| 1 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. |
| 2 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-Charge.1:4:8 or leaner - Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). |
| 3 | Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground and stacking of serviceable material within 50 metre lead as per direction of Engineer-in- Charge. |
| 4 | Earth work in surfaceexcavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m lead and lift up to 1.5 m, disposed soil to be levelled and neatly dressed, All kinds of soil |
| 5 | Structural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 6 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia. 3mm including strengthening with 2mm dia. wire or nuts, bolts and washers as required complete, with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand : 10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x 50cm of the same mix, as per the direction of Engineer-in-Charge. (cost of post painting earth work & C.C. to be paid separately) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for : Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. |
| 8 | Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand) including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5mm) including making drainage opening wherever required etc. complete as per direction of Engineer-in- charge. (Length of finished kerb edging shall be measured for payment). (Old kerb stones shall be supplied by the department free of cost). |
| 9 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc. of required colour strength, thickness pattern, surface texture (smooth/rough) and size/ shape, conforming to 15658 2006 made by table vibratory method using PU mould, laid in required colour and pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including locking with M15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer\"s specifications and direction of Engineer-in- Charge.60 mm thick C.C. paver block of M-30 grade |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level :With 40mm nominal size graded stone aggregate. M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level :With 20mm nominal size graded stone aggregate.M-20 – Grade concrete |
| 12 | Synthetic enamel paint over a under coat: - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 13 | Providing and fixing of 3 seater stone bench made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1500mm, width 600mm, legs height 500 mm, back support height 500mm. |
| 14 | Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work. |
| 15 | Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) |