Tender For Provision Of Mobilization Eqpt, Store, Coy Store, Clothing And Sports Stores At Inf Bde Sig Coy And Spl Repair/ Replacement Of Ci Line From Pump House To Tpt Md Accn At Jp Line At Alwar Mil Stn; 1 Excavation in trenches not exceeding 1.50m wide and not exc 1.50m in depth and getting out in soft / loose soil complete all as specified and directed. 2 All as per ser item No 1.00 but depth exc 1.5 m but n exc 3 m complete all as specified and directed. 3 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. 4 Removing surplus excavated soil to a distance n.exc 100 metre and depositing where directed at a level n.exc 1.5 m above the stafrting point complete all as specified and directed. 5 PCC (1:4:8) type D-2, using 40 mm graded stone aggregate in fdn mass concrete complete all as specified and directed. 6 M&L Reinforced cement concrete work Design Mix (M25)as in foundation including, raft, plinth beambases for column etc basement slabs under ramed piles and mass concrete complete all as specified and directed. 7 M&L Reinforced cement concrete work Design mix(M-25) as in columns, pillars, piers posts and struts complete all as specified and directed. 8 M&L Reinforced cement concrete work design mix(M-25) as in beams, cantilevers bressumers, lintel over 1.5 mtr span complete all as specified and directed. 9 M&L Reinforced cement concretework design mix (M-25) as in slab supported in walls cantilevers etc complete all as specified and directed. 10 M&L Reinforced cement concreteRCC work design mix(M-25) as chajja complete all as specified and directed. 11 M&L TMT bars, 10mm dia and overcut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed. 12 All as per ser item No above but 5mm to 10mm dia as in stirrups, spacers binders etc complete all as specified and directed. 13 M&L formwork to side of concrete foundation, footing, bases of column raft and raft beam , sides and soffits (if any) of foundation and plinh beams, and similar work, vertical or to batter complete all as specified and directed. 14 Formwork to sides of pillars, posts struts, piers, columns and stanchions, square, rectangular or polygonal for fough finished flat surfaces of concrete complete all as specified and directed. 15 M&L formwork to sides and soffits of floor or roof beam, beam nauchings, griders, bressum-mers, lintels, cantilever, shelves including supports, overhangs etc also splays between floors and beams etc complete all as specified and directed. 16 M&L formwork to soffits of suspended slab such as roof slabs, floor slabs, landing and similar work, not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. 17 Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs n exc 20 cm wide & sides of RCC/PCC bands in walls, horizintal or sloping & similar work exc 10cm but n exc 20cm wide Roughed finished surface of concrete complete all as specified and directed. 18 Treating the bottom and side of exc at the rate 5 ltr/sqm emulsion of surface area complete all as specified and directed. 19 Treating the backfil in contact with foundation at the rate of 7.5ltr/sqm emulsion of surface area complete all as specified and directed. 20 Treating the bottom surface of floorat the rate 5 ltr/sqm emulsion of surface area complete all as specified and directed. 21 Treating the soil under plinth protection at the frate of 5 Ltr/Sqm emulsiom of surface area complete all as specified and directed. 22 M&L screed laid 15mm thick in CM 1:4 with water proofing compound over green concrete surface (WPC will be measured and paid seperately) surface finished even and smooth (without using extra lime or cement) complete all as specified & directed by Engr-in-Charge. 23 M&L Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqmm including cleaning surfacesover bituminious primer complete all as specified & directed by Engr-in-Charge. 24 M&L APP based plymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven reinforcement/mat (center core) with thermal insulation laid by toarch application method with overlaps 100mm on length side and 100mm on the width side as per manufacture,s instructions with fabric (wt not less than 150 gms/sqm) on primed surface complete all as specified and directed. 25 M&L two coat of heat reflective silver aluminum paint over APP membrane complete all as specified and as directed 26 M&L providing precast cement concrete (1:2:4) type B1, using 20mm graded crushed stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses , lacing courses, parapits and railings upto60cm in height, copings kneelers, apex stones, bed plates, kerbs not provided for in item No 04028 water throughs and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 27 M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed. 28 M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed. 29 M&L15mm thick rendering in cement mortar 1:4 on fair faces of brick work surace rendering is to be even and smooth with out using extra cementincluding ixing of water proofing compound complete all as specified and directed. Note : Water proofing compound will measured and paid seperately 30 Supply only integral liquid water profing compound complete all as specified and directed. 31 M&L Rendring 10mm thick in CM 1:6 onbrick work or concrete surfaces fair faces of brick work & surfaces finished even and smooth without using extra cement complete all as specified and directed. 32 M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified and directed. 33 Material and labour for preprationover new surfaceandapplying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as er IS 15489-2004 alkarili and fungal resistance, dirt resistance exterior paint emulsion of required shade (Company Depot tinted) with silicon addtitives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm complete all as specified and directed. 34 M&L for providing and applying minimum 1mm thick wall care putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and as directed 35 M&L for preparing newly plastered surfaces and applying two coats of Oil bound distemper on walls including 2mm thick wall putty complete all as specified and directed by Engineer-in-Charge. 36 M&L preparation of newly plastered surface of ceiling applying three coats of white wash complete all as specified and directed. 37 S&F 35mm thick IInd class hard wood factory made panelled door shutter(two panel) with lock rail and panelof 9mmBWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. the size of rail and stiles as per IS: 1003 (part-I), kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified & directed by Engr-in-Charge. 38 S&F Steel windows with side hung shutters including projecting type hinges with steel handle, & steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. 39 S&F steel ventilator with top hung shutter including hinges steel peg stay complete including taking down complete all as specified and directed. 40 Framed work such asgrills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; cooler Stand, framedbalusters; walk ways; railings; framework of water tanks and similar work conforming to Fe. 290.Gde-E complete all as specified and directed. 41 S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples or nails and screws complete all as specified and directed 42 S&F Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each pane 4 mm in thickness complete all as specified& directed by Engr-in-Charge. 43 S&F 150mm Mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed. 44 S&F butt hinges,medium weight, cold rolled, mild steel,100mm long,fixed to angle iron chowkhats including welding complete all as specified and directed. 45 S&F 200 mm long Mild steel barrel tower blots, stove enamelled black, with bright bolt and fixed complete all as specified and directed. 46 S&F 300mm long mild steel sliding door bolt, bolt type, stove enamelled black,with bright bolt 12mm dia with and including a minimum of 6 bolts and nuts,four on bolt plate and two on staple plate,fitted to shutters complete all as specified and directed. 47 M&L preparation to new or previously untreated wooden surface of any description,over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 48 Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 49 M&L 75 mm thickPCC 1:4:8 type D2 (using 40mm graded aggregate) as in floor sub base complete all as specified and directed 50 M&L PCC 25mm thick 1:2:4 type B0 (using 12.5mm graded aggregate) as in floor as in levelling levelling course complete all as specified and directed. 51 Material and labour for Machine cut kota stone slab flooring 20-25 mm thick size not less than 22 x 22 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 20mm thick cement screed bed in cement mortar 1:6including rubbing and mirror polishing complete all as specified and as directed. 52 Material and labour for kota stone slab20-25 mm thick in riser of steps, skirting, dado and pillarslaid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 10mm thickrendering in cement mortar 1:6including cutting, moulding outer edges,rubbing and mirror polishing complete all as specified and as directed. 53 M&L for hard core of broken stone or boulders of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surface complete all as specified and directed. 54 M&L 75 mm thick PCC(1:3:6) type C2 (using 40 mm graded stone aggregate ) as in plinth protection finished fair and even complete all as specified & directed by Engr-in-Charge. 55 S&F in repairsstainless steel rod of 20 mm inner dia (in lengths as directed)including decorative finial at both ends and pair of stainless steel brackets fixed at both ends with rawl plug & steel screws on walls/beam,complete all as specified and directed. 56 M&L for concealed Point wiring with two single core PVC insulated for One Light point controlled by one, one way switch, unsheathed multistranded copper conductorcable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floorincluding PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box with modular sheet top cover of required module with frame for mounting switches, sockets etc complete all as specified. Note -(a) Quoted rates shall be deemed to include the cost of Cutting Chases in Stone/Brick wall and making good to the disturbed surfaces including plastering andpaintingto match with the existing colour. (b) The rates Quoted by the contractor shall be deemed to include the cost of modular cover plates of required module with frame, cost of Sheet Metal Box and no additional payment shall be made on account of the same. 57 All as per srl item No 56.00 but for One 3 pinswitch socket outlet, 5 Ampon the same board with other switches. 58 All as per srl item No 56.00 but for One 3 pin 5 amps switch socket outlet pointon independent board. 59 All as per srl item No 56.00 but for One fan point controlled by one switch and regulator. 60 All as per srl item No 56.00 but for wiring with 4.0 sq.mm multistranded cable and earth wire with copper conductor of size 4.0 sq.mm for 15 amps power/geyser point. 61 Supply and fixingModular switch, one way 6 Amp, 1 module, piano type, 230/250 volts grade on top covers (catered in point wiring above) 62 All as per srl item No 61.00 but for Modular switch, one way 16 Amp, 1 module 63 Supply and fix Modular socket outlet 2in1, 3pin 5A, 2 module multipurpose use, flush mounting type, 230/250 Volts grade on Top covers (catered in point wiring above). 64 All as per srl item No 63.00 but for Modular socket outlet 2in1, 3 pin 15 Amps flush type 65 Supply and fixing ceiling rose surface bakelite two to three terminals/plate, polycarbonate, isolated body complete all as specified and directed. 66 Supply and fixing PVC Blanking Plates one way with internal lock complete al as specified and directed. 67 Supply and fixing Lamp holder, PVC/Polycarbonate type complete with lamp LED 9 Watt for Batten fitting with back plate and all fittings complete all as specified and directed by Engr-In-Charge 68 Supply and fix LED batten (1.2m) made of CRCA sheet housing with a PC glossy diffisure duly prewired connection having nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 20 watt including driver. it should have rated system life time of 40000 burning hours at L70 and should have a temperature of 6500 K CRI >80, thd <10 and PF>0.95 complete all as specified and directed. 69 Supply and fixing LED light fitting as building security lights of 35 Watt Cap 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover,incl street light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-In-Charge 70 Supply and hanging /fixing aesthetically designed BLDC ceiling fan with soothing LED Indication 1200 mm sweep AC Supply (Input Voltage Range ; 120 to280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of B class insulation, single phase, minimum 26W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan including taking down old ceiling fan complete all as specified and as directed by Engineer-in-charge. Make/ Model: Orient-Ecotech Prime CX 5Star/Havells-Epic Pro BLDC FHCPP5SGRY48/Bajaj- Nex Glyde A-60 Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) Old ceiling fan shall be deposited in AGE E/M store yard. 71 Supply and fixing heavy duty exhaust fan with copper winding motor 100 Watt Capacity, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers mounted in suitable opening arrangement with louvers shutters suitable for operation on 230 Volt Single Phase 50 Cycle per second, AC Supply and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and fixed by using 4 Nos 200 mm long 12 mmdia bolts nuts and washers grouted in wall in CM (1:3) complete all as specified and as directed by Engineer-in-charge. 72 S&F sheet metal enclosureconcealed in wall incl making good of disturbed surfaces double door type suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 Way, 230 Volts and including taking down old U/S DB ,SPN,8 way complete all as specified & directed. 73 Supply and fix VerticalTPN DB 4 way suitable for Double Pole outgoing MCB-40 Amp-04 Nos with incoming 100 Amps, 16 KA, MCCB 4 pole-01 Nos complete with 250 Amps rated Copper busbar flush mounting, double door, proction class IP-30, IK08 complete all as specified 74 Supply and fixing 240V, 10KA C curve miniature circuit breaker (MCB) of SP 6-32 Amp poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-In-Charge 75 All as per srl item No 74.00 but for SPN 40-63 Amps 76 S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with 01 No. double pole MCB 32 Amps & including taking down old U/S enclosure complete all as specified & directed. 77 Material & Labour for Sub Main Wiring in repair with two run single core 6 Sqmm PVC insulated unsheathed(FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 6 Sqmm copper green colour earth wire all as specified and directed by Engr-in-Charge.NOTE-two run of 6 sq.mm & One run of 6 sq.mm & One run of PVC conduit with accessories shall be measured as One length. 78 Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.30mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers,PCCchamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified &directed. 79 Supply and lay and testing of cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of 16 Sqmm 4.0 Core sze. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule. 80 All as per srl item No 79.00 but for 35 Sqmm 3.5 Core. 81 Supply and spreading, levelling river sand in trenches for cables cushioning on top and bottom of cable all as specifede and directed. 82 M&L brick protection with sub classB brick laid flat across the cable complete all as specified and directed 83 M&L for boring under roads for crossing of UG Cables complete all as specifie and directed by Engr-In-Charge. 84 Supply and fix GI Pipe light grade of size 40 mmlaid in trenches under road/fixed on wall/pole for cable protection complete all as specified and directed by Engr-In-Charge 85 Supply and fixing Split type AC 1.5ton single phase 50 Hz complete with cordless remote control unit and with inbuilt air ioniserand Plasmafilterfor better indoorairqualitywithminimum3 star rating and EER3.2includingcopper piping ofadequate sizeand required length as directed duly insulated with suitable insulating material e.g. glass wool,plywood,mouldedthermocoaletccompletewithsteelbracket for condensingunitandcoppercableofsuitablesizeformakingelectric connections including necessaryPCC in 1:2:4 TypeB-I,using 20mm graded crushed stone aggregates as in founation, Platform, form work and angle iron work, steel frame made with angle iron size as directed. Make : Voltas/LG/Carreir/Blue Star/LLOYD Note :-The quoted rated shallbedeemed to inclusive of supplyand fixing setofbracketincludingnutsandbolts for outdoorunit complete. 86 Supply and fixing Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with working input voltage stabilized at 230 V with accuracy of ± 2.5% of capacity 5 KVA. Make : V Guard or Equivalent 87 Supply & install, testing & commissioning in repairs LT control panel compartmental type, Lockable fabricationmade by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (40mmx40mmx6mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glands, foundation /grouting on & including PCC as per site requirement with the following :- (a) Al bus bar400 Amp Cap- 1 Set ( Set of 4 strips) (b) MCCB 350 Amp 415V, 36 KA-1 No (incoming) (c) MCCB 160 Amp,4 Pole, 25 KA with spreader links - 2 Nos(Outgoing) (d) MCCB 125 Amp,4 Pole,16 KA with spreader links - 3 Nos(Outgoing) (e) MCCB 63 Amp,4 Pole,16 KA with spreader links -1 Nos(Outgoing) (f)Indicating fuse LED type R,Y,B - 3 Nos (g) On Load Change Over Switch 350 Amps - 01 Nos 88 Taking out ofDI/GI/CI under ground pipeline of any size 80 to 150 mm dia from trench complete all as directed by Engineer-in Charge. 89 Supply, lay, jointing and testing centrifugally cast (spun) ductile iron pressure pipe of 150 mm dia size with socket and spigot ends class K-7, ISI marked, confirming to IS: 8329/2000 suitable and including rubber gasket joint and fittings (push on) with inside cement mortar lininglaid in trenches under floor complete all as specified & directed. 90 Supply, fixing, laying GI pipe of dia 80mm medium grade galvanized ISI marked Including fittings complete all as specified and directed. 91 Supply, fixing, laying GI pipe of dia 50 mm medium grade galvanized ISI marked Including fittings complete all as specified and directed. 92 Supply and fix Sluice valve of 150mm dia size with brass spindle with hand wheel of class PN 1.6, conforming to IS 14846-2000 including suitable size bolts, nuts, washer and rubber gasket complete all as specified and directed. 93 Supply and fixed Gun-metal, globe or gate valves, 50 mm dia with iron wheel head, screwed both ends for iron pipe all as specified and directed. 94 Cutting DI line of any size 150 mm dia and insertion of any size up to 100mmof CI Tee unequal of size reducer tee, fixing connecting GI pipe of required size pipe with flange type complete with all fittings as specified and directed. 95 M&L for bends(any type, radius and angle)tapers any type(straight,bend,increasing,decreasing or double socket etc.) Tee pieces single branch, Y junction, double branch, cross(all sockets or socket and spigot or all ends flanged) collars, caps and plugs complete all as specified and directed. 96 M&L for construction of underground trench/duct of cross section area 01 mtr x 01 mtr below the Jaipur highway road near TPT linefor passing of DI pipe from JP Line to TPT line including taking necessary permission from the state authority (PWD/PHED) complete all as specified and directed. 97 M&L for Construction of Valve chamber of size 1.2X1.2m x1.0 Mwith brick masonry and MS sheet cover. 1.00 Old U/s GI/DI/CI pipe any type/size RM 800.00 30.00 24000.00 2.00 Old U/s sluice valve Each 2.00 100.00 200.00 3.00 Old U/s Gate valve Each 2.00 75.00 150.00 4.00 Old U/s GI pipe any type/size RM 530.00 20.00 10600.00; ELECTRIC ITEMS :- 1 LT circuit break, MCCB, RCCB, RCBOs, MCB, DB, ELCB, ISOLATER (i) Schneider (ii) HPL (iii) Havells (iv) Legrand (v) Siemens (vi) Schneider (vii) ABB (viii) L & T (ix) M/s Shalabh (India) Industries 2 Microprocessor Based MCCB LT, 415 Volts (i) C & S Electric Ltd (ii) Legrand (iii) Havells India Ltd (iv) L&T 3 UG LT Cables, XLPE, PVC insulated aluminium conductor for 1100 volt (i) Finolex (ii) Plaza Cables (iii) Havells (iv) Polycab (v) GLOSTER CABLES (vi) Universal Cable Ltd (vii) SCI 4 Flexible wires & cables (PVC) upto 1100 Volts (IS-694-2010) (IS Marked) (i) Polycab wires Pvt Ltd (Polycab) (ii) PLAZA (iii) Havells (iv) Finolex (v) GLOSTER (vi) BENTEC/BENLO (vii) L&T (viii) SCI 5 PVC Casing Caping (ISI Marked) (i) Finolex (ii) Modi (iii) POLYCAB (iv) Prince (v) Precision (vi) Supreme 6 Switches/Sockets/Bell Push/Ceiling Rose & Call bell (i) Polycab (ii) L&T (iii) Havells (iv) LEGRAND (v) V-GUARD (vi) HPL (vii) BENLO (viii) GOLD MEDAL 7 Laminated Sheets (i) Xylam 8 Ceiling Fans/Exhaust fan/Fresh Air Fan & Regulators (i) Crompton (ii) Usha (v) BAJAJ (iii) Khaitan (iv) Orient (vi) HAVELLS (vii) GOLD MEDAL 9 Light Fitting & Accessories (i) Phillips (ii) Crompton Greaves (iii) Legrand (iv) Havells 10 Fluorescent tube light fittings & CFL fittings (i) HPL (ii) Wipro (iii) Crompton (iv) Havells (v) Osram (vi) GE 11 Fluorescent tube rod (i) HPL (ii) Surya Roshani (iii) Asian (iv) Havells (v) Osram (vi) GE 13 MS Conduit (i) NIC (ii) BEC (iii) ASIAN (iv) KALINGA (v) BHARAT (vi) TATA (vii) JINDAL (viii) PLAZA (ix) AKG (x) PRAKASH SURYA 14 PVC Conduit (Flexible) (i) BLP (ii) Plaza (iii) Kalinga (iv) Supreme (v) Finolex (vi) POLY CAB 15 PVC Conduits (Rigid) (i) KALINGA (ii) Plaza (iii) AKG (v) SUPREME (iv) Finolex (vi) PRESTO PLAST (vii) POLYCAB 16 LED light fitting incl aviation light under water light foot light walkover light, flood light, Panel light down light, Bollards, Facade lights (i) Wipro (ii) CG (iii) Osram (iv) ORIENT ELECTRICALS (v) Havells (vi) SURYA (vii) ROSHNI (viii) POLYCAB (ix) HPL (x) PHILIPS (xi) Shakti Fixtures Pvt Ltd (xii) BAJAJ (viii) GOLD MEDAL 17. Street Light Fittings (LED) (i) HAVELLS (ii) ORIENT ELECTRIC (iii) POLYCAB (iv) HALONIX (v) BENLO/BENTECH (vi) SURYA (vii) ROSHNI (viii) GOLD MEDAL 18. GEYSER/WATER HEATER (i) HAVELLS (ii) CG (iii) GOLD MEDAL (iv) ORIENT ELECTRIC (v) CERA (vi) LUKER (vii) CGPISL