| 1 | Repair to potholes any depth, not exc 1 sq m each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25mm in depth, making good by filling in screened & graded road metal, watering and well ramming (including supply of road metal) complete all as specified and directed by Engineer-in-Charge. |
| 2 | Preparing surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and directed by Engineer-in-Charge. |
| 3 | M&L for applying evenly a tack coat of Cationic Bitumen Emulsion (RS-1) conforming to IS: 8887 at a rate of application of 0.2-0.3 kg/sqm on bituminous surface as specified in Table 500-5 of MaRTH specification for road and bridge works 2013, using mechanica sprayer after cleaning of existing surface complete all as specified and directed by Engineer-in-Charge. |
| 4 | M&L for bituminous premix semi dense asphaltic concrete(SDAC), 30 mm thick (consoilidated average thickness) in single layer using paving bitumen VG-30 with 5.5% binder content mixed in hot mix plant using design mix and laid by mechanical paver and rolled and compacted with using 8 to 10 tonne cap vibratory power roller to achieve the required compactness, camberand gradient finished complete including (cutting of edges of roads straight and site clearence) etc complete all as specified and directed by Engineer-in-Charge. |
| 5 | Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area exc 400 sqm exceeding 50mm and not exceeding 100mm deepunsarfaced water bound macadem surfaces for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt, etc complete all as specified and directed by Engineer-in-Charge. |
| 6 | M&L for applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate of application of 0. 7-1 kg/sqm on surface of WMM/WBM/BM as specified in Table 500-3 of MoRTH specification for road and bridge works 2013, using mechanical sprayer complete all as specified and directed by Engineer-in-Charge. |
| 7 | M&L for Premix bituminous macadam laid/rolled and compacted to required gradient and camber (consolidated thickness upto 75mm or less), by using 4% bitumen content any penetretion using bitumen of grade VG-30 confirimg to IS-73-2006) etc complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L for 100mm thick Moorum/Red bajri, spread, rolled, consolidated & gradient and camber required complete all as specified and directed by Engineer-in-Charge. |
| 9 | Dismantaling Stone slabs and tiles laid dry or laid dry and pointed of any description or thickness in floors, aprons etc. complete all as specified and directed by Engineer-in-Charge. |
| 10 | M&L for Sand Stone kerb of roughly squared stones of size 15cm x 30cm, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar1:6 and struckflus complete all as specified and directed by Engineer-in-Charge. |
| 11 | Demolition ofPCC in Ground Floor and paving n exc 15 cm (below or above ground level) complete all as specified and directed by Engineer-in-Charge. |
| 12 | M&L for 100mm thick PCC type D-2, 1:4:8 using 40mm (graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge. |
| 13 | M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and directed by Engineer-in-Charge. |
| 14 | Demolition of precast concrete articles and other similar works complete all as specified and directed by Engineer-in-Charge. |
| 15 | M & L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curveshall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&Lfor marking 2.50 mm thick centre line, stop line, dashes, arrows, brackets & similar etc. and the like exc 10cm wide on road surfaces as per IRC pattern with thermo plastic paint of approved quality & make with 8% glass beads laid at temperature 160 C with a special applicator machine complete all as per manufacturer\"s instructions & traffic diversion arrangement complete all as specified and directed by Engineer-in-Charge. |
| 17 | S&F in repair solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/0.3 watt one NI-ed rechargeable battery (1.2V/1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. complete all as specified and directed by Engineer-in-Charge. |
| 18 | S&Fin repair cat eye bothside reflective type of aluminium metal body alloy of size 110mm x 120mm x 20mm with PAMA striplens reflector of model No. DA 972.0 to be fixed with specified epoxy adhesive material as per manufactures instructions complete all as specified and directed by Engineer-in-Charge. |
| 19 | M&L for Manufacturing, supplying and fixing retro reflective Overhead Identification sign/cautionary mandatory and information sign board, area exceeding 1.00 Sqm but not exceeding 1.50 Sqm made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTMD- 4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in-charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). post embedded in ground with PCC 1:3:6 type C-2 using 40mm graded stone aggregate of size 45cmX45cmX60cm including necessary excavation and earth work complete all as specified and directed.Note:(i) Shape/ Design of sign board as approved by Engineer-in-Charge. (ii) The letters and symbols etc; on both side shall be as per site requirement and as approved. The size and font of wording as per direction of Engineer-in-Charge. |
| 20 | S&Fin repairmetal tubular dealineator made out of ABS round body fitted with 2 Nos 65 mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in PCC 1:2:4 150x150x300mm) type B-1 complete complete all as specified and directed by Engineer-in-Charge. |