Canopy by fixing broken hinges welding , greasing , repairing , tightining of earthing including new hinges , welding /brazing , greasing if reqd for complete Canopy ofoff sizes of any capacity DG Set complete all as dpeciefied and directed by Engr in Charge.
95M&L for fixing in repair locking arrangement of external doors of DG Set Canopy by providing proper lock mechanism with Key, includingreplacement of lock if reqd complete all as specified and directed by Engr in Charge .
96M&L for Preparaton of oldsurfaces for painting of existing DG Set Control Panel/ AMF Panel ofsize up to 1.7x1.2x0.4mtr by peeling existing paint layer and dust , cleaning of surface , and applying to coats of sytnhetic enamel paint of colour as decided over one coat of red oxide primer on all outdoor sides of LT panel including inner side of gates complete all as specified and directed by Engr in Charge.
97PCC1:2:4 type B-2 using 40mm graded stone aggregate as in pillars , columns ,including caps and bases.necessary form work complete all as specified and directed by Eng-In-Charge.
98S&F in replacement MCCB 3/4 Pole 200 Amps 25 kA, 415 Voltscomplete all as specified and directed by Engr-In-Charge.
99S&F in replacement MCCB 3/4 Pole 250 Amps 25 kA, 415 Voltscomplete all as specified and directed by Engr-In-Charge.
100S&F in replacement MCCB 3/4 Pole 315 Amps 16 kA, 415 Voltscomplete all as specified and directed by Engr-In-Charge.
101Supply and fixing in replacement Automatic Transfer Switch 4 pole 415 volts, 63 Amps with Enclosure, prewired including connectiong with existing system complete all as specified and directed by Engr-In-Charge.
102Supply and fixing in replacement Automatic Transfer Switch 4 pole 415 volts, 125 Amps with Enclosure, prewired including connectiong with existing system complete all as specified and directed by Engr-In-Charge.
103Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium sonductor of size 50 Sqmm x 3.5 core including taking down unserviceable UG cable Complete all as specified and as directed by Engr-In-Charge.
104Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium sonductor of size 95 Sqmm x 3.5 core including taking down unserviceable UG cable Complete all as specified and as directed by Engr-In-Charge.
105Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium sonductor of size 150 Sqmm x 3.5 core including taking down unserviceable UG cable Complete all as specified and as directed by Engr-In-Charge.
106Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete.
107Repair/maint of 1250 ltrs per day capacity Solar flat plate collector type water heater after disconnecting the existing water supply/electrical connections from any height of the buliding dismanting cleaning and serving the aluminium channels /sheets /angles, hot water vessel and solar glass panel including repalcement of defective/worn out components, replacement of insulation and re assembling the box connecting up water connections header/riser pipes nozeels etc cleaning the same materials with anti bacterical descaling and anti corrrision spray painting where ever necessary including brazing and arresting leakages and testing for satisfactory performance complete all as specified and directed by Eng-In-Charge.Notes : (i) Cost of items like brazing, anti bacterial spray, descaling solution, anticorrosion spray and other misc minor items is deemed to be included in quoted rates.(ii) Major items like flat plate collector, broken frame angle iron stand, tank etc if required to be replaced will be measured and paid seperately under respective item of sch.
108All as per item No. 70 above here in before but for capacity 500 ltrs per day complete all as specified and directed by Engr-In-Charge.
109All as per item No. 70 above here in before but for capacity 300 ltrs per day complete all as specified and directed by Engr-In-Charge.
110All as per item No. 70above here in before but for capacity upto 125 ltrs per day complete all as specified and directed by Engr-In-Charge.
111Supply only following items to be fixed under Item No. 71 to 73 complete all as specified and directed by Engr -In-Charge
112Flat plate Collector glass of size upto 2.5 sqm matching with existing compltete all as per site requirmentcomplete all as specified and directed by Eng-In-Charge.
113End cover brass flanged type for collectors matching with existing complete all as specified and directed by Eng-In-Charge.
114Gasket as per sample matching with existing for solar water heater complete all as specified and directed by Eng-In-Charge.
115Heating element for solar water heater up to 500 litres with rubber gasket threaded push type or matching with existing sample 230V upto 3KW complete all as specified and directed by Eng-In-Charge.
116Thermostat suitable of solar water heater up to 500 litres capacity and the range 0 to 80 degree centigrade matching with existing sample complete all as specified and directed by Eng-In-Charge.
117Electric back up kit of solar water heater upto 3 KW including temprature gauge matching with existing sample complete all as specified and directed by Eng-In-Charge.
118Open/Close barrel flanges matching with existing sample complete all as specified and directed by Eng-In-Charge.
119Assistant tank float with ball brass of size matching with existing complete all as specified and as directed by engr-InCharge.
120NRV for solar water heater of any capacity matching with existing sample complete all as specified and directed by Eng-In-Charge.
121Heat transfer fluid/chemical matching with existing specifications complete all as specified and directed by Eng-In-Charge.
122Supply & Lay tubes medium grade galavanised with all fittings laid in trenches /fixed on walls /floors complete of size 40mm dia complete including taking down old GI pipe complete all as specified and directed by Eng-In-Charge.
123Supply & Lay tubes medium grade galavanised with all fittings laid in trenches /fixed on walls /floors complete of size 25mm dia complete including taking down old GI pipecomplete all as specified and directed by Eng-In-Charge.
124Supply & Lay tubes medium grade galavanised with all fittings laid in trenches /fixed on walls /floors complete of size 20mm dia complete including taking down old GI pipe all as specified and directed.
125Supply & Lay tubes medium grade galavanised with all fittings laid in trenches /fixed on walls /floors complete of size 15mm dia complete including taking down old GI pipe complete all as specified and directed by Eng-In-Charge.
126Taking down unserviceable gun metal gate valve, closing tap of any type and size from position complete all as specified and directed by Engr-In-Charge.
127S&F in replacement of Gun metal gate valvewith iron wheel head , screwed both ends for 40mm bore GI pipe , complete all as specified and directed by Eng-In-Charge.
128S&Fin replacement of Gun metal gate valve with iron wheel head , screwed both ends for 25mm bore GI pipe , complete all as specified and directed by Eng-In-Charge.
129S&F in replacement of Gun metal gate valvewith iron wheel head , screwed both ends for 20mm bore GI pipe ,complete all as specified and directed by Eng-In-Charge.
130S&Fin replacementof gun metal gate valvewith iron wheel head , screwed both ends for 15mm bore GI pipe , complete all as specified and directed by Eng-In-Charge.
131S&Fin replacement of closing tap cast copper alloy chromium plated screwed for iron pipes of size 20 mm dia including taking down old complete all as specified and directed by Eng-In-Charge.
132S&Fin replacement of closing tap cast copper alloy chromium plated screwed for iron pipes of size 15mm dia including taking down old complete all as specified and directed by Eng-In-Charge.
133S&F replacement of Rotational Moulded polythelene water storage tanks (Cylinderical verticle with closed top) hoisted and fixed in position of 500 Ltr capacity complete all as specified and directed by Eng-In-Charge.
134S&F of Ball brass valves of sizes 25mm dia high pressure with polythe float and flynut complete all as specified and directed by Eng-In-Charge.
135S&F in Repair/replacement of S/Steel 304 heavy duty tank with Puff insulation , thermo siphon 65 to 70 degree 100Ltr capacity cladding with 22SWG aluminium sheet with taping screws MS channels of adequate thickness with base plates , connecting rubber hose pipes , temprature gauge and connected accessories suitable for 100Ltr capacity solar water heating system including electrical back upup to 3KW testing on pressure complete all as specified and directed by Eng-In-Charge.
136All as sper item No 89 here in befrore but suitable for 300 to 500Ltr capacity per day solar water heater SS tank complete all as specified and directed by Eng-In-Charge.
137Supply and fixing 1100 volts grade heay duty cable PVCinsulated multi standerd 4 Sqmm served with inner sheathing of PVC tape and over all PVC sheathed in service connections wire , 3 core cable complete all as specified and directed by Eng-In-Charge..
138S&Fin replacement of sheet metal enclosure SPN with two pole and earth metal plug and socket 20 Amps 240 Volts including provisions of one single pole MCB 20 Amps complete all as specified and directed by Eng-In-Charge.
139M&L for Checking serviceability of FPC panel choking , cleaning copper tubes and addingheat transfer chemical complete all as specified and directed by Eng-In-Charge.
140Supply and fixing in replacement circulating pump of upto 1 HP matching with existing sample complete all as specified and directed by Eng-In-Charge.
141M&L for Carrying the chocked/ unserviceable/broken/Leak solar panel of any capacity to the local workshop for drilling the solar panel circulation copper tubes for removing the sediment and descaling complete circulation tubes with the helps of recommended chemical/acid and brazing/welding the drilling portion and broken or leaking part of tubes to make leak proof and serviceable complete all as spicified and directed by Engineering - in- charge.
142Supply and fixing inreplacement of solar panel cirulation copper tubing set copmlete (including welding strip/sheet of standard size and Flanged joints ) all as per site requirement and as directed by Engr-in -Charge.
143S&F in replacament stainless steel water makeup tank of cap connected with main stainless steel tank of size matching with existing complete all as specified and directed by Eng-In-Charge.
144PCC1:2:4 type B-2 using 40mm graded stone aggregate as in pillars , columns ,including caps and bases.necessary form work complete all as specified and directed by Eng-In-Charge.
145S&F in replacement of Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore complete all as specified and directed by Engineer-In-Charge
146Supply errection and fabrication of nut , bolts , washers, collector legs , clamps , screws fabricated from structuralsteel section includingwelding,bending cold or hotdrilling holes for bolts including painting with stove enamelled paint over a coat of red oxide in any shape or size as indicated or complete all as specified and directed by Eng-In-Charge..
147Supply and fixing in replacement Stand suitable for fixing Solar panels of Size upto 2.5 sqm fabricated out of angle iron of size matching with exisitng with no of required legs inclined to angle as existing including providing grouting with ground/roof with pcc pedestals complete all as specified and directed by Engr-In-Charge.
148M&L for prunning of trees/branches/bushes coming above the solar panels for providing direct sunlight using suitable T&P and shifting broken bushes to nearby dumping point complete all as specified and directed by Eng-In-Charge.
149S & F in replacement evacuated tube solar collector tubes sutaible for ETC panels of solar water heater of capacity upto 500LPD matching with existing sample including taking down existing unserviceable tubes with mounting provision and testing on complete. complete all as specified and as directed by Engr-In-Charge.
150S & F in replacement solar flat plate collector flat rectangular shaped with transperent glass coat duly glazed including absorber plate of highly conductive material dully coated and insulated to minimizeheat losses including fluid circulation system duly filled with antifreeze solution / water as per existing with inlet and outlet ports for connection solar flat plate collector of mounting strucure shape and size matching with existing fixed inside frame including matching with existing complete all as specified and as direcet by Engr-In-Charge.
151Supply, install, connecting, testing and commissioning in replacement oh high pressure single head adjustable dosing system of the following specification : Adujstable high pressure 5 kg / sq cm power input 230V, 50 HZ, 40spm 1 / 30 fractyional horsepower, max output 10 ltr/ hr with mandatory accessories like lead tubing, connecting ferrules, check valve. (1) Preparation tank of net capacity 100 ltrs, FRP dosing tank with stang consisting of : Water inlet line, Outlet with stainer, Drain, Overflow, Conical bottom for sludge deposition, Pot hole with cover, Level gauge, Agitator 120 watt 900 RPM 1 phase flange mounted motor with plastic shaft and impeller. (2) Service tank net capacity 100 ltrs consisting of : Water inlet line, Dosing pump inlet arrangement, Drain, Overflow, Level gauge, Inspection port, Agitator 120 watt 900 RPM 1 phase flange mounted motor with shaft and impeller, Provision of mounting pump on lid / wall

AI Tender Summary

OUR REF NO 51955905
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 22-11-2025
Authority
Authority Name Military Engineer Services
Work Description Comprehensive Maintenance Of Swimming Pools, Filtration Plant, Dg Sets, Solar Water Heaters And Other Misc Item Under Ge (South) Bangalore.
Basic Detail
Tender No 8964/E8
Bidding Type Tender
Location
City bangalore
State Karnataka
Key Dates
Publish Date 15 Nov 2025
Submission Date 22 Nov 2025
Open Date 24 Nov 2025
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
0e3491da-8456-4356-bff9-69de795cc50d.html
BOQ_824802.xls
Tenderdocument8964.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 15, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 22, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 22, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 24, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

0e3491da-8456-4356-bff9-69de795cc50d.html

xls

BOQ_824802.xls

pdf

Tenderdocument8964.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders