| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-11-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 15-11-2025 |
| Sl. No. | Item Description |
| 1 | Supplying, laying, jointing & testing, in replacementof 1100 volts grade, heavy duty, LT XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed,3.5 Core, 185 Sqmm nominal cross section in service connections laid in loops /ducts, along wall /pole orunder floor /roador laid in trenches including taking out old unserviceable cable complete all as specified and directed. |
| 2 | All as per ser item No. 1 here-in-beforebut120 Sqmm 3.5 Core. |
| 3 | All as per ser item No. 1 here-in-beforebut95 Sqmm 3.5 Core. |
| 4 | Supplying, laying, jointing & testing in replacementof 11000 volts grade, heavy duty, HT XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, 3 Core, 95 Sqmm nominal cross-section in service laid in loops /ducts, along wall /pole orunder floor /roador laid in trenches connections including taking out old unserviceable cable complete all as specified and as directed. |
| 5 | Supply and spread dry sand for cable cushioning in trenches all as specified in clause 19.75 of SSR Part-I complete all as specified and as directed by Engineer-in-Charge. |
| 6 | M&L for brick, subclass \"B\" well burnt, laid dry flatin trenches for protection of cable with a maximum gap of 10 mm between two consecutive brick over LT cable including taking out old unserviceable bricks, complete all as specified and as directed by Engr-in-charge. |
| 7 | Excavation in trenches not exceeding 1.5 min deep & not exceeding 1.5 mwideand getting out in soft / loose soil including leveling and ramming complete all as specified and as directed. |
| 8 | Returning, refilling in trenches exvcavated soils, including spreading leveling & well ramming in layers not exceeding 25 cmthick complete all as specified and directed. |
| 9 | Removal of excavated surplus soil to a distance n.exceeding50 m and depositing where directed at a level not exceeding1.5 metre above the starting point complete all as specified and directed. |
| 10 | M&L for 40 mm bore GI pipe (light grade) in replacement with all fittings laid in trenches or walls complete for UG cable protectionwhen crossing the road of size 40 mm bore complete all as specified and directed. |
| 11 | M&L for 50 mm bore GI pipe (light grade) in replacementwith all fittings laid in trenches or wall complete for UG cable protectionwhen crossing the road of size complete all as specified and directed. |
| 12 | M&L for 80 mm bore GI pipe (light grade)in eplacement with all fittings laid in trenches/wall complete for UG cableprotection when crossing the road of size complete all as specified and directed. |
| 13 | M&L for Servicing /Caliberation / Repairs toAir Circuit Breaker upto 630 Amps by OEM of ACB only for EDO ( Electrically Draw Out) type/ MDO type(Mannually Draw out type)/ Fixed type. Taking out any type of ACBfor servicing / repair and checking / caliberation ofmicroprocessor release,Earth fault protection of 4 pole, 50 KA breaking capacity 415 volts with all draw out type mechanism, advanced self powered electronic protection units, neutral overload protection, automatic earth fault relay / over current relay , automatic safety shutter, inbuilt temperature protection, icu=ics=icw(1s)=50 KAfixed in panel complete including relay wiring checking ,LT UG cable connection with main incoming ACB complete connection for its healthy functioningall as directed. Note- Certificate of Servicing /Caliberation will be provided by the contractor free of cost. |
| 14 | S&F ofLED flood light with pressure die cast aluminium housing 150 Watt completed with connectionincluding taking down old unserviceable light complete all as specified and directed. |
| 15 | S&F of LED flood light with pressure die cast aluminium housing 200 Watt completed with connectionincluding taking down old unserviceable light complete all as specified and directed. |
| 16 | Supply and fixing in LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down old HPSV light fitting 70/150/250 watt complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for boring of holes by manually / machine under road, pavement, hard standing by \"trenchless technology for laying of 40/50/80 mm GI pipe for cable laying, complete all as specified and directed by Engr in charge. Note: GI pipe will be measured and paid seperately under respective item. |
| 18 | S&F in repairs cable jointing kit for 11 KV (earthed) grade cable, for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of 95 Sqmm complete all as specified and directed. |
| 19 | S&Fin repair Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed. |
| 20 | S&Fin repair Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed. |
| 21 | S&F in replacement busbar chambersthree phase forur wire system rated current400 Amps with suitable busbar thickness IP41, 415 volts, complete all as specified and directed. |
| 22 | S&F in replacement busbar chambers three phase forur wire system rated current630 Amps with suitable busbar thickness IP41, 415 volts, complete all as specified and directed. |
| 23 | S&F in repair on load change over switch including enclosure, 1000 Amp, 4 polewith advance neutral including making cable connection to the change over switch, fixing on wall/ floor with mild steel fastener, nut/bolts complete all as specified and directed. |
| 24 | S&F in repair on load change over switch including enclosure, 630 Amp, 4 polewith advance neutral including making cable connection to the change over switch, fixing on wall/ floor with mild steel fastener, nut/bolts complete all as specified and directed. |
| 25 | S&F in repair on load change over switch including enclosure, 400 Amp, 4 polewith advance neutral including making cable connection to the change over switch, fixing on wall/ floor with mild steel fastener, nut/bolts complete all as specified and directed. |
| 26 | Supply & fix cable jointing kit for 1.1 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3.5 Core XLPE armoured aluminium conductor cable of 120 Sqmm complete all as specified and directed. |
| 27 | Supply & fix cable jointing kit for 1.1 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3.5 Core XLPE armoured aluminium conductor cable of 95 Sqmm complete all as specified and directed. |
| 28 | Supply & fix cable jointing kit for 1.1 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3.5 Core XLPE armoured aluminium conductor cable of 70 Sqmm complete all as specified and directed. |
| 29 | S&F in repair Copper lugs, E-blot size 10.5 mm, suitable for 25 sqmm 3.5 core to 120 sqmm 3 core cable including crimping/ connecting with UG cable and panel board complete all as specified and directed. |
| 30 | M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32x6mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 40 mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanised Iron/steel . supplying and laying charcoal stone aggregate) chamber and RCC cover of size54x54x50 mm (1:2:4) type B1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia TMT bars @75mm C/C both ways with mild steel handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in drawingNote - Cost of GI stripand GI protection pipe up to a distance 7.5 M shall be includedin quated rate of above Items complete all as specified and directed. |
| 31 | M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire of 4mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe medium grade 15 mm bore for protection of GIwire from earth electrodeto test point /machinery / equipment.supplying and laying charcoal dustcomman saltPCC(1:2:4) type B1 using 20 mm gradedstone agregratechamber andRCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1using 20 mm stone agrigrtae )reinforced with 8 mm dia TMT bars @75mm C/C both ways with mild steel handle 12 mm dia,using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No-3 of SSR part-1including testing and taking out the old one complete all as specified and directedNote - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be includedin quated rate of above Items. |
| 32 | S&F MCCB TPN 63 Amp 415 Volts, 50 Hz suitable for existing and connectionwith copper lugs including taking down old one complete all as specified and directed. |
| 33 | S&F MCB TPN 63 Amp,C curve, 415 Volts, 50 Hz suitable for existing and connectionwith copper lugs including taking down old one complete all as specified and directed. |
| 34 | S&F MCB TPN 32 Amp,C curve, 415 Volts, 50 Hz suitable for existing and connectionwith copper lugs including taking down old one complete all as specified and directed. |
| 35 | S&F MCB SPN 32 Amp,C curve, 415 Volts, 50 Hz suitable for existing and connectionwith copper lugs including taking down old one complete all as specified and directed. |
| 36 | Supply ,installation, testing and commissioningof canopy headed HT 11K volt grade, 3 phase, , AC, 50 cycle, feeder piller box size 1200x1000x1000 mm,factory made outdoor pedestal type double door, fabricated out of 3.15 mm thick CRCAsheet with powder coatedpaintingin side and outside of approved shade ,locking arrangementwith duplicate keys two earthy terminal suitable cable gland for all incoming and outgoing cable grouting of feeder pillar box 15 cm above ground level by providing 90 cm long angle iron of size 50x50x6 mm welded on all the four comers embedded in PCC (1:2:4) using 20 mm graded stone agg upto 30 CM deep and 45 CM above from normal ground levelcomplete all as specified and directedincl the following components:-(a) The panel will be havingcopper bus bar of size 400×40×6 mm03 strips with porcelain HT long post insulator Note - HT Feeder Piller will be from CPRI Approved firm. |
| 37 | M & L for filtration/dehydration transformer oil of transformer capacity 50 KVA to 800 KVA indoor/outdoor type, pole mounted / plinth mounted in situ till achieve dielectric strength min 40 KV at 4mm gap complete all as specified and as directed. |
| 38 | M & L for topping up/replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade including necessary dehydration to achieve dielectric strength min 40 KV at 4mm gap complete all as specified and as directed. Note:- (a) New transformer oil to be bought in company sealed ISI marked container with or original test certificate(b)Filtration /dehydration of transformer oil shall be carried out at the location where transformer is installed and necessary filter/dehydration plant having pressure gauge, hour meter, temperature gauge to be brought at site by contractor (c) During process of filtration of oil, transformer shall be on load. |
| 39 | M&L for silica gel grain in the breather assembly of transformer complete all as specified and directed |
| 40 | M&L for LT bush insulator complete with outer bushing studs made out of brass including oil seal ,gaskets as per existing sample for three indoor/outdoor type transformer of cap for upto 800 KVA (set of four) includingtaking out the old complete all as specified and directed. |
| 41 | M&L for HT bush insulator complete with outer bushing stud, made out of brass including oil seal ,gasketsas per existing size for indoor/outdoor transformer of cap for upto 800 KVA for 11K / 440 Volts includingtaking out the old all as specified and directed (Set of three) |
| 42 | Supply and Fixing Packing gasket for top cover and terminal box for HT and LT side as per existing sample for out door/indoor type transformer including nuts, bolts and washer etc all as specified for upto 800 KVA transformer (after draining out transformer oil and refilled to the same transformer).Cost of minor spares i.e. nut bolt andwasher if required to complete the job is deemedto be included in quoted rates complete all as specified and directed. |
| 43 | M&L for triming/cutting of tree branches up to height 12.00 m to 15.00 m in electric HT/OH lines with both side 3.00 mdistance from outer conductor and including surface dressing and removing the material at a distance not exceeding 500.00 mtr complete all as specified and as directed. |
| 44 | Material and labour for cutting bushes, grass throny, small plants/ trees up to height 5m in and around the E/M installation and electricFPB and including surface dressing and removing the material outside Defence land complete all as specified and directed. |
| 45 | Maintenance and overhauling of DG set of capacity 400/500 KVA on every month including checking, cleaning, adjusting/tightening, oiling, greasing and reseting of existing part decarbonising of battery terminals of DG set at different location of installation and keep ready to set for proper functioning of valve \"V\" belts pulleys, fan hub, idler, water pump, fiters engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbons brushes vibration dampers, springs, AVRs exhause pipes etc. Note : Spares part will be measured and paid separetely under respective item of BOQ/ Sch \"A\". |
| 46 | Disconnecting connection of radiator and taking down for servicing and cleaning and refixing complete all as specified and directed. |
| 47 | Supply only Air Filter suitable for 400/500 KVA DG Set complete all as specified and directed. |
| 48 | Supply only Oil Filter suitable for 400/500 KVA DG Set complete all as specified and directed. |
| 49 | Supply only diesel filter suitable for 400/500 KVA DG Set complete all as specified and directed. |
| 50 | Supply only Water separator suitable for 400/500 KVA DG complete all as specified and directed. |
| 51 | Supply only Coolant complete all as specified and directed. |
| 52 | Supply only Engine oil as per OEM specifications complete all as specified and directed. |
| 53 | Labour required for re-stretching/ restringing of existing loosed / sagged ACSR over head conductor ofany type and size including supply and binding wire/aluminum tape of required size, opening from insulators as fixed on pole after taking proper electric shut down from concerned staff including taking down unserviceable conductor from OH line and proper binding with additional conductor and restringing on line, complete all as directed by Engineer-in charge. |
| 54 | Supply only Discharge Rod suitable for HT line 11KV with 10 Sqmm single core copper cable complete all as specified and directed. |
| 55 | Supply and filling Dry chemical powder refill suitable for existing 4Kgs ,ABC type portable fire extinguiser incl removing old one all as specified and directed. |
| 56 | S&F in repairs lightening arrestor HT,11 KV,10 KA expulsion type complete with all fittings,transmission class complete all as specified and as directed. |
| 57 | S & F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green \"Two-in-series\" assembly for tension with tension clamps for conductors, working pressure 11000 volts including taking down old unserviceable insulator complete all as specified and as directed. |
| 58 | M&L for painting of transformer outer surface with one coat of synthetic enamel paintfor transformer capacity 50-250KVA after preparation of old painted surface using sprayer complete all as specified and directed. Note:-(i) During process of painting transformer will be under shut down for the period and the rate deemed to be included for running the sprayer machine with own arrangement by the contractor (ii) After completion of painting HT/LT bushing, oil inspection glass and name plate to be made clean using volatile cleaner, complete all as specified and directed. |
| 59 | All as per item No 58.00 above but capacity of transformer 250-800 KVA. |
| 60 | M&L air break switch gang operated device HT 11 KV triple pole outdoor type with 12 insulator 200 Amps rating with drop out fuse assembly with fuse carrier and the fuse element mounted on insulator and steel frame mechanically operated with operating mechanism consisting of operating rod of 25mm bore light grade GI pipe of suitable length operative from ground level and with locking arrangement with MS flat iron clamp 50 x 6 mm including MS channel of suitable size and length to fixing GOD including nuts, bolts and washers all as specified and as directed. |
| 61 | S&F pin type insulator, porcelain vitreous white, brown or green insulator including one galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut 100mm height 65 mm dia for working pressure 1100 volts including dismantling old unserviceable insulator complete all as specified and as directed. |
| 62 | M&L aluminum conductor steel reinforced (ACSR) including copper binding wire complete all as specified and as directed. |
| 63 | S&F PVC type over head line spacer for up to fourconductor, suitable for 1100 volt grade intended to avoid short circuiting during sagging/storm etc including taking out the old all as directed. |
| 64 | Supply & fixing/crimping in replacement of old/overheated jumpers/service connection with Bimetallic PG Clamp of aluminum alloy with GI nut & bolt and conducting jelly, suitable for weasel / Mink or any other ACSR Conductor including taking out the old complete all as specified and required at site or as directed by Engr in Charge. |
| 65 | M&L for Cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed. |
| 66 | Supply and erecting in true vertical position steel tubular swaged poles type 410 SP-22 (8.5 meter long) complete with CI base plate pole cap,finial taper plug,bolts, nuts, washersetc including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Note: (i)The portion above coping shall be painted in alternative bands ofcolours starting with blue colour (each band of 30 Cm wide) by two coats of Synthetic enamel paint upto 1.5 meter height and the cost of same shall be deemed to be included in the rate quoted.(ii) The pole numbers etc shall be enumerated on the poles and the cost of writing letters with synthetic enamel paint shall be deemed to be included in the rate quoted.(iii) PCC and and exavation shall be measured and paid seperately.(iv)The rates alsoincludedrilling of holesinsteel tubular poles for continuous G.I. earth wire etc. to the required size and number. |
| 67 | S & F steel tubular swaged pole complete with cast iron base platefinial taper plug,bolts,nuts,and screw as specified type SP-55 (11.0 metres long)including fixing of cross arms ,insulators and all electrical cables/ACSR conductors/earthwires andpainting with two coats of aluminium paints over a coat of red oxide primer of pole as per sample including taking out the old one complete all as specifies and directed.Note: (i)The portion above coping shall be painted in alternative bands ofcolours starting with blue colour (each band of 30 Cm wide) by two coats of Synthetic enamel paint upto 1.5 meter height and the cost of same shall be deemed to be included in the rate quoted.(ii) The pole numbers etc shall be enumerated on the poles and the cost of writing letters with synthetic enamel paint shall be deemed to be included in the rate quoted.(iii) PCC and and exavation shall be measured and paid seperately.(iv)The rates alsoincludedrilling of holesinsteel tubular poles for continuous G.I. earth wire etc. to the required size and number. |
| 68 | M&L for PCC 1:2:4 type B1 using 20 mm graded agregrate as in foundation for coping in foundation of pole including necessary form work complete all as specifies and directed. |
| 69 | M&L for PCC 1:3:6 type C2 using 40 mm graded agregrate as in foundation in mass concreting of pole including necessary form work complete all as specifies and directed. |
| 70 | Disconnecting & taking out non functional VCB of circuit current 30 Amps and busbar current 400 Amps, 50 Hz, Panel Type : UN1 VAC for 11 KV Make : Crompton Greavesor any other existing make dismantling / opening of the VCB for servicing / overhauling, taking out and removing unserviceable /defective parts includingcleaning & servicing ,greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and its testing complete all as specified and directed by Engineer-in-Charge. Notes :- (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall be measured and paid for separately. |
| 71 | Supply of Tripping Coil 24 / 110V DC Suitable for VCB 11000. Volt. of 400 Amp, 3.5 MVA complete all as specified and as directed. |
| 72 | Supply of Closing Coil 24 / 110V DC Suitable for VCB 11000. Volt. of 400 Amp, 3.5 MVA complete all as specified and as directed. |
| 73 | Supply of Segment Gear Suitable for VCB 11000. Volt. of 400 Amp, 3.5 MVA complete all as specified and as directed. |
| 74 | Supply of Spring Charging Motor 220V. Suitable for VCB 11000. Volt. of 400 Amp, 3.5 MVA complete all as specified and as directed. |
| 75 | Supply of TrippingLatch / SaftSuitable for VCB 11000 Volt. of 400 Amp., 3.5 MVA complete all as specified and as directed. |
| 76 | Supply of ClosingLatch / Lever Suitable for VCB 11000 Volt.of 400 Amp, 3.5 MVA complete all as specified and as directed. |
| 77 | Supply of TNC Switch Suitable for VCB 11000 Volt. of 400 Amp, 3.5 MVA complete all as specified and as directed. |
| 78 | Supply of Auxiliary Switch 6 No-6NC Suitable for VCB 11000 Volt. of 400 Amp., 3.5 MVA complete all as specified and as directed. |
| 79 | Supply ofPanel Spout Set, 11 KV Suitable for VCB 11000 Volt., of 400 Amp. 3.5 MVA complete all as specified and as directed. |
| 80 | Supplyof Jaw Contact Suitable for VCB 11000. Volt. of 400 Amp, 3.5 MVA complete all as specified and as directed. |
| 81 | Supply of Insulator Type - Resin Cast Epoxy, Size - 61mm/130mm 11kVSuitable for VCB 11000. Volt. of 630 Amp, 3.5 MVA complete all as specified and as directed. |
| 82 | Supply of Vacuum Intrepter 11kVSuitable for VCB 11000. Volt. of 400 Amp, 3.5 MVA complete all as specified and as directed. |
| 83 | Supply of Current Transformer (C.T) Resin Cast Epoxy, 11kV Suitable for VCB 11000 Volt. of 400 Amp., 3.5 MVA complete all as specified and as directed. |
| 84 | Supply of Potential Transformer (P.T), Dry Type Resin Cast Epoxy, 11kV Suitable for VCB 11000 Volt. of400 Amp., 3.5 MVA complete all as specified and as directed. |
| 85 | Supply of LED Indication Lamp 240V. DC Red, Green and White, 11kVSuitable for VCB 11000. Volt. of 400 Amp, 3.5 MVA complete all as specified and as directed. |
| 86 | Supply of LED Indication Lamp 220V. DC Blue, 11kVSuitable for VCB 11000. Volt. of 400 Amp, 3.5 MVA complete all as specified and as directed. |
| 87 | Supply of Protection 3 Phase Over Current + Earth Fault Relay, 11kV Suitable for VCB 11000 Volt. of400 Amp., 3.5 MVA complete all as specified and as directed. |
| 88 | Supply and fixing in replacement of DO fuse outdoor type upto ratio 200 Amps 11 KV incl taking down old one complete all as specified and as directed. |
| 89 | Material and labour for 40 to 63 mm grade stone aggregate of black trap/granite/basalts spread in layers not exceeding 25 cm thick& well rammed incl removal of old stone aggrigate complete all as specified and as directed. |
| 90 | Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof eiling including connecting up with existing light point with three core flexible copper conductor cable of suitable size including taking down oldfitting 20 Wattcomplete all as specified and directed by Engr-in-Charge. |
| 91 | S & F LED light fitting 9W/10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old bulk head fitting complete all as specified and directed by Engr-in-Charge. |
| 92 | Taking down old unserviceable Automatic voltage regulator from DG Set and supply, fixing including testing of new Automatic voltage regulator suitable DG Sets of capacity 500 KVA complete all as specified and directed. |
| 93 | S&F flexible rubber coupling of engine and alternater with bolts and nuts etc of suitable size complete all as specified and directed for 500 KVA Capacity |
| 94 | Taking out FIP from DG set and transporting up to nearest workshop for calibration including calibration of FIP from auth workshop, transporting back, refixing the same in DG Set including testing for smoth functioning complete all as specified and directed for the 500 KVA Capacity |
| 95 | Material and labour for point wiring, using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single core in green colouras earth wireconnected to earth dolly including taking down the old point wiring complete all as specified and directed. |
| 96 | Supply and fixingin repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down old HPSV light fitting 70/150/250 watt complete all as specified and directed by Engr-in-Charge. |
| 97 | M & L for dismantling and removing of fuel tanks MS any size/ type by disconnecting of fuel pipes connection, draining out of oil from the tank, cleaning and removing sediments, dirts etc from fuel tank including repairing offuel gauge dial type by replacing unserviceable parts etc complete for 500 KVA Capacity DG Sets all as specified and directed. |
| 98 | M&L for dismantling existing unserviceable self starter motor in repairing of 500 KVA capacity DG Set, including S&F new self starter motor 12V/24 DC of same capacity/ model/ type connecting up and testingall as specified and directed. |
| 99 | Taking out old unserviciable battery from DG Set including supply, fixing and testing of maint free battary 12 Volts 180 AH complete all as specified and directed. |
| 100 | Supply only hand gloves HT for operating / handling sub station upto 11 KV ISI Marked complete all as directed. |
| 101 | Taking proper shutdown , disconnecting the LT and HT electric mains from transformer of any capacity, removing the transfomer from pole/structure/ platform and shifting to authorised workshop after draining out the transformer oil at site, dismantling and disconnecting damaged HT/LT coil to facilate necessary repairs, rewinding/reconditioning reassembling the tranformer, bringing back to the site, taking out dehydrated old trasformer oil and connecting with existing electrical system of HT and LT including testing complete all as specified and directed. Note :- Winding wire, transformer oil etc shall be measured and paid separately |
| 102 | Rewinding of LT/HT coils of any size and type of transformer including cleaning the brunt out insulating materials, brazing and rewinding with appropriate turns and size of super enamelled DPC insulated copper winding wire of appropriate gauge including filling insulation paper etc complete all as specified and directed Note :-(i) Gauge of binding wire shall be approved by Engr-in-Charge.(i) Weight, number of turns, gauge, insulation of winding wire shall be as per OEM.(ii) Work of rewinding shall be carried out through OEM or their authorised vendor only. |
| 103 | Supply only HV Bushingsuitable for 250-800 KVA transformer including connection complete all as directed. |
| 104 | Supply only silica gel in the transformer breather assy including taking out UNSV silicagelcomplete all as directed. |
| 105 | Supply only LV Bushingsuitable for 250-800 KVA transformer including connection complete all as directed. |
| 106 | Supply only copper terminal stud , both end threaded complete with double nuts and washers with heat resistant gasket suitable for 250-800KVA transformer LV side 415 volts including connection complete all as directed. |
| 107 | Supply only Electrical insulation HT tape of 3/4\"width of 30 feet length Etylene Propylene backing highly comfortable to wrap snugly over most any shape streches up 100 percent to provide avoid moisture, resistant insulation tape complete all as specified and directed. |
| 108 | M&L for CRC 2-26 Electrical equipment (contact) cleaner spray used to prevent electronic malfunction equipment caused by water penetration, humidity, corrosion etc and of 500ml can complete all as specified and directed. |
| 109 | Supply & Laying synthetic insulating mat of size 2m x 1m x 25mm thick for voltage upto 11 KV complete all as specified and as directed. |
| 110 | Calibration ofrelay of 11KV HT VCBsand 1.1KV ACBs installed at varioussub stn at ADRDE area complete all as specified and directed.Note:-1. All testing & calibration equipment with all accessories shall be brought by the contractor and rate for same is deemed to be included in quated rates.2. The complete test report shall be submitted by the contractor to Engr-in-charge/ GE(I)R&D Delhi |
| 111 | Supplying, laying, jointing & testing, in replacementof 1100 volts grade, heavy duty, LT XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed,3.5 Core, 25 Sqmm nominal cross section in service connections laid in loops /ducts, along wall /pole orunder floor /roador laid in trenches including taking out old unserviceable cable complete all as specified and as directed. |
| 112 | All as per ser item No. 95.00 here-in-beforebut16 Sqmm 4 Core. |
| 113 | All as per ser item No. 95.00 here-in-beforebut10 Sqmm 2 Core. |
| 114 | Dismantling and taking down unserviceable street light / security light fitting/hanger light(highbay type) of 30/45/48/60/70/90/120 watt from existing Bldgor Street light pole after disconnecting all electrical connections for repair or replacement of unserviceable parts and re-fixingthe same after making it serviceable and including all electrical connections complete all as specified and directed. |
| 115 | Dismantling and taking down unserviceable High mast lantern complete set ( 9 Nos x 180 watt / 8 Nos x 180 watt ) from high mast pole after disconnection all electrical connections and refixing the same after making it serviceable including all electrical connections complete all as specified and directed. |
| 116 | S&F in repair New generation energy saving and environmental friendly long life LED street light fitting 60 Watt,made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. All as specified and directed by Engr-in-Charge. |
| 117 | S&F in repairs LED Energy saving, environment friendly, long life, exclusive innovative die-cast aluminium flood light 180 Watt, with highly efficient LEDs as light source, suitable for highlighting architectural features or retail spaces. comlete all as specified.and directed by Engr-in-Charge |
| 118 | M&L for Wiring for circuit/submain wiring 2 run of 2.5 sqmm, FRLS PVC insulated single core, copper conductor for phase and neutral and 1 run of same size of copper conductor for earth wire,in PVC Conduit of size 25 mm dia including fixing clamp, nuts, bolts, screw etc and connecting up with street light/ security light/ junction box, including dismantling/ taking down of old unserviciable wiring circuit from existing Pole, complete all as specified and directed by Engr- in-Charge.Note : Two run of 2.5 sqmm and one run of 2.5sqmm earth wire with one run of25 mmPVC conduit will be measured as on run. |
| 119 | Labour work for disconnecting the all electrical connections from street light junction box/timer panel and taking out the loop ofXLPE UG cable of any size and connecting to the street light junction box/ timer panel after cutting the faulty/burnend out end and opening of UG cable loop complete all as specifed and directed.Note:-1.Taking out the old brick and relaying the same after opening of loop shall be included in quoted rate.2.Exavation work as required for LT cable ( Depth upto than .5 Mfrom GL and width not less than .4 M) shall be included in the quoted rate.3.Sand as requiredwill be measured and paid seperately.4.Material required for electrical connections such as lugs,cable gland ,PVC tape etc shall be included in the quoted rate. |
| 120 | M & L forold painted surfaces of LT/HT Steel tubular polesof any size shape and height complete andapplying synthetic enamel paint of 200 mm widthwith alternate block ofwhite /black upto 5 feet height from ground level including writing the pole No with black enameled paint of size 70 mmwideand 100 mm height, and applying two coatsof alluminiumpaint on the balance portion of pole after necessary preparation of surfaces and cleaning the vegetation approximately 4 square meter around the pole including following works complete all as specified and directed by Engineer-in-Charge. |
| 121 | (a)Cross arms (each pole 2 Nos). |
| 122 | (b) 45/50 mm dia bracket (each pole 1 Nos) including clamps |
| 123 | (c)Junction Box with two coats of synthetic enamle paint over a coat of red oxide primerafter necessary preparation of surfaces including clamps,nuts ,bolts,wahers etc.Note :- for items 104.00(a), 104.00(b) & 104.00 (c)two coats of aluminimum paint will be used and deemed to be included into quoted rate . |
| 124 | S&F street light bracket made out GI Tubing, 40 mm dia medium grade of length 1.5 Mtr rendering bend of 120 degree including 2 pairs of clamps 30mm X 5 mm including nuts,bolts,washers including painting with two coat of synthetic enamel paint over a coat of red oxide primer on externalsurface of brackets complete all as specified and directed. |
| 125 | S&F in repair New generation energy saving and environmental friendly long life LED street light/building security fitting 30 Watt,made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. All as specified and directed by Engr-in-Charge. |
| 126 | M& L for fixingjunction boxmade of plastic material of size 239X328X129 mm withopaque cover ,conical cable gland aluminium lugs, Protection Class IP 65,04 nos aluminium bus bar of size 25x3 mm for three phase and neutral including 01 nos 06 Amps MCB SP for controlling street light and2 Nos MS clamp of size 30x5 mm complete with nut, bolt and washers for mounting the junction box on street light pole complete all as specified and directed |
| 127 | Supply & fixing PVC insulated aluminium conductor 2.5 Sqmm 2 Core cable with 1x2.5 sqmm PVC instulated aluminium conductor asearth wire for service connection of street light from junction box of LTelectric pole complete all as specified and directed. |
| 128 | Supply & fixing PVC insulated aluminium conductor 10 Sqmm 2 Core cable with 1x10 sqmm PVC instulated aluminium conductor asearth wire for service connection of street light fromLT Panel complete all as specified and directed. |
| 129 | S&F MCCB TP 125 Amp 415 Volts, 50 Hz suitable as per existing sample and connectionwith copper lugs including taking down old one complete all as directed. |
| 130 | S & F LED indicating light ( R,Y,B ) of LT panel suitable for 230 V ,50 Hz as per existing sample including taking out the old one. |
| 131 | S & F Voltmeter forof LT panel along with selector switch having four positions suitable for upto 600 V, 50 Hz as per existing sample including taking out the old one. |
| 132 | S & F Ammeterforof LT panel along with CT and selector switch suitable for upto 200 Amp ,50 Hz as per existing sample including taking out the old one. |
| 133 | S & F steel lock for LT electric panel in place of old unserviceable lock inclding taking down the old one as per existing sample. |