}

Tender For Special Repairs To Lt Cables, Regulating And Provost Complex Wiring, Galley And Toilet Block At Naval Base Porbandar Under Ge Navy Porbandar., porbandar-Gujarat

Tender Notice

51902413
Tender For Special Repairs To Lt Cables, Regulating And Provost Complex Wiring, Galley And Toilet Block At Naval Base Porbandar Under Ge Navy Porbandar.
Tender
Indian
Gujarat
Porbandar
20-11-2025

Tender Details

Tender For Special Repairs To Lt Cables, Regulating And Provost Complex Wiring, Galley And Toilet Block At Naval Base Porbandar Under Ge Navy Porbandar.; 1 Dismantling of floor hearth and wall tilling incl mortar beding removing serviceable tiles to store and rubbish off the premises asdirected by the Engr-in-Charge 2 M & L for Non Skid Ceramic coloured(colour & shade as approved) tiles non skid of size 400x400x7mm-8mm ( Exe 0.11 Sqm but n.Exe 0.18 Sqm )thick as in floor set and jointed in neat cement slurry over and including 15mm thick screed in cement mortar (1:6) and pointed in white cement with pigment to match the colour of tiles complete all as specified. 3 M & L for Glazed ceramic tiles, coloured (light colour as approved), of size300x 600 OR 350x 250x 7mm/ 450X 350X 7mm thick on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry over 15mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified. 4 Demolition of Stone slabs and tiles of any description or thickness in floors, aprons, compound walletc.laid dry beded in any mortor complete all as specified. 5 M&L for Granite work in steps, jambs, pillars, window-cills, cooking platforms laid over CM 1:4 , 15mm tk cement screed and jointed with grey cement slurry, and pointed with white cement with admixture ofpigment to match the shade of granite stone including grinding and polishing complete all as specified 6 M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete 7 M & L for Kota stone20 to 25mm thick of 40mm width for strip at doors cills in single pieces fixing with polymer modified tile adhesive of approved make etc complete 8 Taking down Shutters of any descriptionexc 1 sq. m and n exc 2 sq. m each and removing to store all as specified. 9 Taking down chowkats or frames exceeding 1.5sqm but not exceeding 4sqm eachwith shutters (without taking off shutters from the frame) and disposing off complete all as specified 10 S&F 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed 11 S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified. 12 S&F factory made 30mm 2 class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats all as specified and directed. 13 S&F fiber glass reinforced plastic (FRP) door frames of three legged of cross section 90 x 45 mm having single rebate of 32 x 15 mm to receive shutterof 30 mm thick. The laminate door frame moulded with fire retardent grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block of 2nd Class Hardwood in all the three legs. The frame shall be covered with fibre glass from all side M.S stay shall be provided at the bottom to sedy the frame complete as per direction of Engineer - in - Charge. 14 S&F 30 mm thick glass fiber reinforced plastics paneled door shutter of required colour & approved colour and manufactrures made with fire retardent grade unsaturated polister resin,moulded to 3mm thick FRP laminate for forming hollow rails & styles with wooden frame & suitable blocks of seasoned wood inside at required places for fixing of fittings along with MS tube frame of 19 gauge all around the styles & rails duly coated with steer primer castmonolithically with 5mm thick FRP laminate forpanels& conforming to IS:14856:2000 including fixing to frames. The shade & colour shall be approved by Engineer-in-Charge 15 S&F 300mm long (Length of Bolt in mm) Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified. 16 S&F 250mm long (Length of Bolt in mm) Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified. 17 S&F 200mm long (Length of Bolt in mm) Aluminium anodised,barrel tower bolts of extruded section and fixed all as specified and directed. 18 S&F 150mm (Size of Handle in mm) Extruded aluminium alloy handles, fabricated type,anodised all as specified. 19 S&F 100mm Butt hinges(Size of hinges in mm), medium weight, cold rolled, stainless steel, and fixed all as specified. 20 S&F 140mm long Floor door stopper of aluminium alloy body & tongue, anodised, with hard drawn steel spring. 21 S&F in repairspowder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified 22 S & Fin repairs aluminium grills with and including suitable aluminium anodised frame F/H section as required manufactured by M/S Decogrill as per design No DG-104 7.5 mm thick all as specified and directed. 23 S&F in repais Aluminium alloy wire cloth,0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples all as specified. 24 M&L preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 25 S&F 4.8 mm thick Sheet glass,ordinary quality pin headed type and glazing with Aluminium snap beading with rubber Neoprene packing in squareexc 0.5 sq. m in each paneall as specified and as directed 26 Taking down cementplaster on brickor stone masonrysurfaces of walls etc includingrakingout joints, hackingfor key, scrubbingdown with wateretc complete all as specified and directed. 27 M&L for 15 mm thick rendering in cement mortar 1:6 on stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and smooth (without using extra cement) complete all as specified and directed. 28 M&L for two coats of oil bound distemper over acoat of priming coat on newly prepared wall surfaces,including 3 mm thick layer of wall care putty (Birla white or equivalent)all as specified and directed.. 29 S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe)including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed 30 S&F in repairs of Viterious china wash hand basin white flat back of size 550x400 mm ,including brackets,waste coupling and waste pipe , or fixed with existing plateform surfaces with sealent with white cement etccomplete all as specified and directed. 31 S&F Looking600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified 32 Taking down or up steel tubing and connections incl cleaning for refixing or removal to store upto 25 mm dia bore. 33 Supplying and laying of 16mm of CPVC pipes to CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specifiedas in repair complete all as specified directed. 34 Supplying and laying of 20mm of CPVC pipes to CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specifiedas in repair complete all as specified directed. 35 Supplying and laying of 25mm of CPVC pipes to CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specifiedas in repair complete all as specified directed. 36 Dismantling of water tank RCC/HDPE/Ferrocrete and removing it to storeof size exceeding1000 Ltrs to 2000 Ltrs capacity. 37 S & F rotational moulded polytheline water storage tank 1000 Ltrscapacity (cylinderical / vertical with closed top) hoisted and fixed inposition. 38 S&F in repairs 15mm Bib taps, cast copper chromium plated with crutch orbutterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed 39 S&F in repair 15mm Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed 40 S&Fin repair Stop valves, cast copper alloy, screwed down, highpressure, withcrutch or butterfly handle, fancy type, chromium plated screwed both ends foriron pipe orfor unions and fixed 41 S&F in repair Gun-metal, globe or gate valves 25 mm dia bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed 42 S&F Ball brass valves 25mm dia bore, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed 43 S&F as in repairs Brasschromiumplatedshower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union 44 S&Fin repair PVC connection 600 mm length 45 S&F in repair toilet paper holder, brass chromium plated fixed to walls withbrass screws. 46 S&F in repair Brass Chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges 47 M & L for cast iron floor trap with 100mm dia outlet , with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 all as specified. 48 Dismantling Cast iron or reinforced cement concrete drain pipes jointed in cement mortar and taking out of trenches if required for internal dia of pipe upto 100 mm including all fittings ( Tee, Bend, branch piece etc.,). 49 S&F PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall, bore of pipe 75 mm 50 S&F PVC (SWR) bend any radius, 75mm bore 51 M & Lfor PCC1 : 3 : 6Type C2 ( 40 mm graded aggregsate) as in foundation and mass concrete. complete all as specified and directed. 52 M & L for Concrete bed1 : 3 : 6Type C2 for drain pipes including packing under, and haunching againstthe sides of pipes after they are laid and tested; in complete all as specified and directed. 53 M&L for 150 mm Reinforced concrete pipes,class NP3, laid and jointed complete with collars in complete all as specified and directed. 54 Dismantling of plain / corrugated steel sheeting, any gauge, thickness as in roof complete all as specified and directed. 55 S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with necessary self tapping/ hook screws as specified 56 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. 57 S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) includingdistance pieces, cleats etc complete all as specified and directed 58 M&L for Preparing of new or priviously untreated steel surfaces, over 10cm in width or girth,not otherwise described including washing and cleaning etc., and applying 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. 59 M & L for preparation of newly plastered surfaces of Ceiling and applying three coats of white wash 60 Demolition of unreinforced cement concrete in ground floor and paving n.exc 15 cm thick below or above ground level complete all as specified and directed 61 M & L for 50mm tk Cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in plinth protection,Floor topping etc , surfaces finished of concrete flooring with brooming complete all as spd u including provision of necessary construction joints complete all as directed by Engr-in-Charge 62 S&F in repairs to CP grating square min 150mm size Complete all as spd 63 S&F in repair to ABS body Health faucetwith wall hook and 1 metre SS braided rubber holes pipe MakeCera Cat Name :CERA -F8030102OR f8030301Equallent make and model approved by GE. 64 S&F in repairs CP brass wall mixer for mixing hot & cold water with bend pipe for over head showerscrewed down for CPVCand fixed as in repair comeple all as spd MakeCera Cat Name :CERA -F2002401Equallent make and model approved by GE. 65 Taking down old point wiring complete for (light, fan, socket 5/15 amps, bell point etc)complete with all light fittings accessories , such asswitches,sockets 5/15 Amps, ceiling roses, pendents, regulators, sockets etc removing materialsfor taking creditand making good disturbed surfaces of walls, floors, etc all as speified and directed by Engineer -In-Charge. 66 M& L for point wiring with PVC insulated unsheathed stranded copper conductor cable FRLSH of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width or in concealed conduit non metallic , rigid PVC conduit of adequated size(as per site requirement) with all fittings and conduit accessories including suiitable size modular metal flush box and modular white cover plate with frame for housing the switches,socket outlets ,including all necessary wall cutting and making good disturbed surface allas directed and specified .Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate. 67 One light point controlled by one, one way switch 68 One ceiling /exhaust fan point controlled by one switch and regulator 69 Ditto all as per above item No. 66.00 but wire 2.5 sqmmOne 3 pin 5 amp socket out point on the independent board 70 Ditto all as per above item No. 66.00 but wire 2.5 sqmmOne3 pin 5 amps socket out let point on same board with other switches. 71 Ditto all as per above item No. 66.00 but for one socket outlet 15 amp on independent boardwith4.0Sq.mmcableand4.0Sq.mm.earthwire. 72 M & L for point wiring with PVC insulated unsheathed stranded copper conductor cable FRLSH of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC conduit medium grade not less then 20 mm width/in concealed conduit non metallic , rigid PVC conduit of adequated size with all fittings and conduit accessories including suiitable size modular metal flush box and modular white cover plate with frame for housing the switches,socket outlets ,including all necessary wall cutting and making good disturbed surface allas directed and specified .Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate. 73 One light point controlled by one, one way switch 74 One ceiling fan point controlled by one, one way switch 75 Ditto all as per above item No. 70.00 but wire 2.5 sqmmOne 3 pin 5 amp socket out point on the independent board 76 Ditto all as per above item No. 70.00 but wire 2.5 sqmmOne3 pin 5 amps socket out let point on same board with other switches. 77 Ditto all as per above item No. 70.00 but for one socket outlet 15 amp on independent boardwith4.0Sq.mmcableand4.0Sq.mm.earthwire. 78 S & F in replacement Modular switch 1 way 6A, 1 module all as specified and directed by EIC. 79 S & F in replacement Ceilingrose, surface bakelite 65x50 mm three terminal 80 S & F in replacementmodular socket, Socket, 6A - 2/3 pin combined 2 module all as specified and directed by EIC. 81 S & F in replacement Modular switch 1 way 16A, 1 module all as specified and directed by EIC. 82 S & F in replacementmodular socket 16A - 2/3 pin combined 2 module, all as specified and directed by EIC. 83 S & F in replacement earth enclosure with 2 pin earth plug sokcet complete with MCB SP 25 amp,flush mounting type 84 S & F in replacement Modularfan regulator 120 Watt, 2- module , AC 240 Volts complete. 85 Taking down fan of any make/type/sweep,sealing cable end ,dismantling of blades and for repair /overhauling complete all as directed 86 M &L for Overhauling of ceiling fan /exhaust fan of any make and sweep after opening and cleaning rotor bearing and stator properly, rewinding motor windings and oiling/greasing of bearing/ bushes,replacement of capacitor & reassmbling the same,& painting with similar colour ,fixing and connecting on its existing position and testing on completion all as specified and as directed . 87 M &L for Painting of ceiling fan/Exhaust Fan of anysweep complete including fan blade down rod with synthetic enamelled paintby spraying including cleaning and removing dust by polish paper and dirt and making smooth surface for painting ,filling cavities with filler 88 Fixing or hanging only ceiling fan/Exhaust fan after overhauling/repair ofwinding above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed 89 S & F in replacement LED tube light fittings 4 feet 1x20 Watt ,220V, Indoor decorative LED Engineering Plastic batten with opal diffuser, IP 20 and with System Efficacy of 100lm/W ,holder including LED Tube light connecting up with 3 core flexible cppper conductor cable with sutable size from ceiling rosecomplete all as directed by Engr-In-Charge. 90 S & F in replacement LED tube light fittings mirror type with high output diffuser 2 feet ,1x10 Watt ,220V, Indoor decorative LED Engineering Plastic batten with opal diffuser, IP 20 and with System Efficacy of 100lm/W, holder including LED Tube light connecting up with 3 core flexible cppper conductor cable with sutable size from ceiling rose complete all as directed by Engr-In-Charge. 91 S & F in replacement Inverter LED batten 20Watt with square profile and polycarbonate channel. Lithium Ion battery with charging time8hours-10 hours and back up time upto 4 hours.connecting up with 3 core flexible cppper conductor cable with sutable size from ceiling rosecomplete all as directed by Engr-In-Charge. 92 Supply and fixing in replacement LED street light fitting 35 Watt,230 V AC outdoor typewith high pressure die aluminium housing and heat resistant complete withdriver , lamp, with impact and corrosion resistanct including thermal management in multiple optics, including suitable size mountingbracket , clamps ,nut,boltscomplete with IP 65/66 protectionall as specified and directed by Engr-in-Charge. 93 Supply and fixing in replacement round/square shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. 94 S & F in replacement MCCB DB VERTCLE TYPE made of sheet steel, powder paintedwith NUTRAL bus bar 200 A, neutral link,IP-43-IK09protection grade, 415 Volts TPN with 8 way Double door complete all as specified and as directed. 95 S & F in replacement MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade, 415Volts TPN with 4 way Double door 96 S & F in replacement MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link,IP-43-IK09 protection grade , 415Volts TPN with 6 way Double door 97 S & F in replacement MCB DB made of sheet steel , powder painted withNUTRAL bus bar 200 A, neutral link, earth bar and Din rail , 240Volts SPN with 12 way Double doorIP-43-IK09 protection grade, 98 Note for Item No. 91.00 to 94.00 (1).The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall./ DB to be fixed on wall(2).The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface. (note - rate is inclusive of cutting chaseS & F in replacementin repair lush to wall & making good to the disturbed surfaces of walls etc to macth with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes making good disturbed surfaces of walls, etc ) 99 S & F in replacement MCB TPN 415 Volts, C series, breaking capacity 10 KA of rating 40to 63Amps 100 S & F in replacement MCB TP 415 Volts, C series, breaking capacity 10 KA of rating 25to 63 Amps 101 S & F in replacement MCB SPN 240 Volts, C series, breaking capacity 10 KA of rating 40 to 63Amps 102 S & F in replacement MCBSP 240 Volts C series, breaking capacity 10 KA of rating 6-32 Amps 103 S & F in replacement MCB TPN 100 Amps , 415Volts, 16-18 KA complete all as specified and as directed. 104 S & F in replacement MCCB 4P 160 Amps , 415Volts, 16-18 KA complete all as specified and as directed. 105 S & F in replacement Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through in concealed conduit non metallic , rigid PVC conduit of adequated size with all fittings and conduit accessories completeall as directed by Engineer in Charge.Notes:- (i)Two wires of 6sqmm and one wire of 6sqmmand one run of PVC Conduitshall be measured as one unit. 106 S & F in replacement Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH4 Single core of size 10 Sqmm, earth continuity conductor of size 1X 10 Sqmm to be drawn through and in concealed conduit non metallic , rigid PVC conduit of adequated size with all fittings and conduit accessories complete all as directed by Engineer in Charge.Notes:- (i) four wires of 10 sqmm and one wire of 10 sqmmand one run of PVC conduit /casing caping shall be measured as one unit. 107 S & F in replacement Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through in concealed conduit non metallic , rigid PVC conduit of adequated size with all fittings and conduit accessories completeall as directed by Engineer in Charge.Notes:- (i)Two wires of 4sqmm and one wire of 4sqmmand one run of PVC Conduitshall be measured as one unit. 108 Supply, laying and fix in repair/replcement ofLT Cable laid in trenches, passing through pipes and fixed on wall/floor/ceiling with proper saddles , including testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor ofsize 109 400 sqmm 3.5 core 110 240 sqmm 3.5 core 111 120 sqmm 3.5 core 112 95 sqmm 3.5 core 113 70 Sqmm 3.5 core 114 50 Sqmm 3.5 core 115 35 Sqmm 3.5 core 116 16 Sqmm 4 core 117 Earth work in excavation by mechanical means (Hydraulic excavator) / in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the hard/ dense soil and disposal of surplus excavated soil as directed, within a lead of 50m as directed by Engineer-in-charge 118 Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. 119 Removing excavated material n. exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 120 S& F in replacement oflaying of Double Walled Corrugated(DWC) HDPE pipe of following size of conforming to IS 16205 Part -24including necessary bends,coupling ,tees, reducers, spacers,end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge Make:-ASTRAL TELEREX /eqivalent as approved by GE 121 40/32 mm outer/inner dia 122 50/38 mm outer/inner dia 123 63/50 mm outer/inner dia 124 90/75 mm outer/inner dia 125 Taking down old u/s LT panel of any size/ make/ including all unserviceable parts removing from site all as directed & specfied at site 126 Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with airinsulated PVC sleeved Copper bus bar of rating 400 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, includingNeoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and50 X 50 X 6 mm thick MS angle iron frame 30 cm above and 60 cm below normal ground levelwork front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glandsand PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:- 127 (A) Incoming:- (a) Copper bus bar TPN 400 Amps - 01 Set (b) Voltmeter 3 phaseclass .5(L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter3 phaseclass1(L &T Model No-WL132020OOOO ) -01 Nos(d) Phase indicating lamp R, Y, B LED(L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT of suitable ratio (f)Danger notice plate/ sticker of suitable size on front panel board -01 No (g) Incoming MCCB 160A 4P 25 kA -01 No (Legrand- 4200 57) (B) Outgoing:-(a) MCCB 100 A TP 25 KA (LEGRAND- 4200 45) -03 No (b) MCCB 63 A TP 25 KA (LEGRAND- 4200 43) -4 (c) All out going LTfeeders name with radium stickers.Note:- MCCB Make:- Legrand (DPX series)/L&T (d-sine series) /Schenider (d) All MCCB to be connected through busbar only, no PVC wire is allowed. 128 Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor typefloor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with airinsulated PVC sleeved Copper bus bar of rating 1000 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, includingNeoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glandsand PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:- 129 (A) Incoming:- (a) Copper bus bar Four Pole1000 Amps - 01 Set (b) Voltmeter 3 phaseclass .5 -01 Nos (c) Ammeter3 phaseclass1 -01 Nos(d) Phase indicating lamp R, Y, B LED - 01 Set (e) CT 100X5 - 3 Nos (f) MCCB 630 A 4P 50 kA with thermal magnetic release-01 Nos (g)Danger notice plate/ sticker of suitable size on front panel board -01 No(B) Outgoing:- (a) MCCB 200 A 4P 25 kA with thermal magnetic release-05 Nos(b) MCCB 100 A 4P 25 kAwith thermal magnetic release-02 Nos(c) MCCB 63 A 4P 16 kAwith thermal magnetic release-02 Nos(d) All out going LTfeeders name with radium stickers -10 Nos Note:- MCCB Make:- Legrand(DPX series)/L&T(d-sine series) /Schenider (d) All MCCB to be connected through busbar only, no pvc cable connection is allowed 130 Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor typefloor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with airinsulated PVC sleeved Copper bus bar of rating 300 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, includingNeoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glandsand PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:- 131 (A) Incoming:- (a) Copper bus bar Four Pole300 Amps - 01 Set (b) Voltmeter 3 phaseclass .5-01 Nos (c) Ammeter3 phaseclass1-01 Nos(d) Phase indicating lamp R, Y, B LED- 01 Set (e) CT 100X5 - 3 Nos (f) MCCB 200 A 4P 25 kA with thermal magnetic release-01 Nos (g)Danger notice plate/ sticker of suitable size on front panel board -01 No(B) Outgoing:-(a) MCCB 63 A 4P 16 kAwith thermal magnetic release-04 Nos(b) MCCB 100 A 4P 16 kAwith thermal magnetic release-02 Nos(c) All out going LTfeeders name with radium stickers -04 Nos Note:- MCCB Make:- Legrand(DPX series)/L&T(d-sine series) /Schenider. (d) All MCCB to be connected through busbar only, no pvc wire is allowed 132 Supply and fixingof ON load change over switch with sheet steel Enclosure 415 V, 4 pole, 400 Amps capacity fixed on walls/MS frame/pole/LT panel for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches complete all as specified and directed. Make : L&T/ C&S/ Havells 133 Supply & installation of Jef Ecosafe Maintenance free and Environment Friendly Earth Electrode set comprising of 17.2mm dia 3 mtrs long rod of Low carbon steel, molecular Copper Bonded for a thickness of 250 microns, highly conductive ANSI NSF STD 60 Certified, with 1Bags(50P) of environment friendly carbon based backfill compound, according to BS 7430 & IEEE 80 and with suitable Clamp in 100mm dia bore hole complete all as specified and directed by Engineer-in-Charge. 134 M &L for Repair of exhaust fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of all unserviceable spares parts as required ,including necessary lathe work for fixing of bush/bearinggreasing the same with approved grade of grease, making all electrical connection and refixing the same back to its origibal position including necessary transportion to workshop, 225 to 300 mm sweep complete all as specified and as directed. 135 M & L for FixingExhaustfan after complete overhauling of exhaust fan as required at siteand connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan (max up to 1m length) all as specified and directed 136 M& L for opening the geyser 25/50 ltr capacity and taking out inner tank and glass wool from inside the geyser , descaling & washing with acid to remove the scales, dirt etc if any and refixing the same after reassembly into geyser and proper filling of new glass wool around inner tank complete all as specified & directed (NOTE:- Glass wool will be measured & paid separately under relevant item of the schedule) 137 S & F in replacement Glass wool pf any colour complete all as directed by Engineer-in-Charge 138 S & F in replacement of Geyser inner water storage tank of anytype capacity 25/50 ltr make of metal stainless steel as specified and directed 139 S & F in replacement heating element 1500 watt make of Bajaj / Tosiba / Havells / as suitable for geysers make all as specified and directed by Engineer –in-Charge 140 S & F in replacement heating element 2000 watt make of Bajaj / Tosiba / Havells / as suitable for geysers make all as specified and directed by Engineer –in-Charge 141 S & F in replacement themostat for geyser make of Bajaj / Tosiba / Havells / as suitable for geysers make all as specified and directed by Engineer –in-Charge 142 S & F in replacement neone lamp for geyser yellow / red as directed by Engineer –in-Charge 143 S & F in replacement air realese valve for geyser as specified and directed 144 S & F in replacement geyser hot & cold water connection hose of size 450/600 mm longarmoured type both side brass union type nuts complete including removal of old pipeas specified and directed 145 S & F in replacement anchor bolts 75mm long made out of stain less steel complete all as specified and directed 146 M&L for replacement of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate notlessthan 1.5 metres below normal ground level, connected to galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion 147 Supply & JOINT cable jointing kitheat shrinkable 1.1KV XPLE straight through jointof size 16 sqmm 3.5 core to 50 sqmm 3.5 core cable size complete. Make:-Denson/3M/Raychem 148 Supply & JOINT cable jointing kit heat shrinkable 1.1KV XPLE straight through joint of size 70 to 120 sqmm 3.5core cable size complete. Make:-Denson/3M/Raychem 149 Supply & JOINT cable jointing kit heat shrinkable 1.1KV XPLE straight through joint of size 240 to 400 sqmm 3.5core cable size complete. Make:-Denson/3M/Raychem

Key Value

Document Fees
INR 1000 /-
EMD
INR 162865.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail