Tender For Special Repair To Street Light System In Southern Sector At Mil Stn Kota; (a) Cable, cords and earth lead 19.24 (b) Cable Cable for internal wiring for light fitting, power and sub mains 19.25 (c) Conduit & conduit fittings 19.29 (d) Ceiling rose 19.32 (e) Socket outlet 19.40 (f) Fluorescent tube light fittings and accessories 19.35 (g) Sunk type boxes 19.38 (h) Lamp holders 19.41 (j) Distribution fuse boards and cutouts 19.44 (k) Main switches 19.45 (l) MCBs 19.46 (m) Screws and fastenings 19.31 (n) Wooden plugs and rawl plugs 19.30 (o) Wooden battens, blocks and boards 19.28; 1 M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine including insertion of HDPE pipe upto 90 mm dia for protection of LT cable and including taking necessary permission from Railway/ MSEDCL/ any other department complete all as specified and as directed. Note : HDPE pipe shall be measured and paid separately. 2 Supply, laying, jointing, testing and commissioning in renewal of cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. 3 Supply, laying, jointing, testing and commissioning in renewal of cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. 4 Supply, laying, jointing, testing and commissioning in renewal of cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. 5 M & L in renewal for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. 6 Dismantling concrete poles/ struts, any size including brackets, light fitting, junction box etc and transporting to store and stacking or for schedule of credit complete all as specified and directed. 7 Supply and installation of Decorative pole (CI+MS) (8 mtr long) including Single arm bracket, Pole must have lower section OD 114mm and top section 76mm diametre made out of GI pipe as per IS 1239 having two ornamental decorative staining golden colour made of pressure die casting in aluminium at bottom and middle. The pole shall have window cutting of 300mm x 80mm weather proof flush door & locking arrangement for housing of the pole to accomodate electrical accessories (Bakelite plate and connector) for power supply connection.The window cover is fitted with allen screws to the pole and is to be provided in bottom section of pole. The body of pole shall be machined and polished properly to give it a smooth surface as per IS 2629 and IS 2633. The decorative pole shall be duly pre-treated and painted UV resistant coating in grey colour shade. The pole and the cast iron embellishments should be machined & polished properly to get thesmooth finish.The coating should have a DFT of 80-90 microns.Entire unit shall be given an extensive three stage treatment with PU based primer,Zinc phosphate primer and poly urethane paint of approved colour & prescribed for such surfaces to make it absolutely rust and corrosion proof as well as giving it a pleasing appearance.Base plate outside PCC of size 250mmx250mm with 12 mm thickness having 4 holes of 20mm dia at a distance of 200mm complete with CI base plate inside PCC complete all as specified and as directed. Decorative Arms must have Sturdy design made of 76mm dia GI pipe for pole mounting and 48mm dia GI pile for product installation. Golden knob is provided at the top to enhance the aesthetics of the product. Brackets can be mounted on poles with top dia less than70mm. Bracket must be Hot dip galvanised with minimum average GI coating of 35μm. PU(Polyurethane) Painted with avg. thickness of 80μm in Grey colour (RAL-7024). Single and double arm brackets can be installed on the pole (dia <70mm) using M8 X 15 hex bolt provided with the product. Manufactures should have NABL approved lab. Manufacturer should have both product Pole along with Arm and Street Lights for better aesthetics including connector with aluminium bus bar suitable for 3 phase and neutral, 4 wire of capacity 32 Amps and one No MCB SPN of capacity 6Amp to 10 Amp fixed with nut, bolts, clamps etc complete all as specified and directed. Note: Cost of studs, nuts & bolts and connected accessory shall be included in the rate quoted. PCC shall be measured & paid separately under appropriate item. 8 Supply and installation of Decorative pole (CI+MS) (8 mtr long) including Four arm bracket, Pole must have lower section OD 114mm and top section 76mm diametre made out of GI pipe as per IS 1239 having two ornamental decorative staining golden colour made of pressure die casting in aluminium at bottom and middle. The pole shall have window cutting of 300mm x 80mm weather proof flush door & locking arrangement for housing of the pole to accomodate electrical accessories (Bakelite plate and connector) for power supply connection.The window cover is fitted with allen screws to the pole and is to be provided in bottom section of pole. The body of pole shall be machined and polished properly to give it a smooth surface as per IS 2629 and IS 2633. The decorative pole shall be duly pre-treated and painted UV resistant coating in grey colour shade. The pole and the cast iron embellishments should be machined & polished properly to get thesmooth finish.The coating should have a DFT of 80-90 microns.Entire unit shall be given an extensive three stage treatment with PU based primer,Zinc phosphate primer and poly urethane paint of approved colour & prescribed for such surfaces to make it absolutely rust and corrosion proof as well as giving it a pleasing appearance.Base plate outside PCC of size 250mmx250mm with 12 mm thickness having 4 holes of 20mm dia at a distance of 200mm complete with CI base plate inside PCC complete all as specified and as directed. Decorative Arms must have Sturdy design made of 76mm dia GI pipe for pole mounting and 48mm dia GI pile for product installation. Golden knob is provided at the top to enhance the aesthetics of the product. Brackets can be mounted on poles with top dia less than70mm. Bracket must be Hot dip galvanised with minimum average GI coating of 35μm. PU(Polyurethane) Painted with avg. thickness of 80μm in Grey colour (RAL-7024). Four arm brackets can be installed on the pole (dia <70mm) using M8 X 15 hex bolt provided with the product. Manufactures should have NABL approved lab. Manufacturer should have both product Pole along with Arm and Street Lights for better aesthetics including connector with aluminium bus bar suitable for 3 phase and neutral, 4 wire of capacity 32 Amps and one No MCB SPN of capacity 6Amp to 10 Amp fixed with nut, bolts, clamps etc complete all as specified and directed. Note: Cost of studs, nuts & bolts and connected accessory shall be included in the rate quoted. PCC shall be measured & paid separately under appropriate item. 9 Supply and fixing in renewal of decorative 90 Watt Street Light, designed with a classic look using new generation technology in LED to enliven your outdoor areas in perfect synchronization with functionality and aesthetics, family of post-top lanterns designed to complement the geometry of the area with heritage touch. Light should have UV protected pure polyester powder coated grey after phosphochromate treatment, polycarbonate cover Injection melded, clear polycarbonate cover with IK09 impact resistance rating. Light must have secondary optics for better light distribution. Product should not more than 90W and Light Output should not less than 11500 lumens with operating temperature of 50 degree and Voltage range 140V to 270V. Average life of product should be 50000 hr, driver Built-in potted electronic LED driver with APFC, (SMPS based constant current supply), lower THD, Open Circuit Protection, over Voltage protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13 complete all as specified and directed. 10 S & F in renewal of three core flexible conductor FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed. 11 Supply & fixing in renewal of feeder pillar box of outdoor type fabricated out of 3.15 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:-(a)Aluminium bus bar 250 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(a) MCCB FP 40 Amps, 415 V, 25 KA - 01 No for main in coming (b) MCB TPN 25 Amps 415 V FP, 16 KA - 02 Nos (c) MCB SP 10 A 10 kA-01 Nos(d) LED indicator for RYB of size 22.5 mm - Set of 3(e) Multifunctional meter for freq, power factor, amperes, voltage etc. - 01 set (f) Street light timer using Power contactor 32 Amps, (1-NO), 3 pole, 415Volt, DIN type digital programable time switch 230V AC, Auto/Manual selector switch, MCB TPN, 32 Amps, ON/OFF indicator all prewired and making provision for fixing outgoing cables - 01 Set complete.Note: All MCCBs must conforms Fixed thermal and fixed thermal magnetic setting and Ics= 100% of IcuNote: Leg height of angle iron frame for panel must not be less than 100 cm above the PCC base to avoid water logging. 12 M & L n renewal for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. 13 Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed. 14 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. 15 Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 16 Supply and laying high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 63 and nominal dia 50 mm including all fittings and fixtures in trenches complete all as specified and as directed. 17 M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed. 18 M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.