| 1 | Taking down unserviceable/old ACSR conductor any size from over head lines, poles by removing binding wireand removal from site complete all as specified and directed. |
| 2 | M & L for Dismantling unserviceable cross arms, clamps etccomplete all as specified and directed. |
| 3 | M & L for Dismantling insulator any type, any size from HT/LT poles complete all as specified and directed. |
| 4 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 2 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and directed. |
| 5 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 4 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and directed. |
| 6 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and directed. |
| 7 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and directed. |
| 8 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 50 sqmm3.5 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and directed. |
| 9 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 95 sqmm3.5 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and directed. |
| 10 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 120 sqmm3.5 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and directed. |
| 11 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 185 sqmm3.5 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and directed. |
| 12 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 240 sqmm3.5 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and directed. |
| 13 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 300 sqmm3.5 core laid in trenches /floor or fixed on wall/pole in including brass compression cable glands, terminal lugs etc, complete all as specified and directed. |
| 14 | Excavation in trenches n.exc 1.5mtr wide and n.exc. 1.5m in depth for foundation and getting out in soft/loose soil complete all as specified and directed. |
| 15 | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. Note :- Only punned down sand shall be measured. |
| 16 | M&L for bricks sub class ‘B’ brick old size for cable protection laid in flat in trenches over the cable perpendicular to the direction of cable complete all as specified and directed. |
| 17 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc. 25cm complete all as specified and directed. |
| 18 | Removing of excavated soil not exc 50cm & depositing where as directed at a level n.exc 1.5m above starting point complete all as specified and directed. |
| 19 | Excavation in trenches n.exc 1.5mtr wide and exc. 1.5m in depth for foundation and getting out in soft/loose soil complete all as specified and directed. |
| 20 | M&L for GI pipe light grade 40mm bore dia with all fittings to be laid in trenches or in floors,including taking down rusted one complete all as specified and directed. |
| 21 | M&L for GI pipe light grade 50mm bore dia with all fittings to be laid in trenches or in floors,including taking down rusted one complete all as speciffied and directed. |
| 22 | M&L for GI pipe light grade 80mm bore dia with all fittings to be laid in trenches or in floors,including taking down rusted one complete all as speciffied and directed. |
| 23 | M&L for GI pipe light grade 100mm bore dia with all fittings to be laid in trenches or in floors,including taking down rusted one complete all as speciffied and directed. |
| 24 | M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation complete all as specified and directed. |
| 25 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in mass concrete including necessary form work for coping to the new/existingSteel Poles complete all as specified and directed. |
| 26 | M&L for Boring of holes under road / Cutting of roads for passing cable any size and any type includingmake good damaged surface with cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate)/black bitumin carpet complete all as specified and directed. |
| 27 | Taking down existing UNSV UG cable from trench wall floor or hanging to pole complete including disconnectiong from incoming and outgoing of various size upto 240 Sqmm complete all as specified and directed. |
| 28 | Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 1.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed. Note - Two runs of 1.5 sqmm cable, one run of 1.5 sqmm cable and one run of conduit shall be measured and paid as one unit length. |
| 29 | Supply and fixstreet light junctionbox made of high quality polycarbonate with IP-66 protection (Dust and vermin proof according to IEC-60529) Totally insulated made of halogen and silica free recyclable material having high quality gasket made out of polyurethane, locking arrangement with cable gland suitable upto 10 sqmm cable and necessary fixing arrangements such as clamps, nuts, bolts etccomplete all as specified and directed. |
| 30 | Supply & fixing of LT Panel Board floor mounted outdoor cubical type (CPRI Approved) with compartments for each out going and incoming feeders made of CRCA of 3.15 mm thick MS sheet power coated of suitable size with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs frame with double hinged with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for existing cables, danger notice plate, strickering of Switcher gear and termination of switch gear and the nuts/ bolts etc used are to be made of rust proof material, incl tinned Aluminium bus bar as per IS TPN LT AC, 50 Hz , 415 V, 1000 Amp capacity complete with powder coating and comprising of the following accessories:-Incoming:a) MCCB 4 Pole, 415 V, Adjustable type, 630 Amps with breaking capacity 50 KA-01 No.Outgoing:b) MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA-03 Nos.c) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 36 KA-02 Nos.d) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs e) LED indicating lamps with colour Red, Yellow, Blue - 01 Set |
| 31 | Supply & fixing of LT Panel Board floor mounted outdoor cubical type (CPRI Approved) with compartments for each out going and incoming feeders made of CRCA of 3.15 mm thick MS sheet power coated of suitable size with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs frame with double hinged with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for existing cables, danger notice plate, strickering of Switcher gear and termination of switch gear and the nuts/ bolts etc used are to be made of rust proof material, incl tinned Aluminium bus bar as per IS TPN LT AC, 50 Hz , 415 V, 1000 Amp capacity complete with powder coating and comprising of the following accessories:-Incoming:a) MCCB 4 Pole, 415 V, adjustale type, 200 Amps with breaking capacity 36 KA-01 No.Outgoing:a) MCCB 4 Pole, 415 V, adjustale type, 63 Amps with breaking capacity 16 KA-06 Nos.b) MCB 4 Pole, 415 V, C-series 40 Amps with breaking capacity 16 KA-04 Nos.c) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTsd) LED indicating lamps with colour Red, Yellow, Blue - 01 Set |
| 32 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing strip of 25 x 4 mm galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe light grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing including taking down old earthing complete all as specified and as directed. |
| 33 | M & L forjointing heat shrinkable after removing faulty cable , straight joints for PVC armoured heavy duty underground cable including joint kits complete for making joints suitable for aluminium Conductor cable 25 to 50 sqmm 3½ core 1100 volts grade and necessary testing after jointing, complete all as specified and directed. |
| 34 | M & L forjointing heat shrinkable 1100 volts XLPE straight joints for PVC armoured heavy duty underground cable including joint kits complete for making joints suitable for aluminium Conductor cable 70 to 120 sqmm 3½ core 1100 volts gradeand necessary testing after jointing, complete all as specified and directed. |
| 35 | Supply & jointing heat shrinkable 1100 volts XLPE straight joints for PVC armoured heavy duty underground cable including joint kits complete for making joints suitable for aluminium Conductor cable 150 to 185 sqmm 3½ core 1100 volts gradeand necessary testing after jointing, complete all as specified and asdirected |
| 36 | Supply & jointing heat shrinkable 1100 volts XLPE straight joints for PVC armoured heavy duty underground cable including joint kits complete for making joints suitable for aluminium Conductor cable 240 to 300 sqmm 3½ core 1100 volts gradeand necessary testing after jointing, complete all as specified and directed. |
| 37 | Supply & fixLT Timer Panel box 3 ph 6KW rating with 32A TP contractor, 40 Amp TPN MCB and astronomcal timer and floor/wall mounted cubical type including MCB, Timer and contactor outgoing and incoming cablemade ofMS sheet power coated of suitable size with support angle iron bottom legs framewith front opening, with projection of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for existing cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material complete all as specified and directed. |
| 38 | Dismantling unserviceable steel poles of any size including demolition of foundation concrete & removing from sitecomplete all as specified and directed. |
| 39 | M&L for erection of steel tubularsteel tubular swaged pole type 410 SP - 31 (9.00 metres long) including cast iron base plate, finial taper plugandand painted with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 40 | Supply and fixing in repairs street light bracket made of GI pipe 40 mm bore light grade (bend to shape), 2 metre longand fixed with Ms flat iron clamp(clamp shall be 40 X 5mm), nuts, bolts and washers on pole complete all as specified and directed. |
| 41 | Supply and fixing LED street light of capacity 70 Watt made up of pressure die cast aluminium housing withhigh power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥120 lumens/watt, CRI>70, PF > 0.95, CCT≥5500, IP66, impact resistance IK 07, inbuiltprotection against lightning, over voltage, short circuit and surge/spike protection device upto5 kVincluding taking out old unserviceable luminare complete all as specified and directed. |
| 42 | Dismantling stay assembly complete. all as directed by engineer in charge.Note:- Demolition of concrete, etc. and excavation measured separately). |