Tender For Provision Of Certain Sr/Mr/Mw Works Under Age Br (P), Br-(Ii) And Age (E/M) At Af Station Bhuj; 1 Taking down cement plaster of any description on brick walls , cement surfaces including raking out joints hacking for key secrubing down with water remove dust, debries/rubbish etc complete all as specified and directed by Engineer-in-Charge. 2 Material & labour for 5 mm thick rendering for fair faces of concrete surfaces on ceiling in CM 1:3 for fair finished surfaces including finished even and smooth without using extra cement. complete all as specified and directed by Engineer-in-Charge 3 Material & labour for 10 mm thick rendering for fair faces of concrete surfaces on walls in CM 1:6 and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge 4 Material & labour for rendering 15mm thick in Cement Mortar 1:4 (External) on brick walls or on concrete surfaces in two coats, 1st coat of 10mm thick and 2nd coat of 5mm thick including mixing with WPC to 2nd coat as per manufacturers instructions, plastered surfaces finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.NOTE : Integral water proofing compound shall be Measured and paid separately as ‘Supply only’ under relevant Items. 5 Supply only integral water proofing compound ISI marked complete all as specified and directed by Engineer-in-Charge. 6 Material & labour for preparing new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge. 7 Material & labour for preparing new plastered wall surfaces and applying two coats of distemper with distemper oil emulsion, white or tinted including one coat of wall primer by finishing the surfaces even and smooth complete all as specified and directed by Engineer-in-Charge. 8 Material & labour for preparation of new or previously untreated concrete or PCC block masonry external surfaces and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and directed by Engineer-in-Charge. 9 Material & labour for preparation of old treated surfaces of wall including brooming down, scrapping down smoke soots etc. and appying one coat of white wash complete all as specified and directed by Engineer-in-Charge. 10 Material & labour for preparation of old treated surfaces of ceiling including brooming down, scrapping down smoke soots etc. and appying one coat of white wash complete all as specified and directed by Engineer-in-Charge. 11 Material & labour for preparation of old treated surfaces of wall surfaces and applying one coat of distemper with distemper oil emulsion white or tintedcomplete all as specified and as directed byEngineer-in-Charge. 12 Material & labour for preparation of old treatedwall surfaces including brooming down and applying one coat of exterior emulsion paint complete all as specified and directed by Engineer-in-Charge. 13 Material & labour for preparation of old wooden painted surfaces of any description exc 10 cm width or girth and appying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. 14 Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. 15 Material & labour for 25mm thick cement concrete type BO 1:2:4 using 12.5mm graded aggregate in sub base floors complete all as specified and directed by Engineer-in-Charge. 16 Material & labour for mat finish coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge. 17 All as per item No 16.00 but on vertical surfaces such as in skirting and dados laid over plaster ijn CM 1:4 complete all as specified and directed by Engineer-in-Charge. 18 Material & labour for non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge. 19 Material & labour for glazed ceramic coloured tiles in vertical surfaces such as in skirting and dados 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over plaster in CM 1:4 complete all as specified and directed by Engineer-in-Charge. 20 Material & labour for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge. 21 Supply & fix in repairs 25 mm bore stainless steel heavy duty drapery rod (curtain rod) including all fittings and fixers , cut to length and fix in position including decorative type finals (bracket) colored finish, of approved pattern by GE complete all as specified and directed by Engineer-in-Charge. 22 Taking up on down steel tubing and connection incl cleaning for refining of the following bore of pipe complete all as specified and directed by Engineer-in-Charge of following size :- 23 15mm bore 24 20mm bore 25 Supply & fix CPVC pipes ISI marked, IS-15778 with all fittings for hot and cold water, fixed with solvent cementcomplete to walls and ceilings or laid in floors of complete all as specified and directed by Engineer-in-Charge of following size :-(SDR-13.5 ) 26 15mm dia 27 20mm dia 28 Dismantling of cast iron, PVCor reinforced concrete pipes jointed in cement mortar and taking out of trenches, if required complete all as specified and directed by Engineer-in-Charge following bore of pipe 29 100/110mm dia 30 75 mm dia 31 Supply & fix PVC ultra drain,SelFit pipes, single socketed, ISI marked, IS-13592 type B in any length, jointed with solvent cement fixed in walls and floors complete all as specified and directed by Engineer-in-Charge of following size :- 32 110mm dia 33 75 mm dia 34 Supply & fix PVC junction single Tee equal with door opening, ISI marked, IS-14735, jointed with solvent cement complete all as specified and directed by Engineer-in-Charge of following size :- 35 110mm dia 36 75 mm dia 37 Supply & fix PVC sockets equal, ISI marked, IS-14735, jointed with solvent cement complete all as specified and directed by Engineer-in-Charge of following size :- 38 110mm dia 39 75 mm dia 40 Supply & fix PVC bend equal of any radius with door, ISI marked, IS-14735, jointed with solvent cement for 75mm size pipes complete all as specified and directed by Engineer-in-Charge. 41 Supply & fix PVC bend equal of any radius without door, ISI marked, IS-14735, jointed with solvent cement for 110mm size pipes complete all as specified and directed by Engineer-in-Charge. 42 Supply & fix stainless steel sink with drainage board, made out of 1 mm thick sheet for kitchen or laboratory with plug washer waste pipe cast iron cantilever brckets connecting union overall size 915mm x 460 mm with bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed by Engineer-in-Charge. 43 Supply & fix in repairs stainless steel plate rack made out of 1mm thick stainless steel sheet, overall minimum size 60cm x 90cm and for 6 plates as approved by GE complete all as specified and directed by Engineer-in-Charge. 44 Supply & fix in repair rotational moulded polythene white water storage tank tripple layared (cylindrical , vertical with closed top , ISI marked , ) hoisted and fixed in position all as specd in SSR Part 1 of capacity 500 ltrs including taking down existing tank also including provision of 20 mm bore ball valves , high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum wt 455 gms) complete all as specified and directed by Engineer-in-Charge. 45 Supply & fix in repairs for grating square 150mmx150mm size of stainless steel complete all as specified and directed by Engineer-in-Charge. 46 Supply & fixin repairs vitreous china wash basin, angle back, size 550x400mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed by Engineer-in-Charge. 47 Supply & fix in repairs for pillar taps of 15 mm bore, fancy type with capstan head, chromium plated, screwed down high pressure, with long screwed shanks and fly nuts, screwed for iron pipe & fixed complete all as specified and directed by Engineer-in-Charge. 48 Supply & fix waste pipe of 32mm dia PVC pipe for WHB with long screwed shanks and fly nut flange end beddedd in red lead cement and other end fixed complete all as specified and directed by Engineer-in-Charge. 49 Supply & fix in repairs for bevelled edge mirror of size 600mm x 450mm selected quality glass mounted on6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge. 50 Supply & fix in repairs for vitrious china squattin pan ,Orissa Paattern Size 580x440 mm white with integral foot rests ( Excluding flushing cistern and flush pipe) complete all as specified and directed by Engineer-in-Charge. 51 Supply & fix in repairs PVC low level valveless, syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of 10 Ltr capacity complete all as specified and directed by Engineer-in-Charge. 52 Supply & fix in repairs for bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for size15mm bore complete all as specified and directed by Engineer-in-Charge. 53 Supply & fix in repairs stop valve 15 mm dia cast chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge. 54 Supply & fix in repairs for brass CP mixer for mixing hot and cold water screweddown for iron pipe and fixed for size 15 mm bore complete all as specified and directed by Engineer-in-Charge. 55 Supply & fix in repairs for shower rose for 15 mm dia, 125mm long, cast chromium plated screwed down high pressure with long shank screwed end for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge. 56 Supply & fix PVC connection 450mm long with check nut for wash hand basin etc complete all as specified and directed by Engineer-in-Charge. 57 Taking down chowkhat or frames with shutter (without taking off shutters from the frames)n exc 1.5 sqmcomplete all as specified and directed by Engineer-in-Charge. 58 Taking down chowkhat or frames with shutter (without taking off shutters from the frames) exc 1.5 sqm but n.exc 4.00 sqmcomplete all as specified and directed by Engineer-in-Charge. 59 Supply & fixpressedsteel frames of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock stricke plate etc complete all as specified and directed by Engineer-in-Charge. 60 Supply & fix pressedsteel frames of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock stricke plate etc complete all as specified and directed by Engineer-in-Charge. 61 Material & labour for providing cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregate) as in roof kerbs, mud stops, filling in frames and the like rounded or or chamfered on edges complete all as specified and directed by Engineer-in-Charge. 62 Supply & fix 35mm thick 2nd class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc, with sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/ Gauge etc. Size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a) complete all as specified and directed by Engineer-in-Charge. 63 Supply & fix stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed wih SS wire staples complete all as specified and directed by Engineer-in-Charge. 64 Supply & fix 35mm thick 2nd class hard wood factory made plain framed, paneled shutters (any number of panels), with lock rail and panel of 9mm BWP commercial ply or 12mm veveered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (part-I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge. 65 Supply & fix Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening complete all as specified and directed by Engineer-in-Charge. 66 Supply & fix factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and directed by Engineer-in-Charge. 67 Supply & fix preparing new or previously untreatedsteel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide or zinc chrome primer on steel surfaces complete all as specified and directed by Engineer-in-Charge. 68 Dismantling old unserviceable kitchen cupbord shutter with frame complete all as specified and directed by Engineer-in-Charge. 69 Material & labour for prelaminated particle board 18mm thick interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work fixed for cuboards/shelfs/partitons etc complete all as specified and directed by Engineer-in-Charge. 70 Supply & fix SS plate rack(size- 45 Cm x50 Cm x 20 Cm /4mm dia SS rod)with necessary fitting like slider etc complete all as specified and directed by Engineer-in-Charge. 71 Supply & fix SS crockery rack (size- 45 Cm x50 Cmx 20 Cm /4 mm dia SS rod with necessary fitting like slider etc complete all as specified and directed by Engineer-in-Charge. 72 Supply & fix SS bottle rack (size-25 Cm x 50 Cmx45 Cm/ 4 mm dia SS rod) with necessary fitting like slider etc complete all as specified and directed by Engineer-in-Charge. 73 Supply & fix self clossing hinges 75 mm long complete all as specified and directed by Engineer-in-Charge. 74 Supply & fix magnet lock 30 mmm long complete all as specified and directed by Engineer-in-Charge. 75 Supply & fix 100 long SS fancy type handle complete all as specified and directed by Engineer-in-Charge. 76 Supply & fix butt hinges 75mm size, medium weight, cold rolled mild steel complete all as specified and directed by Engineer-in-Charge. 77 Supply & fix butt hinges 100mm size, medium weight, cold rolled mild steel complete all as specified and directed by Engineer-in-Charge. 78 Supply & fix 150mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge. 79 Supply & fix 100mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge. 80 Supply & fix aluminium, anodised barrel tower bolt of extruded section and fixed 150mm of size complete all as specified and directed by Engineer-in-Charge. 81 Supply & fix aluminium, anodised 100mm size of hasp and staple, safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer-in-Charge. 82 Supply & fix floor door stopper of brass body and tongue with hard drawn steel spring, overall length of cover plate 150mm and fixed complete all as specified and directed by Engineer-in-Charge. 83 Supply & fix mild steel 300mm long ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge. 84 Material & labour for aluminium window with double side hungshutter forglazing and gauging and frame with one or more rebates made out anodised aluminium section including section for fixing of aluminium grills with suitable fixtures, jointing cleats for fixing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminiumbeading screws, type B20 100mm long suitable handle and anodised aluminum fittings such asstay, hinges glazing with 5 mm thick tinted sheet glass and gauging with aluminium wire cloth of size 0.45mm dia of wire and 1.40mm aperture as per drg No. CEAA/TD/133 sheet No. 1/2 and 2/2 dated 13.12.02 except fixed glazing (FG) complete all as specified and directed by Engineer-in-Charge.(Tint of glass shall be approved by GE)Note :- Aluminium grill fixed under aboveitem shall be measured and paid separately. 85 Supply only aluminium anodised grill of approved shape with opening in grill 66mm x 80mm (diagonally) or nearest to + 5mmmade out of standard aluminium moulded section of size 6mm x 7mm complete all as specified and directed by Engineer-in-Charge. 86 Removing of old water proofing treatment including screed bed and cleaning the surface of slab with wire brushes removing dust, foreign materials including flushing at junction of wall and removing the rubbish off the premises to a distance exc. 500m, complete all as specified andas directed Engr-in-Charge. 87 Material & labour for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in roof kerbs/coping/ bed block / depression complete all as specified and directed by Engineer-in-Charge. 88 Material & labour for 15mm thick rendering in cement mortar 1: 4 on faces of brick work or concrete surfaces with WPC, finished even and smooth W/O using extra cement as in roof complete all as specified and directed by Engineer-in-Charge. (WPC shall be measured & paid seperately) . 89 Supply only integral water proofing compound. (ISI marked) complete all as specified and directed by Engineer-in-Charge. 90 Material & labour for water proofing treatment onroofand preparing the surfaces to receive WPT treatment , applying cold bituminous primer@ 0.30 ltr / Sqm conforming to IS 3384 applied on plastered surfaces including side walls , followed by a layers of APP based polymeric membrane reinforced with polyster non woven fabric (weighing 3.5 Kg/Sqm(minimum) and 3 mm thick) with mineral finish laid on primed surface by torch application with side overlap 100 mm and ends over laps 150 mm , joints sealed properly as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge. 91 Material & labour for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by Engineer-in-Charge. 92 Removal of damaged concrete along with loose damaged and cracked concrete/cover concrete at ceiling up to beyond the corroded steel reinforcements to a depth of10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer,pneumatic chippers including high pressure water jetting to chipped concrete and reinforcement and removal and disposal ofdebris within owners premises including all plant and machineries. Note : Rates quoted for all items should include working upto 6m height including all necessary scaffolding , staging etccomplete all as specified and directed by Engineer-in-Charge. HSE Guidelines : Recommended to wear tightfitting,dust-resistant goggles and mask during breaking and surface grinding works etc 93 Material & labour for cleaning as directed & specified all rust/ scales/corrosion from reinforcement bars using rust remover Reebaklens RR- Rust remover, cleaning and etching agent supplied in 1/2, 1 and 5 Litre containers, having Specific Gravity 1.16 - 1.22 @ 25°C. Reebaklens RR cleaning agent is a combination of acid based material, corrosion inhibitors and dispersing agents and is supplied as a clear green solution.Application of Reebaklens RR with brush for complete wetting of rusted metal surface and allowed to react it for 16-24 hours followed by cleaning the surface with wire brush and washing surface with fresh water as required to exposed reinforcement bars complete as specified.Note : Rates quoted for all items should include working upto 6m height including all necessary scaffolding , staging etc complete all as specified and directed by Engineer-in-Charge.HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact.. 94 Material & labour for TMT steel bars , Cutting, fabricating new reinforcement Fe500 and fixing with old existing reinforcement which was reduced to 20 % or more of its original diameter as provided in original structure and additional steels as directed by EIC to be fixed with chemical anchor grout Lokfix E55- Styrene free vinyl-ester resin based cartridge system for anchoring reinforcement supplied in 300 ml cartidge with a single mixer nozzle, application inclueds drilling hole close to old reinforcement bar with suitable drill as per dia of bar, cleaning the hole with wire brush and compressed air, putting Lokfix E55 with gun followed by placing rebar with slide rotational motion to avoid air void formation etc complete as directed by EIC.(i) for 8mm dia (min embedment depth 80mm) (ii) for 10mm dia(min embedment depth 90mm) (iii) for 12 mm dia ( min embedment depth 110 mm) (iv) for 16 mm dia ( min embedment depth 125 mm) Note : Rates quoted for all itemsincluding all necessary scaffolding , staging etccomplete all as specified and as directed. HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. 95 Material & labour for Epoxy Bond Coat Providing and applying bond coat on the prepared surface to receive polymer modified mortar/polymer modified micro concrete, with two component epoxy based bonding coat Nitobond EP- Epoxy resin concrete bonding agent supplied in 1/2, 1 and 4 Litre packs, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs and 30 ̊C, High bond strenght High bond strength : Bond strength is more than the tensile strength of good quality concrete, Barrier coat : Acts as a ‘barrier coat’ to the migration of chloride ions from host concrete. Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. The bond coat act as a bonding coat between old and new concrete. Typical application includes cleaning all loose dust, dirt, grease from host concrete surface by suitable means, mixing both components of bond coat by heavy duty slow speed mixer until a uniform consistency, apply unbroken coat of Nitobond EP with stiff brush covering complete area of patch repair before placing mortar or micro concrete. Item rate is inclusive of materials all labour, tools and tackles, 96 scaffolding and transportation etc. complete as per specification and as directed by Engg.-in-charge. Note : Rates quoted for all items should include working upto 6 m height including all necessary scaffolding , staging etccomplete all as specified and as directed.HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. Barrier creams provide additional skin protection. Do not smoke during use. Maintaine ample ventilation. If contact wiith the resin occurs, wash immediately with a strong detergent or a resin removing cream. Eye contamination must be immediatelywashed with plenty of water and medical treatment sought. complete all as specified and directed by Engineer-in-Charge. 97 Material & labour for Polymer modified Mortar-Patch repair (Up to Grade M45) Providing and laying Renderoc SP 40- shrinkage controlled polymer modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar supplied in 25 kg moisture resistant bag when mixed with clean water at w:p ratio 0.18, achieves compressive strength (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days, Tensile Strength(BS 6319 Pt.7) > 2.5 Mpa at 28 Days, Flexural Strength(BS 6319 Pt.3)>7 Mpa at 28 days, Drying shrinkage to ASTM C 157-93, 28 days < 1000 microstrain. Typical application inclues mixing entire bag with clean water about 4.25L to 4.5 L, mixed in suitable container with heavy duty slow speed mixer machine to achieve uniform lump free mortar consistency, placing and finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface on the beams, slabs, piles etc., where the thickness of application is less than 50 mm in patches as per specification after applying bonding coat. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. complete as per specification and as directed by Engg.-in-charge. 98 Note : Rates quoted for all items should include working upto 14m height including all necessary scaffolding , staging etccomplete all as specified and as directed.HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles and mask if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact 99 Pulling down the existing U/S wires of any type from concealedwiring carefully of aluminium point wiring (light, fan, bell, socket, power point etc.) with or without conduit, along with all connected accessories such as ceiling rose, switches, sockets, switch boards, fan regulator etc complete all as specified and directed by Engineer-in-Charge. 100 Pulling outsub main wiring only any size of aluminium conductor cable PVC insulated with or without condiut complete all as specified and directed by Engineer-in-Charge. 101 Material & labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through and including PVC CASING & CAPPING INCLUDING accessories etc including fixed to wall/ceiling including provision of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with PVC surface box complete all as specified and directed by Engineer-in-Charge for:- 102 One light point controlled by one, one way switch single pole piano type. 103 One Fan point controlled by one, one way switch single pole piano type. 104 One 3 pin 5 Amp socket outlet on the same board. 105 One 3 pin 5 Amps socket out let on independent board. 106 One bell point controlled by one bell push on independent board. 107 All as per item No.87.00 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board complete all as specified and directed by Engineer-in-Charge. 108 Material & labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through existing conduit including provn of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with new plastic laminated white coloured top sheet cover 3.0 mm thick on existing sunken box complete all as specified and directed by Engineer-in-Charge for:- 109 One light point controlled by one, one way switch single pole piano type. 110 One Fan point controlled by one, one way switch single pole piano type. 111 One 3 pin 5 Amp socket outlet on the same board. 112 One 3 pin 5 Amps socket out let on independent board. 113 One bell point controlled by one bell push 114 All as per item No.6 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board complete all as specified and directed by Engineer-in-Charge. . 115 Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through and including PVC casing capingISI marked with accessories and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit) 116 Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 6 Sqmm single core, copper conductor drawn through and including PVC casing capingISI marked with accessories and 6 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit) 117 Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor in existing conduit drawn through and including PVC casing capingISI marked with accessories and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit) 118 Supply & fix in replacement energy saving, evironment friendly, long life, corrosion resistent, impact proof, Mini LED building securitylight made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LEDs with secondary optics and IP 65 protection with LED 20 W light source including material and labour for suitable bracket made of 20 mm dia light grade GI pipe & MS clamps complete with nuts and bolts and washers complete all as specified and directed by Engineer-in-Charge. 119 Supply and fixingin repairs wall mounted decorative ultra slimLED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 10 W 2 ft indoor decorative (white) with 2 Core copper wire from ceiling rose to light fitting complete all as specified and directed by Engr-in-Charge 120 Supply and fixingin repairs wall mounted decorative ultra slimLED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 18/20 W 2 ft indoor decorative (white) with 2 Core copper wire from ceiling rose to light fitting complete all as specified and directed by Engr-in-Charge 121 Supply & fixing in replacement of LED Lamp, 7 W ,Type of cap B22, wideoperating range 140V -280V, Input current 08mA- 30mA, lumen 180-300, UV and IR free light, color temperature 6500K, cool day light, up to 80 % energy saving over GLS complete all as specified and directed by Engineer-in-charge. 122 Supply & fix in replacement double door sheet metal enclosures factory made DBsprotection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 triple pole and neutral 4 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engineer-in-charge. 123 Supply & fix in replacement double door sheet metal enclosures factory made DBsprotection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 single pole and neutral 08 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engineer-in-charge. 124 Supply & fix in replacement of isolators/MCBs, etc. In distribution board of the following rating and capacities complete all as specified and directed by Engineer-in-Charge of following:- 125 MCB TPN 415 volts 63 Amps Capacity, 10 KA 126 MCB SPN of 240 volts 20/32/40 Amps Capacity, C series, 10 KA 127 MCBSP of 240 volts 5-40 Amps Capacity, C series, 10 KA 128 MCBSP of 240 volts 6-32 Amps Capacity, C series, 10 KA 129 Supply & fix in replacementcapacitor of capacity 2.5 mfd (PVC Body) suitable for ceiling/exhaust fans/wall mounted fans of any description,any sweep complete all as specified and directed by Engineer-in-charge. 130 Taking down and refixing ceiling fans/exhaust fan of any sweep any size from site for repair complete all as specified and directed by Engineer-in-charge. 131 Material & labour for taking out & removing old burnt-out windings of Ceiling fans of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by Eng-in-charge including insulating material such as illuminous paper,Letherized paper,cotton tape,glass sleeving,insulating varnish ,Bearing ,Bushes,capacitor etc.and transportation to site after testing at workshop,connecting and testing on full load to the entire satisfaction of Eng-in-charge,including painting of fans of any description(ceiling fan/exhaust fan/wall mounte fan/pedestal fan) with applying one coat of synthetic enamel paint(white/Grey) by spray machine including preparation of exisiting decorated surfaces of fans complete all as specified and directed by Engineer-in-charge. . 132 Material & labour for servicing of 1200/1400MM ceilingfan by dismantling carefully and taking out unserviceable parts, dust & grease, cleaning of internal parts with kerosene oil, washing, checking of alignment of shaft, oiling and re-greasing of bearing/bushes including replacing of unserviceable part like bearing ,gun metal bush, capacitor,Rubber reel of suitable capacity and re-assembling the same and complete all as specified and directed by Engineer-in-charge. 133 Supply & fix in replacement of PVCbody exhaust fan, AC single phase 230/240V of size 250 mm sweep with louvers including making hole of suitable size/ alteration to the existing hole to fix the Exhaust fan complete all as specified and directed by Engineer-in-charge.(Note: Old unserviceable Exhaust Fan will be deposited in MES store yard). 134 Supply & fix in replacement bell, AC, 230 V, SP, ding dong type complete all as specified and directed by Engineer-in-charge. 135 Supply & fix in replacement stepped type electronicfan Regulatorflush type on the existing phenolic laminated etc as reqd single pole 240 volts grade 350 watts heavy duty ISI marked complete all as specified and directed by Engineer-in-charge. 136 Supply & fix in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-charge. 137 Supply & fix in replacement of Ceiling rose 3 phase, PVC/ Polycarbonate body complete all as specified and directed by Engineer-in-charge. 138 Supply & fix modular plastic surface box of module 1/2 flush type ISI marked complete all as specified and directed by Engineer-in-charge. 139 Supply & fix modular plastic surface box of module 3 flush type ISI marked complete all as specified and directed by Engineer-in-charge. 140 Supply & fix modular plastic surface box of module 4 flush type ISI marked complete all as specified and directed by Engineer-in-charge. 141 Supply & fix modular white cover plate with frame of module 1 flush type ISI marked complete all as specified and directed by Engineer-in-charge. 142 Supply & fix modular white cover plate with frame of module 2 flush type ISI marked complete all as specified and directed by Engineer-in-charge. 143 Supply & fix modular white cover plate with frame of module 3 flush type ISI marked complete all as specified and directed by Engineer-in-charge. 144 Supply & fix modular white cover plate with frame of module 4 flush type ISI marked complete all as specified and directed by Engineer-in-charge. 145 Supply & fix modular white cover plate with frame of module 6 flush type ISI marked complete all as specified and directed by Engineer-in-charge. 146 Supply & fix modular white cover plate with frame of module 8 flush type ISI marked complete all as specified and directed by Engineer-in-charge. 147 Supply & fix modular blank plate module 1 complete all as specified and directed by Engineer-in-charge. 148 Supply & fix in replacement, modular switch flush type, 6 Amp. SP, one way ,1 module complete all as specified and directed by Engr-in-Charge. 149 Supply & fix in replacement modular socket outlet, 3 pin, 6 Amp, flush type 2 module complete all as specified and directed by Engr-in-Charge 150 Supply & fix in replacementmodularswicth, 16 Amp flush type 1 module complete all as specified and directed by Engr-in-Charge. 151 Supply & fix in replacementmodularsocket outlet, 3 pin, 6/16 Amp flush type 2 module complete all as specified and directed by Engr-in-Charge. 152 Supply & fix in replacementmodularbell push, flush type, 6 Amp,1 module complete all as specified and directed by Engr-in-Charge. 153 Supply & fixin replacement of ceiling fan regulator modular type electronic step type 5 step 360 deg 120 watt 2 module complete all as specified and directed by Engr-in-Charge. 154 Material & labour for disconneting electrically and mechanically the existing geyser of any description,any capacity and make/type and in any position for repair/replacement/painting/cleaning etc including disconneting existing cold and hot water pipe connections, strip opening of geyser for descaling of tank element, thermostate,inlet/outlet water pipe connection etc using suitable chemical/wire brush,replacement of unserviceabe parts, re-assembling the same after, repair/descaling, fixing in position including, connecting inlet/outlet water pipe connection, electrical connections any testing of geyser complete all as specified and directed by Engineer-in-charge. 155 Supply & fix in replacement metal plug top 20Amps 3 pin complete all as specified and directed by Engineer-in-charge. 156 Supply & fix in replacement 2.0 KW Electric heating elementat site including rubber ring washers ISI marked complete all as specified and directed by Engineer-in-charge. 157 Supply & fix in replacement for PVC connection with brass nipple 15 mm x 450 mm long for geyser 25/50 ltrs capacity as per sample complete all as specified and directed by Engineer-in-charge. 158 Supply & fixin replacement of 15mm bore bib taps ISI marked cast copper alloy fancy type chroumium plated with crutch butterfly handle screw down for iro n pipe or brass ferrule complete all as specified and directed by Engineer-in-charge 159 Material & labour for shifting of transformer/ voltage stabilizer upto 200 KVA capacity from one location to other location of any capacity including removing the existing HT/LT/removing and refixing of connectors mounted on wall connection of any type transformer and transporting the same to desired location within airforce stn bhuj. The same installing connecting HT/LT cables, earthing testing and commissioningcomplete all as specified and directed by Engineer-in-Charge. 160 Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 240 sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. 161 Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 50 sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. 162 Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 16 sqmm, 4.0 core complete all as specified and directed by Engineer-in-Charge. 163 Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge. 164 Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge. 165 Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by Engineer-in-Charge. 166 Material & labour for sand cushioning for UG cables using dry river sand; gently punning down complete all as specified and directed by Engineer-in-Charge.( Note : For measurement purpose punned thickness shall be considered) 167 Supply & lay ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flate size 300mm X 180 mm X 40 mm in trenches as protection to LT UG cable complete all as specified and directed by Engineer-in-Charge. 168 Material & labour for heat shrinkable indoor/ outdoorLT end terminations for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing etc of cable size 35 to 240 Sqmm, 3.5 core complete all as specified and as directed by Eng-in-Charge. 169 Supply & fix fabricating LT panel indoor type, dust and vermin proof totally enclosed with sloping canopy fabricated out of steel section the door opening shall not be less than 150 degree. The construction of panel board shall be dust vermin proof IP 54 standard double shutter gears front and rear frame work and 3.15 mm thick MS sheet duly painted with powder coated over two coats of red oxide primer and madeof 40x40x6 mm thick angle iron frame all as specified suitable for 415 volts 50 Hz 3 phase and neutral system and shall be complete with 400 Amps capacity copper bus bar with bus bar chamber internal wiring with suitable size of PVC insulated copper cable lugs comprising of following accessories-:IncomingMCCB 4 pole 350 Amps 36 KA-01 Nos OUTGOING(i) MCCB 4 pole 200 Amps 36 KA-02 Nos(ii) MCCB 100 Amps 16 KA 4 pole-03 NosDigital type Ammeter with CT 0-400-01 NoDigital type Voltmeter 0-500-01 NoIndicator-RYB 170 Supply & fixindustrial plug and socket 3P+E+N, 415 volt, 16 Amps rating code No DHDPBTN016 complete all as specified and directed by Engineer-in-charge. 171 Supply & fix in replacement FRP juction box of size outside dimensions 400 x 300 x 190 mm with 4 nos copper busbar of capacity 100 Amps , length 250 mm ,01 No MCCB of 100 Amps capacity inside the boxas approved by the Engineer-in-Charge including connectorand fixing on pole/wall with and including MS clamps made out of 25 x 3mm MS flat iron, nut, bolts etc complete all as specified and directed by Engineer-in-ChargeNote:- The cost of sintex box installation includes making hole of suitable size for entry and exist of cable any size, making new lugs of cables of entry and exit including cable glands. 172 Supply & fix copper strip 32 x 6 mm with saddles and fixing screws etc.for jointing with earth pits complete all as specified and directed by Engineer-in-charge 173 Supply & install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and ISEER value more than 5.00 of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge.Note:- (i) Cost of stand for outdoor unit is included in this item.(ii) Cost of copper tubes from indoor to outdoor as per site requirement is included in this item.(iii) Cost of drain pipe from indoor/outdoor as per site requirement is included in this item. 174 Supply & fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 140 V to 270 V with output voltage stablized at 230 V with low and high cutoff facility including under and over current protection with accurancy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed by Engr-in-Charge. 175 Supply & fix PVC clad enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed byEngineer-in-Charge. 176 Supply & fix in replacement modular switch 5 Amps/6 Amps flush type 1 module complete all as specified and directed by Engineer-in-Charge. 177 Supply & fix in replacement modular switch 5 Amps/6 Amps flush type 2 module complete all as specified and directed by Engineer-in-Charge. 178 Supply & fix in replacement modular switch 16 Amps flush type 1 module complete all as specified and directed by Engineer-in-Charge. 179 Supply & fix in replacement socket 6A/16A-2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge. 180 Supply & fix in replacement modular white cover plate with frame of module 3 flush type ISI marked complete all as specified and directed by Engineer-in-charge. 181 Supply & fix in replacement modular plastic surface box of module 3 flush type ISI marked complete all as specified and directed by Engineer-in-charge. 182 Material & labour for one light point/ fan point controlled by one , one way flame proof switch surface wiring complete with 1.5 sqmm single core multi stranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade drawn through ERW steel conduit heavy duty ISI marked of size 20 mm including dia accessories like tees, bends elbows, reducers bell mouth tube ends and fixing accessories such as couples, rock nuts saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge.. 183 Material & labour for one light point/ fan point controlled by one , one way flame proof switch surface wiring complete with 2.5 sqmm single core multi stranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade drawn through ERW steel conduit heavy duty ISI marked of size 20 mm including dia accessories like tees, bends elbows, reducers bell mouth tube ends and fixing accessories such as couples, rock nuts saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge.. 184 Supply & fixing flame proof/weather proof 4 feet LED light fitting 2x18 WattCMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size etc complete all as specified and directed by Engineer-in-Charge. 185 Supply & fix flame proof/weather proof exhaust fan, 12 (300mm), single phase,with and including louvers complete CMRI certified recommended for gas group of IIA & IIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing complete all as specified and directed by Engineer-in-Charge.Note:-The rate quoated shall be in including making holes of suitable for exhaust fan of size 300 mm dia in PCC block masonry wall, making good the side of hole with CM (1:4)on wallwith two coat of paint match with existing wall and distributed surface with 4 nos of stainless steel fastner of suitable size to fit the exhaust fan no extra payment will be allowed to contractor on this regard 186 Supply & fix flame proof/weather proof rotary on/offswitch with termination box in LM6, 16A, 2 pole 250V complete all as specified and directed by Engineer-in-charge. 187 Supply & fix flame proof/weather proofswitch socket & plug combined in LM6, cable termnation box in LM6, 16A, 250V, 2P+earth complete all as specified and directed by Engineer-in-charge. 188 Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through and including conduit medium grade/new casing capping ISI marked with accessories and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge. (Note: Three runs of conductor for phase with one run of neutral and one run for earth wire and PVC conduit/casing capping will be measured & paid as one unit) 189 Supply & fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10 Amps, 240 v complete all as specified and directed by Engineer-in-Charge. 190 Supply & fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer-in-Charge. 191 Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 10 sqmm, 2.0 core complete all as specified and directed by Engineer-in-Charge. 192 Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge. 193 Supply & fix glavanised medium class pipe including fittings of dia 80 mm (3) diacomplete all as specified and directed by Engineer-in-charge. 194 Material & labour for cutting the existing GI/DIpipe of size 80 mm dia and taking 80 mm dia branch connection including necessary fittings etc complete all as specified and directed by Engineer-in-Charge. 195 Material & labour for precast cement concrete block masonry type 1:3:6 using 20mm graded stone aggregate with solid blocks, exc 10cm in width and setting in CM 1:4 complete all as specified and directed by Engineer-in-Charge. 196 Supply & fix TMT bars 10mm diaand over, cut to length,bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed)not less than 0.90mm dia complete all as specified and directed by Engineer-in-Charge. 197 Material & labour for precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc complete all as specified and directed by Engineer-in-Charge. (Reinforcement shall be measured and paid for separately). 198 Material & labour for preparing new plastered surfaces of walls and applying two Coats of acrylic washable distemper over a coat of chalk whitening complete all as specified and directed by Engineer-in-Charge. 199 Supply & fix anodised aluminium frame for doors, windows, ventilators and fixed partitions with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge 200 Supply & fix anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed by Engineer-in-Charge. 201 Material & labour for 4.00 mm thick sheet glass ordinary quality andglazing with oil putty in squareexc 0.50 Sqm in each pane complete all as specified and directed by Engineer-in-charge. 202 Material & labour for prelaminated particle board 9mm thick interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work fixed for cuboards/shelfs etc complete all as specified and directed by Engineer-in-charge. 203 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and as directed byEngineer-in-Charge. 204 Material & labour for PCC1:2:4, B2 ( using 40mm graded stone aggregate) infoundations filling and mass concrete complete all as specified and directed by Engineer-in-Charge. 205 Supply & fix mild steel pipe (tubular) fixed as vertical post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. 1161-1979 grade St.-240 as in posts complete all as specified and as directed byEngineer-in-Charge. 206 Supply & fix steel workas rafters and web in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. 1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge. 207 Supply & fix mild steel plates, plain or chequered, in Fe 410-W (Gde-E- 250) quality-A complete all as specified and directed by Engineer-in-Charge. 208 Supply & fix mild steel screw bolts 16 to 20 mm dia of neck (machine made) with hexagonal or square heads at one end and screwed theother, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long and n exc 10 cm longcomplete all as specified and directed by Engineer-in-Charge. 209 Supply & fix pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. 210 Supply & fix pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. 211 Material & labour for plain Cement concrete, type D2, (1:4:8), (using 40mm graded stone aggregate) in foundationand filling mass concrete complete all as specified and as directed byEngineer-in-Charge. 212 Material & labour for 50 mm thick cement concrete type B-1,1:2:4 mix (using 20 mm graded stone aggregates) as in copings includingnecessary use and waste of form work complete all as specified and directed by Engineer-in-Charge. 213 Material & labour for cement concrete (1:3:6) type C-2 (using 40 mm graded aggregate) as in bed to drain pipe and packing under and haunchingagainst the sides of pipes after they are laid and testedcomplete pipe sizeof 200mm bore complete all as specified and as directed byEngineer-in-Charge. 214 Material & labour for saltglazed stone ware drain pipe grade A ISI marked laidto slope in trenches, jointed in CM (1:2)and tested complete of size200mm diacomplete all as specified and directed by Engineer-in-Charge 215 Removing excavated material soil exc 250m but n exc 500m and depositing where directed at level n.exc 1.5m above starting point complete all as specified and directed by Engineer-in-Charge

Key Value

Document Fees
INR 500 /-
Tender Value
INR 37.30 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail