| 1 | M&L maintenance of DG Set of capacity 20 KVA to 30 KVAand carrying out \"B\" check after 250 hours run or 3 months period which ever is earlier including cost of replacement of new \"B\" check kit such as oil filter, bypass filter, airfilter, CR element and CR plates complete with \"O\" rings and draining of engine oil and filling up new engine oil,spares as required and calibration of ijectors and pumps including testing and painting of Body of DG set with its two coat of zinc oxide primer and one coat of synthetic enamel paint and match with its original colour complete all as specified and directed for the DG set of any make/type and various areas inside Pokaran under AGE (I) Pokaran. Notes :-(i) Engine oil will be measured and paid seperately(ii) Labour &Transportation shall deemed to be included in the unit rate quoted. Make of DG Sets to be Repaired:- Kirloskar/Cummin/Greaves Cotton/Mahindra |
| 2 | All as pet Item No. 01 above but for DG Set of capacity 63 KVA |
| 3 | All as pet Item No. 01 above but for DG Set of capacity 100 KVA To 160 KVA |
| 4 | M & L for dismantling the cylinder heads from diesel engine for calibration and repairs by replacing the spares such as Valves, Valve Guides, Valves seats and repairs kit and re-assembling to its original position with necessary Engine cylinder head gasket and O rings for DG Set of capacity 20 KVA to 30 KVA including testing complete all as specified and directed:- |
| 5 | All as pet Item No. 04 above but for DG Set of capacity 63 KVA |
| 6 | All as pet Item No. 04 above but for DG Set of capacity 100 KV to 160 KVA |
| 7 | M&L for disconnecting all electrical connections from the unserviceable self starter of any type /make /model, opening and dismantling of self starter suitable for the DG set of capacity 20 KVA to 30 KVA for carrying out repair, complete overhauling of the system including replacing the unserviceable parts such as bearing, carbon brushes, clutch plates etc assembling and refixing the self starter in its original position and connecting all connections and testing complete all as specified and directed.Note:- Armature coil and D coil field shall be measured seperatly under relevent items of schedule \"A\". |
| 8 | All as pet Item No. 07 above but for DG Set of capacity 63 KVA |
| 9 | All as pet Item No. 07 above but for DG Set of capacity 100 KVA To 160 KVA |
| 10 | S&F armature coil suitable for any make/type of DG set of capacity 20 KVA to 30 KVA 12 volts including testing and taking down old unserviceable armature coilfrom self starter for the DG set complete all as specified and directed:- |
| 11 | All as pet Item No. 10 above but for DG Set of capacity 63 KVA |
| 12 | All as pet Item No. 10 above but for DG Set of capacity 100 KVA To 160 KVA |
| 13 | M&L for removing the defective charging dynamo of capacity 24 V DC of any type / model / make of any capacity and opening it by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling and lubricating of the same replacing the armature and field coils reconnecting the same and refixing all items in original position testing and commissioning complete all as specified and directed. |
| 14 | All as per Item No. 13 above but for 12V DC Charging dynamo all as specified and directed by Engineer-in-Charge |
| 15 | M&L for disconnecting and dismantling of fuel pump assembly from its original position by opening of nuts and bolts, renewing of pump repair kit and fuel pipe refixing the same after overhauling including calibration and testing complete for the DG sets of capacity 20 KVA to 30 KVA all as specified and directed |
| 16 | All as pet Item No. 15 above but for DG Set of capacity 63 KVA |
| 17 | All as pet Item No. 15 above but for DG Set of capacity 100 KVA To 160 KVA |
| 18 | M&L for water pump complete, overhauling, replacing of gaskets, nuts, washers etc and reassembling the same and refixing the pump to the engine and testing including taking down the old unservicable water pump of any capacity of DG set from the engine and taking itto out side workshop, for the DG set of capacity 20 KVA to 30 KVA complete all as specified and directed:- |
| 19 | All as pet Item No. 18 above but for DG Set of capacity 63 KVA |
| 20 | All as pet Item No. 18 above but for DG Set of capacity 100 KVA To 160 KVA |
| 21 | M&L disconnecting the unservicable DC wiring from DG set of any type and rewiring the same with suitable new wire of existing guage by providing flexible pipe and testing completefor any type of DG set/make/size etc complete all as specified and directed. |
| 22 | M&L disconnecting the oil cooler of any DG set of capacity 20 KVA to 30 KVA any make and model from the existing location duly removing of all the mechanical and electrical connections and taking down the same for complete servicing, openingthe connected parts and cleaning thoroughly by using with suitable material and acid complete all as specified and directed |
| 23 | All as pet Item No. 22 above but for DG Set of capacity 63 KVA |
| 24 | All as pet Item No. 22 above but for DG Set of capacity 100 KVA To 160 KVA |
| 25 | M&L taking down defective Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from DG Set of capacity 100 KVA to 160 KVA, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the turbo charger assembly to its original position and reconnecting the same and including testing complete all as specified and directed. |
| 26 | Draining out fuel from fuel tank of DG set of capacity 20 KVA to 30 KVA any type and keeping it in separate container safely, disconnecting all the fuel lines and other electrical and mechanical connections and taking out the fuel tank for cleaning of tank both internally and externally for removing all the accumulated dusts or sediments, leak testing the tank, welding and brazing including one coat of synthetic enamel paint and refixing the tank to its original position, replacing the drain plug and PVC pipe protecting with flexible pipe, calibrating thefuel tank, refilling the drained out fuel back in to the tank and marking of litres in guage and provision of locking arrangement complete all as specified and directed |
| 27 | All as pet Item No. 26 above but for DG Set of capacity 63 KVA |
| 28 | All as pet Item No. 26 above but for DG Set of capacity 100 KVA To 160 KVA |
| 29 | Supply and filling engine oil of grade 20W/40 for DG sets complete all as specified and directed. Make: Castrol/Volvoline/SAE |
| 30 | Supply and topping up of Acid Mixture suitable for Lead Acid Batteries of capacity 12V / 24V Complete all as specified and as directed. |
| 31 | Supply and filling of distilled water suitable for Lead Acid Batteries of capacity 12V / 24V Complete all as specified and as directed. |
| 32 | S&F Automatic Voltage Regulator (AVR) suitable to DG set of capacity 20 KVA to 30 KVA including disconnecting of all electrical connections of existing unserviceable automatic voltage regulator of any size/make complete all as specified and directed. |
| 33 | All as pet Item No. 32 above but for DG Set of capacity 63 KVA |
| 34 | All as pet Item No. 32 above but for DG Set of capacity 100 KVA To 160 KVA |
| 35 | M&L attending complaints for any type of DG set of emergency basis to clear/rectify both electrical and mechanical faults of DG set installed at various locations under AGE(I) Pokaran Complete all as specified and directed. |
| 36 | S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set of 100 KVA to 160 KVA capacity with alllisted parameters including testing complete all as specified and as directed. |
| 37 | S&F in replacement of Rectifiers of existing Make to DG Set of 100 KVA to 160 KVA capacity with all listed parameters including testing complete all as specified and directed. |
| 38 | S&F 12V, 180 AH maintenance free battery suitable for DG set complete all as specified and directed.Make:- AMARON/EXIDE/EXPRESS/CANON |
| 39 | S&F heavy duty battery cable lead of copper conductor with copper lugs terminal for the 12V 180 AH maintenance free battery suitable for DG set complete all as specified and directed. |
| 40 | S&F battery brass terminal and jelly complete all as specified and directed. |
| 41 | M&L taking down the old unservicable Radiator assembly by unscrewing all mechanical and electrical connections from the existing mounting anddisconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of the radiator and cleaning throughly the chocked pipes of the radiator by using detergent like castic soda, cotton watse etc.and refixing the same to its original position with suitable sizeof nuts and bolts, washers etccomplete all as specified and directed for DG Set of capacity 20 KVA to 30 KVA |
| 42 | All as pet Item No. 41 above but for DG Set of capacity 63 KVA |
| 43 | All as pet Item No. 41 above but for DG Set of capacity 100 KVA To 160 KVA |
| 44 | S&F in replacement of microprocessor based control unit suitable to DG set of 100 KVA to 160 KVA capacity with all listed parameters including testing complete all as specified and directed. |
| 45 | S&F in replacement of \"V\" Belts for any capacity/make of DG Set complete all as specified and directed. |
| 46 | S&F in replacement of Fan Belts for any capacity/make of DG Set complete all as specified and directed. |
| 47 | S&F in replacement of Dinamo Belts for any capacity/make of DG Set complete all as specified and directed. |
| 48 | Supply and filling coolant (DFC 50%) for DG sets complete all as specified and directed. |
| 49 | S & F in repairs air cleaning element inner and outer with necessary \"O\" ring for the DG setof capacity 20 KVA to 30 KVA as that of existing make and model complete all as directed. |
| 50 | All as pet Item No. 49 above but for DG Set of capacity 63 KVA |
| 51 | All as pet Item No. 49 above but for DG Set of capacity 100 KVA To 160 KVA |
| 52 | Supply & fix and test run the Fly wheel Ring of existing model size suitable for DG set of any capacity including taking down old unserviceable fly wheel ring complete all as directed. |
| 53 | S&F 12V, 80 AH maintenance free battery suitable for DG set complete all as specified and directed.Make:- AMARON / EXIDE / EXPRESS / CANON |
| 54 | Supply and fix 4 Sqmm 2 core, 240 Volts Aluminium solid conductor cable heavy duty PVC insulated ISI marked all as specified and directed by Engr In charge. |
| 55 | M&L for repair to LED street light fitting 35/45 Watt incl replacement of unsv items like driver, module, controller any size of watt, and taking down LED street light, nut bolt, clamp and refixing after reapir on same pole etc as per direction of Engr in Charge |
| 56 | M&L for repair to LED street light fitting 60/90 Watt incl replacement of unsv items like driver, module, controller any size of watt, and taking down LED street light, nut bolt, clamp and refixing after reapir on same pole etc as per direction of Engr in Charge |
| 57 | S & F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete |
| 58 | All as per Item No. 57 above but for LED Street light of capacity 90 Watt all as specified and directed by Engineer-in-Charge |
| 59 | All as per Item No. 57 above but for LED Street light of capacity 60 Watt all as specified and directed by Engineer-in-Charge |
| 60 | M&L for cleaning down complete body including fitting and fixture of desert cooler of air flowing capacity 4000/5000 Cum/per hour of any make with wire including removal of all sludges, loose paints, dust, dirt etc and prepared the surface clean for painting and applying two coats of rubber based paint inside the water tank complete, including rewriting of MES No. complete all as specified & directed by Engr-in -charge. |
| 61 | S&F fan motor of single phase 230 Volt, 1400 RPM 3 speed 1/8 HP, 20\" sweep for desert cooler incl cast iron rings for motor with clamps nuts & bolts complete all as specified & directed by Engr-in -charge. |
| 62 | All as per Item No. 61 above but fan motor 24\" sweep 900RPM |
| 63 | S&F PVC flexible pipe of 16 mm outer dia complete with PVC elbow, tee as required complete all as specified & directed by Engr-in -charge. |
| 64 | S&F desert cooler selector switches three way 230 Volts single phase of standared quality fixed in desert cooler all as specified & directed by Engr-in -charge. |
| 65 | S&F repair, wood wool pad (set of three) minimum weight 0.8 Kg, proper fixed in 3 side of panels of desert cooler complete all as specified & directed by Engr-in -charge. |
| 66 | S&F in repair, plug top 3 pin 5 Amp with cable upto 2mtr, 230 Volt (ISI marked) complete all as specifide & directed by Engr-in -charge. |
| 67 | S&F in repair, PVC insulated and PVC sheathed round flexible three core copper conductor cable of size 40/0.0076 Sqmm including making necessary connections for desert coolers complete all as specifide & directed by Engr-in -charge. |
| 68 | S&F capacitor 4 Mfd for fan motor of desert cooler complete all as specified & directed by Engr-in -charge. |
| 69 | Supply and replace water spray pump 1/30 HP for desert cooler. |
| 70 | S&F PVC fan blade for fan motor of desert cooler of 20 inch sweep complete all as specified & directed by Engr-in -charge. |
| 71 | M & L for opening of voltage stabilizer, repairing/ rewinding of transformer including heating varnishing and replacing of relay of the 5 KVA capacity complete all as specified and directed. |
| 72 | M & L for opening of voltage stabilizer, repairing/ rewinding of transformer including heating varnishing and replacing of relay of the 2 KVA capacity complete all as specified and directed. |
| 73 | Taking out old unserviceablevolt meter/ amp meter and Supply & fixvolt meter/ amp meterfor single phase voltage stabilizer of all capacity (1KVA/2KVA/5KVA) all as specified and directed. |
| 74 | M&L maintenance for RO Plant of capacity 25 Ltrs for checking all tubings, gaskets, fittings and solenoids for leaks and wear, clean all external surfaces etc all as per directed by Engg-in-charge. |
| 75 | S&F in repair micron fliters as per directed by Engg-in charge |
| 76 | S&F in reapir high pressure pump as per directed by Engg-in charge |
| 77 | S&F in repair PH sensor as per directed by Engg-in charge |
| 78 | S&F in repair conductivity sensor as per directed by Engg-in charge |
| 79 | S&F in repair ORP sensor as per directed by Engg-in charge |
| 80 | S&F in reapir membrane change as per directed by Engg-in charge |
| 81 | S&F in reapir temperature transmitter as per directed by Engg-in charge |